Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Biophys Rev ; 11(5): 721-728, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31502190

ABSTRACT

Organoids are in vitro 3D self-organizing tissues that mimic embryogenesis. Organoid research is advancing at a tremendous pace, since it offers great opportunities for disease modeling, drug development and screening, personalized medicine, as well as understanding organogenesis. Mechanobiology of organoids is an unexplored area, which can shed light to several unexplained aspects of self-organization behavior in organogenesis. It is becoming evident that collective cell behavior is distinctly different from individual cells' conduct against certain stimulants. Inherently consisting of higher number of degrees of freedom for cell motility and more complex cell-to-cell and cell-to-extracellular matrix behavior, understanding mechanotransduction in organoids is even more challenging compared with cell communities in 2D culture conditions. Yet, deciphering mechanobiology of organoids can help us understand effects of mechanical cues in health and disease, and translate findings of basic research toward clinical diagnosis and therapy.

2.
Future Med Chem ; 11(7): 693-705, 2019 04.
Article in English | MEDLINE | ID: mdl-30964329

ABSTRACT

Targeted liposomes with different combinations of five ligands (for brain/amyloid targeting) were evaluated for hemocompatibility. Results reveal that all liposomes studied, caused minimum hemolysis; targeted liposomes slightly reduced blood coagulation time, but not significantly more than control liposomes; and compliment factors SC5b9 and iC3b increased when compared with the buffer, by most targeted liposomes. However, the specific amounts of both factors were similar with those induced by control liposomes. Thus, the targeted liposomes are unanticipated to cause hypersensitivity problems. Good correlations between vesicle size and produced factor amounts were observed. In conclusion, the current targeted liposomes are not expected to cause serious blood toxicity, if used in vivo.


Subject(s)
Amyloid/metabolism , Biocompatible Materials/chemistry , Biocompatible Materials/metabolism , Liposomes/chemistry , Liposomes/metabolism , Antibodies, Monoclonal/metabolism , Apolipoproteins E/chemistry , Blood Coagulation/drug effects , Brain/metabolism , Complement C3b/metabolism , Complement Membrane Attack Complex/metabolism , Curcumin/chemistry , Ethanolamines/chemistry , Hemolysis/drug effects , Humans , Nanoparticles/chemistry , Particle Size , Phosphatidylcholines/chemistry
3.
Front Cell Dev Biol ; 4: 113, 2016.
Article in English | MEDLINE | ID: mdl-27790615
4.
Macromol Biosci ; 16(3): 381-94, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26618787

ABSTRACT

Glycosaminoglycans (GAGs) chondroitin sulfate, heparin, hyaluronan, and sulfated hyaluronan are lower and higher thiolated to enable a one-step covalent modification of gold or vinyl-terminated surfaces. Measurements of water contact angle and zeta potentials reveal that sulfated GAG-modified surfaces are more wettable and possess a negative surface potential. Additionally, higher thiolated GAGs (tGAGs) exhibit increased wettability and higher surface roughness. Fibronectin (FN) adsorption increases with sulfation degree of tGAGs. The tGAG-functionalized surfaces with higher degree of sulfation promote fibroblast adhesion most under serum-free conditions. The preadsorption of FN allows for more cell adhesion on tGAG surfaces. Metabolic activity measurements show that cell growth is enhanced for tGAGs up to a certain thiolation degree. Overall, thiolation of GAGs does not hamper their bioactivity toward proteins and cells, which make them highly interesting for biomimetic surface modification of implants and tissue engineering scaffolds.


