Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Sports Med ; 52(4): 956-960, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38305039

ABSTRACT

BACKGROUND: Approximately 100,000 anterior cruciate ligament (ACL) reconstructions (ACLRs) occur annually in the United States, and postoperative surgical-site infection is a relatively rare but devastating complication, often leading to graft failure or septic arthritis of the knee, necessitating repeat surgery. Wrapping allografts in vancomycin-soaked gauze has been adopted as a common sterilization technique in the operating room to reduce surgical-site infection; however, identifying effective alternatives to vancomycin has not been extensively pursued. HYPOTHESIS: Tobramycin would be as effective as vancomycin in reducing the concentrations of Staphylococcus epidermidis bacteria on tendon allografts. STUDY DESIGN: Controlled laboratory study. METHODS: S. epidermidis strain ATCC 12228 was inoculated onto the human cadaveric gracilis tendon. The tendons were wrapped in sterile gauze saturated with tobramycin or vancomycin at various experimental concentrations. Bacteria remaining on the tendon were dislodged, serially diluted, and plated for colony counting. Statistical analysis was performed utilizing 2-way analysis of variance testing. Results were considered statistically significant when P < .05. RESULTS: Vancomycin (P = .0001) and tobramycin (P < .0001) reduced bacterial concentration. Tobramycin was found to produce a statistically significant reduction in bacterial concentration at concentrations as low as 0.1 mg/mL (P < .0001 and P = .01 at 10 and 20 minutes), while vancomycin produced a statistically significant reduction at a concentration as low as 2.5 mg/mL (P < .0001 at both 10 and 20 minutes). CONCLUSION: This study demonstrates that tobramycin is as effective as vancomycin in bacterial concentration reduction but can achieve this reduction level at lower doses. Further studies clarifying the biomechanical and cytotoxic effects of tobramycin on tendon tissue are indicated to solidify its use as a clinical alternative to vancomycin in ACLR. CLINICAL RELEVANCE: These results will begin establishing tobramycin as an alternative to vancomycin in ACL graft decontamination. Because of relatively frequent shortages of vancomycin, establishing tobramycin as an alternative agent is a useful option for the orthopaedic surgeon.


Subject(s)
Anterior Cruciate Ligament Injuries , Vancomycin , Humans , Vancomycin/pharmacology , Anterior Cruciate Ligament/surgery , Tobramycin/pharmacology , Decontamination , Anterior Cruciate Ligament Injuries/surgery , Surgical Wound Infection/prevention & control , Allografts
2.
J Knee Surg ; 37(5): 361-367, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37336501

ABSTRACT

The purpose of this study was to evaluate the relationship between the number of all-inside meniscal repair implants placed and the risk of repair failure. We hypothesized that the use of higher numbers of all-inside meniscus repair implants would be associated with increased failure risk. A retrospective chart review identified 351 patients who underwent all-inside meniscus repair between 2006 and 2013 by a sports medicine fellowship-trained orthopaedic surgeon at a single institution. Patient demographics (age, body mass index [BMI], sex) and surgical data (number of implants used, concomitant anterior cruciate ligament reconstruction [cACLR], and tear type/size/location) were recorded. Patients who received repairs in both menisci or who had follow-up < 1-year postoperatively were excluded. Repair failure was identified through chart review or patient interviews defined as a revision surgery on the index knee such as partial meniscectomy, total knee arthroplasty, meniscus transplant, or repeat repair. Logistic regression modeling was utilized to evaluate the relationship between the number of implants used and repair failure. A total of 227 all-inside meniscus repairs were included with a mean follow-up of 5.0 ± 3.0 years following surgery. Repair failure was noted in 68 knees (30.3%)-in 28.1% of knees with fewer than four implants and in 35.8% of knees with four or more implants (p = 0.31). No significant increase in failure was observed with increasing number of all-inside medial (odds ratio [OR]: 1.15; 95% confidence interval [CI]: 0.79-1.7; p = 0.46) or lateral (OR: 0.86; 95% CI: 0.47-1.57; p = 0.63) implants after controlling for patient age, BMI, cACLR, tear type, or size. Tears of the lateral meniscus located in the red-white and white-white zones had lower odds of failure (OR: 0.14; 95% CI: 0.02-0.88; p = 0.036) than tears within the red-red zone, and patients with cACLR had lower odds of repair failure (OR: 0.40; 95% CI: 0.18-0.86, p = 0.024) than those without. The number of all-inside implants placed during meniscus tear repair did not affect the likelihood of repair failure leading to reoperation after controlling for BMI, age, tear type, size, location, and cACLR. LEVEL OF EVIDENCE: III.


