Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 36
Filter
1.
Acta Paediatr ; 2024 May 22.
Article in English | MEDLINE | ID: mdl-38775297

ABSTRACT

Over the past decades, music therapy in the neonatal intensive care unit (NICU) has been proven effective in physiological and psychological outcomes, including sucking, behaviour, stress reduction, neurodevelopment and promoting emotional bonding. However, not every NICU administers music therapy in their ward. Research on music therapy for neonates and their caregivers has lately accumulated, increasing the evidence of health benefits on brain development and across a variety of NICU-related pathologies, including neurological, cardiological, pulmonary and gastrointestinal problems. Conclusively, we will present the studied methods of music therapy for clinical benefits in neonatal intensive care.

2.
Int J Mol Sci ; 24(14)2023 Jul 16.
Article in English | MEDLINE | ID: mdl-37511288

ABSTRACT

Neonatal seizures are commonly associated with acute perinatal brain injury, while understanding regarding the downstream molecular pathways related to seizures remains unclear. Furthermore, effective treatment and reliable biomarkers are still lacking. Post-translational modifications can contribute to changes in protein function, and post-translational citrullination, which is caused by modification of arginine to citrulline via the calcium-mediated activation of the peptidylarginine deiminase (PAD) enzyme family, is being increasingly linked to neurological injury. Extracellular vesicles (EVs) are lipid-bilayer structures released from cells; they can be isolated from most body fluids and act as potential liquid biomarkers for disease conditions and response to treatment. As EVs carry a range of genetic and protein cargo that can be characteristic of pathological processes, the current study assessed modified citrullinated protein cargo in EVs isolated from plasma and CSF in a piglet neonatal seizure model, also following phenobarbitone treatment. Our findings provide novel insights into roles for PAD-mediated changes on EV signatures in neonatal seizures and highlight the potential of plasma- and CSF-EVs to monitor responses to treatment.


Subject(s)
Citrullination , Extracellular Vesicles , Infant, Newborn , Humans , Animals , Swine , Protein-Arginine Deiminases/metabolism , Protein Processing, Post-Translational , Biomarkers/metabolism , Extracellular Vesicles/metabolism , Seizures/metabolism
3.
Pediatr Res ; 94(5): 1675-1683, 2023 11.
Article in English | MEDLINE | ID: mdl-37308684

ABSTRACT

BACKGROUND: Opportunities for adjunct therapies with cooling in neonatal encephalopathy are imminent; however, robust biomarkers of early assessment are lacking. Using an optical platform of broadband near-infrared spectroscopy and diffuse correlation spectroscopy to directly measure mitochondrial metabolism (oxCCO), oxygenation (HbD), cerebral blood flow (CBF), we hypothesised optical indices early (1-h post insult) after hypoxia-ischaemia (HI) predicts insult severity and outcome. METHODS: Nineteen newborn large white piglets underwent continuous neuromonitoring as controls or following moderate or severe HI. Optical indices were expressed as mean semblance (phase difference) and coherence (spectral similarity) between signals using wavelet analysis. Outcome markers included the lactate/N-acetyl aspartate (Lac/NAA) ratio at 6 h on proton MRS and TUNEL cell count. RESULTS: CBF-HbD semblance (cerebrovascular dysfunction) correlated with BGT and white matter (WM) Lac/NAA (r2 = 0.46, p = 0.004, r2 = 0.45, p = 0.004, respectively), TUNEL cell count (r2 = 0.34, p = 0.02) and predicted both initial insult (r2 = 0.62, p = 0.002) and outcome group (r2 = 0.65 p = 0.003). oxCCO-HbD semblance (cerebral metabolic dysfunction) correlated with BGT and WM Lac/NAA (r2 = 0.34, p = 0.01 and r2 = 0.46, p = 0.002, respectively) and differentiated between outcome groups (r2 = 0.43, p = 0.01). CONCLUSION: Optical markers of both cerebral metabolic and vascular dysfunction 1 h after HI predicted injury severity and subsequent outcome in a pre-clinical model. IMPACT: This study highlights the possibility of using non-invasive optical biomarkers for early assessment of injury severity following neonatal encephalopathy, relating to the outcome. Continuous cot-side monitoring of these optical markers can be useful for disease stratification in the clinical population and for identifying infants who might benefit from future adjunct neuroprotective therapies beyond cooling.


