1.
J Clin Microbiol ; 52(6): 1898-900, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24648564

ABSTRACT

We conducted a controlled clinical comparison of PF Plus, the new pediatric medium with adsorbent polymeric beads, versus the charcoal-containing PF medium in the BacT/Alert blood culture system. A total of 2,381 pediatric cultures were enrolled, and 1,703 (71.5%) were deemed to be compliant and acceptable for analysis. Seventy-two cultures (4.2%) had a positive result with 80 clinically significant microorganisms. The results showed that the PF Plus medium yielded more clinically significant microorganisms than the BacT/Alert system (P < 0.05). In addition, the PF Plus bottle yielded positive results an average of 5.0 h earlier than the PF bottle for compliant clinically significant cultures (18.3 h versus 23.2 h, P = 0.004). PF Plus is an improved medium for detecting microorganisms that cause pediatric bloodstream infections.


Subject(s)
Blood/microbiology , Culture Media/chemistry , Microbiological Techniques/methods , Sepsis/diagnosis , Sepsis/microbiology , Adolescent , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Sensitivity and Specificity , Time Factors
2.
Am J Med ; 123(9): 819-28, 2010 Sep.
Article in English | MEDLINE | ID: mdl-20800151

ABSTRACT

BACKGROUND: Bloodstream infections are a major cause of morbidity and mortality in adults. Bloodstream infections should be reassessed periodically because of increased antibiotic resistance, more patients receiving immunomodulatory therapy, improved antiretroviral therapy, and acquisition of infection in health care settings other than hospitals. METHODS: We conducted retrospective assessment by infectious disease physicians of hospitalized adults with positive blood cultures at 3 academic medical centers. RESULTS: Two thousand two hundred seventy positive blood culture episodes occurred in 1706 patients. Of 2669 isolates, 51% represented true infection, 41% contamination, and 8% unknown clinical significance. Although coagulase-negative staphylococci were most common, only 10% were clinically significant. Among 1225 true bloodstream infections, the most frequent isolates were Staphylococcus aureus, Escherichia coli, Enterococcus spp., Klebsiella pneumoniae, coagulase-negative staphylococci, Pseudomonas aeruginosa, Candida albicans, Enterobacter cloacae, and Serratia marcescens. Intravenous catheters were the most common primary source of bloodstream infection (23% of episodes). Most (81%) bloodstream infections were acquired in the hospital or other health care settings. Crude and attributable in-hospital case-fatality ratios were 20% and 12%, respectively, lower than in previous studies. Increasing age, hypotension, absence of fever, hospital acquisition, extreme white blood cell count values, and the presence of the acquired immunodeficiency syndrome, malignancy, or renal disease were significantly associated with an increased risk of in-hospital attributable death in multivariable analysis. CONCLUSIONS: The proportion of bloodstream infections due to intravenous catheters is continuing to increase. Most episodes were acquired in the hospital or other health care setting. In-hospital case-fatality ratios have decreased compared with previous studies. Several previously identified factors associated with an increased mortality remain statistically significant.


Subject(s)
Bacteremia/diagnosis , Bacteremia/mortality , Fungemia/diagnosis , Fungemia/mortality , Adult , Aged , Bacteremia/complications , Bacteremia/drug therapy , Bacteremia/microbiology , Catheters, Indwelling/adverse effects , Early Diagnosis , Female , Fungemia/complications , Fungemia/drug therapy , Fungemia/microbiology , Hospital Mortality , Hospitals, University/statistics & numerical data , Humans , Infusions, Intravenous/adverse effects , Length of Stay , Male , Middle Aged , Multivariate Analysis , Odds Ratio , Retrospective Studies , Risk Factors , United States/epidemiology
3.
J Clin Microbiol ; 46(9): 3087-90, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18650347

ABSTRACT

Identification of viridans group streptococci (VGS) to the species level is difficult because VGS exchange genetic material. We performed multilocus DNA target sequencing to assess phylogenetic concordance of VGS for a well-defined clinical syndrome. The hierarchy of sequence data was often discordant, underscoring the importance of establishing biological relevance for finer phylogenetic distinctions.


