Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 46
Filter
1.
Technol Health Care ; 2024 May 22.
Article in English | MEDLINE | ID: mdl-38820037

ABSTRACT

BACKGROUND: A gradually reducing radius (GRADIUS) design implant can facilitate a smooth transition from stability through full range of motion in total knee arthroplasty (TKA). Nonetheless, patient-specific factors associated with good knee flexion remain unclear. OBJECTIVE: This study aimed to determine the factors associated with good knee flexion after cruciate-retaining TKA with a GRADIUS prosthesis in an Asian population. METHODS: This retrospective study included 135 patients that were stratified according to postoperative knee flexion angle (KFA) into Group F (⩾ 120∘; 85 patients [63.2%]) and Group NF (< 120∘; 50 patients [36.8%]). RESULTS: Patients in Group F were taller and had a lower body mass index (BMI) smaller preoperative hipkneeankle angle and better preoperative extension and flexion angle than Group NF patients. The multivariable analysis revealed that patients' height (odds ratio [OR]: 1.07, P= 0.0150), BMI (OR: 0.85, P= 0.0049), and preoperative flexion angle (OR: 1.06, P= 0.0008) predicted good KFA. The ROC curve analysis showed that the cutoff values of a good KFA were height 155.1 cm, BMI 22.1 kg/m2, and preoperative KFA 120∘. CONCLUSIONS: Patient height, BMI, and preoperative KFA were independent factors affecting good postoperative KFA in patients of Asian descent who underwent cruciate-retaining TKA with a GRADIUS design.

2.
Arch Osteoporos ; 19(1): 44, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38816657

ABSTRACT

PURPOSE: A history of fractures involving the distal radius, proximal humerus, spine, and hip may be associated with the incidence of subsequent hip fractures in older people. However, a comprehensive summary of this association using a rigorous methodology is lacking. Our objective was to systematically review the literature and examine the association between four major osteoporotic fractures and subsequent hip fractures in individuals aged ≥ 50 years. METHODS: We searched MEDLINE, Embase, CENTRAL, ICTRP, and ClinicalTrials.gov on February 15, 2023. The search included cohort or case-control studies investigating the association between these four types of osteoporotic fractures and subsequent hip fractures. We pooled the hazard ratios (HRs) with 95% confidence intervals (CI) using the random-effects model. We used the Quality In Prognosis Studies tool to assess the risk of bias in the included studies, and the grading of recommendations assessment, development, and evaluation approach to determine the certainty of evidence. RESULTS: The selection process identified 48 studies for qualitative synthesis and 23 studies (2,239,217 participants) for meta-analysis. The overall methodological quality had a low risk of bias in 65% of the included studies. The association between a history of major osteoporotic fractures and subsequent hip fracture varied, with a high certainty of evidence for a history of proximal humerus and hip fractures (HR 2.02, 95% CI 1.75-2.33 and 2.86, 95% CI 1.92-4.25, respectively), moderate certainty for distal radius fractures (HR 1.66, 95% CI 1.53-1.81), and low certainty for spine fractures (HR 1.53, 95% CI 1.38-1.69). CONCLUSIONS: In conclusion, a history of major osteoporotic fractures, particularly distal radius, proximal humerus, and hip fractures, is associated with subsequent hip fractures in older adults. Further research is needed to verify the association between a history of spine fracture and subsequent hip fractures. PROTOCOL REGISTRATION: Open Science Framework ( https://osf.io/7fjuc ).


Subject(s)
Hip Fractures , Osteoporotic Fractures , Humans , Hip Fractures/epidemiology , Osteoporotic Fractures/epidemiology , Aged , Incidence , Risk Factors
3.
Ann Emerg Med ; 83(6): 522-538, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38385910

