Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.407
Filter
1.
Oper Dent ; 49(2): 231-244, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38349845

ABSTRACT

OBJECTIVES: This study aimed to investigate bond performance of various resin luting cement (RLC) systems on enamel and dentin in different etching modes and to compare the RLC-tooth interface morphology using scanning electron microscopy (SEM). METHODS AND MATERIALS: The self-adhesive RLC systems used in combination with universal adhesives were as follows: Scotchbond Universal Adhesive Plus + RelyX Universal (3M Oral Care) and Clearfil Universal Bond Quick ER + SA Luting Multi (Kuraray Noritake Dental). These RLC systems were also used alone as self-adhesive RLC systems without universal adhesives (self-adhesive mode). The conventional RLC systems for comparison materials were as follows: BeautiBond Xtream + ResiCem EX (Shofu) and Tooth Primer + Panavia V5 (Kuraray Noritake Dental). Twelve specimens were prepared for each group to measure shear bond strength (SBS) in different etching modes. A stainless-steel rod was used as a substitute for indirect restorations. Bonded specimens were allocated to baseline (stored for 24 hours) and artificially aged (thermocycling [TC] for 10,000 cycles) groups. Representative treated tooth surfaces and RLC-tooth interfaces were observed using SEM. RESULTS: Three-way analysis of variance (ANOVA) revealed that all the factors (etching mode, storage period, and RLC system) had a significant influence on the enamel SBS values (p<0.05). Enamel SBS was significantly higher in etch-&-rinse (ER) mode than in self-etch (SE) mode, regardless of RLC system or storage period. Three-way ANOVA showed that all the factors had a significant influence on the dentin SBS values (p<0.001). Most RLC systems showed significantly higher dentin SBS in SE mode than in ER mode, regardless of storage period. However, the combination with Scotchbond Universal Adhesive Plus and RelyX Universal showed no significant difference in SBS values between etching modes at the baseline and showed a significantly higher SBS value in ER mode than in SE mode after TC. CONCLUSIONS: The self-adhesive RLC systems with universal adhesives tended to show higher enamel and dentin bond performance than the self-adhesive RLC systems alone. The morphology of treated tooth surfaces and resin cement-tooth interfaces were dependent on the RLC system and etching mode used. The RLC systems with primer application showed a thin, high-density layer above the intact dentin in both etching modes, suggesting chemical interaction.


Subject(s)
Dental Bonding , Resin Cements , Dental Cements/chemistry , Dentin-Bonding Agents/chemistry , Dental Bonding/methods , Dentin , Materials Testing , Shear Strength
2.
Public Health ; 217: 115-124, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36878120

ABSTRACT

OBJECTIVES: The study aimed to evaluate the long-term metabolic risk profiles of Fukushima residents after the Great East Japan Earthquake of March 2011. STUDY DESIGN: This was a cross-sectional and a longitudinal design. METHODS: The Fukushima Health Database (FDB) contains 2,331,319 annual health checkup records of participants aged 40-74 years between 2012 and 2019. We checked the validity of the FDB by comparing the prevalence of metabolic factors with the National Database of Health Insurance Claims and Specific Health Checkups (NDB). We applied a regression analysis to determine the changes and project the trends of metabolic factors over the years. RESULTS: Compared to the NDB, the prevalence of metabolic factors in Fukushima was higher than the country average from 2013 to 2018, and they showed the same trends as those from the FDB. The prevalence of metabolic syndrome (MetS) increased from 18.9% in 2012 to 21.4% in 2019 (an annual increase of 2.74%) in men and from 6.8 to 7.4% (an annual increase of 1.80%) in women in Fukushima. The standardized prevalence of MetS, being overweight, and diabetes is projected to continue increasing, with disparities among subareas being higher in evacuees than in non-evacuees. An annual decrease of 0.38-1.97% in hypertension was mainly observed in women. CONCLUSIONS: The prevalence of metabolic risk is higher in Fukushima as compared to the country average. The increasing metabolic risk in subareas, including the evacuation zone, highlights the need to control MetS in Fukushima residents.


Subject(s)
Diabetes Mellitus , Earthquakes , Fukushima Nuclear Accident , Metabolic Syndrome , Male , Humans , Female , Metabolic Syndrome/epidemiology , Prevalence , Cross-Sectional Studies , Diabetes Mellitus/epidemiology , Japan/epidemiology
3.
Oper Dent ; 46(3): 306-315, 2021 May 01.
Article in English | MEDLINE | ID: mdl-34411249

