Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Radiat Oncol Biol Phys ; 45(1): 205-13, 1999 Aug 01.
Article in English | MEDLINE | ID: mdl-10477025

ABSTRACT

PURPOSE: To report initial clinical experience with an interactive, video-based patient positioning system that is inexpensive, quick, accurate, and easy to use. METHODS AND MATERIALS: System hardware includes two black-and-white CCD cameras, zoom lenses, and a PC equipped with a frame grabber. Custom software is used to acquire and archive video images, as well as to display real-time subtraction images revealing patient misalignment in multiple views. Two studies are described. In the first study, video is used to document the daily setup histories of 5 head and neck patients. Time-lapse cine loops are generated for each patient and used to diagnose and correct common setup errors. In the second study, 6 twice-daily (BID) head and neck patients are positioned according to the following protocol: at AM setups conventional treatment room lasers are used; at PM setups lasers are used initially and then video is used for 1-2 minutes to fine-tune the patient position. Lateral video images and lateral verification films are registered off-line to compare the distribution of setup errors per patient, with and without video assistance. RESULTS: In the first study, video images were used to determine the accuracy of our conventional head and neck setup technique, i.e., alignment of lightcast marks and surface anatomy to treatment room lasers and the light field. For this initial cohort of patients, errors ranged from sigma = 5 to 7 mm and were patient-specific. Time-lapse cine loops of the images revealed sources of the error, and as a result, our localization techniques and immobilization device were modified to improve setup accuracy. After the improvements, conventional setup errors were reduced to sigma = 3 to 5 mm. In the second study, when a stereo pair of live subtraction images were introduced to perform daily "on-line" setup correction, errors were reduced to sigma = 1 to 3 mm. Results depended on patient health and cooperation and the length of time spent fine-tuning the position. CONCLUSION: An interactive, video-based patient positioning system was shown to reduce setup errors to within 1 to 3 mm in head and neck patients, without a significant increase in overall treatment time or labor-intensive procedures. Unlike retrospective portal image analysis, use of two live-video images provides the therapists with immediate feedback and allows for true 3-D positioning and correction of out-of-plane rotation before radiation is delivered. With significant improvement in head and neck alignment and the elimination of setup errors greater than 3 to 5 mm, margins associated with treatment volumes potentially can be reduced, thereby decreasing normal tissue irradiation.


Subject(s)
Head and Neck Neoplasms/radiotherapy , Radiotherapy, Conformal/instrumentation , Videotape Recording , Algorithms , Cross-Over Studies , Humans , Immobilization , Physical Phenomena , Physics , Prospective Studies , Radiotherapy, Conformal/methods , Research Design , Retrospective Studies
2.
J Nucl Med ; 40(2): 347-51, 1999 Feb.
Article in English | MEDLINE | ID: mdl-10025845

ABSTRACT

UNLABELLED: The authors outline a method for three-dimensional registration of pelvic CT and 111In-labeled monoclonal antibody capromab pendetide (111In MoAb 7E11.C5) images using 99mTc-labeled red blood cell SPECT data. METHODS: This method of CT-SPECT registration relies on the identification of major blood vessels in the CT and 99mTc SPECT images. The vessels are segmented from the image datasets by outlining them on transverse planar slices using a mouse-based drawing tool. Stacking the transverse outlines provides a three-dimensional representation of the vascular structures. Registration is performed by matching the surfaces of the segmented volumes. Dual isotope acquisition of 111In and 99mTc activities provides precise SPECT-SPECT registration so that registration in three dimensions of the 111In MoAb and CT images is achieved by applying the same transformation obtained from the 99mTc SPECT-CT registration. RESULTS: This method provided accurate registration of pelvic structures and significantly improved interpretation of 111In MoAb 7E11.C5 exams. Furthermore, sites of involvement by prostate cancer suggested by the 111In MoAb examination could be interpreted with the bony and soft tissue (nodal) anatomy seen on CT. CONCLUSION: This method is a general clinical tool for the registration of pelvic CT and SPECT imaging data. There are immediate applications in conformal radiation therapy treatment planning for certain prostate cancer patients.