ABSTRACT

STUDY OBJECTIVE: We conducted a systematic review and network meta-analysis to evaluate the comparative efficacy of peripheral nerve block types for preoperative pain management of hip fractures. METHODS: We searched Cochrane, Central Register of Controlled Trials, MEDLINE, EMBASE, ICTRP, ClinicalTrials.gov, and Google Scholar for randomized clinical trials. We included participants aged more than 16 years with hip fractures who received peripheral nerve blocks or analgesics for preoperative pain management. The primary outcomes were defined as absolute pain score 2 hours after block placement, preoperative consumption of morphine equivalents, and length of hospital stay. We used a random-effects network meta-analysis conceptualized in the Bayesian framework. Confidence of evidence was assessed using Confidence in Network Meta-Analysis (CINeMA). RESULTS: We included 63 randomized controlled studies (4,778 participants), of which only a few had a low risk of bias. The femoral nerve block, 3-in-1 block, fascia iliaca compartment block, and pericapsular nerve group block yielded significantly lowered pain scores at 2 hours after block placement compared with those with no block (standardized mean differences [SMD]: -1.1; 95% credible interval [CrI]: -1.7 to -0.48, [confidence of evidence: low]; SMD: -1.8; 95% CrI: -3.0 to -0.55, [low]; SMD: -1.4; 95% CrI: -2.0 to -0.72, [low]; SMD: -2.3; 95% CrI: -3.2 to -1.4, [moderate], respectively). The pericapsular nerve group block, 3-in-1 block, fascia iliaca compartment block, and femoral nerve block resulted in lower pain scores than the no-block group. Additionally, the pericapsular nerve group block yielded a lower pain score than femoral nerve block or fascia iliaca compartment block (SMD: -1.21; 95% CrI: -2.18 to -0.23, [very low]: SMD: -0.92; 95% CrI: -1.70 to -0.16, [low]). However, both the fascia iliaca compartment block and femoral nerve block did not show a reduction in morphine consumption compared with no block. To our knowledge, no studies have compared the pericapsular nerve group block with other methods regarding morphine consumption. Furthermore, no significant difference was observed between peripheral nerve blocks and no block in terms of the length of hospital stay. CONCLUSIONS: Compared with no block, preoperative peripheral nerve blocks for hip fractures appear to reduce pain 2 hours after block placement. Comparing different blocks, pericapsular nerve group block might be superior to fascia iliaca compartment block and femoral nerve block for pain relief, though the confidence evidence was low in most comparisons because of the moderate to high risk of bias in many of the included studies and the high heterogeneity of treatment strategies across studies. Therefore, further high-quality research is needed.


Subject(s)
Hip Fractures , Nerve Block , Pain Management , Humans , Hip Fractures/surgery , Nerve Block/methods , Pain Management/methods , Preoperative Care/methods , Network Meta-Analysis , Pain Measurement , Randomized Controlled Trials as Topic , Femoral Nerve , Length of Stay
4.
J Synchrotron Radiat ; 31(Pt 2): 276-281, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38385278

ABSTRACT

A high-flux sub-micrometre focusing system was constructed using multilayer focusing mirrors in Kirkpatrick-Baez geometry for 100 keV X-rays. The focusing mirror system had a wide bandwidth of 5% and a high peak reflectivity of 74%. Performance was evaluated at the undulator beamline BL05XU of SPring-8, which produced an intense 100 keV X-ray beam with a bandwidth of 1%. When the light source was focused directly in both vertical and horizontal directions, the beam size was measured to be 0.32 µm (V) × 5.3 µm (H) with a flux of 1 × 1012 photons s-1. However, when a limited horizontal slit was used to form a secondary source, the focusing beam size decreased to 0.25 µm (V) × 0.26 µm (H) with a flux of 6 × 1010 photons s-1. The 200 nm line and space patterns of a Siemens star chart made of tantalum were clearly resolved by the absorption contrast of the focused beam. This 100 keV focusing system is applicable to various fields of nondestructive analyses with sub-micrometre resolutions.