ABSTRACT

PURPOSE: The present study evaluated the color-matching ability of a structural colored resin composite to compare it with resin composites employing pigments. METHODS AND MATERIALS: A structural colored resin composite (Omnichroma [OMC]), a supranano-filled resin composite (Estelite ∑ Quick [ELQ]), and a nano-filled resin composite (Filtek Supreme Ultra [FSU]) were used. Each resin composite was packed into a Teflon mold and pressed down with a clear strip under a glass slide. The specimens were light irradiated through the slide with a light-emitting diode curing unit. The thickness of the specimens (n=6) was measured with a digital caliper before being transferred to distilled water and stored at 37°C for 24 hours. The measurements of the optical characteristics of the specimens on a black-and-white background were performed using a spectrophotometer. D65 (CIE D65) was used as a light source for the spectrophotometer. Measurements were repeated three times for each specimen under each color-measurement condition, and average values for three same-shade specimens were calculated. One-way analysis of variance and Tukey post hoc tests were used (α=0.05). To determine its ability to match the color of artificial teeth, each shade of resin composite was placed in a cavity before performing color measurements. Using a spectrophotometer (CMS-35F S/C) with a flexible sensor, L*, a*, and b* values were obtained. RESULTS: The spectral reflectance curve of OMC showed that it reflected light wavelengths from 430-700 nm regardless of the background color and thickness of the specimens. The percentage of reflectance of ELQ decreased near wavelengths of 550-580 nm. Regarding the influence of background color on CIE L*, a*, b* values, the L* level showed significantly higher values for all tested materials with white backgrounds, and OMC was most affected by the difference in background color. However, a* values of ELQ and FSU were significantly higher with a black background than with a white background, and OMC showed a significantly higher value with a white background than with a black background. The b* values were higher with a white background than with a black background and were significantly higher for all three products, and these tendencies were much greater for ELQ and FSU. CONCLUSIONS: The ability of OMC to match the color of artificial teeth showed acceptable color compatibility, regardless of the shade of the artificial teeth and the depth of the cavity. However, ELQ and FSU showed reduced color compatibility, especially for a cavity depth of 3.0 mm. Excellent color matching ability was confirmed for the structural colored resin composite OMC, resulting in reduced color differences and therefore improving the esthetic appearance of the restoration, simplifying shade matching, and compensating for any color mismatch.


Subject(s)
Composite Resins , Dental Caries , Color , Humans , Materials Testing , Spectrophotometry , Water
4.
Oper Dent ; 46(3): E117-E131, 2021 May 01.
Article in English | MEDLINE | ID: mdl-34370032

ABSTRACT

OBJECTIVE: The aim of this study was to determine the flexural properties and surface characteristics of a structural colored resin composite after different finishing and polishing methods, in comparison to those of conventional resin composites. METHODS AND MATERIALS: A structural color resin composite, Omnichroma (OM, Tokuyama Corp, Chiyoda City, Tokyo, Japan), and two comparison resin composites, Filtek Supreme Ultra (FS, 3M, St Paul, MN, USA) and Tetric EvoCeram (TE, Ivoclar Vivadent, Schaan, Liechtenstein), were used. The flexural properties of the resin composites were determined in accordance with the ISO 4049 specifications. For surface properties, 70 polymerized specimens of each resin composite were prepared and divided into seven groups of 10. Surface roughness (Sa), gloss (GU), and surface free energy (SFE) were investigated after the following finishing and polishing methods. Three groups of specimens were finished with a superfine-grit diamond bur (SFD), and three with a tungsten carbide bur (TCB). After finishing, one of the two remaining groups was polished with a one-step silicone point (CMP), and the other with an aluminum oxide flexible disk (SSD). A group ground with SiC 320-grit was set as a baseline. RESULTS: The average flexural strength ranged from 116.6 to 142.3 MPa in the following order with significant differences between each value: FS > TE > OM. The average E ranged from 6.8 to 13.2 GPa in the following order with significant differences between each value: FS > TE > OM. The average R ranged from 0.77 to 1.01 MJ/mm3 in the following order: OM > FS > TE. The Sa values of the OM groups polished with CMP and SSD were found to be significantly lower than those of the other resin composites, regardless of the finishing method. The GU values appeared to be dependent on the material and the finishing method used. The OM specimens polished with SSD showed significantly higher GU values than those polished with CMP. Most of the resin composites polished with SSD demonstrated significantly higher γS values compared to the other groups. Extremely strong negative correlations between Sa and GU in the combined data from the three resin composites and each resin composite and between Sa and γS in the OM specimens were observed; GU showed a strong positive correlation with γS in the same material. CONCLUSION: These findings indicate that both flexural and surface properties are material dependent. Furthermore, the different finishing and polishing methods used in this study were observed to affect the Sa, GU, and SFE of the resin composites.


