Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Biotechnol Prog ; 37(2): e3105, 2021 03.
Article in English | MEDLINE | ID: mdl-33274840

ABSTRACT

Drug development is often hindered by the failure of preclinical models to accurately assess and predict the efficacy and safety of drug candidates. Body-on-a-chip (BOC) microfluidic devices, a subset of microphysiological systems (MPS), are being created to better predict human responses to drugs. Each BOC is designed with separate organ chambers interconnected with microfluidic channels mimicking blood recirculation. Here, we describe the design of the first pumpless, unidirectional, multiorgan system and apply this design concept for testing anticancer drug treatments. HCT-116 colon cancer spheroids, HepG2/C3A hepatocytes, and HL-60 promyeloblasts were embedded in collagen hydrogels and cultured within compartments representing "colon tumor", "liver," and "bone marrow" tissue, respectively. Operating on a pumpless platform, the microfluidic channel design provides unidirectional perfusion at physiologically realistic ratios to multiple channels simultaneously. The metabolism-dependent toxic effect of Tegafur, an oral prodrug of 5-fluorouracil, combined with uracil was examined in each cell type. Tegafur-uracil treatment induced substantial cell death in HCT-116 cells and this cytotoxic response was reduced for multicellular spheroids compared to single cells, likely due to diffusion-limited drug penetration. Additionally, off-target toxicity was detected by HL-60 cells, which demonstrate that such systems can provide useful information on dose-limiting side effects. Collectively, this microscale cell culture analog is a valuable physiologically-based pharmacokinetic drug screening platform that may be used to support cancer drug development.


Subject(s)
Antimetabolites, Antineoplastic/adverse effects , Drug-Related Side Effects and Adverse Reactions/pathology , Fluorouracil/adverse effects , Microfluidic Analytical Techniques/methods , Neoplasms/drug therapy , Cell Death , Drug Evaluation, Preclinical , Drug-Related Side Effects and Adverse Reactions/etiology , Drug-Related Side Effects and Adverse Reactions/metabolism , Humans , Hydrogels/chemistry , Neoplasms/metabolism , Neoplasms/pathology , Tumor Cells, Cultured
2.
Macromol Biosci ; 21(2): e2000301, 2021 02.
Article in English | MEDLINE | ID: mdl-33205616

ABSTRACT

Poly(glycerol-sebacate) (PGS) is a biodegradable elastomer known for its mechanical properties and biocompatibility for soft tissue engineering. However, harsh thermal crosslinking conditions are needed to make PGS devices. To facilitate the thermal crosslinking, citric acid is explored as a crosslinker to form poly(glycerol sebacate citrate) (PGSC) elastomers. The effects of varying citrate contents and curing times are investigated on the mechanical properties, elasticity, degradation, and hydrophilicity. To examine the potential presence of unreacted citric acid, material acidity is monitored in relation to the citrate content and curing times. It is discovered that a low citrate content and a short curing time produce PGSC with tunable mechanical characteristics similar to PGS with enhanced elasticity. The materials demonstrate good cytocompatibility with human umbilical vein endothelial cells similar to the PGS control. The research study suggests that PGSC is a potential candidate for large-scale biomedical applications because of the quick thermal crosslink and tunable elastomeric properties.


Subject(s)
Citric Acid/chemistry , Cross-Linking Reagents/chemistry , Decanoates/chemistry , Elastomers/chemistry , Glycerol/analogs & derivatives , Polymers/chemistry , Carboxylic Acids/chemistry , Cell Death , Glycerol/chemistry , Human Umbilical Vein Endothelial Cells/cytology , Humans , Hydrogen-Ion Concentration , Hydrophobic and Hydrophilic Interactions , Tensile Strength , Water/chemistry
3.
iScience ; 23(11): 101719, 2020 Nov 20.
Article in English | MEDLINE | ID: mdl-33205026

ABSTRACT

Colon cancer remains the third most common cause of cancer in the US, and the third most common cause of cancer death. Worldwide, colon cancer is the second most common cause of cancer and cancer deaths. At least 25% of patients still present with metastatic disease, and at least 25-30% will develop metastatic colon cancer in the course of their disease. While chemotherapy and surgery remain the mainstay of treatment, understanding the fundamental cellular niche and mechanical properties that result in metastases would facilitate both prevention and cure. Advances in biomaterials, novel 3D primary human cells, modelling using microfluidics and the ability to alter the physical environment, now offers a unique opportunity to develop and test impactful treatment.

