1.
Materials (Basel) ; 14(21)2021 Oct 21.
Article in English | MEDLINE | ID: mdl-34771781

ABSTRACT

The aim of this study were characterize acellular collagen matrices derived from porcine pericardium (PP) and to evaluate their properties after sterilization by ethylene oxide and gamma ray. PP matrices were subjected to alkaline hydrolysis (AH), and samples were characterized for biological stability, membrane thickness measurements, differential scanning calorimetry (DSC) and scanning electron microscopy (SEM). Subsequently, the matrices were frozen, lyophilized and sterilized by ethylene oxide or gamma radiation. For in vitro assays, CHO-K1 cell culture was used and evaluated for cytotoxicity, clonogenic survival assay, genotoxicity and mutagenicity. Analysis of variance (ANOVA) was used, followed by Dunnett's post-test, with a significance level of 5%. After AH, there was no significant change in matrix thickness. The relative biodegradability of the material after implantation was observed. Morphology and dimensions had small changes after AH. As for cell viability, none of the tested matrices showed a statistically significant difference (p > 0.05; Dunnett) regardless of the sterilization method. Furthermore, it was found that PP matrices did not interfere with the proliferation capacity of CHO-K1 cells (p > 0.05; Dunnett). As for genotoxicity, when sterilized with ethylene oxide (NP, P12 and P24), it showed genotoxic potential, but it was not genotoxic when sterilized by gamma radiation. No mutagenic effects were observed in either group. PP-derived collagen matrices hydrolyzed at different times were not cytotoxic. It is concluded that the best method of sterilization is through gamma radiation, since no significant changes were observed in the properties of the PP matrices.

2.
J Mater Sci Mater Med ; 32(9): 110, 2021 Aug 28.
Article in English | MEDLINE | ID: mdl-34453617

ABSTRACT

This study aimed to evaluate the effect of grinding on some surface properties of two lithium disilicate-based glass-ceramics, one experimental new product denominated LaMaV Press (UFSCar-Brazil) and another commercial known as IPS e-max Press (Ivoclar), in the context of simulated clinical adjustment. Discs (N = 24, 12 mm in diameter) were separated into four groups: LaMaV Press with no grinding (E), LaMaV Press after grinding (EG), IPS e-max Press with no grinding (C), and IPS e-max Press after grinding (CG). A 0.1-mm deep grinding was carried out on EG and CG samples (final thickness of 1.4 mm) using a diamond stone in a low-speed device. The E and C samples had the same thickness. The effect of grinding on the sample surfaces was evaluated by X-ray diffraction, mechanical and optical profilometry, scanning electron microscopy, goniometry, and Vickers hardness. The mean roughness (Ra) was evaluated by Kruskal-Wallis and Student-Newman-Keuls statistics. The surface energy (SE) by the sessile drop method and Vickers hardness (VH) were analyzed using two-way ANOVA. The Ra medians were E = 1.69 µm, EG = 1.57 µm, C = 1.45 µm, and CG = 1.13 µm with p = 0.0284. The SE and VH were similar for all materials and treatments. Grinding smoothed the surfaces and did not significantly alter the hardness and surface energy of both LaMaV Press and IPS e-max Press. These glass-ceramics presented similar surface properties, and clinical adjustments can be implemented without loss of performance of both materials. A grinding standardization device developed that allowed to control the amount of grinding, the speed of rotation speed and the force exerted on the samples.