5.
Br J Anaesth ; 132(5): 1097-1111, 2024 May.
Article in English | MEDLINE | ID: mdl-37806932

ABSTRACT

BACKGROUND: Preprocedural, real-time, and computer-aided three-dimensional ultrasound has been widely used for neuraxial puncture; however, the optimal guidance is unclear. We examined the comparative efficacy of three ultrasound guidance and anatomical landmarks for neuraxial puncture in adults. METHODS: We searched for randomised controlled studies comparing the efficacy of ultrasound guidance and anatomical landmarks for neuraxial puncture in adults using electronic databases and unpublished studies. The primary outcomes were first-pass success and patient satisfaction. A random-effects network meta-analysis (NMA) was used. RESULTS: We identified 74 eligible studies (7090 patients). Preprocedural ultrasound and real-time ultrasound-guided neuraxial puncture improved first-pass success compared with anatomical landmarks (risk ratio [RR] 1.6; 95% credible interval [CrI] 1.3-1.9; RR 1.9; 95% CrI 1.3-2.9, respectively, moderate confidence). Computer-aided ultrasound-guided neuraxial puncture also increased first-pass success (RR 1.8; 95% CrI 0.97-3.3, low confidence), although estimates were imprecise. However, real-time ultrasound-guided neuraxial puncture resulted in minimal difference in first-pass success compared with preprocedural ultrasound (RR 1.2; 95% CrI 0.8-1.8, moderate confidence). Preprocedural ultrasound improved patient satisfaction slightly compared with anatomical landmark use (standardised mean differences 0.28; 95% CrI 0.092-0.47, low confidence). CONCLUSIONS: This NMA provides evidence supporting ultrasound-guided neuraxial puncture compared with use of anatomical landmarks, including indirect comparisons. Among the three ultrasound guidance methods, preprocedural ultrasound appears to be a better adjunctive option.

6.
Med Princ Pract ; 33(1): 10-20, 2024.
Article in English | MEDLINE | ID: mdl-38104544

ABSTRACT

OBJECTIVES: Atypical femoral fracture (AFF) is an atypical low-energy subtrochanteric and diaphyseal femoral fracture. Even if bone fusion is achieved in patients with AFF, the risk of AFF in the contralateral femur must be considered. This study aimed to investigate the factors affecting complete AFF in the contralateral femur and conservatively treated incomplete AFF. SUBJECT AND METHODS: Radiographs of 111 femurs in 104 AFF cases were examined, and the femurs were classified as follows: 85 contralateral femurs with complete AFF; 18 contralateral femurs with incomplete AFF; 8 femurs with incomplete AFF without surgical treatment. Various patients' clinical data were collected, and we investigated the factors affecting the second complete AFF. RESULTS: Complete fractures occurred in 10 (9.7%) of 103 femurs without incomplete AFF at the first visit and in 3 (37.5%) of 8 femurs with incomplete AFF. The Kaplan-Meier curve revealed that lateral cortical bone thickening and thigh pain were associated with significantly poorer prognoses (p = 0.026 and p = 0.013, respectively). Multivariate analyses revealed that eldecalcitol usage after AFF onset (p = 0.0094) and previous use of bisphosphonate or denosumab (p = 0.0126) were protective factors for second complete AFF and that the presence of thigh pain (p = 0.0134) was a risk factor for second complete AFF. CONCLUSIONS: Eldecalcitol administration after bone union of first AFF may prevent AFF recurrence. In addition, painful incomplete AFF has a high risk of developing a complete fracture.


Subject(s)
Bone Density Conservation Agents , Femoral Fractures , Humans , Bone Density Conservation Agents/therapeutic use , Diphosphonates/therapeutic use , Femoral Fractures/diagnostic imaging , Femoral Fractures/surgery , Femoral Fractures/drug therapy , Femur , Pain/drug therapy
7.
J Clin Med ; 12(22)2023 Nov 10.
Article in English | MEDLINE | ID: mdl-38002638

ABSTRACT

This study aimed to define basicervical and transcervical shear fractures using area classification and to determine the optimal osteosynthesis implants for them. The clinical outcomes of 1042 proximal femur fractures were investigated. A model of the proximal femur of a healthy adult was created from computed tomography images, and basicervical and transcervical shear fractures were established in the model. Osteosynthesis models were created using a short femoral nail with a single lag screw or two lag screws and a long femoral nail with a single lag screw or two lag screws. The minimum principal strains of the fracture surfaces were compared when the maximum loads during walking were applied to these models using finite element analysis software. Basicervical fractures accounted for 0.96% of all proximal femur fractures, 67% of which were treated with osteosynthesis; the failure rate was 0%. Transcervical shear fractures accounted for 9.6% of all proximal femur fractures, 24% of which were treated with osteosynthesis; the failure rate was 13%. Finite element analysis showed that transcervical shear fracture has high instability. To perform osteosynthesis, multiple screw insertions into the femoral head and careful postoperative management are required; joint replacement should be considered to achieve early mobility.