4.
Adv Mater ; 32(43): e2003761, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32964586

ABSTRACT

Widely present in nature and in manufactured goods, elastomers are network polymers typically crosslinked by strong covalent bonds. Elastomers crosslinked by weak bonds usually exhibit more plastic deformation. Here, chelation as a mechanism to produce biodegradable elastomers is reported. Polycondensation of sebacic acid, 1,3-propanediol, and a Schiff-base (2-[[(2-hydroxyphenyl) methylene]amino]-1,3-propanediol) forms a block copolymer that binds several biologically relevant metal ions. Chelation offers a unique advantage unseen in conventional elastomer design because one ligand binds multiple metal ions, yielding bonds of different strengths. Therefore, one polymeric ligand coordinated with different metal ions produces elastomers with vastly different characteristics. Mixing different metal ions in one polymer offers another degree of control on material properties. The density of the ligands in the block copolymer further regulates the mechanical properties. Moreover, a murine model reveals that Fe3+ crosslinked foam displays higher compatibility with subcutaneous tissues than the widely used biomaterial-polycaprolactone. The implantation sites restore to their normal architecture with little fibrosis upon degradation of the implants. The versatility of chelation-based design has already shown promise in hydrogels and highly stretchy nondegradable polymers. The biodegradable elastomers reported here would enable new materials and new possibilities in biomedicine and beyond.


Subject(s)
Biocompatible Materials/chemistry , Chelating Agents/chemistry , Elastomers/chemistry , Animals , Decanoic Acids/chemistry , Dicarboxylic Acids/chemistry , Hydrogels/chemistry , Materials Testing , Mice , Propylene Glycols/chemistry , Schiff Bases/chemistry
5.
Biotechnol Bioeng ; 117(2): 486-497, 2020 02.
Article in English | MEDLINE | ID: mdl-31608985

ABSTRACT

Efficient and economical delivery of pharmaceuticals to patients is critical for effective therapy. Here we describe a multiorgan (lung, liver, and breast cancer) microphysiological system ("Body-on-a-Chip") designed to mimic both inhalation therapy and/or intravenous therapy using curcumin as a model drug. This system is "pumpless" and self-contained using a rocker platform for fluid (blood surrogate) bidirectional recirculation. Our lung chamber is constructed to maintain an air-liquid interface and contained a "breathable" component that was designed to mimic breathing by simulating gas exchange, contraction and expansion of the "lung" using a reciprocating pump. Three cell lines were used: A549 for the lung, HepG2 C3A for the liver, and MDA MB231 for breast cancer. All cell lines were maintained with high viability (>85%) in the device for at least 48 hr. Curcumin is used to treat breast cancer and this allowed us to compare inhalation delivery versus intravenous delivery of the drug in terms of effectiveness and potentially toxicity. Inhalation therapy could be potentially applied at home by the patient while intravenous therapy would need to be applied in a clinical setting. Inhalation therapy would be more economical and allow more frequent dosing with a potentially lower level of drug. For 24 hr exposure to 2.5 and 25 µM curcumin in the flow device the effect on lung and liver viability was small to insignificant, while there was a significant decrease in viability of the breast cancer (to 69% at 2.5 µM and 51% at 25 µM). Intravenous delivery also selectively decreased breast cancer viability (to 88% at 2.5 µM and 79% at 25 µM) but was less effective than inhalation therapy. The response in the static device controls was significantly reduced from that with recirculation demonstrating the effect of flow. These results demonstrate for the first time the feasibility of constructing a multiorgan microphysiological system with recirculating flow that incorporates a "breathable" lung module that maintains an air-liquid interface.