Subject(s)
Endocarditis, Bacterial/microbiology , Streptococcal Infections/microbiology , Viridans Streptococci/genetics , Humans , Phylogeny , Sequence Analysis, DNA
4.
J Clin Microbiol ; 46(8): 2681-5, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18579712

ABSTRACT

The new Neisseria-Haemophilus identification (NH) card for Vitek 2 was compared with 16S rRNA gene sequencing (16S) as the reference method for accurate identification of Neisseria spp., Haemophilus spp., and other fastidious gram-negative bacteria. Testing was performed on the Vitek 2 XL system with modified software at three clinical trial laboratories. Reproducibility was determined with nine ATCC quality control strains tested 20 times over a minimum of 10 days at all three sites. A challenge set of 30 strains with known identifications and 371 recent fresh and frozen clinical isolates were also tested. Expected positive and negative biochemical reactions were also evaluated for substrate reproducibility. All microorganisms were tested on the NH card, and all clinical and stock isolates were saved for 16S testing. All reproducibility tests yielded expected results within a 95% confidence interval. For challenge microorganisms, there was 98% overall correct identification, including 8% low discrimination, 2% incorrect identification, and 0% unidentified. For clinical strains, there was 96.5% overall correct identification, including 10.2% low discrimination, 2.7% incorrect identification, and 0.8% unidentified. The 2.7% (10/371) of clinical isolates that gave an incorrect identification consisted of 7 isolates correct to genus and 3 strains incorrect to genus. There were an additional 27 strains (primarily Neisseria species) for which the 16S identification result was different from the NH card result. These were all unclaimed species by the system. The new NH card met all performance criteria within a 95% confidence interval compared to identification of clinical isolates by 16S.


Subject(s)
Bacterial Typing Techniques/methods , Haemophilus/isolation & purification , Neisseria/isolation & purification , DNA, Bacterial/genetics , Humans , RNA, Ribosomal, 16S/genetics , Reproducibility of Results , Sensitivity and Specificity , Sequence Analysis, DNA
5.
J Clin Microbiol ; 46(8): 2646-51, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18562580

ABSTRACT

The new anaerobe and Corynebacterium (ANC) identification card for Vitek 2 was compared with a 16S rRNA gene sequencing (16S) reference method for accuracy in the identification of corynebacteria and anaerobic species. Testing was performed on a Vitek 2 XL system with modified software at three clinical trial laboratories. Reproducibility was determined with nine ATCC quality control strains that were tested 20 times over a minimum of 10 days at all three sites. A challenge set of 50 well-characterized strains and 365 recent fresh and frozen clinical isolates were included in the study. The expected positive and negative biochemical well reactions were also evaluated for substrate reproducibility. All strains were tested with the ANC card, and clinical isolates were saved for 16S rRNA gene sequencing. All reproducibility tests yielded expected results within a 95% confidence interval, except for that with Corynebacterium striatum ATCC 6940, for which identification failed at one trial site. For the challenge isolates, there was 98% correct identification, 5% low discrimination, and 2% incorrect identification, and 0% were unidentified. For clinical strains, there was 95.1% correct identification, 4.9% low discrimination, and 4.6% incorrect identification, and 0.3% were unidentified. The 4.6% (17/365) of clinical isolates that were incorrectly identified consisted of 14 isolates that were correct at the genus level and three that were incorrect at the genus level. The new ANC card met all performance criteria within a 95% confidence interval compared to the identification performance by 16S rRNA gene sequencing.