Subject(s)
Dental Polishing , Flexural Strength , Aluminum Oxide , Composite Resins , Materials Testing , Surface Properties
5.
Oper Dent ; 46(5): E185-E198, 2021 Sep 01.
Article in English | MEDLINE | ID: mdl-35486512

ABSTRACT

This study aimed to evaluate the filler contents (FCs), flexural properties, depth of cure (DOC), wear resistance, and handling properties of different low-viscosity bulk-fill resin composites (LVBRCs) and to determine the correlations between the tested parameters. Six LVBRCs, Beautifil-Bulk (BBF), Bulk Base Hard (BBH), Bulk Base Medium (BBM), Filtek Bulk-Fill Flowable Restorative (FBF), G-ænial Bulk Injectable (GBI), and SDR flow+ Bulk-Fill Flowable (SDR) were used. The DOC and flexural property tests were conducted according to the ISO 4049 specifications. The flexural strength, elastic modulus, and resilience were determined in 12 specimens that were obtained from each of the 6 materials. Sliding-impact-wear testing was conducted by evaluating the wear facets of the specimens using a noncontact profilometer and by confocal laser scanning microscopy. The handling properties of the LVBRC was assessed via extrusion force and thread formation measurements. The DOC for the majority of the LVBRCs was approximately 4 mm. Although the FCs and mechanical properties were material dependent, some LVBRCs exhibited excellent flexural properties and wear resistance. The LVBRCs demonstrated a wide range of extrusion force and thread formation. Regarding the correlations between the tested parameters, extremely strong negative and positive correlations were observed for the DOC versus extrusion force, flexural strength versus elastic modulus, maximum depth versus volume loss, and maximum depth versus thread formation. In addition, strong correlations between FCs and DOC, resilience, wear resistance, and extrusion force were observed.


Subject(s)
Flexural Strength , Mechanical Phenomena , Elastic Modulus , Materials Testing , Viscosity
6.
Oper Dent ; 45(6): 655-663, 2020 Nov 01.
Article in English | MEDLINE | ID: mdl-32674133

ABSTRACT

CLINICAL RELEVANCE: The use of layering techniques is still advisable with many bulk-fill resins and should be the default unless a particular resin is known to not need it. SUMMARY: Objective: The purpose of this study was to investigate how layering techniques affect polymerization shrinkage stresses of high-and low-viscosity bulk-fill resins.Method: Six high-viscosity and six low-viscosity bulk-fill resins were evaluated. Aluminum blocks with a mesial-occlusal-distal (MOD) cavity were machined and randomly divided into groups for different filling techniques (bulk-fill vs horizontal layering vs oblique layering) and further subdivided according to type of resin (high- vs low-viscosity). The cuspal deflection resulting from the polymerization of bulk-fill resin bonded to a MOD cavity within an aluminum block was measured with a digimatic micrometer. Scanning electron microscopy analyses of tested resins were also conducted.Results: In the high-viscosity bulk-fill resins, cuspal deflection of the MOD cavity ranged from 11.2 to 18.2 µm with the bulk-filling technique, from 10.7 to 15.5 µm with the horizontal layering technique, and from 10.9 to 15.2 µm with the oblique layering technique. In the low-viscosity bulk-fill resins, cuspal deflection of the material ranged from 9.2 to 19.8 µm with the bulk-filling technique, from 8.2 to 15.7 µm with the horizontal layering technique, and from 8.4 to 16.4 µm with the oblique layering technique.Conclusion: Cuspal deflections for some high-and low-viscosity bulk-fill resins were significantly reduced by using layering techniques, but the resultant improvement of layering techniques was not applicable to all the bulk-fill resins used in this study.


Subject(s)
Composite Resins , Dental Restoration, Permanent , Materials Testing , Polymerization , Viscosity
7.
Oper Dent ; 45(5): 537-546, 2020 Sep 01.
Article in English | MEDLINE | ID: mdl-32216724

ABSTRACT

CLINICAL RELEVANCE: Some bulk-fill flowable resin composites produce less cuspal deflection than a conventional incrementally filled flowable resin composites. SUMMARY: Objective: This study investigated simulated cuspal deflection and flexural properties of bulk-fill and conventional flowable resin composites.Methods and Materials: Five bulk-fill and six conventional flowable resin composites were evaluated. Aluminium blocks with a mesio-occlusal-distal cavity were prepared and randomly divided into groups for each of the different measurement techniques and were further subdivided according to the type of flowable resin composite. The simulated cuspal deflection caused by the polymerization of resin composite within an aluminium block was measured using a highly accurate submicron digimatic micrometer or a confocal laser scanning microscope (CLSM). In addition, the flexural properties of tested resin composites were measured to investigate the relation between cuspal deflection and flexural properties, and the resin composites were observed using scanning electron microscopy.Results: Simulated cuspal deflection of some bulk-fill flowable resin composites was found to be significantly lower than or similar to those for conventional counterparts, regardless of the measurement method. There were statistically significant differences in flexural properties depending on the material, regardless of the type of flowable resin composite. Pearson correlation analysis did not reveal a statistically significant relationship between flexural properties and cuspal deflection.Conclusion: These results indicate that some bulk-fill flowable resin composites exhibit lower cuspal deflection with the bulk-filling technique than is shown by conventional flowable resin composites using the incremental filling technique. Simulated cuspal deflection can be measured using either a micrometer or CLSM, but this experiment failed to show a significant relationship between cuspal deflection and flexural properties of flowable resin composites.


