Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
F S Rep ; 5(1): 72-79, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38524201

ABSTRACT

Objective: To compare ribonucleic acid (RNA) quantity and purity in tissue collected with different endometrial sampling methods to establish the optimal tool for use in endometrial gene expression studies. Design: Observational study. Setting: University hospital. Patients: Fourteen patients with submucosal leiomyomas. Interventions: Unguided biopsies were obtained using a low-pressure suction device before hysteroscopy from 14 patients with submucosal leiomyomas followed by guided biopsy with a resectoscope loop. Fifty-seven samples were collected: 25 obtained using a suction device and 32 with a loop. Main Outcome Measures: Total biopsy weight, RNA purity, and RNA yield for each collection method. After complementary deoxyribonucleic acid synthesis, HOXA10 expression was measured by quantitative polymerase chain reaction in the endometrium overlying and remote from the leiomyoma, as similar expression throughout the cavity was a prerequisite for the use of unguided biopsy method. Results: The median weight of the samples was significantly larger when obtained with the low-pressure suction device than with the resectoscope loop (153 vs. 20 mg). The RNA yield was similar (suction curette, 1,625 ng/mg; resectoscope loop, 1,779 ng/mg). The A260-to-A280 ratio was satisfactory for 94.7 % of the samples, with no difference between the groups. The endometrial expression of HOXA10 was similar in areas overlying the leiomyoma compared with that in remote endometrial sites (2-ΔCt = 0.0224 vs. 0.0225). Conclusions: Low-pressure endometrial suction devices provide tissue samples with acceptable RNA purity and quantity for gene expression studies. The expression of HOXA10 did not differ between endometrial sampling sites even in the presence of leiomyomas.

2.
J Matern Fetal Neonatal Med ; 34(12): 1963-1969, 2021 Jun.
Article in English | MEDLINE | ID: mdl-31422727

ABSTRACT

OBJECTIVES: Exact knowledge of fetal station and position is of paramount importance for reliable surveillance of labor progress and a prerequisite for safe operative vaginal procedures. Detailed clinical assessments are thoroughly described in old textbooks, but almost forgotten in contemporary obstetrics. Ultrasound is suggested as an objective diagnostic tool in active labor. Several publications have demonstrated a low correlation between ultrasound and clinical assessment of fetal head station and position, but the methods of clinical assessment in these studies are poorly described. We wanted to explore if a quality clinical assessment could perform better than clinical assessment in previous publications, by analyzing the correlation between a structured method of clinical assessment and intrapartum ultrasound. METHODS: In all, 100 laboring women with cervical dilatation ≥7 cm were included in a prospective cohort study at Oslo University Hospital-Ullevål from October to December 2016. The study design was cross-sectional. Clinical examinations were performed by one special educated consultant (JKI), and transabdominal and transperineal ultrasound clips were recorded and examined by a blinded expert in intrapartum ultrasound (TME). Fetal position was classified as a clock face with 12 units (hourly divisions) and thereafter categorized as occiput anterior (OA), left occiput transverse (LOT), occiput posterior (OP), and right occiput transverse (ROT) positions. Fetal station was categorized clinically from -5 to +5 and measured with ultrasound as angle of progression (AoP) and head-perineum distance (HPD). AoP is the angle between a longitudinal line through the symphysis and a tangent to the head contour. HPD is the shortest distance between the fetal skull and the perineum. RESULTS: Eight women were excluded due to strong contractions between clinical assessments and ultrasound measurements, fetal distress, or incomplete examinations. Fetal position assessed with ultrasound and clinical examination agreed exactly in 48/92 (52%) of cases, within one unit (hour) in 87/92 (95%) of cases and within two units in 90/92 (98%) of cases. It differed by three units in one case and by five units in one case. The agreement categorized into OA, LOT, OP, and ROT was good (Cohen's kappa 0.72; 95% CI 0.61-0.84). For station, the agreement was very good for both HPD (Pearson correlation coefficient r = 0.86; 95% CI 0.80-0.91) and AoP (r = 0.77; 95% CI to 0.67-0.84). The correlation between HPD and AoP was good (r = 0.76; 95% CI 0.65-0.84). CONCLUSION: We found very good correlations between structured clinical assessments and ultrasound examinations, suggesting that an objective quality in clinical examinations is possible to achieve. More focus on clinical skills training may improve accuracy for clinicians.


Subject(s)
Obstetrics , Cross-Sectional Studies , Female , Head/diagnostic imaging , Humans , Labor Presentation , Pregnancy , Prospective Studies , Ultrasonography, Prenatal
SELECTION OF CITATIONS
SEARCH DETAIL
...