Subject(s)
Dermis/metabolism , Fibroblasts/metabolism , Fibronectins/chemistry , Glycosaminoglycans/chemistry , Sulfhydryl Compounds/chemistry , Tissue Scaffolds/chemistry , Cell Adhesion , Dermis/cytology , Fibroblasts/cytology , Humans
5.
Int J Pharm ; 432(1-2): 91-8, 2012 Aug 01.
Article in English | MEDLINE | ID: mdl-22569232

ABSTRACT

Stainless steel surfaces were processed by means of plasma enhanced chemical vapor deposition (PE-CVD) fed with acrylic acid vapors in order to functionalize them with carboxyl groups, which were subsequently activated for covalent immobilization of heparin-loaded (HEP) NH(2) group-functionalized (Fun) nanoliposomes (NLs). Empty Fun or HEP non-functionalized (control) NLs were used as controls. NLs were characterized for mean diameter, surface charge and heparin encapsulation/release. Different lipid compositions were used for NL construction; PC/Chol (2:1mol/mol) or PC/Chol (4:1mol/mol) (fluid type vesicles) [which allow gradual release of heparin] and DSPC/Chol (2:1mol/mol) (rigid type vesicles). Surface haemocompatibility was tested by measuring blood clotting time. Platelet adhesion on surfaces was evaluated morphologically by SEM and CLSM. The haemocompatibility of plasma-processed surfaces was improved (compared to untreated surfaces); Fun-HEP NL-coated surfaces demonstrated highest coagulation times. For short surface/blood incubation periods, surfaces coated with Fun-HEP NLs consisting of PC/Chol (2:1) had higher coagulation times (compared to DSPC/Chol NLs) due to faster release of heparin. Heparin release rate from the various NL types and surface platelet adhesion results were in agreement with the corresponding blood coagulation times. Concluding, covalent immobilization of drug entrapping NLs on plasma processed surfaces is a potential method for preparation of controlled-rate drug-eluting metallic stents or devices.


Subject(s)
Anticoagulants/chemistry , Heparin/chemistry , Stainless Steel/chemistry , Cholesterol/chemistry , Humans , Liposomes , Metals , Particle Size , Phosphatidylcholines/chemistry , Phosphatidylethanolamines/chemistry , Plasma/chemistry , Platelet Adhesiveness , Polyethylene Glycols/chemistry
6.
J Mol Recognit ; 24(5): 847-53, 2011.
Article in English | MEDLINE | ID: mdl-21812059

ABSTRACT

Leukocytes, as an indispensable arm of the immune system, need to be recruited from the flowing blood and transferred to the sites of infection. Their extravasation is feasible due to their ability to tether and roll over the activated endothelium, which is much dependent on the association of their selectin molecules with ligands on the activated endothelial cells. In view of the importance of this interaction for the physiological immune functions as well as for autoimmune diseases, specifying the affinity of selectins to their ligands at the single molecule level appears a challenging task to gain insight into the mechanisms that control leukocyte-endothelial avidity. To this end we functionalized substrates with P-selectin and cantilever probes with its major ligand, the P-selectin glycoprotein ligand-1, and used atomic force microscopy to measure their unbinding force. Two different chemical protocols were used for the tethering of the molecules on the substrates, one based on a homobifunctional poly(ethylene glycol) linker and the other on the use of antibody-specific binding. The unbinding forces measured with the two methods were 312 ± 149 and 230 ± 57 pN, respectively. Measurements on activated endothelials, declaratory of single molecule interactions, gave comparable results.


Subject(s)
Microscopy, Atomic Force/methods , P-Selectin/chemistry , P-Selectin/metabolism , Animals , Cattle , Cells, Cultured , Membrane Glycoproteins/chemistry , Membrane Glycoproteins/metabolism
7.
Colloids Surf B Biointerfaces ; 75(1): 252-9, 2010 Jan 01.
Article in English | MEDLINE | ID: mdl-19783413

