Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Surg Oncol ; 30(9): 5685-5689, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37314544

ABSTRACT

BACKGROUND: Sentinel lymph node (SLN) status is pivotal for treatment decision-making in patients with breast cancer. Superparamagnetic iron oxide nanoparticles (SPIO) have been shown to be equivalent to the dual technique with technetium99m (Tc99) and blue dye (BD) for SLN detection. The aim of this study was to determine the feasibility of detecting SLNs using an ultra-low dose of SPIO. METHOD: Patients planned for breast conserving surgery and SLN biopsy were included. An intradermal injection of 0.1 mL SPIO was administered at the areolar border up to 7 days before surgery. Tc99/BD was administered according to clinical routine. SLNs were detected during surgery using a handheld magnetometer. All nodes with a magnetic and/or radioactive signal, as well as blue or clinically suspicious nodes, were harvested and analyzed. RESULTS: In 50 patients, SPIO was injected a median of 4 days before surgery. At least one SLN was found in all patients with both methods. A total of 98 SLNs were removed; 90 were detected using SPIO and 88 using Tc99/BD. Of the 90 SLNs detected by SPIO, 80 were Tc99/BD positive (concordance 89%). Histopathological analysis classified 16 patients with tumor cells deposit and 9 with macro-metastasis > 2mm, where one SLN was identified only by the radioactive technique and one only by the magnetic technique. DISCUSSION: SLN detection using 0.1 mL ultra-low dose SPIO injected intradermally was successful in all patients. A future analysis will determine whether the approach using an ultra-low dose of SPIO injected intradermally will minimize skin staining and MRI artefacts.


Subject(s)
Breast Neoplasms , Sentinel Lymph Node , Humans , Female , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Breast Neoplasms/pathology , Sentinel Lymph Node/diagnostic imaging , Sentinel Lymph Node/surgery , Sentinel Lymph Node/pathology , Lymph Nodes/diagnostic imaging , Lymph Nodes/surgery , Lymph Nodes/pathology , Lymphatic Metastasis/pathology , Sentinel Lymph Node Biopsy/methods , Magnetic Iron Oxide Nanoparticles
3.
Eur J Surg Oncol ; 48(2): 326-332, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35000820

ABSTRACT

BACKGROUND: In patients with melanoma, sentinel lymph node (SLN) status is pivotal for treatment decisions. Current routine for SLN detection combines Technetium99m (Tc99) lymphoscintigraphy and blue dye (BD). The primary aim of this study was to examine the feasibility of using a low dose of superparamagnetic iron oxide (SPIO) injected intracutaneously to detect and identify the SLN, and the secondary aim was to investigate if a low dose of SPIO would enable a preoperative MRI-evaluation of SLN status. METHODS: Patients with melanoma of the extremities were eligible. Before surgery, a baseline MRI of the nodal basin was followed by an injection of a low dose (0.02-0.5 mL) of SPIO and then a second MRI (SPIO-MRI). Tc99 and BD was used in parallel and all nodes with a superparamagnetic and/or radioactive signal were harvested and analyzed. RESULTS: Fifteen patients were included and the SLNB procedure was successful in all patients (27 SLNs removed). All superparamagnetic SLNs were visualized by MRI corresponding to the same nodes on scintigraphy. Micrometastatic deposits were identified in four SLNs taken from three patients, and SPIO-MRI correctly predicted two of the metastases. There was an association between MRI artefacts in the lymph node and the dose SPIO given. DISCUSSION: It is feasible to detect SLN in patients with melanoma using a low dose of SPIO injected intracutaneously compared with the standard dual technique. A low dose of SPIO reduces the lymph node MRI artefacts, opening up for a non-invasive assessment of SLN status in patients with cancer.


Subject(s)
Extremities/diagnostic imaging , Magnetic Iron Oxide Nanoparticles , Melanoma/diagnostic imaging , Sentinel Lymph Node Biopsy/methods , Sentinel Lymph Node/diagnostic imaging , Skin Neoplasms/diagnostic imaging , Adult , Aged , Aged, 80 and over , Extremities/pathology , Feasibility Studies , Female , Humans , Lymphoscintigraphy/methods , Magnetic Resonance Imaging , Magnetometry , Male , Melanoma/pathology , Middle Aged , Neoplasm Staging , Sentinel Lymph Node/pathology , Skin Neoplasms/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...