Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Arch Orthop Trauma Surg ; 142(6): 1039-1046, 2022 Jun.
Article in English | MEDLINE | ID: mdl-33575925

ABSTRACT

INTRODUCTION: Periprosthetic femoral fractures (PFF) are detrimental for patients. Vancouver B2 fractures about a cemented stem can be revised to a longer uncemented stem or using an in-cement revision, if the cement mantle is adequate. There are reports documenting the success of both techniques. The aim of this single centre study was to perform a direct comparison of these two procedures. MATERIALS AND METHODS: A retrospective study of consecutive Vancouver B2 PFFs around a cemented stem during 16 years was performed. All study cases were treated either using an in-cement revision or with an uncemented stem revision. Preoperatively, the groups were compared based upon age, gender, ASA, BMI, and Charlson comorbidity score. The outcome measures were surgical time, complications, in-hospital stay, revisions, 1-year readmission rate, and survivorship. RESULTS: After a median of 3.5 years, there were 70 patients in the uncemented and 31 in the in-cement group. There was no difference in any of the preoperative variables. Surgical time was shorter for in-cement revisions by a mean of 45 min (p < 0.001). There was no difference in in-hospital stay, surgical complications or readmissions. Implant survival at 5 years was 93.5% for the in-cement and 94.4% for the uncemented revision (p = 0.946). Patient survivorship at 5 years was 62.5% for the in-cement and 69.8% for the uncemented group (p = 0.094). CONCLUSIONS: This study demonstrates that in-cement revision is a valid treatment option for Vancouver B2 fractures, comparable to uncemented stem revision, if certain criteria are met. There was no difference in revision rate, patient survivorship, complications, readmissions or in-hospital stay.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Fractures , Hip Prosthesis , Periprosthetic Fractures , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Bone Cements , Femoral Fractures/etiology , Femoral Fractures/surgery , Hip Prosthesis/adverse effects , Humans , Periprosthetic Fractures/etiology , Periprosthetic Fractures/surgery , Reoperation/adverse effects , Retrospective Studies
2.
N Z Med J ; 133(1511): 52-60, 2020 03 13.
Article in English | MEDLINE | ID: mdl-32161421

ABSTRACT

AIM: The incidence of venous thromboembolism (VTE) following arthroplasty and hip fracture surgery remains an important metric for quality and financial reasons. An audit at our institution between 2006-2010 showed a higher VTE rate than international data did at the time. This study aims to determine rates of DVT and PE in patients undergoing hip and knee arthroplasty and hip fracture surgery at Waitemata District Health Board (Waitemata DHB) between 1 January 2013 and 31 December 2016. METHODS: This study is a retrospective review of all VTE within three months of elective hip or knee replacement or hip fracture surgery. Data were identified for the period between 2013 and 2016 from Waitemata DHB patient databases, including a dedicated VTE database. RESULTS: The current rates of deep vein thrombosis (DVT) and pulmonary embolism (PE) at our institution following hip or knee arthroplasty or hip fracture surgery are 1.5% and 0.6% respectively, a lower rate than 2.3% and 0.9% respectively in 2006-2010. DVTs were significantly more prevalent after hip fracture surgery than after elective hip or knee arthroplasty, and 71% of DVTs were confined to the distal veins. Of the patients undergoing surgery, 93% received post-operative chemoprophylaxis, mainly aspirin or low molecular-weight heparin (LMWH). CONCLUSION: There has been a significant reduction in VTE rates following elective hip and knee joint replacement and hip fracture surgery between the time periods. This occurred over a period when Waitemata DHB introduced a multi-modal, interdisciplinary team approach to VTE prophylaxis utilising enhanced recovery after surgery (ERAS) pathways. These measures may therefore have contributed to the reduction in VTEs.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Hip Fractures/surgery , Postoperative Complications/epidemiology , Pulmonary Embolism/epidemiology , Venous Thromboembolism/epidemiology , Venous Thrombosis/epidemiology , Aged , Aged, 80 and over , Anticoagulants/therapeutic use , Aspirin/therapeutic use , Female , Heparin, Low-Molecular-Weight/therapeutic use , Humans , Incidence , Male , Medical Audit , New Zealand/epidemiology , Orthopedic Procedures , Platelet Aggregation Inhibitors/therapeutic use , Postoperative Complications/prevention & control , Pulmonary Embolism/prevention & control , Venous Thromboembolism/prevention & control , Venous Thrombosis/prevention & control , Warfarin/therapeutic use
3.
N Z Med J ; 132(1490): 17-25, 2019 02 22.
Article in English | MEDLINE | ID: mdl-30789885

