Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Nat Commun ; 11(1): 78, 2020 01 07.
Article in English | MEDLINE | ID: mdl-31911626

ABSTRACT

The SLC12A cation-Cl- cotransporters (CCC), including NKCC1 and the KCCs, are important determinants of brain ionic homeostasis. SPAK kinase (STK39) is the CCC master regulator, which stimulates NKCC1 ionic influx and inhibits KCC-mediated efflux via phosphorylation at conserved, shared motifs. Upregulation of SPAK-dependent CCC phosphorylation has been implicated in several neurological diseases. Using a scaffold-hybrid strategy, we develop a novel potent and selective SPAK inhibitor, 5-chloro-N-(5-chloro-4-((4-chlorophenyl)(cyano)methyl)-2-methylphenyl)-2-hydroxybenzamide ("ZT-1a"). ZT-1a inhibits NKCC1 and stimulates KCCs by decreasing their SPAK-dependent phosphorylation. Intracerebroventricular delivery of ZT-1a decreases inflammation-induced CCC phosphorylation in the choroid plexus and reduces cerebrospinal fluid (CSF) hypersecretion in a model of post-hemorrhagic hydrocephalus. Systemically administered ZT-1a reduces ischemia-induced CCC phosphorylation, attenuates cerebral edema, protects against brain damage, and improves outcomes in a model of stroke. These results suggest ZT-1a or related compounds may be effective CCC modulators with therapeutic potential for brain disorders associated with impaired ionic homeostasis.


Subject(s)
Brain/metabolism , Enzyme Inhibitors/administration & dosage , Hydrocarbons, Chlorinated/administration & dosage , Nitriles/administration & dosage , Protein Serine-Threonine Kinases/antagonists & inhibitors , Solute Carrier Family 12, Member 2/metabolism , Stroke/drug therapy , Animals , Brain/drug effects , Brain/enzymology , Humans , Mice , Mice, Inbred C57BL , Phosphorylation , Protein Serine-Threonine Kinases/genetics , Protein Serine-Threonine Kinases/metabolism , Solute Carrier Family 12, Member 2/genetics , Stroke/genetics , Stroke/metabolism
2.
Brain Inj ; 33(10): 1364-1371, 2019.
Article in English | MEDLINE | ID: mdl-31305157

ABSTRACT

Primary objective: Examine the correlation between acute cerebrospinal fluid (CSF) levels of N-acetylaspartate (NAA) and injury severity upon admission in addition to long-term functional outcomes of severe traumatic brain injury (TBI). Design and rationale: This exploratory study assessed CSF NAA levels in the first four days after severe TBI, and correlated these findings with Glasgow Coma Scale (GCS) score and long-term outcomes at 3, 6, 12, and 24 months post-injury. Methods: CSF was collected after passive drainage via an indwelling ventriculostomy placed as standard of care in a total of 28 people with severe TBI. NAA levels were assayed using triple quadrupole mass spectrometry. Functional outcomes were assessed using the Glasgow Outcomes Scale (GOS) and Disability Rating Scale (DRS). Results: In this pilot study, better functional outcomes, assessed using the GOS and DRS, were found in individuals with lower acute CSF NAA levels after TBI. Key findings were that average NAA level was associated with GCS (p = .02), and GOS at 3 (p = .01), 6 (p = .04), 12 (p = .007), and 24 months (p = .002). Implications: The results of this study add to a growing body of neuroimaging evidence that raw NAA values are reduced and variable after TBI, potentially impacting patient outcomes, warranting additional exploration into this finding. This line of inquiry could lead to improved diagnosis and prognosis in patients with TBI.


Subject(s)
Aspartic Acid/analogs & derivatives , Brain Injuries, Traumatic/cerebrospinal fluid , Adolescent , Adult , Aged , Aspartic Acid/cerebrospinal fluid , Disability Evaluation , Female , Glasgow Coma Scale , Glasgow Outcome Scale , Humans , Male , Middle Aged , Pilot Projects , Predictive Value of Tests , Prognosis , Prospective Studies , Treatment Outcome , Ventriculostomy , Young Adult
3.
Contraception ; 99(4): 244-250, 2019 04.
Article in English | MEDLINE | ID: mdl-30685285

ABSTRACT

OBJECTIVE: With the widespread use of sex-steroid hormones in contraceptives and hormone replacement therapy, there is an increasing need for reliable analytical methods. We report the development of a sensitive and robust UPLC-MS/MS method for quantitation of both endogenous and synthetic sex-steroid hormones in human serum. STUDY DESIGN: We developed and validated a UPLC-MS/MS method to quantify progestogens (etonogestrel, levonorgestrel, medroxyprogesterone acetate, norethindrone, progesterone) and estrogens (estradiol and ethinyl estradiol) with good accuracy, high sensitivity, and excellent robustness. We then applied the method to the analysis of sex-steroid hormones in serum from 451 clinical research participants. RESULTS: Each UPLC-MS/MS analysis was 6.5 min. The lower limits of quantitation (LLOQs) were 25 pg/ml for the progestogens, and 2.5 and 5.0 pg/ml for estradiol and ethinyl estradiol, respectively. When estradiol was analyzed without assessment of progestogens, the LLOQ was reduced to 1 pg/ml. The calibration curves were linear from 25-50,000, 2.5-2000 (1-2000 for estrogens-only analysis) and 5-2000 pg/ml, respectively. Both the accuracy and precision were below±15% not only for routine validation (intraday and interday), but for long-term (>2 years) assay robustness with external controls, thereby, demonstrating the utility of this method for multi-year clinical trial assessments of progestogens and estrogens. We applied the method to quantify sex-steroid levels in 1804 clinical samples. CONCLUSIONS: We successfully developed a UPLC-MS/MS method, and overcame the matrix suppression to allow sensitive quantitation of both synthetic and endogenous sex-steroid hormones in human serum. IMPLICATIONS: We developed a sensitive and robust UPLC-MS/MS method to accurately measure the levels of sex-steroid hormones in serum. The method overcame matrix interference barriers and achieved excellent long-term stability and reproducibility (≥96.9% accuracy; ≤13.0% relative variability measured with external controls over 2 years), demonstrating its utility in clinical sample analysis.


Subject(s)
Chromatography, Liquid/methods , Estrogens/blood , Mass Spectrometry/methods , Progestins/blood , Humans , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...