Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 75(12): 1437-1445, 2019.
Article in Japanese | MEDLINE | ID: mdl-31866642

ABSTRACT

The imaging parameters of non-contrast three-dimensional time-of-flight magnetic resonance angiography (3D TOF-MRA) were optimized to improve the image quality for patients treated using stent-assisted coiling. A simulated blood flow phantom with three types of stents (Enterprise 2, Neuroform Atlas, and LVIS) was imaged by changing echo time (TE), band width (BW), flip angle (FA), and matrix (phase, frequency). The difference between the signal intensity in the simulated vessel and the background was measured at each imaging condition. The ratio of this difference with and without the stent was evaluated as the relative in-stent signal (RIS). In addition, the error ratio of the stent lumen diameter was assessed by comparing the full width at half maximum (FWHM) to that measured by 3D X-ray angiography. The RIS was higher in order of LVIS, Neuroform Atlas, and Enterprise 2 in all conditions. The RIS was higher in imaging conditions with short TE, narrow BW, high FA, and large phase matrix. The highest RIS was seen with a frequency matrix of 320 in the Enterprise 2 and 256 in the others. FWHM error ratio was smaller in the same order as the RIS. FWHM error ratio was smaller in imaging conditions with short TE, large frequency matrix (>384), large phase matrix (>224), and high FA (>20°). Imaging conditions of 3D TOF-MRA that were effective to improve the image quality for stent lumen evaluation were short TE and high spatial resolution.


Subject(s)
Magnetic Resonance Angiography , Drug Delivery Systems , Humans , Imaging, Three-Dimensional , Intracranial Aneurysm , Phantoms, Imaging , Stents
2.
Rev Sci Instrum ; 86(9): 096103, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26429490

ABSTRACT

Tangential beam radiotherapy is routinely used for radiation therapy after breast conserving surgery. A tissue-equivalent bolus placed on the irradiated area shifts the depth of the dose distribution; this bolus provides uniform dose distribution to the breast. The gel bolus made by the BANG-Pro(®) polymer gel and in an oxygen non-transmission pack was applicable as a dosimeter to measure dose distribution in near-surface buildup region. We validated the use of the gel bolus to improve in the whole-breast/chest wall, including the near-surface buildup region.


Subject(s)
Breast Neoplasms/radiotherapy , Polymers/chemistry , Radiometry/instrumentation , Gels , Monte Carlo Method
3.
Magn Reson Med Sci ; 14(1): 51-6, 2015.
Article in English | MEDLINE | ID: mdl-25500777

ABSTRACT

PURPOSE: We measured T1 and T2 values of cerebral postmortem magnetic resonance (PMMR) imaging and compared the data of cadavers with that of living human subjects. MATERIALS AND METHODS: We performed PMMR imaging of the brains of 30 adults (22 men, 8 women; mean age, 58.2 years) whose deaths were for reasons other than brain injury or disease at a mean of 29.4 hours after death. Before imaging, the bodies were kept in cold storage at 4°C (mean rectal temperature, 15.6°C). We measured T1 and T2 values in the brain bilaterally at 5 sites (bilateral caudate nucleus, putamen, thalamus and gray matter and white matter of the frontal lobe) and compared the data of PMMR imaging with that from MR imaging of the corresponding sites in 24 healthy volunteers (9 men, 15 women; mean age, 51.8 years). We also investigated the influence of body temperature on T1 and T2 values. RESULTS: Compared with MR imaging findings in the living subjects, PMMR imaging showed significantly shorter T1 values in the caudate nucleus, putamen, thalamus and gray matter and white matter of the frontal lobe and significantly longer T2 values in the gray matter and white matter of the frontal lobe; T2 values in the caudate nucleus, putamen, and thalamus showed no such differences. T1 values correlated significantly with body temperature in all 5 brain sites measured, but T2 values did not. CONCLUSION: Compared with findings of cerebral MR imaging in living adult subjects, those of PMMR imaging tended to demonstrate shorter T1 values and longer T2 values. We attribute this to increased water content of tissue, reduced pH, and reduced body temperature after death.