Subject(s)
Bacteria, Anaerobic/isolation & purification , Bacterial Typing Techniques/methods , Corynebacterium/isolation & purification , DNA, Bacterial/genetics , Humans , RNA, Ribosomal, 16S/genetics , Reproducibility of Results , Sensitivity and Specificity , Sequence Analysis, DNA
6.
J Clin Microbiol ; 46(5): 1596-601, 2008 May.
Article in English | MEDLINE | ID: mdl-18322067

ABSTRACT

Accurate species determination for anaerobes from blood culture bottles has become increasingly important with the reemergence of anaerobic bacteremia and prevalence of multiple-drug-resistant microorganisms. Our knowledge of the taxonomical diversity of anaerobes that cause bloodstream infections is extremely limited, because identification historically has relied on conventional methods. Over a 5-year period, we profiled anaerobic bacteremia at a large tertiary care hospital with 16S rRNA gene sequencing to gain a better understanding of the taxonomical diversity of the bacteria. Of 316 isolates, 16S rRNA gene sequencing and phylogenetic analysis identified 316 (100%) to the genus or taxonomical group level and 289 (91%) to the species level. Conventional methods identified 279 (88%) to the genus level and 208 (66%) to the species level; 75 (24%) were misidentified at the species level, and 33 (10%) results were inconclusive. High intragenus variability was observed for Bacteroides and Clostridium species, and high intraspecies variability was observed for Bacteroides thetaiotaomicron and Fusobacterium nucleatum. Sequence-based identification has potential benefits in comparison to conventional methods, because it more accurately characterizes anaerobes within taxonomically related clusters and thereby may enable better correlation with specific clinical syndromes and antibiotic resistance patterns.


Subject(s)
Bacteremia/microbiology , Bacteria, Anaerobic/classification , Bacteria, Anaerobic/isolation & purification , Biodiversity , Genetic Variation , Bacteria, Anaerobic/genetics , DNA, Bacterial/genetics , DNA, Ribosomal/genetics , Humans , Phylogeny , RNA, Ribosomal, 16S/genetics , Sequence Analysis, DNA
7.
J Clin Microbiol ; 45(11): 3546-8, 2007 Nov.
Article in English | MEDLINE | ID: mdl-17881544

ABSTRACT

Although several reports have shown that two to three 20-ml blood cultures are adequate for the detection of bacteremia and fungemia in adults, a recent study (F. R. Cockerill et al., Clin. Infect. Dis. 38:1724-1730, 2004) found that two blood cultures detected only 80% of bloodstream infections and that three blood cultures detected 96% of episodes. We reviewed data at two university hospitals to determine whether the recent observations by Cockerill et al. are applicable more widely. We assessed all blood cultures obtained from adult inpatients from 1 January 2004 through 31 December 2005 at Robert Wood Johnson University Hospital and Duke University Medical Center. All instances in which > or =3 blood cultures per patient were obtained during a 24-h period were included. The medical records of patients who met the inclusion criteria were reviewed retrospectively to determine the clinical significance of the positive blood culture (true infection versus contamination). Data were analyzed to determine the cumulative sensitivity of blood cultures obtained sequentially during the 24-h time period. Of 629 unimicrobial episodes with > or =3 blood cultures obtained during the 24-h period, 460 (73.1%) were detected with the first blood culture, 564 (89.7%) were detected with the first two blood cultures, 618 (98.2%) were detected with the first three blood cultures, and 628 (99.8%) were detected with the first four blood cultures. Of 351 unimicrobial episodes with > or =4 blood cultures obtained during the 24-h period, 257 (73.2%) were detected with the first blood culture, 308 (93.9%) were detected with the first two blood cultures, 340 (96.9%) were detected with the first three blood cultures, and 350 (99.7%) were detected with the first four blood cultures. Among unimicrobial episodes, Staphylococcus aureus was more likely to be detected with the first blood culture (approximately 90% detected with the first blood culture). There were 58 polymicrobial episodes in which > or =3 blood cultures were obtained. Forty-seven (81.0%) were detected with the first blood culture, 54 (93.1%) were detected with the first two blood cultures, and 58 (100%) were detected with the first three blood cultures. The results of this study indicate that two blood cultures in a 24-h period will detect approximately 90% of bloodstream infections in adults. To achieve a detection rate of >99%, as many as four blood cultures may be needed. The previously held axiom that virtually all bloodstream infections can be detected with two to three blood cultures may no longer be valid but may also depend on the definition of the "first" blood culture obtained (see Materials and Methods and Discussion in the text).


