Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
PeerJ Comput Sci ; 9: e1620, 2023.
Article in English | MEDLINE | ID: mdl-37869462

ABSTRACT

Purpose: The purpose of this study is to compare two libraries dedicated to the Markov chain Monte Carlo method: pystan and numpyro. In the comparison, we mainly focused on the agreement of estimated latent parameters and the performance of sampling using the Markov chain Monte Carlo method in Bayesian item response theory (IRT). Materials and methods: Bayesian 1PL-IRT and 2PL-IRT were implemented with pystan and numpyro. Then, the Bayesian 1PL-IRT and 2PL-IRT were applied to two types of medical data obtained from a published article. The same prior distributions of latent parameters were used in both pystan and numpyro. Estimation results of latent parameters of 1PL-IRT and 2PL-IRT were compared between pystan and numpyro. Additionally, the computational cost of the Markov chain Monte Carlo method was compared between the two libraries. To evaluate the computational cost of IRT models, simulation data were generated from the medical data and numpyro. Results: For all the combinations of IRT types (1PL-IRT or 2PL-IRT) and medical data types, the mean and standard deviation of the estimated latent parameters were in good agreement between pystan and numpyro. In most cases, the sampling time using the Markov chain Monte Carlo method was shorter in numpyro than that in pystan. When the large-sized simulation data were used, numpyro with a graphics processing unit was useful for reducing the sampling time. Conclusion: Numpyro and pystan were useful for applying the Bayesian 1PL-IRT and 2PL-IRT. Our results show that the two libraries yielded similar estimation result and that regarding to sampling time, the fastest libraries differed based on the dataset size.

2.
Sci Rep ; 13(1): 17533, 2023 10 16.
Article in English | MEDLINE | ID: mdl-37845348

ABSTRACT

To evaluate the diagnostic performance of our deep learning (DL) model of COVID-19 and investigate whether the diagnostic performance of radiologists was improved by referring to our model. Our datasets contained chest X-rays (CXRs) for the following three categories: normal (NORMAL), non-COVID-19 pneumonia (PNEUMONIA), and COVID-19 pneumonia (COVID). We used two public datasets and private dataset collected from eight hospitals for the development and external validation of our DL model (26,393 CXRs). Eight radiologists performed two reading sessions: one session was performed with reference to CXRs only, and the other was performed with reference to both CXRs and the results of the DL model. The evaluation metrics for the reading session were accuracy, sensitivity, specificity, and area under the curve (AUC). The accuracy of our DL model was 0.733, and that of the eight radiologists without DL was 0.696 ± 0.031. There was a significant difference in AUC between the radiologists with and without DL for COVID versus NORMAL or PNEUMONIA (p = 0.0038). Our DL model alone showed better diagnostic performance than that of most radiologists. In addition, our model significantly improved the diagnostic performance of radiologists for COVID versus NORMAL or PNEUMONIA.


Subject(s)
COVID-19 , Deep Learning , Pneumonia , Humans , COVID-19/diagnostic imaging , COVID-19 Testing , X-Rays , Tomography, X-Ray Computed/methods , Pneumonia/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Radiologists , Computers , Retrospective Studies
3.
Pol J Radiol ; 85: e67-e81, 2020.
Article in English | MEDLINE | ID: mdl-32467740

ABSTRACT

The optic nerve is morphologically classified as a peripheral nerve, but histologically it shares characteristics with the central nerves. Diseases that affect vision and the optic nerve are many and varied: optic neuritis, demyelination (multiple sclerosis, acute disseminated encephalomyelitis, neuromyelitis optica spectrum disorder, and myelin oligodendrocyte glycoprotein antibody-related disorders), drugs, collagen disease, vasculitis, infection, trauma, vascular abnormalities, tumours, and non-tumoural masses. In this review, we summarise the magnetic resonance imaging findings for various pathological conditions that cause deterioration in visual acuity.

SELECTION OF CITATIONS
SEARCH DETAIL
...