Subject(s)
Lab-On-A-Chip Devices , Lung , Microfluidic Analytical Techniques/instrumentation , Models, Biological , A549 Cells , Cell Survival/drug effects , Curcumin/pharmacology , Drug Evaluation, Preclinical/instrumentation , Equipment Design , Humans , Lung/cytology , Lung/drug effects , Lung/metabolism , Toxicity Tests/instrumentation , Urea/analysis , Urea/metabolism
6.
ACS Appl Mater Interfaces ; 10(11): 9235-9246, 2018 Mar 21.
Article in English | MEDLINE | ID: mdl-29474057

ABSTRACT

Microfluidic-based cell encapsulation has promising potential in therapeutic applications. It also provides a unique approach for studying cellular dynamics and interactions, though this concept has not yet been fully explored. No in vitro model currently exists that allows us to study the interaction between crypt cells and Peyer's patch immune cells because of the difficulty in recreating, with sufficient control, the two different microenvironments in the intestine in which these cell types belong. However, we demonstrate that a microfluidic technique is able to provide such precise control and that these cells can proliferate inside microgels. Current microfluidic-based cell microencapsulation techniques primarily use fluorinated oils. Herein, we study the feasibility and biocompatibility of different nonfluorinated oils for application in gastrointestinal cell encapsulation and further introduce a model for studying intercellular chemical interactions with this approach. Our results demonstrate that cell viability is more affected by the solidification and purification processes that occur after droplet formation rather than the oil type used for the carrier phase. Specifically, a shorter polymer cross-linking time and consequently lower cell exposure to the harsh environment (e.g., acidic pH) results in a high cell viability of over 90% within the protected microgels. Using nonfluorinated oils, we propose a model system demonstrating the interplay between crypt and Peyer's patch cells using this microfluidic approach to separately encapsulate the cells inside distinct alginate/gelatin microgels, which allow for intercellular chemical communication. We observed that the coculture of crypt cells alongside Peyer's patch immune cells improves the growth of healthy organoids inside these microgels, which contain both differentiated and undifferentiated cells over 21 days of coculture. These results indicate the possibility of using droplet-based microfluidics for culturing organoids to expand their applicability in clinical research.


Subject(s)
Microfluidics , Cell Survival , Gelatin , Oils , Polymers
7.
Exp Biol Med (Maywood) ; 242(17): 1701-1713, 2017 11.
Article in English | MEDLINE | ID: mdl-29065797

ABSTRACT

Integrated multi-organ microphysiological systems are an evolving tool for preclinical evaluation of the potential toxicity and efficacy of drug candidates. Such systems, also known as Body-on-a-Chip devices, have a great potential to increase the successful conversion of drug candidates entering clinical trials into approved drugs. Systems, to be attractive for commercial adoption, need to be inexpensive, easy to operate, and give reproducible results. Further, the ability to measure functional responses, such as electrical activity, force generation, and barrier integrity of organ surrogates, enhances the ability to monitor response to drugs. The ability to operate a system for significant periods of time (up to 28 d) will provide potential to estimate chronic as well as acute responses of the human body. Here we review progress towards a self-contained low-cost microphysiological system with functional measurements of physiological responses. Impact statement Multi-organ microphysiological systems are promising devices to improve the drug development process. The development of a pumpless system represents the ability to build multi-organ systems that are of low cost, high reliability, and self-contained. These features, coupled with the ability to measure electrical and mechanical response in addition to chemical or metabolic changes, provides an attractive system for incorporation into the drug development process. This will be the most complete review of the pumpless platform with recirculation yet written.