Subject(s)
Bacteremia/diagnosis , Fungemia/diagnosis , Microbiological Techniques/methods , Adult , Humans
8.
J Clin Microbiol ; 45(4): 1357-9, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17267634

ABSTRACT

To assess relative performances in the BacT/ALERT blood culture system, we compared results from the direct inoculation of standard media and inoculation after the transport of blood samples in Vacutainer tubes with sodium polyanethol sulfonate. No significant differences in yields or times to detection were found for 387 clinically important isolates from 4,306 blood culture sets.


Subject(s)
Bacteria/isolation & purification , Bacteriological Techniques/methods , Blood/microbiology , Aerobiosis , Anaerobiosis , Bacteremia/microbiology , Bacteria/growth & development , Humans , Sensitivity and Specificity , Specimen Handling
9.
J Clin Microbiol ; 45(2): 299-302, 2007 Feb.
Article in English | MEDLINE | ID: mdl-17122016

ABSTRACT

To assess the relative yields in automated microbial detection systems of bacteria and yeasts isolated from the blood of adult patients with suspected sepsis, we compared the new VersaTREK system (VTI) (TREK Diagnostic Systems, Cleveland, OH) to the BacT/ALERT 3D system (3D) (bioMérieux, Inc., Durham, NC). Identical protocols were followed for the two systems. Paired aerobic (REDOX 1) and anaerobic (REDOX 2) VTI media were compared with standard aerobic (SA) and anaerobic (SN) 3D media; each of the four culture bottles was filled with 6 to 9 ml of blood. All bottles flagged positive by the instruments were subcultured to determine both true-positive (growth) and false-positive (no growth) cultures. Additionally, to assess false-negative bottles, terminal subcultures were done on all negative companion bottles to true-positive bottles. All isolates were identified by standard methods. All 4 bottles were adequately filled and yielded 413 clinically significant isolates in 5,389 (79%) of the 6,786 4-bottle sets obtained. Although no overall difference in yield or in time to detection was detected between the two systems, significantly more streptococci and enterococci as a group were detected by VTI. Moreover, significantly more microorganisms were detected by VTI for patients receiving antimicrobial therapy. The two systems were comparable (P, not significant) at detecting the 179 unimicrobial episodes of bacteremia seen. False-positive rates for aerobic and anaerobic bottles, respectively, were 1.6% and 0.9% for VTI and 0.7% and 0.8% for 3D. We conclude that the VTI and 3D systems are comparable for detection of bloodstream infections with bacteria or yeasts.


Subject(s)
Bacteremia/microbiology , Bacteria/isolation & purification , Blood/microbiology , Culture Media , Fungemia/microbiology , Fungi/isolation & purification , Adult , Aerobiosis , Anaerobiosis , Bacteria/growth & development , Bacteriological Techniques , Fungi/growth & development , Humans , Reagent Kits, Diagnostic
10.
J Clin Microbiol ; 43(12): 6150-1, 2005 Dec.
Article in English | MEDLINE | ID: mdl-16333117

ABSTRACT

To validate performance, we compared the new plastic BacT/ALERT (bioMérieux, Durham, NC) SN bottle to the current glass SN bottle with samples of blood obtained for culture from adults and found them comparable for both recovery and speed of detection of microorganisms. We conclude that the safety advantage of plastic bottles can be achieved without compromising performance.