Subject(s)
Hypoxia-Ischemia, Brain , Infant , Humans , Animals , Swine , Hypoxia-Ischemia, Brain/therapy , Neuroprotection , Biomarkers , Brain/metabolism , Animals, Newborn
4.
Epilepsia ; 64(2): 456-468, 2023 02.
Article in English | MEDLINE | ID: mdl-36398397

ABSTRACT

OBJECTIVE: To assess if early clinical and electroencephalography (EEG) features predict later seizure development in infants with hypoxic-ischemic encephalopathy (HIE). METHODS: Clinical and EEG parameters <12 h of birth from infants with HIE across eight European Neonatal Units were used to develop seizure-prediction models. Clinical parameters included intrapartum complications, fetal distress, gestational age, delivery mode, gender, birth weight, Apgar scores, assisted ventilation, cord pH, and blood gases. The earliest EEG hour provided a qualitative analysis (discontinuity, amplitude, asymmetry/asynchrony, sleep-wake cycle [SWC]) and a quantitative analysis (power, discontinuity, spectral distribution, inter-hemispheric connectivity) from full montage and two-channel amplitude-integrated EEG (aEEG). Subgroup analysis, only including infants without anti-seizure medication (ASM) prior to EEG was also performed. Machine-learning (ML) models (random forest and gradient boosting algorithms) were developed to predict infants who would later develop seizures and assessed using Matthews correlation coefficient (MCC) and area under the receiver-operating characteristic curve (AUC). RESULTS: The study included 162 infants with HIE (53 had seizures). Low Apgar, need for ventilation, high lactate, low base excess, absent SWC, low EEG power, and increased EEG discontinuity were associated with seizures. The following predictive models were developed: clinical (MCC 0.368, AUC 0.681), qualitative EEG (MCC 0.467, AUC 0.729), quantitative EEG (MCC 0.473, AUC 0.730), clinical and qualitative EEG (MCC 0.470, AUC 0.721), and clinical and quantitative EEG (MCC 0.513, AUC 0.746). The clinical and qualitative-EEG model significantly outperformed the clinical model alone (MCC 0.470 vs 0.368, p-value .037). The clinical and quantitative-EEG model significantly outperformed the clinical model (MCC 0.513 vs 0.368, p-value .012). The clinical and quantitative-EEG model for infants without ASM (n = 131) had MCC 0.588, AUC 0.832. Performance for quantitative aEEG (n = 159) was MCC 0.381, AUC 0.696 and clinical and quantitative aEEG was MCC 0.384, AUC 0.720. SIGNIFICANCE: Early EEG background analysis combined with readily available clinical data helped predict infants who were at highest risk of seizures, hours before they occur. Automated quantitative-EEG analysis was as good as expert analysis for predicting seizures, supporting the use of automated assessment tools for early evaluation of HIE.


Subject(s)
Hypoxia-Ischemia, Brain , Infant, Newborn , Humans , Infant , Hypoxia-Ischemia, Brain/complications , Hypoxia-Ischemia, Brain/diagnosis , Electroencephalography , ROC Curve , Lactic Acid , Gestational Age
5.
Front Pediatr ; 10: 1008539, 2022.
Article in English | MEDLINE | ID: mdl-36268041

ABSTRACT

Brain tissue temperature is a dynamic balance between heat generation from metabolism, passive loss of energy to the environment, and thermoregulatory processes such as perfusion. Perinatal brain injuries, particularly neonatal encephalopathy, and seizures, have a significant impact on the metabolic and haemodynamic state of the developing brain, and thereby likely induce changes in brain temperature. In healthy newborn brains, brain temperature is higher than the core temperature. Magnetic resonance spectroscopy (MRS) has been used as a viable, non-invasive tool to measure temperature in the newborn brain with a reported accuracy of up to 0.2 degrees Celcius and a precision of 0.3 degrees Celcius. This measurement is based on the separation of chemical shifts between the temperature-sensitive water peaks and temperature-insensitive singlet metabolite peaks. MRS thermometry requires transport to an MRI scanner and a lengthy single-point measurement. Optical monitoring, using near infrared spectroscopy (NIRS), offers an alternative which overcomes this limitation in its ability to monitor newborn brain tissue temperature continuously at the cot side in real-time. Near infrared spectroscopy uses linear temperature-dependent changes in water absorption spectra in the near infrared range to estimate the tissue temperature. This review focuses on the currently available methodologies and their viability for accurate measurement, the potential benefits of monitoring newborn brain temperature in the neonatal intensive care unit, and the important challenges that still need to be addressed.