ABSTRACT

AIM: Mortality rates of up to 38% at one year have been reported following surgery for neck of femur fractures. The aim of this review is to evaluate the post-operative mortality rates and trends over time for patients with fractured neck of femur at Waitemata District Health Board. METHOD: A retrospective cohort study of all patients who received surgery following a neck of femur fracture at Waitemata District Health Board between 2009 and 2016. Inpatient data was retrieved from electronic hospital records and mortality rates from the Ministry of Health, New Zealand. Analyses included crude mortality rates and trends over time, and time-to-theatre from presentation with neck of femur fracture. RESULTS: A total of 2,822 patients were included in the study; mean age 81.9 years, 70.4% female and 29.6% male. Overall post-operative crude rates for inpatient, 30-day and one-year mortality were 3.7%, 7.2% and 23.8% respectively. Adjusted analyses showed a statistically significant decrease in mortality rates between 2009 and 2016 at inpatient (p=0.001), 30 days (p=<0.001) and one year (p=<0.001) time periods. There was also a significant association between time-to-theatre and mortality at inpatient (p=0.002), 30 days (p=0.0001), and one year (p=0.0002) time periods. CONCLUSION: Mortality rates following surgery for fractured NOF have significantly improved over recent years at Waitemata District Health Board. Reduced time-to-theatre is associated with decreased inpatient, 30-day and one-year mortality.


Subject(s)
Femoral Neck Fractures , Fracture Fixation , Postoperative Complications/mortality , Aged , Aged, 80 and over , Cost of Illness , Female , Femoral Neck Fractures/economics , Femoral Neck Fractures/epidemiology , Femoral Neck Fractures/mortality , Femoral Neck Fractures/surgery , Fracture Fixation/methods , Fracture Fixation/rehabilitation , Fracture Fixation/statistics & numerical data , Humans , Incidence , Male , Middle Aged , Mortality , New Zealand/epidemiology , Outcome and Process Assessment, Health Care , Postoperative Period , Retrospective Studies , Risk Factors
5.
Clin Orthop Relat Res ; 475(1): 118-124, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27287857

ABSTRACT

BACKGROUND: Encouraging clinical results have been reported with the use of femoral head structural allografts and, more recently, trabecular metal cones for the management of large structural defects of the femur and tibia during revision total knee arthroplasty (TKA). However, to our knowledge, there are no published studies comparing these two techniques. QUESTIONS/PURPOSES: Compared with bulk allografts, do trabecular metal cones result in (1) better validated outcomes scores; (2) a lower risk of loosening or revision at 5 years; and (3) fewer surgical complications when used for the management of bone loss in revision TKA? METHODS: Between 2002 and 2008, three surgeons performed 450 TKA revisions, 45 (10%) of which were performed using augmentation of host bone; in those, femoral head allograft was used in 30 (75%) and trabecular metal cones in 15 (25%). From 2002 to 2007, femoral head allografts were used in all patients (28 patients); from 2007 to 2008, trabecular metal augments were used in all patients. There was a period of 1 year (16 knees) in which there was some overlap; during that time, femoral head structural allografts were used in cases in which we were unable to fit the defect or achieve adequate stability with trabecular metal cones. Followup was at a mean of 9 years (range, 5-12 years). No patients were lost to followup. Knee function and quality of life were assessed using the Oxford Knee Score, WOMAC, SF-12, and the UCLA activity score. Radiographs were assessed for signs of loosening. Surgical complications included superficial or deep infections, iatrogenic fractures, symptomatic deep venous thromboses or pulmonary emboli, and blood loss requiring transfusion; these were obtained from our database and from review of patients' charts. RESULTS: The mean Oxford Knee Score in the allograft and trabecular metal cone groups was 91 (SD 10) and 91 (SD 14), respectively (95% confidence interval [CI], 88-94; p = 0.29). Mean WOMAC scores were 94 (SD 10) and 92 (SD 14), respectively (95% CI, 80-105; p = 0.52) and mean UCLA scores were 6 (SD 1.2) and 6 (SD 1.5), respectively (95% CI, 4-8; p = 0.49). Five- and 10-year survivorship of the allografts was 93% (95% CI, 77-98) and 93% (95% CI, 77-99), respectively. Survivorship at a mean of 5 years in the trabecular metal cones group was 91% (95% CI, 56-98). With the numbers available, there were no differences between the groups in terms of the frequency of surgical complications (3% [one of 30] versus 7% [one of 15]; odds ratio, 0.5; p = 0.632). CONCLUSIONS: With the numbers available, we found no difference in pain, function, or repeat revision when comparing femoral head allografts and trabecular metal cones for severe bone defects during revision TKA. However, we used allografts for the larger bone defects. Based on these results, we believe that femoral head allografts and trabecular metal cones can both be used for the management of Anderson Orthopaedic Research Institute Types 2 and 3 defects. Future multicenter studies are required with larger numbers, cost analyses, and a longer duration of followup. LEVEL OF EVIDENCE: Level III, therapeutic study.