ABSTRACT

Atomic force microscopy (AFM) was used to measure the non-specific detachment force of single fibrinogen molecules from glass surfaces. The identification of single unbinding events was based on the characteristics of the parabolic curves, recorded during the stretching of protein molecules. Fibrinogen molecules were covalently bound to Si(3)N(4) AFM tips, previously modified with 3-aminopropyl-dimethyl-ethoxysilane, through a homobifunctional poly(ethylene glycol) linker bearing two hydroxysulfosuccinimide esters. The most probable detachment force was found to be 210 pN, when the tip was retracting with a velocity of 1400 nm/s, while the distribution of the detachment distances indicated that the fibrinogen chain can be elongated beyond the length of the physical conformation before detachment. The dependence of the most probable detachment force on the loading rate was examined and the dynamics of fibrinogen binding to the surface were found amenable to the simple expression of the Bell-Evans theory. The theory's expansion, however, by incorporating the concept of the rupture of parallel residue-surface bonds could only describe the detachment of fibrinogen for a small number of such bonds. Finally, the mathematical expression of the Worm-Like Chain model was used to fit the stretching curves before rupture and two interpretations are suggested for the description of the AFM curves with multiple detachment events.


Subject(s)
Fibrinogen/metabolism , Microscopy, Atomic Force , Biomechanical Phenomena , Fibrinogen/ultrastructure , Glass/chemistry , Humans , Protein Binding , Surface Properties
8.
J Biomed Nanotechnol ; 5(4): 409-15, 2009 Aug.
Article in English | MEDLINE | ID: mdl-20055087

ABSTRACT

The haemolysis caused by various types of liposomes was measured after incubation of liposomes with human red blood cell (erythrocyte) suspension. Liposomes composed of phospholipids and containing or not arsonolipids (arsonoliposomes) were tested. In some cases liposomes that were coated with polyethylene glycol (MW 2000), which were formulated by including 8 mol% DSPE-PEG2000 in their lipid membrane, were used. Multilamellar vesicles were prepared by the thin film hydration technique (conventional liposomes) or by the one-step technique (arsonoliposomes). Sonicated vesicles were produced by probe sonication of the initial liposome preparations. Phospholipid concentration in the liposome dispersions were measured by the Stewart assay, and adjusted accordingly. Haemolysis was measured after incubating 100 microl of liposome dispersions with 900 microl of red blood cell suspension (blood) for 1 h. The results reveal that the haemolysis caused, when liposomes are incubated in blood at concentrations below 0.16 mg (lipid)/ml (blood), was minimum. Only in case of Pegylated arsonoliposomes, significant haemolysis percents were observed. At higher lipid concentrations, 0.38 or 0.6 mg/ml, the haemolysis caused by arsonoliposomes was substantially increased, even in the cases of non-Pegylated arsonoliposomes. In most cases, especially when arsonolipid-containing liposomes were evaluated, vesicle size also had considerable effect on vesicle-induced haemolysis. Nevertheless, at concentrations which are relevant with liposomal drug administration in humans, all formulations tested demonstrated negligible haemolysis.


Subject(s)
Erythrocytes/cytology , Erythrocytes/drug effects , Hemolysis/drug effects , Lipids/administration & dosage , Polyethylene Glycols/administration & dosage , Unilamellar Liposomes/administration & dosage , Cell Size/drug effects , Cells, Cultured , Dose-Response Relationship, Drug , Erythrocytes/physiology , Hemolysis/physiology , Humans
9.
Biointerphases ; 3(1): 1-8, 2008.
Article in English | MEDLINE | ID: mdl-20408656

ABSTRACT

The study of protein-surface interactions is of great significance in the design of biomaterials and the evaluation of molecular processes in tissue engineering. The authors have used atomic force microscopy (AFM) to directly measure the force of attraction/adhesion of fibrinogen coated tips to mica surfaces and reveal the effect of the surrounding solution pH and ionic strength on this interaction. Silica colloid spheres were attached to the AFM cantilevers and, after plasma deposition of poly(acrylic acid), fibrinogen molecules were covalently bound on them with the help of the cross-linker 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC) in the presence of N-hydroxysulfosuccinimide (sulfo-NHS). The measurements suggest that fibrinogen adsorption is controlled by the screening of electrostatic repulsion as the salt concentration increases from 15 to 150 mM, whereas at higher ionic strength (500 mM) the hydration forces and the compact molecular conformation become crucial, restricting adsorption. The protein attraction to the surface increases at the isoelectric point of fibrinogen (pH 5.8), compared with the physiological pH. At pH 3.5, apart from fibrinogen attraction to the surface, evidence of fibrinogen conformational changes is observed, as the pH and the ionic strength are set back and forth, and these changes may account for fibrinogen aggregation in the protein solution at this pH.