Subject(s)
Bacteremia/microbiology , Bacteria/growth & development , Blood/microbiology , Culture Media , Glass , Plastics , Adult , Anaerobiosis , Bacteremia/diagnosis , Bacteria/classification , Bacteria/isolation & purification , Bacteriological Techniques/instrumentation , Humans
11.
J Clin Microbiol ; 43(4): 1960-2, 2005 Apr.
Article in English | MEDLINE | ID: mdl-15815032

ABSTRACT

A new, clear-plastic nonvented aerobic FA bottle, designed to prevent breakage, has been developed for the BacT/ALERT blood culture system. We assessed the new plastic FA bottle by comparing its performance with that of the current glass FA bottle for recovery of microorganisms and time to detection of growth in blood samples obtained for culture from adult patients with suspected bloodstream infections. We conclude that the BacT/ALERT plastic and glass FA bottles are comparable for recovery of microorganisms and that the safety advantage of plastic bottles can be achieved without compromising performance.


Subject(s)
Blood/microbiology , Culture Media , Glass , Plastics , Reagent Kits, Diagnostic , Adult , Bacteremia/diagnosis , Bacteremia/microbiology , Bacteria/growth & development , Bacteria/isolation & purification , Fungemia/diagnosis , Fungemia/microbiology , Fungi/growth & development , Fungi/isolation & purification , Humans , Microbiological Techniques
12.
J Clin Microbiol ; 43(1): 445-7, 2005 Jan.
Article in English | MEDLINE | ID: mdl-15635011

ABSTRACT

The plastic pediatric BacT/ALERT (bioMérieux, Durham, N.C.) PF (PPF) is a new nonvented aerobic culture medium in a clear plastic bottle designed to prevent breakage. We compared the performance of the new PPF bottle to that of the present glass BacT/ALERT PF bottle for the recovery of microorganisms as well as for the time to detection of growth in samples of blood obtained for culture from children. We found that the PPF and PF bottles were comparable for recovery of microorganisms and that the safety advantage of plastic bottles can be achieved without compromising performance.


Subject(s)
Bacteria/isolation & purification , Blood/microbiology , Glass , Plastics , Yeasts/isolation & purification , Bacteremia/diagnosis , Bacteremia/microbiology , Bacteriological Techniques/instrumentation , Bacteriological Techniques/methods , Child , Child, Preschool , Culture Media , Fungemia/diagnosis , Fungemia/microbiology , Humans
13.
J Clin Microbiol ; 42(8): 3747-51, 2004 Aug.
Article in English | MEDLINE | ID: mdl-15297525

ABSTRACT

Imipenem is approved by the U.S. Food and Drug Administration (FDA) for treatment of infections caused by Enterococcus faecalis. However, there are no NCCLS guidelines for testing susceptibility of enterococci against imipenem. To assess whether or not ampicillin or penicillin could be used as a surrogate for broth microdilution (BMD) testing of imipenem versus Enterococcus species, 633 strains of E. faecalis, E. faecium, and other enterococci isolated from blood cultures of patients at three geographically distinct university hospitals were tested by the NCCLS BMD and disk diffusion (DD) methods. Using FDA susceptibility breakpoints for imipenem and NCCLS breakpoints for penicillin and ampicillin, categorical agreement (CA) for penicillin-imipenem and ampicillin-imipenem tested with E. faecalis and E. faecium by BMD was >/=94% but was /=98% and was 92% for other enterococci; CA for penicillin-imipenem was 91% for E. faecalis, 98% for E. faecium, and 87% for other enterococci. Further analysis showed that testing E. faecalis with ampicillin resulted in no false-susceptible (FS) or false-resistant (FR) results by BMD, no FS results by DD, and a single FR result by DD (0.2%), whereas testing with penicillin resulted in no FS results by BMD or DD and two FR results by BMD (0.4%). For E. faecium and other enterococci, the combination of FS and FR results was such that surrogate testing with penicillin or ampicillin appears not to be sufficiently reliable to be used clinically. We conclude that ampicillin is an accurate predictor of the in vitro activity of imipenem against E. faecalis.