Subject(s)
Ceramics/chemistry , Dental Porcelain/chemistry , Ceramics/chemical synthesis , Computer-Aided Design , Dental Porcelain/chemical synthesis , Diamond/chemistry , Hardness , Humans , Materials Testing , Mechanical Phenomena , Microscopy, Electron, Scanning , Surface Properties , X-Ray Diffraction
3.
Eur J Clin Invest ; 50(4): e13214, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32048275

ABSTRACT

BACKGROUND: Odontogenic myxoma (OM) is a rare neoplasm, which originates from odontogenic ectomesenchyme. There is no study in the literature that analyses the best standards for OM diagnosis and how the treatment modalities may influence the recurrence rates. OBJECTIVE: To evaluate the best standards for odontogenic myxoma (OM) diagnosis and treatment, and how these may influence the recurrence rates. STUDY DESIGN: Two independent researchers performed a systematic review in many databases. Fifty-two eligible studies were included for qualitative analysis. Bias analysis was conducted according to Oxford Centre for Evidence-Based Medicine. RESULTS: A total of 1363 OM cases were reported on, and female gender with average age of 27 years is the most common patient profile. Conventional microscopic findings were observed in 93.43% of the reported cases. In 57.49% of the cases, multilocular radiographic appearance was present, followed by unilocular appearance (32.87%). Posterior mandible was the site with the major prevalence, while surgical resection was the most common treatment modality, followed by enucleation. Recurrence rates for both treatment modalities were approximately close (13.04% and 25.0%, respectively). CONCLUSION: The correct diagnosis of OM relies on the association of clinical, radiographic and microscopic findings. About imaging examinations, panoramic radiography and computed tomography are sufficient for the evaluation of OM. Recurrence rates were closely among the two most used surgery treatments. So according to some clinical-radiological aspects, conservative surgery may be preferred than aggressive surgery modalities.


Subject(s)
Jaw Neoplasms/diagnosis , Myxoma/diagnosis , Odontogenic Tumors/diagnosis , Bias , Humans , Jaw Neoplasms/pathology , Jaw Neoplasms/surgery , Magnetic Resonance Imaging , Myxoma/pathology , Myxoma/surgery , Neoplasm Recurrence, Local , Odontogenic Tumors/pathology , Odontogenic Tumors/surgery , Radiography, Panoramic , Tomography, X-Ray Computed
4.
J Prosthet Dent ; 117(1): 158-163, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27475916

ABSTRACT

STATEMENT OF PROBLEM: The changes that occur after brushing yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) are unknown. These changes may favor the retention of microorganisms and chemisorption of water, impairing its longevity. OBJECTIVE: The purpose of this in vitro study was to evaluate the effects of a whitening dentifrice on Y-TZP surfaces after simulating 10 years of brushing. MATERIAL AND METHODS: Seventy-two bar-shaped specimens (20×4×1.2 mm) were divided into 4 groups: storage in distilled water (SW, control), brushing with distilled water (BW), brushing with dentifrice (BD), and brushing with whitening dentifrice (BWD). Brushing was conducted using a linear brushing machine (878400 cycles, 0.98 N, soft toothbrush). The mean roughness (Ra) was analyzed with a profilometer and the superficial topography with scanning electron microscopy (SEM) at baseline and after treatment. Crystalline phases were characterized using x-ray diffraction. Baseline and posttreatment Ra were analyzed using the 1-way ANOVA and Tukey HSD multiple comparison test; the paired t test was used for intragroup comparison (all α=.05). RESULTS: The Ra (µm) means (before/after treatment) were SW 0.28/0.28; BW 0.32/0.31; BD 0.28/0.36; BWD 0.30/0.20. No statistically significant difference was found for Ra at baseline (P=.108) than for posttreatment results (P<.001); the BD group had higher Ra values when compared with baseline (P=.019); the BWD group had the lowest values (P<.001). The BD surfaces showed pronounced scratches and detachment of the surface, while BWD showed smoother surfaces; similar crystallographic results among groups were observed. CONCLUSIONS: Brushing Y-TZP with conventional dentifrice increased roughness, while brushing with whitening dentifrice reduced roughness. Neither dentifrice changed the crystallographic phases after brushing.


Subject(s)
Dentifrices/adverse effects , Toothbrushing/adverse effects , Yttrium , Zirconium , In Vitro Techniques , Surface Properties , Yttrium/standards , Zirconium/standards
SELECTION OF CITATIONS