8.
J Clin Med ; 12(22)2023 Nov 10.
Article in English | MEDLINE | ID: mdl-38002645

ABSTRACT

Systematic reviews (SRs) with complete reporting or rigorous methods can lead to less biased recommendations and decisions. A comprehensive analysis of the epidemiological and reporting characteristics of SRs in orthopedics is lacking. We evaluated 360 SRs, including 165 and 195 published in orthopedic journals in 2012 and 2022. According to the established reporting guidelines, we examined these SRs for key epidemiological characteristics, including focus areas, type of meta-analysis (MA), and reporting characteristics. Most SRs (71%) were therapy-related, with a significant proportion originating from authors in the USA, UK, and China. Pairwise MA was performed on half of the SRs. The proportion of protocol registrations improved by 2022 but remained low (33%). Despite a formal declaration of adherence to the reporting guidelines (68%), they were often not used and reported enough. Only 10% of the studies used full search strategies, including trial registries. Publication bias assessments, subgroup analyses, and sensitivity analyses were not even planned. The risk of bias assessment improved in 2022; however, the certainty of the evidence remained largely unassessed (8%). The use and reporting of standard methods in orthopedic SRs have remained suboptimal. Thus, authors, peer reviewers, journal editors, and readers should criticize the results more.

9.
J Clin Med ; 12(16)2023 Aug 13.
Article in English | MEDLINE | ID: mdl-37629311

ABSTRACT

Recently, there has been increasing interest in medial meniscal extrusion (MME), but few reports have evaluated MME via X-ray. In this study, the amount of MME and meniscal height at the medial border of the tibia were measured via X-ray with gradation processing. The extrusion length divided by the meniscal height yields the meniscal extrusion ratio, which was used as an index. In addition, the medial meniscal length of the part protruding from the medial border of the tibia on MRI was measured as an absolute value. Then, the correlation between the meniscal extrusion ratio and the amount of MME on MRI was examined, and there was a strong correlation between the meniscal extrusion ratio via X-ray and the amount of MME on MRI (correlation coefficient 0.860, p < 0.0001). The cut-off value of the meniscal extrusion ratio via X-ray for positive meniscal extrusion on MRI was 0.50, with an AUC of 0.9825, sensitivity of 0.9063, and specificity of 0.8663. From the present study, it was possible to measure the extrusion length and meniscal height via gradation processing, with X-ray and without MRI, and to calculate the meniscal extrusion ratio, which strongly correlates with the amount of MME on MRI.

10.
J Telemed Telecare ; : 1357633X231181632, 2023 Jul 07.
Article in English | MEDLINE | ID: mdl-37416946

ABSTRACT

INTRODUCTION: This study aimed to determine the efficacy of telerehabilitation for patients after hip fracture surgery through a systematic review and meta-analysis. METHODS: Eight electronic databases were searched in August 2022. The primary outcomes were mobility outcomes, activities of daily living (ADL) outcomes, and all adverse events, whereas the secondary outcomes were pain, health-related quality of life, and fall efficacy scale score. RESULTS: Seven randomized controlled trials were eligible for this study. The evidence regarding the effect of telerehabilitation on mobility outcomes (standardized mean difference (SMD): 0.05, 95% confidence interval (CI): -0.39 to 0.48) and all adverse events (risk ratio: 1.14, 95% CI: 0.62 to 2.21) was very uncertain. A clinically irrelevant but significant mean difference (MD) in ADL outcomes was found (MD: 4.82, 95% CI: 2.63 to 7.01). Telerehabilitation may result in a slight increase in fall efficacy scale score (SMD: 0.26, 95% CI: -0.02 to 0.54) and little to no difference in pain (MD: -1.0, 95% CI: -18.31 to 16.31). CONCLUSIONS: The efficacy of telerehabilitation for patients after hip fracture surgery was uncertain with respect to the mobility outcomes, all adverse events, and pain, with no clinically meaningful differences in ADL outcomes. Telerehabilitation may be necessary to be considered for patients after hip fracture surgery to improve their confidence in their ability to perform daily activities without falling. Therefore, medical staff may consider telerehabilitation for hip fractures.