Subject(s)
Anterior Cruciate Ligament Injuries , Humans , Anterior Cruciate Ligament Injuries/surgery , Reoperation , Retrospective Studies , Knee Joint , Anterior Cruciate Ligament/surgery , Menisci, Tibial/surgery , Rupture/surgery
3.
Arthrosc Tech ; 12(8): e1347-e1353, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37654885

ABSTRACT

Radial meniscus tears occur commonly as traumatic tears in younger patients, as well as in association with concomitant degenerative changes. Traditional management of these tears has centered around partial meniscectomy; however, there has been a more recent trend toward preserving the meniscus and attempting repair. Because of the gapping and displacement that frequently occurs with these tears, repair is often challenging and is done under high amounts of tension. The following article describes a technique using a traction suture to aid in maintaining reduction throughout repair. This is followed by the use of a combination of techniques to form a "super-hashtag" configuration of both vertical and horizontal mattress sutures, leading to a secure repair under little tension.

4.
Arthrosc Tech ; 12(8): e1319-e1327, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37654892

ABSTRACT

Horizontal cleavage meniscus tears occur more frequently in older patient populations with degenerative changes within the meniscus. Traditionally, they have been managed with nonsurgical interventions or with partial meniscectomy. As increasing evidence demonstrates the link between partial meniscectomy and progressive osteoarthritis with these types of tears, as well as worse long-term outcomes and reduced cost savings, surgical repair of horizontal cleavage meniscal tears has increased in appropriate patients. This technique article highlights the evaluation, indications, and preferred repair technique for horizontal cleavage tears in appropriately selected patients.

5.
Arthrosc Tech ; 12(7): e1133-e1138, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37533914

ABSTRACT

Meniscus root tears are tears that occur within 1 cm of the meniscus root attachment to the tibia. If not repaired, root tears will lead to altered knee biomechanics and accelerated degenerative changes in the knee. In this surgical technique, we demonstrate repair of a meniscus root tear with an all-inside suture repair of the posterior meniscus that is then passed through 2 transtibial tunnels and then fixed with an anchor. After surgery, patients are non-weightbearing for 4 weeks and can return to activity by 6 months.