Subject(s)
Allografts , Arthroplasty, Replacement, Knee/methods , Bone Transplantation , Knee Joint/surgery , Knee Prosthesis , Prosthesis Failure , Adult , Aged , Aged, 80 and over , Female , Femur/surgery , Femur Head/surgery , Humans , Male , Middle Aged , Prosthesis Design , Quality of Life , Reoperation , Retrospective Studies , Tibia/surgery , Treatment Outcome
6.
J Shoulder Elbow Surg ; 24(6): 928-33, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25861852

ABSTRACT

BACKGROUND: The purpose of this study was to report the outcome of a large cohort of patients undergoing distal biceps tendon repair. We compared the endobutton and transosseous suture repair techniques, both performed through a 2-incision approach. METHOD: At an average of 2.1 years after a distal biceps repair, 46 male patients (19 endobutton and 27 transosseous suture) were reviewed. The mean age of our patients was 50 years. RESULTS: Forty-three patients (93%) were satisfied with the results of their distal biceps tendon repair. The average pain score was 1.3 of 10 at a mean 2.1 years after repair. More than 80% of patients had regained their premorbid function in both recreational and occupational activities. The mean Mayo Elbow Performance Score was 93 of 100. Biodex strength testing demonstrated restoration of 92% of low-velocity supination power, 102% of high-velocity supination power, and 104% endurance compared with the contralateral limb. There was no statistically significant difference in postoperative strength between the transosseous suture and endobutton groups. There were 3 complications in this series, 1 case of heterotopic ossification and 2 cases of injury to the lateral cutaneous nerve of the forearm. CONCLUSION: In this large cohort of 2-incision distal biceps repairs, we found a high degree of patient satisfaction and a low complication rate. We did not find any difference in clinical outcome with regard to subjective patient rating, pain, range of motion, or supination strength when comparing the 2-incision endobutton and transosseous suture fixation techniques.


Subject(s)
Muscle, Skeletal/injuries , Suture Techniques , Tendon Injuries/surgery , Adult , Aged , Elbow Joint , Female , Forearm , Humans , Male , Middle Aged , Muscle Strength , Patient Satisfaction , Range of Motion, Articular , Rupture/surgery , Supination , Suture Techniques/adverse effects
7.
Clin Orthop Relat Res ; 473(12): 3752-9, 2015 Dec.
Article in English | MEDLINE | ID: mdl-25910779