Subject(s)
Composite Resins , Flexural Strength , Materials Testing , Polymerization
8.
Oper Dent ; 45(1): 80-91, 2020.
Article in English | MEDLINE | ID: mdl-31226005

ABSTRACT

OBJECTIVE: The purpose of this study was to evaluate whether different enamel etching methods with reduced etching times would improve the bonding effectiveness of universal adhesives. METHODS AND MATERIALS: Three enamel etching methods, phosphoric acid ester monomer (PPM) etching, phosphoric acid (PPA) etching, and polyalkenoic acid (PLA) etching, and three universal adhesives, G-Premio Bond (GP), Prime&Bond elect (PE), and Scotchbond Universal Adhesive (SU), were evaluated. Initial bond strengths and fatigue strengths of universal adhesives to ground enamel and ground enamel etched for less than one, five, 10, and 15 seconds using different etching methods were determined. The bonded fatigue specimens were loaded using a sine wave at a frequency of 20 Hz for 50,000 cycles or until failure occurred with a staircase method. Atomic force micrograph (AFM) observations along with measurements of surface Ra roughness and modified surface area of enamel with different etching protocols were also conducted. RESULTS: The bond fatigue durability of universal adhesives to enamel with PPA etching from less than one to 15 seconds and PLA etching for 15 seconds was significantly higher than that to ground enamel. The bond fatigue durability to enamel with PPM etching was not increased compared with ground enamel. The surface Ra roughness and surface area obtained with AFM of enamel increased after PPA and PLA etching, and those values were significantly higher than those of ground enamel. Furthermore, surface Ra roughness and surface area with PPA etching were significantly higher than those with PLA etching. However, surface Ra roughness and surface area of enamel with PPM etching were similar to those of ground enamel regardless of etching time. CONCLUSION: PPA etching for less than one to 15 seconds and PLA etching for 15 seconds improve universal adhesive bonding, surface Ra roughness, and surface area of enamel. However, PPM etching is not effective, regardless of etching time, in improving bonds strengths, increasing surface roughness, and increasing surface area.


Subject(s)
Acid Etching, Dental , Dental Bonding , Dental Cements , Dental Enamel , Materials Testing , Phosphoric Acids , Resin Cements , Shear Strength , Surface Properties
9.
Oper Dent ; 45(2): 183-195, 2020.
Article in English | MEDLINE | ID: mdl-31567054

ABSTRACT

We attempted to determine the effect of universal adhesive application time on dentin bond performance in different etching modes based on shear bond strength (SBS) tests and surface free energy (SFE) measurements. The five universal adhesives used were Adhese Universal (AU), Clearfil Universal Bond Quick (CQ), G-Premio Bond (GP), Scotchbond Universal (SU), and Tokuyama Universal Bond (TU). Bovine dentin specimens were divided into four groups of 10 for each adhesive. SBS and SFE were determined after applying the following surface treatments: 1) self-etch (SE) mode with immediate air blowing after adhesive application (IA treatment), 2) SE mode with prolonged application time (PA treatment), 3) etch-and-rinse (ER) mode with IA treatment, and 4) ER mode with PA treatment. Bonded specimens were subjected to SBS testing. The SFE of adhesive-treated dentin surfaces was measured after rinsing with acetone and water. Three-way analysis of variance revealed that dentin SBS values (p<0.001) were significantly influenced by the factors of adhesive type and application duration, but the factor of pre-etching was not significant (p=0.985). The manufacturer's instructions require longer application times for AU and SU, which showed significantly lower SBS values in IA than in PA treatment in both etching modes. However, the difference in the other adhesives was not significant between the IA and PA treatments in either etching mode. The total SFE (γS) was dependent on the adhesive and etching mode. The γS value of the initial group (SiC paper ground group) at baseline was 69.5 (mN·m-1) and that of the pre-etching group at baseline was 30.6 (mN·m-1). For all the adhesives, γS in SE mode showed significantly higher values than in ER mode, regardless of the application time. In SE mode, almost all universal adhesives tested showed lower γS values in PA treatment than in IA treatment. For ER mode, all the adhesives showed significantly higher γS values than those of the pre-etching baseline, regardless of the application time. Most adhesives did not show any significant differences in γS values between IA and PA treatments, regardless of etching mode.


Subject(s)
Dental Bonding , Dentin-Bonding Agents , Acid Etching, Dental , Adhesives , Animals , Cattle , Dental Cements , Dentin , Materials Testing , Resin Cements , Shear Strength
11.
Oper Dent ; 45(2): 196-208, 2020.
Article in English | MEDLINE | ID: mdl-31738692

