Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Eur Radiol ; 25(5): 1317-28, 2015 May.
Article in English | MEDLINE | ID: mdl-25510445

ABSTRACT

OBJECTIVES: To assess the technical and clinical results of MRgFUS treatment and factors affecting clinical treatment success. MATERIALS AND METHODS: A total of 252 women (mean age, 42.1 ± 6.9 years) with uterine fibroids underwent MRgFUS. All patients underwent MRI before treatment. Results were evaluated with respect to post-treatment nonperfused volume (NPV), symptom severity score (SSS), reintervention rate, pregnancy and safety data. RESULTS: NPV ratio was significantly higher in fibroids characterized by low signal intensity in contrast-enhanced T1-weighted fat saturated MR images and in fibroids distant from the spine (>3 cm). NPV ratio was lower in fibroids with septations, with subserosal component and in skin-distant fibroids (p < 0.001). NPV ratio was highly correlated with clinical success: NPV of more than 80 % resulted in clinical success in more than 80 % of patients. Reintervention rate was 12.7 % (mean follow-up time, 19.4 ± 8 months; range, 3-38). Expulsion of fibroids (21 %) was significantly correlated with a high clinical success rate. No severe adverse events were reported. CONCLUSIONS: Adequate patient selection and correct treatment techniques, based on the learning curve of this technology, combined with technical advances of the system, lead to higher clinical success rates with low complications rate, comparable to other uterine-sparing treatment options. KEY POINTS: • MRgFUS appears to be a valid alternative to other uterus-preserving therapies • Patient selection is a significant factor in achieving high NPV ratios • MRI screening parameters correlate with the amount of fibroid ablation in MRgFUS • NPV results of more than 80 % correlate with higher clinical success rates.


Subject(s)
High-Intensity Focused Ultrasound Ablation/methods , Leiomyoma/surgery , Magnetic Resonance Imaging, Interventional/methods , Uterine Neoplasms/surgery , Adult , Contrast Media , Female , Gadolinium , Humans , Image Enhancement , Treatment Outcome
2.
Invest Radiol ; 48(6): 359-65, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23385396

ABSTRACT

OBJECTIVES: The aim of this study was to assess the impact of the advanced technology of the new ExAblate 2100 system (Insightec Ltd, Haifa, Israel) for magnetic resonance imaging (MRI)-guided focused ultrasound surgery on treatment outcomes in patients with symptomatic uterine fibroids, as measured by the nonperfused volume ratio. MATERIALS AND METHODS: This is a retrospective analysis of 115 women (mean age, 42 years; range, 27-54 years) with symptomatic fibroids who consecutively underwent MRI-guided focused ultrasound treatment in a single center with the new generation ExAblate 2100 system from November 2010 to June 2011. Mean ± SD total volume and number of treated fibroids (per patient) were 89 ± 94 cm and 2.2 ± 1.7, respectively. Patient baseline characteristics were analyzed regarding their impact on the resulting nonperfused volume ratio. RESULTS: Magnetic resonance imaging-guided focused ultrasound treatment was technically successful in 115 of 123 patients (93.5%). In 8 patients, treatment was not possible because of bowel loops in the beam pathway that could not be mitigated (n = 6), patient movement (n = 1), and system malfunction (n = 1). Mean nonperfused volume ratio was 88% ± 15% (range, 38%-100%). Mean applied energy level was 5400 ± 1200 J, and mean number of sonications was 74 ± 27. No major complications occurred. Two cases of first-degree skin burn resolved within 1 week after the intervention. Of the baseline characteristics analyzed, only the planned treatment volume had a statistically significant impact on nonperfused volume ratio. CONCLUSIONS: With technological advancement, the outcome of MRI-guided focused ultrasound treatment in terms of the nonperfused volume ratio can be enhanced with a high safety profile, markedly exceeding results reported in previous clinical trials.


Subject(s)
High-Intensity Focused Ultrasound Ablation/statistics & numerical data , Leiomyoma/pathology , Leiomyoma/surgery , Magnetic Resonance Imaging/statistics & numerical data , Surgery, Computer-Assisted/statistics & numerical data , Uterine Neoplasms/pathology , Uterine Neoplasms/surgery , Adult , Female , Germany/epidemiology , Humans , Inventions/statistics & numerical data , Leiomyoma/epidemiology , Middle Aged , Prevalence , Retrospective Studies , Treatment Outcome , Tumor Burden , Uterine Neoplasms/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...