Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Ultrason Imaging ; 44(2-3): 96-104, 2022 05.
Article in English | MEDLINE | ID: mdl-35549598

ABSTRACT

Photoacoustic (PA) technology can be used for non-invasive imaging of blood vessels. In this paper, we report on our prototype PA imaging system with a newly designed ultrasound sensor and its visualization performance of microvascular in animal. We fabricated an experimental system for animals using a high-frequency sensor. The system has two modes: still image mode by wide scanning and moving image mode by small rotation of sensor array. Optical test target, euthanized mice and rats, and live mice were used as objects. The results of optical test target showed that the spatial resolution was about two times higher than that of our conventional prototype. The image performance in vivo was evaluated in euthanized healthy mice and rats, allowing visualization of detailed blood vessels in the liver and kidneys. In tumor-bearing mice, different results of vascular induction were shown depending on the type of tumor and the method of transplantation. By utilizing the video imaging function, we were able to observe the movement of blood vessels around the tumor. We have demonstrated the feasibility of the system as a less invasive animal experimental device, as it can acquire vascular images in animals in a non-contrast and non-invasive manner.


Subject(s)
Neoplasms , Photoacoustic Techniques , Animals , Imaging, Three-Dimensional/methods , Mice , Neoplasms/diagnostic imaging , Photoacoustic Techniques/methods , Rats , Ultrasonography
2.
Ultrasound Med Biol ; 38(2): 287-95, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22178159

ABSTRACT

The most important issue in the assessment of fracture healing is to acquire information about the restoration of the mechanical integrity of bone. Echo tracking (ET) can noninvasively measure the displacement of a certain point on the bone surface under a load. Echo tracking has been used to assess the bone deformation angle of the fracture healing site. Although this method can be used to evaluate bending stiffness, previous studies have not validated the accuracy of bending stiffness. The purpose of the present study is to ensure the accuracy of bending stiffness as measured by ET. A four-point bending test of the gap-healing model in rabbit tibiae was performed to measure bending stiffness. Echo tracking probes were used to measure stiffness, and the results were compared with results of stiffness measurements performed using laser displacement gauges. The relationship between the stiffness measured by these two devices was completely linear, indicating that the ET method could precisely measure bone stiffness.


Subject(s)
Elasticity Imaging Techniques/methods , Fracture Healing/physiology , Image Interpretation, Computer-Assisted/methods , Tibia/diagnostic imaging , Tibia/physiopathology , Tibial Fractures/diagnostic imaging , Tibial Fractures/physiopathology , Algorithms , Animals , Computer Simulation , Elastic Modulus , Image Enhancement/methods , Male , Models, Biological , Osteotomy , Rabbits , Reproducibility of Results , Sensitivity and Specificity , Tensile Strength , Tibia/surgery
3.
Ultrasound Med Biol ; 34(5): 775-83, 2008 May.
Article in English | MEDLINE | ID: mdl-18295968

ABSTRACT

Assessment of bone healing on radiographs depends on the volume and radio-opacity of callus at the healing site, but is not necessarily objective, and there are differences of judgment among observers. To overcome this disadvantage, a clinical system was developed to quantify the stiffness of healing fractures of the tibia in patients by the echo tracking (ET) method in a manner similar to a three-point bending test. The purpose of this study was to ensure that the ET system could clinically assess the progress, delay or arrest of healing. The fibular head and the lateral malleolus were supported. A 7.5-MHz ultrasound probe was placed on the proximal and distal fragments and a load of 25 N was applied. Five tracking points were set along the long axis of the ultrasound probe at intervals of 10 mm. With a multiple ET system, two probes measured the displacement of five tracking points on each of the proximal and distal fragments of the tibia, thereby detecting the bending of the two fragments generated by the load. ET angle was defined as the sum of the inclinations of the proximal and distal fragments. Eight tibial fractures in seven patients treated by a cast or internal fixation were measured over time. In patients with radiographically normal healing, the bending angle decreased exponentially over time. However, in patients with nonunion, the angle remained the same over time. It was demonstrated that the ET method could be clinically applicable to evaluate fracture healing as a versatile, quantitative and noninvasive technique.


Subject(s)
Fracture Healing , Tibia/diagnostic imaging , Tibial Fractures/diagnostic imaging , Adult , Aged , Biomechanical Phenomena , Casts, Surgical , Female , Fracture Fixation, Internal/methods , Humans , Male , Middle Aged , Tibia/physiopathology , Tibial Fractures/physiopathology , Tibial Fractures/therapy , Treatment Outcome , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...