ABSTRACT

The aim of this study was to determine the effect of aluminablasting on the bond durability of universal adhesives and adherent surface characteristics. Adhese Universal (Ivoclar Vivadent), All-Bond Universal (Bisco), Bondmer Lightless (Tokuyama Dental), G-Premio Bond (GC), and Scotchbond Universal (3M ESPE) were used in self-etch mode. The prepared bovine enamel and dentin specimens were divided into two groups based on whether they received an aluminablasting prior to application of the universal adhesives. The resin composite bonded specimens were stored in distilled water at 37°C for 24 hours, following which the shear bond strength (SBS) of half of the specimens was measured (24-hour group). The other half was subjected to 30,000 thermal cycles between 5 and 55°C before SBS measurement (TC group). Surface roughness (Ra) and surface free energy (SFE) of the adherent surfaces were also measured, and scanning electron microscopy observation and scanning electron microscopy/energy-dispersive X-ray analysis were carried out. Most of the adhesives did not show any significant differences in enamel SBS values between the two pretreatment groups, regardless of the storage condition. However, the dentin SBS values were significantly lower in specimens that underwent aluminablasting compared with those that did not, irrespective of their storage conditions. Significantly higher Ra and SFE values were observed in the enamel and dentin of specimens that underwent aluminablasting. Although aluminablasting increased the Ra and SFE values of enamel and dentin, its effect on the SBS value was dependent on the tooth substrate. In addition to C, O, Na, Mg, P, and Ca, the element Al was detected in the enamel and dentin of samples that had undergone aluminablasting. These results suggest that although aluminablasting of the tooth surface is thought to be effective for modification of the adherent surface, it may not enhance enamel bond performance and may also adversely affect the dentin bond effectiveness of the universal adhesives.


Subject(s)
Dental Bonding , Dentin-Bonding Agents , Acid Etching, Dental , Animals , Cattle , Dental Cements , Materials Testing , Resin Cements , Shear Strength , Surface Properties
12.
Oper Dent ; 45(2): E91-E104, 2020.
Article in English | MEDLINE | ID: mdl-31738697

ABSTRACT

The purpose of this study was to determine the influence of finishing and polishing methods on surface properties of bulk-fill resin composites through surface roughness (Ra) and surface free energy (SFE) measurements, and scanning electron microscopy (SEM) observations. Three bulk-fill resin composites, Tetric EvoCeram Bulk Fill (TB), Filtek Bulk Fill (FB), and Filtek Bulk Fill Flowable Restorative (FF), and two conventional resin composites, Clearfil AP-X (AP) and Estelite ∑ Quick (EQ) were used. Seventy cured specimens of each resin composite were prepared and divided into seven groups of 10 specimens. Ra, SFE measurements, and SEM observations were conducted after finishing and polishing procedures. Three groups of specimens were finished with a fine grit diamond bur (FDB), and three with a tungsten carbide bur (CBB). After finishing, one group from each type of finishing was polished with aluminum oxide flexible disks (SSD) and one group from each type of finishing was polished with diamond particles embedded in a silicone point (CMP). A baseline group of samples that were neither finished nor polished after removing the translucent strips from the surface was examined. Although the baseline group showed significantly lower Ra values than the other groups, most resin composites showed lower Ra values with CBB+SSD than with the other finishing and polishing groups. Among the tested resin composites, EQ showed significantly lower Ra values than the other resin composites, regardless of the finishing and polishing methods. On the other hand, AP showed significantly higher Ra values than the other resin composites in all finishing and polishing groups, apart from FB with FDB. For the finished specimens, most resin composites showed higher SFE values with CBB than with FDB. For the polished specimens, all the tested resin composites with CMP showed lower γS values than those with SSD, regardless of the finishing method. The baseline groups of TB and FB showed significantly lower SFE values than the other finished and polished groups. In the SEM observations, all the examined resin composites showed rougher surfaces after finishing with FDB than with CBB. However, when comparing the different polishing methods (CMP and SSD), surface smoothness appeared to be material dependent.


Subject(s)
Dental Polishing , Dental Restoration, Permanent , Aluminum Oxide , Composite Resins , Diamond , Materials Testing , Microscopy, Electron, Scanning , Surface Properties
13.
BMC Cancer ; 19(1): 912, 2019 Sep 12.
Article in English | MEDLINE | ID: mdl-31510956

ABSTRACT

BACKGROUND: Interaction between cancer cells and fibroblasts mediated by extracellular matrix metalloproteinase inducer (emmprin, CD147) is important in the invasion and proliferation of cancer cells. However, the exact mechanism of emmprin mediated stimulation of matrix metalloprotease-2 (MMP-2) production from fibroblasts has not been elucidated. Our previous studies using an inhibitory peptide against emmprin suggested the presence of a molecule on the cell membrane which forms a complex with emmprin. Here we show that CD73 expressed on fibroblasts interacts with emmprin and is a required factor for MMP-2 production in co-cultures of sarcoma cells with fibroblasts. METHODS: CD73 along with CD99 was identified by mass spectrometry analysis as an emmprin interacting molecule from a co-culture of cancer cells (epithelioid sarcoma cell line FU-EPS-1) and fibroblasts (immortalized fibroblasts cell line ST353i). MMP-2 production was measured by immunoblot and ELISA. The formation of complexes of CD73 with emmprin was confirmed by immunoprecipitation, and their co-localization in tumor cells and fibroblasts was shown by fluorescent immunostaining and proximity ligation assays. RESULTS: Stimulated MMP-2 production in co-culture of cancer cells and fibroblasts was completely suppressed by siRNA knockdown of CD73, but not by CD99 knockdown. MMP-2 production was not suppressed by CD73-specific enzyme inhibitor (APCP). However, MMP-2 production was decreased by CD73 neutralizing antibodies, suggesting that CD73-mediated suppression of MMP-2 production is non-enzymatic. In human epithelioid sarcoma tissues, emmprin was immunohistochemically detected to be mainly expressed in tumor cells, and CD73 was expressed in fibroblasts and tumor cells: emmprin and CD73 were co-localized predominantly on tumor cells. CONCLUSION: This study provides a novel insight into the role of CD73 in emmprin-mediated regulation of MMP-2 production.