Subject(s)
Cell Culture Techniques/methods , Drug Evaluation, Preclinical/methods , Lab-On-A-Chip Devices , Microchip Analytical Procedures/methods , Models, Biological , Humans
8.
Biotechnol Prog ; 33(5): 1257-1266, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28597974

ABSTRACT

Transporting living complex cellular constructs through the mail while retaining their full viability and functionality is challenging. During this process, cells often suffer from exposure to suboptimal life-sustaining conditions (e.g. temperature, pH), as well as damage due to shear stress. We have developed a transport device for shipping intact cell/tissue constructs from one facility to another that overcomes these obstacles. Our transport device maintained three different cell lines (Caco2, A549, and HepG2 C3A) individually on transwell membranes with high viability (above 97%) for 48 h under simulated shipping conditions without an incubator. The device was also tested by actual overnight shipping of blood brain barrier constructs consisting of human induced pluripotent brain microvascular endothelial cells and rat astrocytes on transwell membranes to a remote facility (approximately 1200 miles away). The blood brain barrier constructs arrived with high cell viability and were able to regain full barrier integrity after equilibrating in the incubator for 24 h; this was assessed by the presence of continuous tight junction networks and in vivo-like values for trans-endothelial electrical resistance (TEER). These results demonstrated that our cell transport device could be a useful tool for long-distance transport of membrane-bound cell cultures and functional tissue constructs. Studies that involve various cell and tissue constructs, such as the "Multi-Organ-on-Chip" devices (where multiple microscale tissue constructs are integrated on a single microfluidic device) and studies that involve microenvironments where multiple tissue interactions are of interest, would benefit from the ability to transport or receive these constructs. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:1257-1266, 2017.


Subject(s)
Biotechnology/instrumentation , Cell Culture Techniques/instrumentation , Specimen Handling/instrumentation , Cell Culture Techniques/methods , Cell Line , Cell Survival , Equipment Design , Humans , Specimen Handling/methods
9.
Biotechnol Bioeng ; 113(10): 2213-27, 2016 10.
Article in English | MEDLINE | ID: mdl-27070809

ABSTRACT

We describe a human "Body-on-a-chip" device (or microphysiological system) that could be used to emulate drug distribution, metabolism, and action in the body. It is based upon a physiologically based pharmacokinetic-pharmacodynamic (PBPK-PD) model, where multiple chambers representing different organs are connected with fluidic channels to mimic multi-organ interactions within the body. Here we describe a pumpless 14 chamber (13 organs) microfluidic cell culture device that provides a separation between barrier and nonbarrier types of cell cultures. Our barrier chamber layer (skin, GI tract, and lung) allows for direct access and/or exposures to chemical or biological reagents forcing these reagents to pass through a barrier of cells established on a microfabricated membrane before exposing the nonbarrier tissue chambers (fat, kidney, heart, adrenal glands, liver, spleen, pancreas, bone marrow, brain, muscle) or entering the microfluidic circulation within the device. Our nonbarrier tissue chambers were created as three-dimensional configurations by resuspending cells in hydrogel (PGMatrix). We used cell lines to represent five of these organs (barrier lines-A549 [lung] and Caco2 [GI]) (nonbarrier lines-HepG2 C3A [liver], Meg01 [bone marrow], and HK2 [kidney]). The dimensions of our straight duct-like channels to each organ chamber were designed to provide the appropriate flow of a culture medium. The organ volumes and organ flow rates that have been reported for an average human male were used to estimate the desired fluid retention times in each organ chamber. The flow through the channels was induced by gravity on a custom programmed rocker platform which enabled pumpless operation and minimized bubble entrapment. The purpose of this paper is to describe the design and operation of a 14 chamber multi-organ system representing 13 tissues/organs with both barrier and nonbarrier tissue chambers and to study the interactive responses among the various cell lines. We demonstrate that five different cell lines survived with high viability (above 85%) for 7 days. We compared the individual observed flow rates to the compartments to the desired or estimated flow rates. This work demonstrates the feasibility of constructing, operating and maintaining a simple, gravity-driven, multi-organ microphysiological system with the capability of measuring cellular functions such as CYP1A1 and CYP3A4 activities, albumin release, urea, maintenance of tight junctions, and presence of surfactant for a sustained period. Biotechnol. Bioeng. 2016;113: 2213-2227. © 2016 Wiley Periodicals, Inc.


