Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Synchrotron Radiat ; 25(Pt 4): 1229-1237, 2018 Jul 01.
Article in English | MEDLINE | ID: mdl-29979186

ABSTRACT

Coherent X-ray diffraction imaging (CXDI) is a promising technique for non-destructive structural analysis of micrometre-sized non-crystalline samples at nanometre resolutions. This article describes an atmospheric CXDI system developed at SPring-8 Hyogo beamline BL24XU for in situ structural analysis and designed for experiments at a photon energy of 8 keV. This relatively high X-ray energy enables experiments to be conducted under ambient atmospheric conditions, which is advantageous for the visualization of samples in native states. The illumination condition with pinhole-slit optics is optimized according to wave propagation calculations based on the Fresnel-Kirchhoff diffraction formula so that the sample is irradiated by X-rays with a plane wavefront and high photon flux of ∼1 × 1010 photons/16 µmø(FWHM)/s. This work demonstrates the imaging performance of the atmospheric CXDI system by visualizing internal voids of sub-micrometre-sized colloidal gold particles at a resolution of 29.1 nm. A CXDI experiment with a single macroporous silica particle under controlled humidity was also performed by installing a home-made humidity control device in the system. The in situ observation of changes in diffraction patterns according to humidity variation and reconstruction of projected electron-density maps at 5.2% RH (relative humidity) and 82.6% RH at resolutions of 133 and 217 nm, respectively, were accomplished.

2.
Rev Sci Instrum ; 88(8): 086110, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28863654

ABSTRACT

The intensity distribution in phase space of an X-ray synchrotron radiation beamline was measured using a pinhole camera method, in order to verify astigmatism compensation by a Fresnel zone plate focusing optical system. The beamline is equipped with a silicon double crystal monochromator. The beam size and divergence at an arbitrary distance were estimated. It was found that the virtual source point was largely different between the vertical and horizontal directions, which is probably caused by thermal distortion of the monochromator crystal. The result is consistent with our astigmatism compensation by inclining a Fresnel zone plate.

SELECTION OF CITATIONS
SEARCH DETAIL
...