Subject(s)
5'-Nucleotidase/metabolism , Basigin/metabolism , Matrix Metalloproteinase 2/metabolism , Biomarkers , Cell Line, Tumor , Coculture Techniques , Fibroblasts , GPI-Linked Proteins/metabolism , Humans , Immunohistochemistry , Mass Spectrometry , Models, Biological , Proteomics/methods
14.
Clin Radiol ; 74(10): 805-812, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31320111

ABSTRACT

AIM: To evaluate the effect of the saline flush (SF) technique on the depiction of lesions and the reduction of perivenous artefacts in the head and neck region using dual-energy computed tomography (CT) with virtual monochromatic imaging (VMI). MATERIALS AND METHODS: Fifty patients with head and neck cancer were divided into two groups: group A, without a SF and group B, with a 30-ml SF. All images were acquired using fast kilovolt-switching CT (Revolution HD, GE Healthcare, Milwaukee, WI, USA). Contrast-to-noise ratios (CNRs) of the lesions were calculated at VMI energy levels ranging from 40 to 80 keV. Subjective analysis of overall image quality, delineation of lesions, and perivenous artefacts was conducted by two reviewers at both VMI energy level 40 keV and the optimal energy level (which showed optimal CNR by objective analysis). RESULTS: Optimal energy level was 63 keV for group A and 61 keV for group B. At VMI energy levels ranging from 40 to 80 keV, the CNR was higher for group B. The highest subjective overall image quality was shown for group B at the optimal energy level (subjective image quality mean value, 3.40). Subjective delineation of lesions was comparable. The perivenous artefact score was significantly higher for group B (2.44 versus 2.74 [p<0.05] at 40 keV, 3.20 versus 3.46 [p<0.05] at the optimal energy level). CONCLUSION: The SF technique results in an improvement of lesion CNR and a reduction of perivenous artefacts in VMI using duel-energy CT, especially at 40 keV.


Subject(s)
Carcinoma, Squamous Cell/diagnostic imaging , Head and Neck Neoplasms/diagnostic imaging , Image Enhancement/methods , Sodium Chloride/administration & dosage , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Artifacts , Contrast Media , Female , Humans , Iopamidol , Male , Middle Aged , Retrospective Studies , Triiodobenzoic Acids
15.
Lupus ; 28(9): 1062-1073, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31296139

ABSTRACT

OBJECTIVE: The objective of this study was to investigate possible differences in treatment responses between two categories for the onset of lupus nephritis. METHODS: We performed a multicentre, retrospective cohort study of class III-V lupus nephritis patients diagnosed between 1997 and 2014. The renal responses to initial induction therapy were compared between patients who developed lupus nephritis within one year from diagnosis of systemic lupus erythematosus (early (E-) LN) and the remainder (delayed (D-) LN) using the Kaplan-Meier method. We determined the predictors of renal response as well as renal flares and long-term renal outcomes using multivariate Cox regression analyses. RESULTS: A total of 107 E-LN and 70 D-LN patients were followed up for a median of 10.2 years. Log-rank tests showed a lower cumulative incidence of complete response in D-LN compared with E-LN patients. Multivariate analysis identified D-LN (hazard ratio (HR) 0.48, 95% confidence interval (CI) 0.33-0.70), nephrotic syndrome at baseline, and a chronicity index greater than 2 as negative predictors of complete response. D-LN patients were more likely to experience renal flares. D-LN (HR 2.54, 95% CI 1.10-5.83) and decreased renal function were significant predictors of chronic kidney disease at baseline. CONCLUSION: D-LN was a predictor of poorer treatment outcomes, in addition to renal histology and severity of nephritis at lupus nephritis onset.