6.
BMJ Open ; 12(9): e059946, 2022 09 21.
Article in English | MEDLINE | ID: mdl-36130761

ABSTRACT

INTRODUCTION: Hypoaccommodation is common in children born prematurely and those with hypoxic ischaemic encephalopathy (HIE), with the potential to affect wider learning. These children are also at risk of longer-term cerebral visual impairment. It is also well recognised that early intervention for childhood visual pathology is essential, because neuroplasticity progressively diminishes during early life. This study aims to establish the feasibility and acceptability of conducting a randomised controlled trial to test the effectiveness of early near vision correction with spectacles in infancy, for babies, at risk of visual dysfunction. METHODS AND ANALYSIS: This is a parallel group, open-label, randomised controlled (feasibility) study to assess visual outcomes in children with perinatal brain injury when prescribed near vision spectacles compared with the current standard care-waiting until a problem is detected. The study hypothesis is that accommodation, and possibly other aspects of vision, may be improved by intervening earlier with near vision glasses. Eligible infants (n=75, with either HIE or <29 weeks preterm) will be recruited and randomised to one of three arms, group A (no spectacles) and two intervention groups: B1 or B2. Infants in both intervention groups will be offered glasses with +3.00 DS added to the full cycloplegic refraction and prescribed for full time wear. Group B1 will get their first visit assessment and intervention at 8 weeks corrected gestational age (B1) and B2 at 16 weeks corrected gestational age. All infants will receive a complete visual and neurodevelopmental assessment at baseline and a follow-up visit at 3 and 6 months after the first visit. ETHICS AND DISSEMINATION: The South-Central Oxford C Research Ethics Committee has approved the study. Members of the PPI committee will give advice on dissemination of results through peer-reviewed publications, conferences and societies. TRIAL REGISTRATION NUMBER: ISRCTN14646770, NCT05048550, NIHR ref: PB-PG-0418-20006.


Subject(s)
Brain Diseases , Mydriatics , Brain Diseases/complications , Child , Early Intervention, Educational , Eyeglasses/adverse effects , Feasibility Studies , Humans , Infant , Infant, Newborn , Randomized Controlled Trials as Topic , Vision Disorders/etiology , Vision Disorders/therapy
7.
Cells ; 11(16)2022 08 21.
Article in English | MEDLINE | ID: mdl-36010678

ABSTRACT

BACKGROUND: Neonatal seizures remain a significant cause of morbidity and mortality worldwide. The past decade has resulted in substantial progress in seizure detection and understanding the impact seizures have on the developing brain. Optical monitoring such as cerebral near-infrared spectroscopy (NIRS) and broadband NIRS can provide non-invasive continuous real-time monitoring of the changes in brain metabolism and haemodynamics. AIM: To perform a systematic review of optical biomarkers to identify changes in cerebral haemodynamics and metabolism during the pre-ictal, ictal, and post-ictal phases of neonatal seizures. METHOD: A systematic search was performed in eight databases. The search combined the three broad categories: (neonates) AND (NIRS) AND (seizures) using the stepwise approach following PRISMA guidance. RESULTS: Fifteen papers described the haemodynamic and/or metabolic changes observed with NIRS during neonatal seizures. No randomised controlled trials were identified during the search. Studies reported various changes occurring in the pre-ictal, ictal, and post-ictal phases of seizures. CONCLUSION: Clear changes in cerebral haemodynamics and metabolism were noted during the pre-ictal, ictal, and post-ictal phases of seizures in neonates. Further studies are necessary to determine whether NIRS-based methods can be used at the cot-side to provide clear pathophysiological data in real-time during neonatal seizures.


Subject(s)
Epilepsy , Infant, Newborn, Diseases , Brain/metabolism , Epilepsy/metabolism , Humans , Infant, Newborn , Infant, Newborn, Diseases/metabolism , Seizures/diagnosis , Seizures/metabolism , Spectroscopy, Near-Infrared/methods
8.
Brain Sci ; 12(5)2022 Apr 29.
Article in English | MEDLINE | ID: mdl-35624965

ABSTRACT

Perinatal brain injury occurs in 5.14/1000 live births in England. A significant proportion of these injuries result from hypoxic ischaemic encephalopathy (HIE) in term infants and intracranial haemorrhage (IVH) or periventricular leukomalacia (PVL) in preterm infants. Standardised care necessitates minimal handling from parents and professionals to reduce the progression of injury. This can potentially increase parental stress through the physical inability to bond with their baby. Recent research highlights the ability of music therapy (MT) to empower parental bonding without handling, through sharing culturally informed personal music with their infant. This review therefore aimed to systematically evaluate the use of MT with infants diagnosed with perinatal brain injury in a neonatal intensive care unit (NICU). Search terms were combined into three categories (audio stimulation (MT), population (neonates) and condition (brain injury), and eight electronic databases were used to identify relevant studies following PRISMA guidelines. Eleven studies using music or vocal stimulation with infants diagnosed with perinatal brain injury were identified and quality assessed using Cochrane ROB2, the ROBINSI Tool and the Newcastle Ottawa Scale. Studies used either voice as live (n = 6) or pre-recorded (n = 3) interventions or pre-recorded instrumental music (n = 2). Studies had two primary areas of focus: developmental outcomes and physiological effects. Results suggested the use of music interventions led to a reduction of infants' pain scores during procedures and cardiorespiratory events, improved feeding ability (increase oral feeding rate, volume intake and feeds per day) and resulted in larger amygdala volumes than control groups. Additionally, MT intervention on the unit supported long-term hospitalised infants in the acquisition of developmental milestones. Vocal soothing was perceived to be an accessible intervention for parents. However, infants with PVL showed signs of stress in complex interventions, which also potentially resulted in an increase in maternal anxiety in one study. MT with infants diagnosed with perinatal brain injury can have positive effects on infants' behavioural and neurological parameters and support parental involvement in their infants' developmental care. Further feasibility studies are required using MT to determine appropriate outcome measures for infants and the support required for parents to allow future comparison in large-scale randomised control trials.

