Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Radiat Isot ; 88: 198-202, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24412425

ABSTRACT

A feasibility study on liquid lithium target in the form of a flowing film was performed to evaluate its potential use as a neutron generation target of (7)Li(p,n)(7)Be reaction in BNCT. The target is a windowless-type flowing film on a concave wall. Its configuration was adapted for a proton beam which is 30mm in diameter and with energy and current of up to 3MeV and 20mA, respectively. The flowing film of liquid lithium was 0.6mm in thickness, 50mm in width and 50mm in length. The shapes of the nozzle and concave back wall, which create a stable flowing film jet, were decided based on water experiments. A lithium hydrodynamic experiment was performed to observe the stability of liquid lithium flow behavior. The flowing film of liquid lithium was found to be feasible at temperatures below the liquid lithium boiling saturation of 342°C at the surface pressure of 1×10(-3)Pa. Using a proto-type liquid lithium-circulating loop for BNCT, the stability of the film flow was confirmed for velocities up to 30m/s at 220°C and 250°C in vacuum at a pressure lower than 10(-3) Pa. It is expected that for practical use, a flowing liquid lithium target of a windowless type can solve the problem of radiation damage and target cooling.


Subject(s)
Beryllium/chemistry , Boron Neutron Capture Therapy/instrumentation , Lithium/chemistry , Membranes, Artificial , Particle Accelerators/instrumentation , Radiometry/instrumentation , Beryllium/radiation effects , Equipment Design , Equipment Failure Analysis , Lithium/radiation effects , Materials Testing , Neutrons , Radiotherapy Dosage , Solutions
2.
Leg Med (Tokyo) ; 8(3): 166-71, 2006 May.
Article in English | MEDLINE | ID: mdl-16621652

ABSTRACT

A simultaneous determination method of quaternary amino steroidal muscle relaxants, pancuronium (PAN), vecuronium (VEC), and 17-monodesacetyl pancuronium (17-OH-PAN), 3,17-bisdesacetyl pancuronium (3,17-OH-PAN), 3-monodesacetyl vecuronium (3-OH-VEC), 3,17-bisdesacetyl vecuronium (3,17-OH-VEC) in human serum was developed using liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS). The weak cation exchange cartridge was useful for the extraction of these compounds. Under optimized LC-ESI-MS conditions, these compounds were almost fully separated within 6.5 min. Linear responses over the concentration range 0.25-50.0 ng/mL were demonstrated for each compound. The developed method successfully detected VEC, 3-OH-VEC and 3,17-OH-VEC in serum intravenously administered with VEC. The level of 3-OH-VEC was higher than other compounds. This suggested that 3-OH-VEC was useful as a forensic probe in VEC administration.


Subject(s)
Chromatography, Liquid , Neuromuscular Nondepolarizing Agents/blood , Pancuronium/blood , Spectrometry, Mass, Electrospray Ionization , Vecuronium Bromide/blood , Female , Forensic Medicine , Humans , Pancuronium/analogs & derivatives , Vecuronium Bromide/analogs & derivatives
SELECTION OF CITATIONS
SEARCH DETAIL
...