Subject(s)
Immunosuppressive Agents/therapeutic use , Lupus Erythematosus, Systemic/drug therapy , Lupus Nephritis/drug therapy , Adolescent , Adult , Cohort Studies , Female , Humans , Japan , Lupus Erythematosus, Systemic/complications , Lupus Nephritis/physiopathology , Male , Middle Aged , Retrospective Studies , Time Factors , Treatment Outcome , Young Adult
16.
Oper Dent ; 44(1): 42-53, 2019.
Article in English | MEDLINE | ID: mdl-29856702

ABSTRACT

OBJECTIVE:: The purpose of this study was to evaluate the effect of reduced application times of universal adhesives on enamel bond fatigue and surface morphology of the treated enamel with constant force atomic force microscopy (AFM). METHODS:: Four universal adhesives-Adhese Universal (AU), Clearfil Universal Bond Quick (CU), G-Premio Bond (GP), and Scotchbond Universal Adhesive (SU)-were evaluated in a laboratory for their ability to adhesively bond resin composite to enamel. Shear bond strengths were initially determined using 15 specimens per test group for each adhesive. Shear fatigue strengths were then determined using 20 specimens per test group for each the adhesives. The fatigue specimens were loaded using a sine wave at a frequency of 20 Hz for 50,000 cycles or until failure occurred. AFM observations, surface Ra roughness measurements, and geometric surface area evaluations of enamel surface treated with the adhesive agents were also conducted. RESULTS:: A strong relationship was found between the initial shear bond strength and shear fatigue strength for enamel surface Ra roughness but not for geometric surface area. The initial shear bond strength and shear fatigue strength of CU and GP were not influenced by different application times, unlike those of AU and SU. While the surface area of enamel treated with the adhesive agents was not significantly influenced by different application times and type of adhesive, surface Ra roughness of the enamel in the AU and SU groups significantly increased with increasing application time, unlike CU and GP. CONCLUSIONS:: The results of this study suggest that universal adhesives, used with reduced application times, have adequate Ra surface roughness to provide sufficient resistance to enamel bond fatigue at application times from <1 second to 20 seconds, while the geometric surface area of adhesive-treated enamel did not show any significant changes at these different application times.


Subject(s)
Dental Bonding/methods , Dentin-Bonding Agents/chemistry , Resin Cements/chemistry , Acrylic Resins , Materials Testing , Methacrylates , Microscopy, Atomic Force , Surface Properties , Time Factors
17.
Hernia ; 23(2): 317-322, 2019 04.
Article in English | MEDLINE | ID: mdl-30327983

ABSTRACT

PURPOSE: The purpose of this study was to identify any potential correlation between postoperative mortality and bowel resection in patients with obturator hernias. METHODS: In total, 21 patients who underwent emergency surgery for a primary incarcerated obturator hernia during a 9-year period were retrospectively assessed regarding the correlation between postoperative mortality within 30 days from surgery and bowel resection. RESULTS: The 21 hernias occurred in 20 women and 1 man. The mean age at presentation was 83.3 years. Eight hernias required bowel resection, and operations using mesh were performed for eight hernias. Complications occurred in association with nine hernias, and three patients died. Postoperative mortality was correlated with complications (p = 0.016) and bowel resection (p = 0.010). Patients undergoing bowel resection had a significantly longer operation time (p = 0.009) and a higher rate of postoperative complications (p = 0.018). The systolic blood pressure, pH, and base excess were significantly lower in patients who did than did not undergo bowel resection (p = 0.017, 0.009, and 0.015, respectively). CONCLUSION: As the aging population continues to expand, the number of patients with obturator hernias is speculated to increase. Elderly people with comorbidities require immediate operative procedures because their general condition tends to be exacerbated by bowel obstruction. Postoperative management may be carefully performed in patients with bowel resection because the postoperative mortality rates may be higher in these patients.


Subject(s)
Digestive System Surgical Procedures/mortality , Hernia, Obturator/mortality , Intestines/surgery , Abdominal Wall/surgery , Aged , Aged, 80 and over , Female , Hernia, Obturator/complications , Hernia, Obturator/surgery , Humans , Intestinal Obstruction/etiology , Japan/epidemiology , Male , Operative Time , Postoperative Complications/etiology , Postoperative Period , Retrospective Studies , Risk Factors , Surgical Mesh
18.
Oper Dent ; 44(2): 188-199, 2019.
Article in English | MEDLINE | ID: mdl-30106329

ABSTRACT

The purpose of this study was to determine the effect of different adhesive application methods and etching modes on the dentin bond durability of universal adhesives under thermal cycling (TC). All-Bond Universal (Bisco), Adhese Universal (Ivoclar Vivadent), and Scotchbond Universal (3M ESPE) were used as adhesives. In total, 600 bovine teeth with exposed dentin were divided into 12 groups according to the type of adhesive and subjected to the following bonding procedures: 1) etch-and-rinse mode with active application; 2) etch-and-rinse mode with inactive application; 3) self-etch mode with active application; and 4) self-etch mode with inactive application. Bonded specimens were stored in distilled water at 37°C for 24 hours and then subjected to 5000, 10,000, 30,000, or 50,000 TC between 5°C and 55°C before shear bond strength (SBS) testing, creating a division into a total of five different storage conditions. Baseline specimens were stored in distilled water at 37°C for 24 hours. The SBS test was performed at a cross-head speed of 1.0 mm/min. Three-way analysis of variance revealed that all the factors of application mode, adhesive, and thermal cycle period significantly influenced the SBS values ( p<0.001), regardless of the etching mode. In the baseline groups, all of the tested adhesives with active application had higher SBS values than those with inactive application, regardless of etching mode. In the TC groups, significantly lower SBS values were observed at 50,000 TC with inactive application compared to those with active application, regardless of the etching mode. From the scanning electron microscopy observation of demineralized and deproteinized resin/dentin interfaces, dense resin tags longer than 50 µm were observed in the etch-and-rinse with active application group. On the other hand, the resin tags in self-etch mode were sparse, thin, and much shorter than those in etch-and-rinse mode. Comparing the penetration status of the resin tags with active and inactive application in self-etch mode, the resin tag penetration with inactive application was much lower than that with active application. Active application is effective in enhancing the dentin bond durability of universal adhesives. When using universal adhesives with different etching modes, practitioners should select the optimal etching mode and appropriate application method in accordance with the cavity conditions.