9.
Metabolites ; 12(3)2022 Mar 17.
Article in English | MEDLINE | ID: mdl-35323703

ABSTRACT

Epileptic seizures are transiently occurring symptoms due to abnormal excessive or synchronous neuronal activity in the brain. Previous functional near-infrared spectroscopy (fNIRS) studies during seizures have focused in only monitoring the brain oxygenation and haemodynamic changes. However, few tools are available to measure actual cellular metabolism during seizures, especially at the bedside. Here we use an in-house developed multichannel broadband NIRS (or bNIRS) system, that, alongside the changes in oxy-, deoxy- haemoglobin concentration (HbO2, HHb), also quantifies the changes in oxidised cytochrome-c-oxidase Δ(oxCCO), a marker of cellular oxygen metabolism, simultaneously over 16 different brain locations. We used bNIRS to measure metabolic activity alongside brain tissue haemodynamics/oxygenation during 17 epileptic seizures at the bedside of a 3-year-old girl with seizures due to an extensive malformation of cortical development in the left posterior quadrant. Simultaneously Video-EEG data was recorded from 12 channels. Whilst we did observe the expected increase in brain tissue oxygenation (HbD) during seizures, it was almost diminished in the area of the focal cortical dysplasia. Furthermore, in the area of seizure origination (epileptic focus) ΔoxCCO decreased significantly at the time of seizure generalization when compared to the mean change in all other channels. We hypothesize that this indicates an incapacity to sustain and increase brain tissue metabolism during seizures in the region of the epileptic focus.

10.
Front Pediatr ; 10: 1016211, 2022.
Article in English | MEDLINE | ID: mdl-36683815

ABSTRACT

Background and aims: Heart rate variability (HRV) has previously been assessed as a biomarker for brain injury and prognosis in neonates. The aim of this cohort study was to use HRV to predict the electroencephalography (EEG) grade in neonatal hypoxic-ischaemic encephalopathy (HIE) within the first 12 h. Methods: We included 120 infants with HIE recruited as part of two European multi-centre studies, with electrocardiography (ECG) and EEG monitoring performed before 12 h of age. HRV features and EEG background were assessed using the earliest 1 h epoch of ECG-EEG monitoring. HRV was expressed in time, frequency and complexity features. EEG background was graded from 0-normal, 1-mild, 2-moderate, 3-major abnormalities to 4-inactive. Clinical parameters known within 6 h of birth were collected (intrapartum complications, foetal distress, gestational age, mode of delivery, gender, birth weight, Apgar at 1 and 5, assisted ventilation at 10 min). Using logistic regression analysis, prediction models for EEG severity were developed for HRV features and clinical parameters, separately and combined. Multivariable model analysis included 101 infants without missing data. Results: Of 120 infants included, 54 (45%) had normal-mild and 66 (55%) had moderate-severe EEG grade. The performance of HRV model was AUROC 0.837 (95% CI: 0.759-0.914) and clinical model was AUROC 0.836 (95% CI: 0.759-0.914). The HRV and clinical model combined had an AUROC of 0.895 (95% CI: 0.832-0.958). Therapeutic hypothermia and anti-seizure medication did not affect the model performance. Conclusions: Early HRV and clinical information accurately predicted EEG grade in HIE within the first 12 h of birth. This might be beneficial when EEG monitoring is not available in the early postnatal period and for referral centres who may want some objective information on HIE severity.