Subject(s)
Brain/pathology , Magnetic Resonance Imaging , Postmortem Changes , Adult , Aged , Aged, 80 and over , Autopsy , Body Temperature , Female , Humans , Male , Middle Aged
4.
Magn Reson Med Sci ; 13(2): 67-72, 2014.
Article in English | MEDLINE | ID: mdl-24769635

ABSTRACT

PURPOSE: Signal intensity and image contrast differ between postmortem magnetic resonance (PMMR) images and images acquired from the living body. We sought to achieve sufficient fat suppression with short-tau inversion recovery (STIR) PMMR imaging by optimizing inversion time (TI). MATERIAL AND METHODS: We subjected 37 deceased adult patients to PMMR imaging at 1.5 tesla 8 to 60 hours after confirmation of death and measured T1 values of areas of subcutaneous fat with relaxation time maps. Rectal temperature (RT) measured immediately after PMMR ranged from 6 to 31°C. We used Pearson's correlation coefficient to analyze the relationship between T1 and relaxation time (RT). We compared STIR images from 4 cadavers acquired with a TI commonly used in the living body and another TI calculated from the linear regression of T1 and RT. RESULTS: T1 values of subcutaneous fat ranged from 89.4 to 182.2 ms. There was a strong, positive, and significant correlation between T1 and RT (r = 0.91, P < 0.0001). The regression expression for the relationship was T1 = 2.6*RT + 90 at a field strength of 1.5T. The subcutaneous fat signal was suppressed more effectively with the optimized TI. CONCLUSION: The T1 value of subcutaneous fat in PMMR correlates linearly with body temperature. Using this correlation to determine TI, fat suppression with PMMR STIR imaging can be easily improved.


Subject(s)
Magnetic Resonance Imaging/methods , Postmortem Changes , Subcutaneous Fat/anatomy & histology , Adult , Aged , Aged, 80 and over , Algorithms , Autopsy , Body Temperature , Cadaver , Female , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Time Factors
5.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 69(9): 933-43, 2013 Sep.
Article in Japanese | MEDLINE | ID: mdl-24064697

ABSTRACT

Polymer gels can be used as tissue equivalent dosimeters, and polymer gel dosimetry can be employed without perturbation of the radiation field. In this study, polymer gel dosimetry was used for small circular irradiation fields 10-30 mm in diameter using a radiation planning system. The irradiated gels were compared with planned data for a 50% dose width of 6 Gy dose maximum, and for the dose difference between gels and planned data over an 80% dose maximum area. The present study investigated magnetic resonance imaging (MRI) conditions based on an optimal dose-R2 calibration curve. The average difference between the full width half maximum of the 50% dose width between gels and planned data was 11%. The average dose difference over 80% of the dose was 5.6%. Optimal dose-R2 calibration curves were acquired using images with echo times of 30 and 60 ms. For cases of larger thicknesses and an increasing number of averages, the coefficients of variance of the curves were smaller than under other conditions. Compared to other traditional dosimetric tools, polymer gels have the advantage of providing three-dimensional dosimetric data. An arbitrary profile from the gel's data can be compared with the profile of the planned data. In the future, new gel dosimeters will be needed that demonstrate improved dose evaluation under 1 Gy and stability in high dose areas.


Subject(s)
Polymers , Radiometry/methods , Gels , Magnetic Resonance Imaging , Radiometry/instrumentation , Radiosurgery , Radiotherapy Planning, Computer-Assisted
6.
Article in Japanese | MEDLINE | ID: mdl-23001272