11.
Acta Med Okayama ; 77(3): 311-318, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37357632

ABSTRACT

Japan's hip fracture management guidelines now recommend the use of cemented stems in cases of bone fragility. However, the current stem selection practices in bipolar hemiarthroplasty (BHA) in a super-aging area in Japan remain unclear. This study aimed to examine the stem selection policies, the surgeons' concerns about cemented stems, and factors affecting their confidence in their ability to coach others on cemented stem procedures. Ninety-four orthopedic surgeons (27 facilities) responded to our web-based questionnaire conducted in January/February 2022. Cementless stem was the first choice of 97.8% of the surgeons; <15% of the respondents expected to increase their use of cemented stems in the future. The cement technique was the greatest concern; almost half of the surgeons described having insufficient experience with cemented stems. The factor that most affected the surgeons' expertise in using cemented stems is the number of surgeries they had conducted with a cemented stem (multivariable analysis odds ratio 8.42, p=0.001). Greater experience was associated with increased expertise of the surgeons in using cemented stems, with a threshold of 11 cases showing sensitivity of 41.7% and specificity of 98.3% for their confidence to instruct cemented stems.


Subject(s)
Arthroplasty, Replacement, Hip , Hemiarthroplasty , Hip Fractures , Hip Prosthesis , Surgeons , Humans , Aged , Arthroplasty, Replacement, Hip/methods , Hemiarthroplasty/methods , Japan , Reoperation , Prosthesis Design , Hip Fractures/surgery , Bone Cements , Surveys and Questionnaires
12.
BMC Musculoskelet Disord ; 24(1): 322, 2023 Apr 24.
Article in English | MEDLINE | ID: mdl-37095485

ABSTRACT

BACKGROUND: Mechanically aligned total knee arthroplasty (MATKA) is a well-established procedure. Kinematically aligned TKA (KATKA) has been proposed to restore and preserve pre-arthritic knee anatomy. However, normal knee anatomy varies widely, and there have been concerns regarding restoring unusual anatomy. Accordingly, restricted KATKA (rKATKA) was introduced to reproduce constitutional knee anatomy within a safe range. This network meta-analysis (NMA) aimed to evaluate the clinical and radiological outcomes of the surgeries. METHODS: We performed a database search on August 20, 2022, which included randomized controlled trials (RCTs) comparing any two of the three surgical TKA techniques for knee osteoarthritis. We conducted a random-effects NMA within the frequentist framework and evaluated confidence in each outcome using the Confidence in Network Meta-Analysis tool. RESULTS: Ten RCTs with 1,008 knees and a median follow-up period of 1.5 years were included. The three methods might result in little to no difference in range of motion (ROM) between methods. In patient-reported outcome measures (PROMs), the KATKA might result in a slight improvement compared with the MATKA (standardized mean difference, 0.47; 95% confidence interval [CI], 0.16-0.78; very low confidence). There was little to no difference in revision risk between MATKA and KATKA. KATKA and rKATKA showed a slight valgus femoral component (mean difference [MD], -1.35; 95% CI, -1.95-[-0.75]; very low confidence; and MD, -1.72; 95% CI, -2.63-[-0.81]; very low confidence, respectively) and a slight varus tibial component (MD, 2.23; 95% CI, 1.22-3.24; very low confidence; and MD, 1.25; 95% CI, 0.01-2.49; very low confidence, respectively) compared with MATKA. Tibial component inclination and hip-knee-ankle angle might result in little to no difference between the three procedures. CONCLUSIONS: KATKA and rKATKA showed similar ROM and PROMs and a slight variation in the coronal component alignment compared with MATKA. KATKA and rKATKA are acceptable methods in short- to mid-term follow-up periods. However, long-term clinical results in patients with severe varus deformity are still lacking. Surgeons should choose surgical procedures carefully. Further trials are warranted to evaluate the efficacy, safety, and subsequent revision risk.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Network Meta-Analysis , Biomechanical Phenomena , Randomized Controlled Trials as Topic , Knee Joint/surgery , Osteoarthritis, Knee/surgery
14.
Endocr J ; 70(2): 149-159, 2023 Feb 28.
Article in English | MEDLINE | ID: mdl-36198615