11.
Clin Neurophysiol ; 132(9): 2091-2100, 2021 09.
Article in English | MEDLINE | ID: mdl-34284244

ABSTRACT

OBJECTIVE: Early prediction of neurological deficits following neonatal hypoxic-ischemic encephalopathy (HIE) may help to target support. Neonatal animal models suggest that recovery following hypoxia-ischemia depends upon cortical bursting. To test whether this holds in human neonates, we correlated the magnitude of cortical bursting during recovery (≥postnatal day 3) with neurodevelopmental outcomes. METHODS: We identified 41 surviving infants who received therapeutic hypothermia for HIE (classification at hospital discharge: 19 mild, 18 moderate, 4 severe) and had 9-channel electroencephalography (EEG) recordings as part of their routine care. We correlated burst power with Bayley-III cognitive, motor and language scores at median 24 months. To examine whether EEG offered additional prognostic information, we controlled for structural MRI findings. RESULTS: Higher power of central and occipital cortical bursts predicted worse cognitive and language outcomes, and higher power of central cortical bursts predicted worse motor outcome, all independently of structural MRI findings. CONCLUSIONS: Clinical EEG after postnatal day 3 may provide additional prognostic information by indexing persistent active mechanisms that either support recovery or exacerbate brain damage, especially in infants with less severe encephalopathy. SIGNIFICANCE: These findings could allow for the effect of clinical interventions in the neonatal period to be studied instantaneously in the future.


Subject(s)
Electroencephalography/trends , Hypothermia, Induced/trends , Hypoxia-Ischemia, Brain/diagnosis , Hypoxia-Ischemia, Brain/physiopathology , Survivors , Child Development/physiology , Female , Follow-Up Studies , Humans , Hypoxia-Ischemia, Brain/therapy , Infant, Newborn , Male , Prognosis , Retrospective Studies
12.
Front Pediatr ; 9: 653676, 2021.
Article in English | MEDLINE | ID: mdl-33898363

ABSTRACT

Neonatal encephalopathy (NE) in term and near-term infants is a significant global health problem; the worldwide burden of disease remains high despite the introduction of therapeutic hypothermia. Assessment of injury severity and effective management in the neonatal intensive care unit (NICU) relies on multiple monitoring modalities from systemic to brain-specific. Current neuromonitoring tools provide information utilized for seizure management, injury stratification, and prognostication, whilst systemic monitoring ensures multi-organ dysfunction is recognized early and supported wherever needed. The neuromonitoring technologies currently used in NE however, have limitations in either their availability during the active treatment window or their reliability to prognosticate and stratify injury confidently in the early period following insult. There is therefore a real need for a neuromonitoring tool that provides cot side, early and continuous monitoring of brain health which can reliably stratify injury severity, monitor response to current and emerging treatments, and prognosticate outcome. The clinical use of near-infrared spectroscopy (NIRS) technology has increased in recent years. Research studies within this population have also increased, alongside the development of both instrumentation and signal processing techniques. Increasing use of commercially available cerebral oximeters in the NICU, and the introduction of advanced optical measurements using broadband NIRS (BNIRS), frequency domain NIRS (FDNIRS), and diffuse correlation spectroscopy (DCS) have widened the scope by allowing the direct monitoring of oxygen metabolism and cerebral blood flow, both key to understanding pathophysiological changes and predicting outcome in NE. This review discusses the role of optical neuromonitoring in NE and why this modality may provide the next significant piece of the puzzle toward understanding the real time state of the injured newborn brain.

13.
Biomed Opt Express ; 12(2): 907-925, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33680549

ABSTRACT

Tissue oximetry with near-infrared spectroscopy (NIRS) is a technique for the measurement of absolute tissue oxygen saturation (StO2). Offering a real-time and non-invasive assessment of brain oxygenation and haemodynamics, StO2 has potential to be used for the assessment of newborn brain injury. Multiple algorithms have been developed to measure StO2, however, issues with low measurement accuracy or extracranial tissue signal contamination remain. In this work, we present a novel algorithm to recover StO2 in the neonate, broadband multidistance oximetry (BRUNO), based on a measurement of the gradient of attenuation against distance measured with broadband NIRS. The performance of the algorithm was compared to two other published algorithms, broadband fitting (BF) and spatially resolved spectroscopy (SRS). The median error when recovering StO2 in light transport simulations on a neonatal head mesh was 0.4% with BRUNO, 4.2% with BF and 9.5% with SRS. BRUNO was more sensitive to brain tissue oxygenation changes, shown in layered head model simulations. Comparison of algorithm performance during full oxygenation-deoxygenation cycles in a homogeneous dynamic blood phantom showed significant differences in the dynamic range of the algorithms; BRUNO recovered StO2 over 0-100%, BF over 0-90% and SRS over 39-80%. Recovering StO2 from data collected in a neonate treated at the neonatal intensive care showed different baseline values; mean StO2 was 64.9% with BRUNO, 67.2% with BF and 73.2% with SRS. These findings highlight the effect of StO2 algorithm selection on oxygenation recovery; applying BRUNO in the clinical care setting could reveal further insight into complex haemodynamic processes occurring during neonatal brain injury.