10.
Colloids Surf B Biointerfaces ; 57(1): 89-96, 2007 May 15.
Article in English | MEDLINE | ID: mdl-17337166

ABSTRACT

Although several investigations have been reported on the effect of pH or ionic strength on protein adsorption, most of them have been carried out with protein monolayers and not with single molecules. We have used atomic force microscopy to image, in phosphate buffer, single fibrinogen molecules adsorbed on mica and compare the surface coverage at variable pH (7.4, 5.8, 3.5) or ionic strength (15, 150, 500 mM) conditions. The images obtained and the statistical analysis of the surface coverage indicate adsorption enhancement at the IEP of fibrinogen (pH 5.8) and minimum adsorption at pH 3.5. On the other hand, more protein was adsorbed when the salt concentration of the buffer at pH 7.4 was increased from 15 to 150 mM. However, further increase of salt concentration up to 500 mM resulted in decreased adsorption. To confirm the aforementioned results an approaching bare Si(3)N(4) tip was used as an electrostatic analogue to a protein molecule and interaction force curves between it and the substrate were recorded. The results were in consistence with the double layer theory which justifies the screening of electrostatic repulsion as the salt concentration increases.


Subject(s)
Aluminum Silicates/chemistry , Fibrinogen/chemistry , Adsorption , Algorithms , Data Interpretation, Statistical , Freeze Drying , Humans , Hydrogen-Ion Concentration , Image Processing, Computer-Assisted , Microscopy, Atomic Force
11.
Biomaterials ; 27(12): 2525-33, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16410022

ABSTRACT

We investigate the possibility of coating polymer-covered stents with heparin-encapsulating liposomes for improving their haemocompatibility. Thin-film hydration (for multilamellar vesicles, MLV), and the dehydration-rehydration vesicle (DRV) methods are used for preparation of low-molecular weight heparin (LMWH)-encapsulating liposomes with varying lipid compositions. Liposomes are characterized for LMWH encapsulation and retention. For measurement of LMWH, a chromogenic technique is adjusted. For evaluation of heparin release from vesicles in platelet poor plasma (PPP) coagulation time is measured in presence of liposomal samples. Results reveal that LMWH encapsulation in liposomes is higher in DRV, however compositions with high encapsulation are leaky during buffer incubation. Most liposomes release LMWH slowly during plasma incubation (retention after 24 h ranges between 74% and 95%). Concerning the haemocompatibility of polyethylene terephthlate-covered stents after coating with LMWH-encapsulating liposomes, there is a marked increase (higher for DRV-coated stents compared to MLV) in plasma recalcification time compared to the control (plain blood) and reference (non-coated stent), which increases with blood-material contact time. This is probably due to LMWH release, demonstrating that encapsulated LMWH retains its biological functionality. Interestingly, the DRV-coated stents retained a high plasma recalcification time and a large number of liposomes on the stents (as proven by SEM studies) even after extensive washing (high shear conditions), proving that this method may be functional under high flow applying in vivo conditions.


Subject(s)
Coated Materials, Biocompatible , Drug Compounding , Heparin, Low-Molecular-Weight/metabolism , Liposomes , Polyethylene Terephthalates/metabolism , Stents , Blood Platelets/metabolism , Blood Platelets/ultrastructure , Complement Activation , Heparin, Low-Molecular-Weight/chemistry , Humans , Plasma/chemistry , Plasma/metabolism , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...