ABSTRACT

Metformin, an oral medication, is prescribed to patients with type 2 diabetes mellitus. Although the efficacy, safety, and low economic burden of metformin on patients have long been recognized, approximately 5% of the patients treated with this drug develop severe diarrhea and discontinue the treatment. We previously reported that 1,000 mg·kg-1·day-1 of metformin induced diarrhea in diabetic obese (db/db) mice and wood creosote (traditional medication for diarrhea) ameliorated the symptoms. In this study, we attempted to elucidate the molecular mechanisms by which metformin induces diarrhea. Cystic fibrosis transmembrane conductance regulator (CFTR) is a key ion (chloride) channel in cyclic adenosine monophosphate (cAMP)-induced diarrhea. Metformin treatment increased bile flow (bile acids and bilirubin) in the ileum of mice. In addition, the treatment was accompanied by an increase in mRNA and protein levels of CFTR in the mucosa of the ileum and colon in both wild-type (C57BL/6J) and db/db mice. Glucagon-like peptide-1 (GLP-1), as well as cholic acid, induces CFTR mRNA expression in human colon carcinoma Caco-2 cells through cAMP signaling. Although wood creosote (10 mg/kg) ameliorated diarrhea symptoms, it did not alter the mRNA levels of Glp-1 or Cftr. Similar to overeating, metformin upregulated GLP-1 and CFTR expression, which may have contributed to diarrhea symptoms in mice. Although we could not identify db/db mouse-specific factors associated with metformin-induced diarrhea, these factors may modulate colon function. Wood creosote may not interact with these factors but ameliorates diarrhea symptoms.


Subject(s)
Diabetes Mellitus, Type 2 , Metformin , Mice , Humans , Animals , Cystic Fibrosis Transmembrane Conductance Regulator/genetics , Caco-2 Cells , Glucagon-Like Peptide 1 , Creosote , Mice, Inbred C57BL , Cyclic AMP/metabolism , Colon/metabolism , Diarrhea/metabolism , RNA, Messenger , Ileum/metabolism
15.
Article in English | MEDLINE | ID: mdl-36554333

ABSTRACT

The intervertebral disc loading based on compensated standing posture in patients with adult spinal deformity remains unclear. We analyzed the relationship between sagittal alignment and disc compression force (Fm). In 14 elderly women, the alignment of the sagittal spinopelvic and lower extremities was measured. Fm was calculated using the Anybody Modeling System. Patients were divided into low sagittal vertical axis (SVA) and high SVA groups. Comparisons between the two groups were performed and the relationship between the Fm and each parameter was examined using Spearman's correlation coefficient (r). The mean lumbar Fm in the high SVA group was 67.6%; significantly higher than that in the low SVA group (p = 0.046). There was a negative correlation between cervical Fm with T1 slope (r = -0.589, p = 0.034) and lumbar Fm with lumbar lordosis (r = -0.566, p = 0.035). Lumbar Fm was positively correlated with center of gravity-SVA (r = 0.615, p = 0.029), T1 slope (r = 0.613, p = 0.026), and SVA (r = 0.612, p = 0.020). The results suggested sagittal malalignment increased the load on the thoracolumbar and lower lumbar discs and was associated with cervical disc loading.


Subject(s)
Intervertebral Disc , Lordosis , Adult , Humans , Female , Aged , Standing Position , Lordosis/diagnostic imaging , Intervertebral Disc/diagnostic imaging , Lower Extremity , Neck , Lumbar Vertebrae/diagnostic imaging
16.
J Synchrotron Radiat ; 29(Pt 5): 1265-1272, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-36073886

ABSTRACT

In this study, double-multilayer monochromators that generate intense, high-energy, pink X-ray beams are designed, installed and evaluated at the SPring-8 medium-length (215 m) bending-magnet beamline BL20B2 for imaging applications. Two pairs of W/B4C multilayer mirrors are designed to utilize photon energies of 110 keV and 40 keV with bandwidths of 0.8% and 4.8%, respectively, which are more than 100 times larger when compared with the Si double-crystal monochromator (DCM) with a bandwidth of less than 0.01%. At an experimental hutch located 210 m away from the source, a large and uniform beam of size 14 mm (V) × 300 mm (H) [21 mm (V) × 300 mm (H)] was generated with a high flux density of 1.6 × 109 photons s-1 mm-2 (6.9 × 1010 photons s-1 mm-2) at 110 keV (40 keV), which marked a 300 (190) times increase in the photon flux when compared with a DCM with Si 511 (111) diffraction. The intense pink beams facilitate advanced X-ray imaging for large-sized objects such as fossils, rocks, organs and electronic devices with high speed and high spatial resolution.