Subject(s)
Image Processing, Computer-Assisted/methods , Pelvis/diagnostic imaging , Tomography, Emission-Computed, Single-Photon , Tomography, X-Ray Computed , Angiography , Antibodies, Monoclonal , Humans , Indium Radioisotopes , Male , Pelvis/blood supply , Prostatectomy , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/surgery , Radionuclide Angiography
3.
Med Phys ; 25(8): 1419-23, 1998 Aug.
Article in English | MEDLINE | ID: mdl-9725128

ABSTRACT

The optimal field shape achieved using a multileaf collimator (MLC) often requires collimator rotation to minimize the adverse effects of the scalloped dose distribution the leaf steps produce. However, treatment machines are designed to deliver wedged fields parallel or perpendicular to the direction of the leaves. An analysis of cases from our clinic showed that for 25% of the wedged fields used to treat brain and lung tumors, the wedge direction and optimal MLC orientation differed by 20 degrees or more. The recently published omni wedge technique provides the capability of producing a wedged field with orientation independent of the orientation of the collimator. This paper presents a comparison of the three-dimensional (3D) dose distributions of the omni wedged field with distributions of wedged fields produced using both the universal and dynamic wedge techniques. All measurements were performed using film dosimetry techniques. The omni wedge generated fields closely matched the conventional wedged fields. Throughout 95% of the irradiated volume (excluding the penubra), the dose distribution of the omni wedged field ranged from +5.5 to -3.5 +/- 1.5% of that of the conventionally wedged fields. Calculation of the omni wedged field is as accurate as conventional wedged field calculation when using a 3D treatment planning systems. For two-dimensional treatment planning systems, where one must assume that the omni wedged field is identical to a conventional field, the calculated field and the delivered field differs by a small amount.


Subject(s)
Radiotherapy Planning, Computer-Assisted , Radiotherapy/instrumentation , Radiotherapy/methods , Technology, Radiologic , Brain Neoplasms/radiotherapy , Humans , Lung Neoplasms/radiotherapy , Radiotherapy Dosage
4.
Int J Radiat Oncol Biol Phys ; 38(4): 855-66, 1997 Jul 01.
Article in English | MEDLINE | ID: mdl-9240655

ABSTRACT

PURPOSE: We have developed and tested an interactive video system that utilizes image subtraction techniques to enable high precision patient repositioning using surface features. We report quantitative measurements of system performance characteristics. METHODS AND MATERIALS: Video images can provide a high precision, low cost measure of patient position. Image subtraction techniques enable one to incorporate detailed information contained in the image of a carefully verified reference position into real-time images. We have developed a system using video cameras providing orthogonal images of the treatment setup. The images are acquired, processed and viewed using an inexpensive frame grabber and a PC. The subtraction images provide the interactive guidance needed to quickly and accurately place a patient in the same position for each treatment session. We describe the design and implementation of our system, and its quantitative performance, using images both to measure changes in position, and to achieve accurate setup reproducibility. RESULTS: Under clinical conditions (60 cm field of view, 3.6 m object distance), the position of static, high contrast objects could be measured with a resolution of 0.04 mm (rms) in each of two dimensions. The two-dimensional position could be reproduced using the real-time image display with a resolution of 0.15 mm (rms). Two-dimensional measurement resolution of the head of a patient undergoing treatment for head and neck cancer was 0.1 mm (rms), using a lateral view, measuring the variation in position of the nose and the ear over the course of a single radiation treatment. Three-dimensional repositioning accuracy of the head of a healthy volunteer using orthogonal camera views was less than 0.7 mm (systematic error) with an rms variation of 1.2 mm. Setup adjustments based on the video images were typically performed within a few minutes. The higher precision achieved using the system to measure objects than to reposition them suggests that the variability in repositioning is dominated by the ability of the therapist to make small, controlled changes in the position of the patient. CONCLUSION: Using affordable, off-the-shelf technology, we have developed a patient positioning system that achieves repositioning accuracy normally associated with fractionated stereotactic systems. The technique provides real-time guidance and can be used to easily and quickly correct patient setup before every treatment, thus significantly reducing overall random positioning error. This improved positioning capability provides the precision required to realize the potential gains of conformal radiotherapy.


Subject(s)
Computer Terminals , Immobilization , Subtraction Technique , Supine Position , Equipment Design , Head and Neck Neoplasms/radiotherapy , Humans
5.
Med Phys ; 23(3): 337-42, 1996 Mar.
Article in English | MEDLINE | ID: mdl-8815375

ABSTRACT

A method to produce wedged fields at any orientation relative to the collimator is described. The wedged field is generated by combining two appropriately weighted orthogonal wedged field segments at fixed collimator and gantry positions. The method requires only that wedged fields can be produced in orthogonal directions without rotating the collimator, such as is commonly provided on most radiation therapy accelerators by sets of standard and rotated wedges. Expressions are derived relating the effective wedge angle and orientation to the weighting and wedge angles of the orthogonal wedged field segments. This technique will be important when using multileaf collimator field shaping for which collimator rotation is dictated by target or critical structure shape and orientation. The term omni wedge is introduced to describe this technique.


Subject(s)
Radiotherapy Planning, Computer-Assisted/methods , Technology, Radiologic , Biophysical Phenomena , Biophysics , Humans , Mathematics , Radiotherapy Planning, Computer-Assisted/statistics & numerical data , Technology, Radiologic/statistics & numerical data
SELECTION OF CITATIONS
SEARCH DETAIL
...