Subject(s)
Ampicillin/pharmacology , Enterococcus/drug effects , Imipenem/pharmacology , Microbial Sensitivity Tests/methods , Penicillins/pharmacology , Enterococcus faecalis/drug effects , Gram-Positive Bacterial Infections/diagnosis , Humans , Microbial Sensitivity Tests/standards , Practice Guidelines as Topic , Reproducibility of Results
14.
J Clin Microbiol ; 41(6): 2391-4, 2003 Jun.
Article in English | MEDLINE | ID: mdl-12791854

ABSTRACT

Standard aerobic media are widely used for culturing blood with the BacT/ALERT (BioMérieux, Inc., Durham, N.C.) (BM) and BACTEC 9240 (BD Diagnostic Systems, Sparks, Md.) (BD) automated continuously monitoring instrument systems. Although similarly composed of soybean-casein digest broths, the formulations of the standard aerobic media available for these instruments differ from each other in supplements and in sodium polyanetholesulfonate concentration. Therefore, we compared the standard aerobic media available for these systems at two university hospitals. Blood samples from adult patients with suspected bloodstream infection were inoculated at the bedside into nonvented BM and BD standard aerobic blood culture bottles and incubated in their respective instruments. The laboratories received 6,743 pairs of bottles that were each filled with 8 to 12 ml of blood. A total of 523 isolates representing true infections were recovered from 257 patients; of these isolates, 348 were recovered from both the BD and the BM bottles, 108 were recovered from the BM bottles only, and 67 were recovered from the BD bottles only (P < 0.005). More staphylococci (P < 0.05), especially coagulase-negative staphylococci (P < 0.05), and yeasts (P < 0.01) were recovered from BM bottles than from BD bottles. Of 291 unimicrobial episodes of bloodstream infection, 220 were detected with both bottles, 41 were detected with the BM bottles only, and 30 were detected with the BD bottles only (difference not significant). Among 335 cultures that were positive in both bottles within the first 72 h of incubation, the median times to detection were 14 h for BM bottles and 13 h for BD bottles. Rates for false-positive results were 0.5% for BM bottles and 0.1% for BD bottles. One BM bottle and seven BD bottles yielded false-negative results. We conclude that the BM medium provides improved recovery of microorganisms, especially staphylococci and yeasts, compared with that provided by the BD medium.


Subject(s)
Bacteremia/microbiology , Bacteria/growth & development , Blood/microbiology , Fungemia/microbiology , Fungi/growth & development , Reagent Kits, Diagnostic , Aerobiosis , Bacteremia/diagnosis , Bacteria/isolation & purification , Bacteriological Techniques/instrumentation , Bacteriological Techniques/methods , Culture Media , Fungemia/diagnosis , Fungi/isolation & purification , Humans
15.
J Clin Microbiol ; 41(6): 2703-5, 2003 Jun.
Article in English | MEDLINE | ID: mdl-12791910

ABSTRACT

We compared the dried MicroScan microdilution panel, Synergy Quad plate agar dilution, and high-potency disk diffusion screening methods for the detection of high-level aminoglycoside resistance in 815 enterococcal bloodstream isolates. Agreement between the three methods was 99% when testing for high-level gentamicin resistance and 96% when testing for high-level streptomycin resistance.


Subject(s)
Anti-Bacterial Agents/pharmacology , Drug Resistance, Bacterial , Enterococcus/drug effects , Gentamicins/pharmacology , Streptomycin/pharmacology , Bacteremia/microbiology , Blood/microbiology , Gram-Positive Bacterial Infections/microbiology , Humans , Microbial Sensitivity Tests/methods
16.
J Clin Microbiol ; 41(5): 1987-90, 2003 May.
Article in English | MEDLINE | ID: mdl-12734238

