Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Cardiol ; 396: 131551, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-37866786

ABSTRACT

BACKGROUND: Following transcatheter aortic valve replacement (TAVI), the newly formed 'anatomic sinus'. may contribute to the formation of subclinical leaflet thrombosis (SLT).The evaluation of root geometry after TAVI is generally performed using multi-detector computed tomography (MDCT), and the role of transthoracic echocardiography (2D TTE) requires further validation. Thus, we aimed to test the reproducibility of 2D TTE assessment of the anatomic sinus with MDCT as a reference and its association with SLT. METHODS: 2D TTE was performed in 90 patients, and the echocardiograms were analyzed offline. Both sinus of Valsalva (SOV) and prosthesis diameters were assessed in the long- and short-axis parasternal views (PLAX/PSAX), and the anatomic sinus area was calculated. Inter- and intra-observer reproducibility were assessed using the interclass correlation coefficient (ICC). MDCT was performed in 50 individuals to evaluate concordance with 2D TTE and to detect SLT. RESULTS: There was excellent correlation regarding the diameter of the SOV and the prosthesis in PLAX (ICC: 0.93 (95% CI: 0.76,0.97); ICC: 0.80 (95% CI: 0.63,0.96)) and PSAX view (ICC: 0.90 (95% CI: 0.68,0.97); ICC: 0.88 (95% CI: 0.63,0.96)). Bland-Altman analysis of 2D TTE and MDCT anatomic sinus areas indicated a high level of agreement. SLT was detected in 8 individuals (16%); 3 patients had severe SLT at the level of 1 cusp. CONCLUSIONS: 2D TTE might play a role in the evaluation of the anatomic sinus after TAVI. The importance of this space and its effects on the SLT remain uncertain.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Reproducibility of Results
2.
Int J Cardiol ; 398: 131597, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-37979790

ABSTRACT

BACKGROUND: Subclinical leaflet thrombosis is diagnosed using multidetector computed tomography (MDCT) and is characterised by a meniscal-shaped hypoattenuated lesion of one or more leaflets. Transcatheter aortic self-expandable valves are commonly manufactured with pliable pericardium over a nitinol frame that forms leaflet and extra-leaflet components such as the valve skirt. Little is known about extra-leaflet hypoattenuated lesion localisation, including that at the anatomical sinus level. Thus, the main aim of this study was to describe leaflet and extra-leaflet (anatomic sinus and subvalvular level) hypoattenuated lesions following transcatheter aortic valve replacement with a self-expandable prosthesis. As a secondary aim, we sought to investigate predictors of hypoattenuated lesions. METHODS: Fifty patients underwent MDCT at the follow-up. RESULTS: At a follow-up of 12 months, hypoattenuated leaflet lesions with mild to severe restricted movement were detected in eight individuals (16%), anatomic sinus lesions were identified in nine patients (18%), with higher prevalence in the non-coronary sinus (16%), and subvalvular lesions with variable extension toward the valve inflow were diagnosed in eight patients (16%). In 4 patients (8%) the anatomic sinus thrombus was 'in overlap' with leaflet thrombus; in 3 patients (6%) was in continuity with subvalvular frame thrombus. Bicuspid valve was the only independent predictor associated with hypoattenuated lesions (adj OR 8.25 (95% CI: 1.38, 49.21), p = 0.02)). CONCLUSIONS: This study demonstrated that hypoattenuated lesions could be identified not only at the leaflet but also at the subvalvular and anatomic sinus levels. The clinical relevance of such lesions remains unclear.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Thrombosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/epidemiology , Treatment Outcome
3.
Am J Cardiol ; 204: 171-177, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37544140

ABSTRACT

Subclinical leaflets valve thrombosis (SLT) is a recently identified phenomenon with multidetector computer tomography after tissue aortic valve replacement. Whether SLT is more frequent after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) is currently not known. Thus, the aim of this pairwise meta-analysis was to investigate the incidence of SLT after both TAVR and SAVR, the association with anticoagulation therapy, and the risk for neurological events. We searched PubMed, Google Scholar, and Ovid MEDLINE/Embase (January 02, 2023, last update) (PROSPERO registration: CRD42022383295). Statistical analysis was performed according to a prespecified statistical analysis plan. Time-to-event outcomes were summarized as incidence rate ratios (IRR). Pooled estimates were calculated using inverse variance method and random effect model. Overall, 2 registries, 2 randomized trials, and 1 observational study (1,593 patients) were included in this meta-analysis. There was a statistically significant difference in the incidence rate at follow-up of SLT between patients who underwent TAVR and SAVR (IRR 2.07, 95% confidence interval [CI]: [1.06; 4.03], I2 79%, 95% CI: [44; 92], p = 0.03). Oral anticoagulation therapy was associated with a reduced incidence of SLT (IRR 7.51, 95% CI: [3.24; 17.37], I2 62%, 95% CI: [0; 87], p <0.001). However, the incidence of later neurological events did not differ between patients with or without SLT (IRR 1.05, 95% CI: [0.32; 3.47], p = 0.93). In conclusion, SLT was more frequently detected after TAVR than SAVR. However, it was not associated with an increased risk for neurological events. Oral anticoagulation therapy seemed to reduce the incidence of SLT.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Thrombosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Aortic Valve Stenosis/etiology , Thrombosis/epidemiology , Thrombosis/etiology , Thrombosis/drug therapy , Anticoagulants/therapeutic use , Treatment Outcome , Risk Factors , Observational Studies as Topic
4.
Radiol Med ; 128(3): 299-306, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36786969

ABSTRACT

PURPOSE: The aim of our study was to evaluate the prevalence of early complications after Transcatheter Aortic Valve Implantation (TAVI) and their correlation with the Calcium Score (CS) of the aortic valve, aorta and ilio-femoral arteries derived from pre-procedural computed tomography (CT). MATERIALS AND METHODS: We retrospectively reviewed 226 patients (100 males, mean age 79.4 ± 6.7 years) undergoing 64-slice CT for pre-TAVI evaluation from January 2018 to April 2021. The population was divided into CS quartiles. RESULTS: Overall, 173 patients underwent TAVI procedure, of whom 61% presented paravalvular leak after the procedure, 28% presented bleeding or vascular complications, 25% presented atrioventricular block, and 8% developed acute kidney injury. The prevalence of paravalvular leak and vascular complications was higher in the upper CS quartiles for aortic valve and ilio-femoral arteries. CONCLUSIONS: Aortic valve and vascular CS could help to predict post-TAVI early complications.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Male , Humans , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Calcium , Retrospective Studies , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Tomography, X-Ray Computed , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...