ABSTRACT

The fractional anisotropy (FA) is calculated by using diffusion tensor imaging (DTI) with multiple motion probing gradients (MPG). While FA has become a widely used tool to detect moderate changes in water diffusion in brain tissue, the measured value is sensitive to scan parameters (e.g. MPG-direction, signal to noise ratio, etc.). Therefore, it is paramount to address the reproducibility of DTI measurements among multiple centers. The purpose of this study was to assess the inter-center variability of FA. We studied five healthy volunteers who underwent DTI brain scanning three times at three different centers (I-III), each with a 1.5 T scanner having a different MPG-schema. Then, we compared the FA and eigenvalue from the three centers measured in seven brain regions: splenium of corpus callosum (CCs), genu of corpus callosum (CCg), putamen, posterior limb of internal capsule, cerebral peduncle, optic radiation, and middle cerebellar peduncle. At the CCs and CCg, there was a statistical difference (p<0.05) between center Iand center IIfor the same MPG-directions. Furthermore, at CCs and CCg, there was a statistical difference (p<0.05) between center II and center III for different MPG-directions. Conversely, no statistical differences were found between center I and center III for the different MPG-directions for all regions. These results indicate that the FA value was affected by the MPG-schema as well as by the MPG-directions.


Subject(s)
Anisotropy , Brain , Diffusion Tensor Imaging/methods , Corpus Callosum , Humans , Internal Capsule , Putamen , Reproducibility of Results , Tegmentum Mesencephali
7.
Magn Reson Med Sci ; 9(3): 101-8, 2010.
Article in English | MEDLINE | ID: mdl-20885082

ABSTRACT

In Japan, the medical examiner system is not widespread, the rate of autopsy is low, and many medical institutions therefore perform postmortem imaging using clinical equipment. Postmortem imaging is performed to clarify cause of death, select candidates for autopsy, make a guide map for autopsy, or provide additional information for autopsy. Findings are classified into 3 categories: cause of death and associated changes, changes induced by cardiopulmonary resuscitation, and postmortem changes. Postmortem magnetic resonance imaging shows characteristic changes in signal intensity related to low body temperature after death; they are low temperature images.


Subject(s)
Body Temperature , Magnetic Resonance Imaging , Postmortem Changes , Brain/pathology , Brain Neoplasms/diagnosis , Cadaver , Cause of Death , Cerebrospinal Fluid , Forensic Pathology , Freezing , Humans , Magnetic Resonance Spectroscopy
8.
Jpn J Radiol ; 28(1): 8-14, 2010 Jan.
Article in English | MEDLINE | ID: mdl-20112087

ABSTRACT

PURPOSE: We investigated and identified postmortem changes on magnetic resonance imaging (MRI) of the brain to provide accurate diagnostic guidelines. MATERIALS AND METHODS: Our subjects were 16 deceased patients (mean age 57 years) who underwent postmortem computed tomography (CT), MRI, and autopsy, the latter of which showed no abnormalities in the brain. The subjects underwent CT and MRI 6-73 h after confirmation of death (mean 26 h), after being kept in cold storage at 4 degrees C. Postmortem MRI of the brain was performed using T1-weighted imaging (T1WI), T2WI, fluid attenuated inversion recovery (FLAIR) imaging, and diffusion weighted imaging (DWI) with parameters identical to those used for living persons. RESULTS: In all cases, postmortem CT showed brain edema and swelling. Postmortem MRI showed characteristic common signal intensity (SI) changes, including (1) high SI of the basal ganglia and thalamus on T1WI; (2) suppression of fat SI on T2WI; (3) insufficient SI suppression of cerebrospinal fluid on FLAIR imaging; (4) high SI rims along the cerebral cortices and the ventricular wall on DWI; and (5) an apparent diffusion coefficient decrease to less than half the normal value. CONCLUSION: Postmortem MRI of the brain in all cases showed characteristic common SI changes. Global cerebral ischemia without following reperfusion and low body temperature explain these changes.


Subject(s)
Brain/pathology , Magnetic Resonance Imaging/methods , Postmortem Changes , Signal Processing, Computer-Assisted , Adult , Aged , Aged, 80 and over , Analysis of Variance , Brain/diagnostic imaging , Brain Edema/diagnostic imaging , Brain Edema/pathology , Diffusion Magnetic Resonance Imaging/methods , Female , Humans , Male , Middle Aged , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...