ABSTRACT

To compare the performance of the BACTEC 13A (Becton Dickinson, Sparks, Md.), BACTEC MYCO/F LYTIC (Becton Dickinson), BacT/ALERT MB (bioMérieux, Durham, N.C.), and ISOLATOR 10 lysis-centrifugation (Wampole Laboratories, Cranbury, N.J.) systems for detection of mycobacteremia in adults, we inoculated 5-ml aliquots of blood from patients with suspected mycobacteremia into the bottle or tube required for each system. Of 600 sets tested, 85 (14%) yielded Mycobacterium avium complex (MAC) and 9 (2%) yielded other species of mycobacteria. Of 26 complete (three bottles and one tube) adequately filled (5 +/- 1 ml) sets from which MAC was recovered, BACTEC 13A was positive for 19 (73%), BACTEC MYCO/F LYTIC was positive for 21 (81%), BacT/ALERT MB was positive for 22 (85%), and ISOLATOR 10 was positive for 21 (81%). Of the six possible two-way comparisons, the mean times to detection for the recovery of MAC from each bottle in positive adequately paired sets were 15.3 days for BACTEC 13A versus 12.8 days for MYCO/F LYTIC for 33 of 340 pairs, 14.1 days for BACTEC 13A versus 11.6 days for BacT/ALERT MB for 38 of 380 pairs, 12.6 days for BACTEC 13A versus 20.0 days for ISOLATOR 10 for 26 of 261 pairs, 12.8 days for BACTEC MYCO/F LYTIC versus 11.0 days for BacT/ALERT MB for 33 of 340 pairs, 13.2 days for BACTEC MYCO/F LYTIC versus 20.4 days for ISOLATOR 10 for 24 of 230 pairs, and 9.9 days for BacT/ALERT MB versus 19.0 days for ISOLATOR 10 for 24 of 257 pairs. There were no significant differences in yields between the systems. However, the mean time to detection differed significantly among the systems. The time to detection was shortest for BacT/ALERT MB, followed by BACTEC MYCO/F LYTIC and BACTEC 13A and then ISOLATOR 10. Although the numbers were too small for statistical comparison, the time to detection was substantially shorter for MAC than for Mycobacterium tuberculosis complex in the liquid systems. The continuously monitored systems (BACTEC MYCO/F LYTIC and BacT/ALERT MB) were as sensitive and, on balance, faster for the detection of MAC bacteremia than were the heretofore standard manual ISOLATOR 10 and radiometric BACTEC 13A systems.


Subject(s)
Bacteremia/diagnosis , Bacteriological Techniques/instrumentation , Mycobacterium Infections/diagnosis , AIDS-Related Opportunistic Infections/diagnosis , AIDS-Related Opportunistic Infections/microbiology , Adult , Bacteremia/complications , Bacteremia/microbiology , Bacteriological Techniques/methods , Bacteriological Techniques/statistics & numerical data , Humans , Mycobacterium/isolation & purification , Mycobacterium Infections/complications , Mycobacterium Infections/microbiology , Mycobacterium avium Complex/isolation & purification , Sensitivity and Specificity , Time Factors
17.
Antimicrob Agents Chemother ; 46(11): 3676-8, 2002 Nov.
Article in English | MEDLINE | ID: mdl-12384390

ABSTRACT

We determined the antibiotic susceptibilities of 1,785 enterococcal bloodstream isolates collected over 25 years. Antibiotic resistance emerged at a greater rate in Enterococcus faecium than in other enterococcal species, and E. faecium isolates became proportionally more common over time. Our findings confirm the pattern of emerging antibiotic resistance among enterococci and highlight the increasing importance of E. faecium as a cause of bloodstream infection.


Subject(s)
Enterococcus/drug effects , Gram-Positive Bacterial Infections/microbiology , Colorado/epidemiology , Drug Resistance, Bacterial , Gram-Positive Bacterial Infections/epidemiology , Humans , North Carolina/epidemiology , Population Surveillance , Time Factors , United States/epidemiology