Subject(s)
Dental Bonding , Dentin-Bonding Agents , Acid Etching, Dental , Animals , Cattle , Dental Cements , Dentin , Materials Testing , Resin Cements
19.
Int J Infect Dis ; 77: 34-39, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30292892

ABSTRACT

OBJECTIVE: The objective of this study was to evaluate the effects of earlier intervention by an antimicrobial stewardship team (AST) on antimicrobial use, antimicrobial resistance rates, and the clinical outcomes, without changing the weekly intervention schedule. METHODS: A retrospective study was conducted at Fukuoka University Hospital between April 2013 and March 2016. The effects were compared among three study periods (SP): SP1 (patients receiving anti-methicillin-resistant Staphylococcus aureus agents and carbapenems for ≥14 days), SP2 (patients receiving specific antimicrobials for ≥14 days), and SP3 (patients receiving specific antimicrobials regardless of the duration of treatment). RESULTS: The timing of AST intervention was shortened from an average of 15.5days after administration in SP1 to 4.2 days in SP3. The antimicrobial use density (AUD) of carbapenems and piperacillin-tazobactam decreased significantly (SP2 vs. SP3, p<0.05), and the costs of specific antimicrobials decreased (SP1, US$ 1080000; SP2, US$ 944000; SP3, US$ 763000). The rates of carbapenem resistance among Pseudomonas aeruginosa isolates showed a significant reduction from 16.2% in SP2 to 8.7% in SP3 (p<0.05). The mortality rate and length of stay did not change during the study period. CONCLUSIONS: Earlier intervention by an AST could contribute to the proper use of antimicrobials without adversely affecting patient outcomes.


Subject(s)
Anti-Infective Agents/therapeutic use , Antimicrobial Stewardship , Anti-Infective Agents/economics , Carbapenems/economics , Carbapenems/therapeutic use , Daptomycin/therapeutic use , Drug Resistance, Microbial , Fluoroquinolones/therapeutic use , Humans , Linezolid/therapeutic use , Methicillin-Resistant Staphylococcus aureus/drug effects , Piperacillin, Tazobactam Drug Combination/economics , Piperacillin, Tazobactam Drug Combination/therapeutic use , Pseudomonas aeruginosa/drug effects , Retrospective Studies , Teicoplanin/therapeutic use , Time Factors , Treatment Outcome , Vancomycin/therapeutic use
20.
Sci Rep ; 8(1): 11163, 2018 07 24.
Article in English | MEDLINE | ID: mdl-30042515

ABSTRACT

Benthic community succession patterns at whale falls have been previously established by means of punctual submersible and ROV observations. The contribution of faunal activity rhythms in response to internal tides and photoperiod cues to that community succession dynamism has never been evaluated. Here, we present results from a high-frequency monitoring experiment of an implanted sperm whale carcass in the continental slope (500 m depth) offshore Sagami Bay, Japan. The benthic community succession was monitored at a high frequency in a prolonged fashion (i.e. 2-h intervals for 2.5 months) with a seafloor lander equipped with a time-lapse video camera and an acoustic Doppler profiler to concomitantly study current flow dynamics. We reported here for the first time, to the best of our knowledge, the occurrence of strong 24-h day-night driven behavioral rhythms of the most abundant species (Simenchelys parasitica; Macrocheira kaempferi, and Pterothrissus gissu). Those rhythms were detected in detriment of tidally-controlled ones. Evidence of a diel temporal niche portioning between scavengers and predators avoiding co-occurrence at the carcass, is also provided. The high-frequency photographic and oceanographic data acquisition also helped to precisely discriminate the transition timing between the successional stages previously described for whale falls' attendant communities.


Subject(s)
Body Remains , Ecological Parameter Monitoring/methods , Food Chain , Periodicity , Sperm Whale , Tidal Waves , Acoustics/instrumentation , Analysis of Variance , Animals , Bays , Body Weight , Brachyura/physiology , Eels/physiology , Japan , Male , Multivariate Analysis , Predatory Behavior , Sharks/physiology , Video Recording
SELECTION OF CITATIONS
SEARCH DETAIL
...