14.
Semin Fetal Neonatal Med ; 25(5): 101139, 2020 10.
Article in English | MEDLINE | ID: mdl-33223016

ABSTRACT

Hemodynamic impairment occurs in up to 80% of infants with neonatal encephalopathy (NE). Not all infants benefit from therapeutic hypothermia (HT); there are some indications that the trajectory of brain injury might be modified by neurologic monitoring and early management over the first 72-h period. It is also possible that optimizing hemodynamic management may further improve outomes. The coupling between cerebral blood flow and cerebral metabolism is disrupted in NE, increasing the vulnerability of the newborn brain to secondary injury. Hemodynamic monitoring is usually limited to blood pressure and functional echocardiographic measurements, which may not accurately reflect brain perfusion. This review explores the evidence base for hemodynamic assessment and management of infants with NE while undergoing HT. We discuss the literature behind a systematic approach to a baby with NE with the aim to define best therapies to optimize brain perfusion and reduce secondary injury.


Subject(s)
Hypothermia, Induced/methods , Hypoxia-Ischemia, Brain/physiopathology , Hypoxia-Ischemia, Brain/therapy , Brain/physiopathology , Cerebrovascular Circulation/physiology , Hemodynamics , Humans , Infant , Infant, Newborn , Infant, Newborn, Diseases/therapy
15.
Physiol Rep ; 8(17): e14548, 2020 09.
Article in English | MEDLINE | ID: mdl-32889790

ABSTRACT

Neonatal monitoring in neonatal intensive care is pushing the technological boundaries of newborn brain monitoring in order to improve patient outcome. There is an urgent need of a cot side, real time monitoring for assessment of brain injury severity and neurodevelopmental outcome, in particular for term newborn infants with hypoxic-ischemic brain injury. This topical review discusses why brain tissue metabolic monitoring is important in this group of infants and introduces the currently used neuromonitoring techniques for metabolic monitoring in the neonatal intensive care unit (NICU). New optical techniques that can monitor changes in brain metabolism together with brain hemodynamics at the cot side are presented. Early studies from these emerging technologies have demonstrated their potential to deliver continuous information regarding cerebral physiological changes in sick newborn infants in real time. The promises of these new tools as well as their potential limitations are discussed.


Subject(s)
Brain/metabolism , Intensive Care, Neonatal/methods , Neurophysiological Monitoring/methods , Spectroscopy, Near-Infrared/methods , Biomarkers/metabolism , Brain/diagnostic imaging , Electroencephalography/methods , Humans , Infant, Newborn , Magnetic Resonance Imaging/methods
16.
Lancet Child Adolesc Health ; 4(10): 740-749, 2020 10.
Article in English | MEDLINE | ID: mdl-32861271

ABSTRACT

BACKGROUND: Despite the availability of continuous conventional electroencephalography (cEEG), accurate diagnosis of neonatal seizures is challenging in clinical practice. Algorithms for decision support in the recognition of neonatal seizures could improve detection. We aimed to assess the diagnostic accuracy of an automated seizure detection algorithm called Algorithm for Neonatal Seizure Recognition (ANSeR). METHODS: This multicentre, randomised, two-arm, parallel, controlled trial was done in eight neonatal centres across Ireland, the Netherlands, Sweden, and the UK. Neonates with a corrected gestational age between 36 and 44 weeks with, or at significant risk of, seizures requiring EEG monitoring, received cEEG plus ANSeR linked to the EEG monitor displaying a seizure probability trend in real time (algorithm group) or cEEG monitoring alone (non-algorithm group). The primary outcome was diagnostic accuracy (sensitivity, specificity, and false detection rate) of health-care professionals to identify neonates with electrographic seizures and seizure hours with and without the support of the ANSeR algorithm. Neonates with data on the outcome of interest were included in the analysis. This study is registered with ClinicalTrials.gov, NCT02431780. FINDINGS: Between Feb 13, 2015, and Feb 7, 2017, 132 neonates were randomly assigned to the algorithm group and 132 to the non-algorithm group. Six neonates were excluded (four from the algorithm group and two from the non-algorithm group). Electrographic seizures were present in 32 (25·0%) of 128 neonates in the algorithm group and 38 (29·2%) of 130 neonates in the non-algorithm group. For recognition of neonates with electrographic seizures, sensitivity was 81·3% (95% CI 66·7-93·3) in the algorithm group and 89·5% (78·4-97·5) in the non-algorithm group; specificity was 84·4% (95% CI 76·9-91·0) in the algorithm group and 89·1% (82·5-94·7) in the non-algorithm group; and the false detection rate was 36·6% (95% CI 22·7-52·1) in the algorithm group and 22·7% (11·6-35·9) in the non-algorithm group. We identified 659 h in which seizures occurred (seizure hours): 268 h in the algorithm versus 391 h in the non-algorithm group. The percentage of seizure hours correctly identified was higher in the algorithm group than in the non-algorithm group (177 [66·0%; 95% CI 53·8-77·3] of 268 h vs 177 [45·3%; 34·5-58·3] of 391 h; difference 20·8% [3·6-37·1]). No significant differences were seen in the percentage of neonates with seizures given at least one inappropriate antiseizure medication (37·5% [95% CI 25·0 to 56·3] vs 31·6% [21·1 to 47·4]; difference 5·9% [-14·0 to 26·3]). INTERPRETATION: ANSeR, a machine-learning algorithm, is safe and able to accurately detect neonatal seizures. Although the algorithm did not enhance identification of individual neonates with seizures beyond conventional EEG, recognition of seizure hours was improved with use of ANSeR. The benefit might be greater in less experienced centres, but further study is required. FUNDING: Wellcome Trust, Science Foundation Ireland, and Nihon Kohden.


