Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Pers Med ; 12(8)2022 Aug 05.
Article in English | MEDLINE | ID: mdl-36013234

ABSTRACT

Unrestricted Kinematic alignment (KA) in total knee arthroplasty (TKA) replicates the joint line of each patient by adjusting the cuts based on the anatomy of the patient. Mechanical alignment (MA) aims to restore a neutral mechanical axis of the leg, irrespective of the joint line orientation. The purpose of the present study was to compare contact pressure and contact areas of the polyethylene (PE) bearing surface as well as von Mises stress of the PE-tibial tray interface for MA and KA in the same patient, using CT data and finite element analysis. Finite element models were created from lower leg CT scans of 10 patients with knee osteoarthritis with different phenotypes. Mechanical PE properties were experimentally determined by tensile tests on dumbbell specimens. For numerical simulation purposes an adjusted non-linear material model with the maximum load to failure of 30.5 MPa, was calibrated and utilized. Contact pressure points were the deepest parts of the polyethylene inlay. Contact pressures were either very similar or were increased for MA knees throughout the gait cycle. KA either increased or had a comparable contact area, compared to MA. KA and MA produced comparable von Mises stresses, although both alignments breached the failure point of 30.5 MPa in all 3 valgus knees. This might indicate a higher probability of failure at the inlay-tibial baseplate interface. By maintaining the joint line orientation, KA reduces or has comparable contact pressures on the PE bearing surface by increasing or maintaining the contact area throughout one gait cycle in a validated finite element analysis model in 10 different knee phenotypes. The von Mises stress on the PE-tibial component interface was comparable, except for the valgus knees, where the load to failure was achieved in both alignment strategies and slightly higher stresses were observed for KA. Further studies for different knee phenotypes are needed to better understand the pressure changes depending on the alignment strategy applied.

2.
Strahlenther Onkol ; 198(11): 1032-1041, 2022 11.
Article in English | MEDLINE | ID: mdl-35697775

ABSTRACT

PURPOSE: For stereotactic radiation therapy of intracranial malignancies, a patient's head needs to be immobilized with high accuracy. Fixation devices such as invasive stereotactic head frames or non-invasive thermoplastic mask systems are often used. However, especially stereotactic high-precision masks often cause discomfort for patients due to a long manufacturing time during which the patient is required to lie still and because the face is covered, including the mouth, nose, eyes, and ears. To avoid these issues, the target was to develop a non-invasive 3D-printable mask system with at least the accuracy of the high-precision masks, for producing masks which can be manufactured in the absence of patients and which allow the eyes, mouth, and nose to be uncovered during therapy. METHODS: For four volunteers, a personalized 3D-printed mask based on magnetic resonance imaging (MRI) data was designed and manufactured using fused filament fabrication (FFF). Additionally, for each of the volunteers, a conventional thermoplastic stereotactic high-precision mask from Brainlab AG (Munich, Germany) was fabricated. The intra-fractional fixation accuracy for each mask and volunteer was evaluated using the motion-correction algorithm of functional MRI measurements with and without guided motion. RESULTS: The average values for the translations and rotations of the volunteers' heads lie in the range between ±1 mm and ±1° for both masks. Interestingly, the standard deviations and the relative and absolute 3D displacements are lower for the 3D-printed masks compared to the Brainlab masks. CONCLUSION: It could be shown that the intra-fractional fixation accuracy of the 3D-printed masks was higher than for the conventional stereotactic high-precision masks.


Subject(s)
Masks , Radiosurgery , Humans , Immobilization/methods , Radiosurgery/methods , Imaging, Three-Dimensional/methods , Printing, Three-Dimensional
SELECTION OF CITATIONS
SEARCH DETAIL
...