6.
Arthroscopy ; 38(11): 3070-3079.e3, 2022 11.
Article in English | MEDLINE | ID: mdl-36344063

ABSTRACT

PURPOSE: (1) To investigate the pattern and diameter of the iatrogenic defect that meniscal repair devices impose on meniscal tissue and (2) to determine whether repair-induced defect patterns or diameters differ across devices. METHODS: Sixty-one fresh frozen human cadaveric menisci were used (n = 9; eliminated). All-inside devices (n = 9) included ULTRA FAST-FIX, FAST-FIX 360, Depuy Mitek 0° and 12° TRUESPAN, ConMed Sequent, Zimmer Biomet JuggerStitch, Stryker IvyAIR, Arthrex FiberStitch and Meniscal Cinch II. Inside-out needles (n = 4) included ConMed HiFi, Depuy Mitek ORTHOCORD, Arthrex-2-0 FiberWire, and Stryker SharpShooter. Following India Ink staining, implant devices were inserted into cadaveric menisci. Samples were fixed in formalin solution and imaged with a high-resolution camera. Defects were classified by qualitative evaluation. Defect and needle diameter were quantified with software assistance. Statistical analysis was performed using analysis of variance testing. RESULTS: We analyzed 644 iatrogenic defects with mean defect diameter of 1.96 mm (standard deviation 0.86). For all-inside devices, defect patterns (n = 436) were 15.6% linear, 38.1% semilunar, 46.3% stellate, while inside-out devices (n = 208) were 95.7% stellate, 4.3% linear, and 0.0% semilunar. All-inside devices had mean defect diameter of 2.46 mm, while inside-out meniscus needles had mean 0.90 mm defect diameter (P < .001). FasT-FIX 360, ULTRA-FAST-FIX, and Arthrex Meniscal Cinch II induced smaller diameter defects than other all-inside devices (F = 20.2, P < .05). Strong positive correlation was found comparing outer needle diameter and mean defect diameters across all devices (R2 = 0.9447). CONCLUSIONS: Needles utilized in meniscal implant systems produce the following basic defect patterns: stellate (62.3%), semilunar (25.8%), and linear (11.9%). A strong positive correlation was found between mean defect size and outer needle diameter across all devices. Inside-out double-armed flexible needles produced significantly smaller defects than all-inside devices. Of the all-inside devices, ULTRA FAST-FIX, FAST-FIX 360, and Arthrex Meniscal Cinch II produced smaller defects on average. CLINICAL RELEVANCE: While the true clinical impact of these findings cannot be drawn from the present study, this investigation provides necessary context to better understand reported similarities and differences in healing rates and outcomes between inside-out and all-inside repair techniques.


Subject(s)
Meniscus , Tibial Meniscus Injuries , Humans , Tibial Meniscus Injuries/surgery , Menisci, Tibial/surgery , Suture Techniques , Cadaver , Iatrogenic Disease/prevention & control
7.
Arthrosc Sports Med Rehabil ; 3(3): e967-e980, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34195666

ABSTRACT

PURPOSE: To quantify healing rates and patient-reported outcome scores following repair of radial meniscus tears. METHODS: PubMed, Scopus, and Embase databases were searched according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Inclusion criteria included: human subjects with meniscal tears, full-text English language, average follow-up of at 1 year, and publication after the 2000. Exclusion criteria included technical, biomechanical, and cadaveric studies. Study quality was assessed using Coleman Methodology Scores and Methodological Index for Non-Randomized Studies (MINORS) criteria. RESULTS: Twelve studies reported on the repair of 243 radial tears in 241 patients. The mean Modified Coleman Methodology Score was 46.8, range 26-60, with a mean level of evidence of 3.5. Arthroscopic techniques were used in all studies, with 1 study using an arthroscopic-assisted 2-tunnel trans-tibial pullout technique. The mean patient age was 32 years (11-71). The mean follow-up was 35 months (12 to 75.6). The average time to surgery was 10.9 months (0.5-22.4). Eight of the 12 studies reported concomitant anterior cruciate ligament (ACL) reconstruction, with 64% having concomitant ACL injury. The most common outcome measure was the Lysholm score, which improved from 47-68.9 preoperatively to 86.4-95.6 postoperatively. Tegner Activity Scale improved from 2.5-3.1 preoperatively to 4.7-6.7 postoperatively. Healing rates were reported via magnetic resonance imaging and second-look arthroscopy. Second-look arthroscopy was performed for a variety of indications, including removal of screw, washers or plates, dissatisfaction with original procedure, partial healing found on magnetic resonance imaging, or desire of the patient to know the true healing status before return to sport. Of those assessed, 62.0% had complete healing, 30.0% partial healing, and 8.0% failure to heal. CONCLUSIONS: Patient-reported outcomes of radial meniscus repair with and without ACL reconstruction are encouraging, with high patient-reported outcomes reported at final follow-up when compared with preoperative scores. Among all meniscus repairs assessed for healing, the majority demonstrated at least some healing with an overall low rate of failure. LEVEL OF EVIDENCE: IV; systematic review of level III-IV studies.

SELECTION OF CITATIONS
SEARCH DETAIL
...