ABSTRACT

BACKGROUND: Templating is an important aspect of preoperative planning for total hip arthroplasty and can help determine the size and positioning of the prosthesis. Historically, templating has been performed using acetate templates over printed radiographs. As a result of the increasing use of digital imaging, surgeons now either obtain additional printed radiographs solely for templating purposes or use specialized digital templating software, both of which carry additional cost. QUESTIONS/PURPOSES: The purposes of this study was to compare acetate templating of digitally calibrated images on an LCD monitor to digital templating in terms of (1) accuracy; (2) reproducibility; and (3) time efficiency. METHODS: Acetate onlay templating was performed directly over digital radiographs on an LCD monitor and was compared with digital templating. Five separate observers participated in this study templating on 52 total hip arthroplasties. For the acetate templating, the digital images were magnified to the scaled reference on the templates provided by the manufacturer (ratio 1.2:1) before templating using a 25-mm marker as a reference. Both the acetate and digital templating results were then compared with the actual implanted components to determine accuracy. Interobserver and intraobserver variability was determined by an intraclass correlation coefficient. Observers recorded time to complete templating from the time of complete upload of patients' imaging onto the system to completion of templating. RESULTS: Both acetate and digital templates demonstrated moderate accuracy in predicting within one size of the eventual implanted acetabular cup (77% [199 of 260]; 70% [181 of 260], respectively; p = 0.050; 95% confidence interval [CI], 0.058-0.32), whereas acetate templating was better at predicting the femoral stem compared to digital templating (75% [195 of 260]; 60% [155 of 260], respectively; p < 0.001; 95% CI, 0.084-0.32). Acetate templating showed moderate to substantial interobserver agreement (cup intraclass correlation coefficient [ICC] = 0.55; 95% CI, 0.14-0.86; femoral ICC = 0.75; 95% CI, 0.39-0.95) and both methods showed almost perfect intraobserver agreement in reproducibility (acetate cup ICC = 0.82; 95% CI, 0.66-0.97; acetate femoral ICC = 0.86; 95% CI, 0.74-0.97; digital cup ICC = 0.82; 95% CI, 0.68-0.97; digital femoral ICC = 0.88; 95% CI, 0.77-1.0). Acetate templating could be performed more quickly (acetate mean 119 seconds; range, 37-220 seconds versus 154 seconds; range, 73-343 seconds; p < 0.001). CONCLUSIONS: Acetate onlay templating on digitally calibrated images can be a reliable substitute for digital templating using specialized software. It is quicker to perform and much less expensive. Hospitals and practices need not purchase expensive software, particularly at lower volume centers. LEVEL OF EVIDENCE: Level III, diagnostic study.


Subject(s)
Acetates , Arthroplasty, Replacement, Hip/instrumentation , Computer-Aided Design , Hip Joint/diagnostic imaging , Hip Joint/surgery , Hip Prosthesis , Osteoarthritis, Hip/diagnostic imaging , Osteoarthritis, Hip/surgery , Prosthesis Design , Radiographic Image Interpretation, Computer-Assisted/methods , Software , Anatomic Landmarks , Arthroplasty, Replacement, Hip/economics , Computer-Aided Design/economics , Cost-Benefit Analysis , Efficiency , Health Care Costs , Hip Prosthesis/economics , Humans , Observer Variation , Predictive Value of Tests , Prospective Studies , Prosthesis Design/economics , Reproducibility of Results , Workflow
9.
Surg Radiol Anat ; 35(2): 95-8, 2013 Mar.
Article in English | MEDLINE | ID: mdl-22875051

ABSTRACT

PURPOSE: Scapulothoracic bursitis is a painful condition of the scapulothoracic articulation, which may be caused by various pathological anatomical associations. We have arthroscopically observed a constant bare area of bone on the costal scapula surface in patients with scapulothoracic bursitis, contradictory to traditional anatomical reports of scapular muscle relations. We undertook a cadaveric study to further define this anatomical feature. METHODS: Twelve cadaveric shoulders were dissected. The costal surface of the scapula was systematically examined for the presence of a superomedial bare area in each shoulder by three independent clinicians, with dimensions measured using digital calipers. RESULTS: In all shoulders, there was a clearly defined bare area of bone on the superomedial aspect of the costal surface of the scapula between the serratus anterior insertion and subscapularis origin. The bare area was typically crescenteric in shape, with variable length (mean 22.3 ± 6.0 mm) and width (10.8 ± 2.8 mm). The bare area length (p = 0.043) and width (p = 0.033) were significantly greater in female shoulders compared to male shoulders. CONCLUSIONS: We have established the presence of the superomedial bare area of the costal scapula surface. With an absence of overlying subscapularis muscle, this bare area carries the potential for scapulothoracic impingement, and should be considered as a possible aetiological factor in all patients presenting with scapulothoracic bursitis.


Subject(s)
Body Weights and Measures/methods , Scapula/anatomy & histology , Aged , Aged, 80 and over , Bursitis/complications , Cadaver , Female , Humans , Joint Diseases/etiology , Joint Diseases/pathology , Male , Middle Aged , Observer Variation , Sex Factors , Shoulder Joint/anatomy & histology , Syndrome
SELECTION OF CITATIONS
SEARCH DETAIL
...