Subject(s)
Algorithms , Electroencephalography/methods , Machine Learning/statistics & numerical data , Monitoring, Physiologic/methods , Seizures/diagnosis , Electroencephalography/standards , Humans , Infant , Intensive Care, Neonatal , Ireland , Monitoring, Physiologic/standards , Netherlands , Seizures/prevention & control , Sweden , United Kingdom
17.
Front Neurol ; 11: 393, 2020.
Article in English | MEDLINE | ID: mdl-32536901

ABSTRACT

Background: Neonatal hypoxic ischemic encephalopathy (HIE) remains a significant cause of mortality and morbidity worldwide. Cerebral near infrared spectroscopy (NIRS) can provide cot side continuous information about changes in brain hemodynamics, oxygenation and metabolism in real time. Objective: To perform a systematic review of cerebral NIRS monitoring in term and near-term infants with HIE. Search Methods: A systematic search was performed in Ovid EMBASE and Medline database from inception to November 2019. The search combined three broad categories: measurement (NIRS monitoring), disease condition [hypoxic ischemic encephalopathy (HIE)] and subject category (newborn infants) using a stepwise approach as per PRISMA guidance. Selection Criteria: Only human studies published in English were included. Data Collection and Analysis: Two authors independently selected, assessed the quality, and extracted data from the studies for this review. Results: Forty-seven studies on term and near-term infants following HIE were identified. Most studies measured multi-distance NIRS based cerebral tissue saturation using monitors that are referred to as cerebral oximeters. Thirty-nine studies were published since 2010; eight studies were published before this. Fifteen studies reviewed the neurodevelopmental outcome in relation to NIRS findings. No randomized study was identified. Conclusion: Commercial NIRS cerebral oximeters can provide important information regarding changes in cerebral oxygenation and hemodynamics following HIE and can be particularly helpful when used in combination with other neuromonitoring tools. Optical measurements of brain metabolism using broadband NIRS and cerebral blood flow using diffuse correlation spectroscopy add additional pathophysiological information. Further randomized clinical trials and large observational studies are necessary with proper study design to assess the utility of NIRS in predicting neurodevelopmental outcome and guiding therapeutic interventions.

18.
Adv Exp Med Biol ; 1232: 3-9, 2020.
Article in English | MEDLINE | ID: mdl-31893387

ABSTRACT

Neonates with hypoxic-ischaemic (HI) brain injury were monitored using a broadband near-infrared spectroscopy (NIRS) system in the neonatal intensive care unit. The aim of this work is to use the NIRS cerebral oxygenation data (HbD = oxygenated-haemoglobin - deoxygenated-haemoglobin) combined with arterial saturation (SaO2) from pulse oximetry to calculate cerebral blood flow (CBF) based on the oxygen swing method, during spontaneous desaturation episodes. The method is based on Fick's principle and uses HbD as a tracer; when a sudden change in SaO2 occurs, the change in HbD represents a change in tracer concentration, and thus it is possible to estimate CBF. CBF was successfully calculated with broadband NIRS in 11 HIE infants (3 with severe injury) for 70 oxygenation events on the day of birth. The average CBF was 18.0 ± 12.7 ml 100 g-1 min-1 with a range of 4 ml 100 g-1 min-1 to 60 ml 100 g-1 min-1. For infants with severe HIE (as determined by magnetic resonance spectroscopy) CBF was significantly lower (p = 0.038, d = 1.35) than those with moderate HIE on the day of birth.


