Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
Cureus ; 16(4): e57731, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38711696

ABSTRACT

Atypical lipomatous tumor/well-differentiated liposarcoma (ALT/WDL) is a rare subtype of endobronchial tumor that has been rarely reported in medical literature. Due to its low incidence, distinguishing it from endobronchial lipoma poses a significant diagnostic challenge, necessitating histopathologic and cytogenetic analysis. As of today, the treatment and surveillance protocols for these neoplasms remain poorly defined, often resulting in their misclassification and treatment as endobronchial lipomas. We present a case involving a 72-year-old male who presented with worsening dyspnea and cough. Diagnostic imaging revealed an endobronchial lesion obstructing the left main bronchus. The patient underwent a flexible bronchoscopy that identified a polypoid mass causing significant obstruction, which was subsequently resected via cryoablation. Histopathology confirmed ALT/WDL, supported by genetic analysis revealing chromosomal alterations. Following the intervention, symptoms resolved, with no recurrence on follow-up imaging. Differentiating ALT/WDL from endobronchial lipomas is necessary not only because it influences treatment decisions but also because it can significantly affect the prognosis of patients diagnosed with ALT/WDL. In this case, we emphasize the importance of considering ALT/WDL in the differential diagnosis of endobronchial tumors and highlight the use of flexible bronchoscopy as a viable substitute for rigid bronchoscopy, serving not only as a diagnostic tool but also as a therapeutic method.

2.
Cureus ; 15(5): e39122, 2023 May.
Article in English | MEDLINE | ID: mdl-37332456

ABSTRACT

Despite the benefits of the intra-aortic balloon pump (IABP) being a subject of debate, it remains a widely available and easy-to-use mechanical circulatory support device. Nonetheless, its use is not exempt from complications. Aortic dissection from IABP is an infrequent but deathly complication. We describe a case in which early recognition of the condition led to control through an endovascular approach. A 57-year-old male was admitted for acute decompensated heart failure requiring intravenous inotropic agents. While undergoing assessment for a heart transplant, he developed cardiogenic shock requiring initiation of mechanical circulatory support with an IABP. A few hours after device implantation, the patient developed acute tearing chest pain and was found to have an acute dissection in the descending thoracic aorta. Prompt liaison with the endovascular team led to a thoracic endovascular aortic repair to control the extent of the lesion.

3.
Cureus ; 15(4): e37725, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37206507

ABSTRACT

A 67-year-old male presenting with an anterior ST-segment elevation myocardial infarction (STEMI) underwent stent placement in the left anterior descending coronary. The patient was discharged on an appropriate medical regimen containing dual antiplatelet therapy (DAPT). Four days later, the patient presented with repeat acute coronary syndrome symptomatology. Electrocardiogram demonstrated ongoing STEMI in the previously treated artery distribution. Emergency angiography revealed restenosis and total thrombotic occlusion. Post-intervention stenosis was 0% after aspiration thrombectomy and balloon angioplasty. Stent thrombosis is a high-mortality and therapeutically challenging condition requiring prepared clinicians who recognize predisposing risk factors and initiate early management.

4.
Med Res Rev ; 41(1): 29-71, 2021 01.
Article in English | MEDLINE | ID: mdl-32808366

ABSTRACT

Cardiovascular diseases (CVDs) are the result of complex pathophysiological processes in the tissues comprising the heart and blood vessels. Inflammation is the main culprit for the development of cardiovascular dysfunction, and it may be traced to cellular stress events including apoptosis, oxidative and shear stress, and cellular and humoral immune responses, all of which impair the system's structure and function. An intracellular chaperone, heat shock protein 60 (HSP60) is an intriguing example of a protein that may both be an ally and a foe for cardiovascular homeostasis; on one hand providing protection against cellular injury, and on the other triggering damaging responses through innate and adaptive immunity. In this review we will discuss the functions of HSP60 and its effects on cells and the immune system regulation, only to later address its implications in the development and progression of CVD. Lastly, we summarize the outcome of various studies targeting HSP60 as a potential therapeutic strategy for cardiovascular and other diseases.


Subject(s)
Cardiovascular Diseases , Cardiovascular System , Apoptosis , Chaperonin 60 , Humans , Immune System
SELECTION OF CITATIONS
SEARCH DETAIL
...