Subject(s)
Photons , Synchrotrons , X-Rays
17.
Regen Ther ; 21: 250-257, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36092508

ABSTRACT

Background: Recently, various regenerative therapies have been developed based on induced pluripotent stem (iPS) cells. However, hygienic control strategies have not been established at the manufacturing facilities. We aimed to evaluate the safety and effects of continuous exposure to low-dose chlorine dioxide (ClO2) gas on cell fates, and to determine the optimum dose for safe usage of this disinfectant. Methods: We cultured an iPS cell line in the absence or presence of various doses of ClO2 gas. We evaluated cell proliferation, cell death, the maintenance of undifferentiated state, and cell senescence. Results: We found that iPS cell proliferation was not affected by 0.05 or 0.1 ppmv ClO2 gas in the atmosphere. Although 0.1 ppmv ClO2 slightly affected apoptosis, it was not a significant effect. Moreover, neither at 0.05 nor 0.1 ppmv ClO2 gas significantly affected the characteristics of iPS cells. Discussion and conclusion: Continuous exposure to 0.05 or 0.1 ppmv ClO2 gas did not affect the fate of iPS cells. These results may contribute to the development of new strategies for hygiene control in cell processing facilities.

18.
Medicina (Kaunas) ; 58(8)2022 Aug 05.
Article in English | MEDLINE | ID: mdl-36013524

ABSTRACT

Background and Objectives: Adequate initial fixation of the uncemented acetabular component in total hip arthroplasty is necessary to achieve long-term survival. Although screw fixation contributes to improved cup stability, there is currently no consensus on the use of this method. This study aimed to assess the existing randomized controlled trials (RCTs) on the efficacy and safety of cup fixation in total hip arthroplasty without screws. Materials and Methods: We searched the EMBASE, MEDLINE, Cochrane Central Register of Controlled Trials, World Health Organization International Clinical Trials Registry Platform, and ClinicalTrials.gov databases to identify RCTs published before February 2022. Primary outcomes were reoperation, cup migration, and Harris Hip Score. Secondary outcomes were the presence of a radiolucent line in the acetabular region, translation and rotation movement, and polyethylene wear. We conducted meta-analyses using the random-effects models. The revised Cochrane risk-of-bias tool was used to assess the risk of bias for outcomes of interest; the Grading of Recommendations, Assessment, Development, and Evaluation approach was used to summarize the body of evidence. Results: We included six reports from four studies. Total hip arthroplasty without screw fixation to the acetabular cup had little to no effect on reoperation (pooled relative risk, 0.98; 95% confidence interval, 0.14-6.68; I2 = 0%), cup migration (pooled relative risk, 1.72; 95% confidence interval, 0.29-10.33; I2 = 1%), Harris Hip Score (mean difference, 1.19; 95% confidence interval, -1.31-3.70; I2 = 0%), radiolucent line (pooled relative risk, 5.91; 95% confidence interval, 0.32-109.35), translation and rotation of all axes, and polyethylene wear (mean difference, 0.01; 95% confidence interval, -0.01-0.04; I2 = 0%), with very low certainty of evidence on all measures. Conclusions: The efficacy of acetabular cups without screw fixation in total hip arthroplasty remains uncertain, suggesting the need for prudent clinical application. Further large-scale, well-designed studies with low risk of bias are required.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Acetabulum/surgery , Bone Screws , Follow-Up Studies , Humans , Polyethylenes , Prosthesis Failure , Randomized Controlled Trials as Topic , Reoperation
20.
Cureus ; 14(2): e21997, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35282548

ABSTRACT

Slipped capital femoral epiphysis (SCFE) generally occurs in adolescents but rarely in adults. Rapidly destructive coxopathy (RDC) is characterized by rapid joint destruction, including disruption of the joint at the femoral head and acetabulum as well as reduction of the joint space, within six to 12 months. The mechanism of RDC is likely multifactorial but has not yet been identified. Moreover, there are no reports of displaced femoral head fractures similar to an SCFE associated with RDC. We report a rare case of RDC with femoral head fracture that is similar to SCFE in an 86-year-old woman. Although the exact cause of the femoral head fracture is unknown, it can develop into RDC. Awareness of orthopedic surgeons regarding this condition is crucial for appropriate treatment, by monitoring the presentation of symptoms and imaging/radiographic findings.

SELECTION OF CITATIONS
SEARCH DETAIL
...