Subject(s)
Biomimetic Materials , Lab-On-A-Chip Devices , Models, Anatomic , Viscera/physiology , Cells, Cultured , Equipment Design , Equipment Failure Analysis , Humans
10.
Stem Cell Res Ther ; 4 Suppl 1: S9, 2013.
Article in English | MEDLINE | ID: mdl-24565109

ABSTRACT

A multiorgan, functional, human in vitro assay system or 'Body-on-a-Chip' would be of tremendous benefit to the drug discovery and toxicology industries, as well as providing a more biologically accurate model for the study of disease as well as applied and basic biological research. Here, we describe the advances our team has made towards this goal, as well as the most pertinent issues facing further development of these systems. Description is given of individual organ models with appropriate cellular functionality, and our efforts to produce human iterations of each using primary and stem cell sources for eventual incorporation into this system. Advancement of the 'Body-on-a-Chip' field is predicated on the availability of abundant sources of human cells, capable of full differentiation and maturation to adult phenotypes, for which researchers are largely dependent on stem cells. Although this level of maturation is not yet achievable in all cell types, the work of our group highlights the high level of functionality that can be achieved using current technology, for a wide variety of cell types. As availability of functional human cell types for in vitro culture increases, the potential to produce a multiorgan in vitro system capable of accurately reproducing acute and chronic human responses to chemical and pathological challenge in real time will also increase.


Subject(s)
Microfluidic Analytical Techniques/methods , Blood-Brain Barrier/metabolism , Cell Survival/drug effects , Epithelial Cells/cytology , Epithelial Cells/metabolism , Fluoroquinolones/chemistry , Fluoroquinolones/toxicity , Gases/metabolism , Heptanol/chemistry , Heptanol/toxicity , Humans , Lung/cytology , Microfluidic Analytical Techniques/instrumentation , Models, Biological , Muscle, Skeletal/cytology , Myocardium/cytology
11.
J Nat Prod ; 75(2): 175-80, 2012 Feb 24.
Article in English | MEDLINE | ID: mdl-22292922

ABSTRACT

Metarhizium acridum, an entomopathogenic fungus, has been commercialized and used successfully for biocontrol of grasshopper pests in Africa and Australia. Its conidia produce two novel 17-membered macrocycles, metacridamides A and B, which consist of a Phe unit condensed with a nonaketide. Planar structures were elucidated by a combination of mass spectrometric and NMR techniques. Following hydrolysis of 1, chiral amino acid analysis assigned the L-configuration to the Phe unit. A crystal structure established the absolute configuration of the eight remaining stereogenic centers in 1. Metacridamide A showed cytotoxicity to three cancer lines with IC50's of 6.2, 11.0, and 10.8 µM against Caco-2 (epithelial colorectal adenocarcinoma), MCF-7 (breast cancer), and HepG2/C3A (hepatoma) cell lines, respectively. In addition, metacridamide B had an IC50 of 18.2 µM against HepG2/C3A, although it was inactive at 100 µM against Caco-2 and MCF-7. Neither analogue showed antimicrobial, phytotoxic, or insecticidal activity.


Subject(s)
Grasshoppers/drug effects , Insecticides/isolation & purification , Macrocyclic Compounds/isolation & purification , Metarhizium/chemistry , Animals , Crystallography, X-Ray , Drug Screening Assays, Antitumor , Female , Hep G2 Cells , Humans , Insecticides/chemistry , Insecticides/pharmacology , Macrocyclic Compounds/chemistry , Macrocyclic Compounds/pharmacology , Microbial Sensitivity Tests , Molecular Structure
SELECTION OF CITATIONS
SEARCH DETAIL
...