Subject(s)
Brain Injuries , Brain , Cerebrovascular Circulation , Oximetry , Oxygen , Spectroscopy, Near-Infrared , Brain/blood supply , Brain/diagnostic imaging , Brain Injuries/diagnostic imaging , Humans , Infant, Newborn , Oximetry/instrumentation , Oximetry/methods , Oxygen/metabolism
19.
Adv Exp Med Biol ; 1232: 25-31, 2020.
Article in English | MEDLINE | ID: mdl-31893390

ABSTRACT

Hypoxic ischemic encephalopathy (HIE) leads to significant mortality and morbidity, and therapeutic hypothermia (TH) has become a standard of care following HIE. After TH, the body temperature is brought back to 37 °C. Early electroencephalography (EEG) is a reliable outcome biomarker following HIE. We hypothesized that changes in cerebral oxidative metabolism, measured as Δ[oxCCO], in relation to changes in brain tissue oxygenation (measured as Δ[HbD]) during rewarming will correlate with injury severity as evidenced on amplitude integrated EEG/EEG at initial presentation. Broadband near-infrared spectroscopy (NIRS) and systemic data were collected during rewarming from 14 infants following HIE over a mean period of 12.5 h. All infants were monitored with video EEG telemetry using a standard neonatal montage. aEEG and EEG background was classified into mild, moderate and severely abnormal groups based on the background pattern. Two infants had mild, 6 infants had moderate and another 6 infants had severe abnormality at presentation. The relationship between [oxCCO] and [HbD] was evaluated between two groups of infants with abnormal electrical activity (mild vs moderate to severe). A significant difference was noted between the groups in the relationship between [oxCCO] and [HbD] (as r2) (p = 0.02). This result indicates that the mitochondrial injury and deranged oxidative metabolism persists in the moderate to severely abnormal group during rewarming.


Subject(s)
Electroencephalography , Hypothermia, Induced , Hypoxia-Ischemia, Brain , Biomarkers/analysis , Brain/metabolism , Humans , Hypoxia-Ischemia, Brain/diagnosis , Infant , Infant, Newborn , Rewarming
20.
Neurophotonics ; 6(4): 045009, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31737744

ABSTRACT

We describe the development of a miniaturized broadband near-infrared spectroscopy system (bNIRS), which measures changes in cerebral tissue oxyhemoglobin ( [ HbO 2 ] ) and deoxyhemoglobin ([HHb]) plus tissue metabolism via changes in the oxidation state of cytochrome-c-oxidase ([oxCCO]). The system is based on a small light source and a customized mini-spectrometer. We assessed the instrument in a preclinical study in 27 newborn piglets undergoing transient cerebral hypoxia-ischemia (HI). We aimed to quantify the recovery of the HI insult and estimate the severity of the injury. The recovery in brain oxygenation ( Δ [ HbDiff ] = Δ [ HbO 2 ] - Δ [ HHb ] ), blood volume ( Δ [ HbT ] = Δ [ HbO 2 ] + Δ [ HHb ] ), and metabolism ( Δ [ oxCCO ] ) for up to 30 min after the end of HI were quantified in percentages using the recovery fraction (RF) algorithm, which quantifies the recovery of a signal with respect to baseline. The receiver operating characteristic analysis was performed on bNIRS-RF measurements compared to proton ( H 1 ) magnetic resonance spectroscopic (MRS)-derived thalamic lactate/N-acetylaspartate (Lac/NAA) measured at 24-h post HI insult; Lac/NAA peak area ratio is an accurate surrogate marker of neurodevelopmental outcome in babies with neonatal HI encephalopathy. The Δ [ oxCCO ] -RF cut-off threshold of 79% within 30 min of HI predicted injury severity based on Lac/NAA with high sensitivity (100%) and specificity (93%). A significant difference in thalamic Lac/NAA was noticed ( p < 0.0001 ) between the two groups based on this cut-off threshold of 79% Δ [ oxCCO ] -RF. The severe injury group ( n = 13 ) had ∼ 30 % smaller recovery in Δ [ HbDiff ] -RF ( p = 0.0001 ) and no significant difference was observed in Δ [ HbT ] -RF between groups. At 48 h post HI, significantly higher P 31 -MRS-measured inorganic phosphate/exchangeable phosphate pool (epp) ( p = 0.01 ) and reduced phosphocreatine/epp ( p = 0.003 ) were observed in the severe injury group indicating persistent cerebral energy depletion. Based on these results, the bNIRS measurement of the oxCCO recovery fraction offers a noninvasive real-time biomarker of brain injury severity within 30 min following HI insult.

SELECTION OF CITATIONS
SEARCH DETAIL
...