1.
Opt Lett ; 30(11): 1399-401, 2005 Jun 01.
Article in English | MEDLINE | ID: mdl-15981546

ABSTRACT

We tried a method of making a 10-km-class large-radius-of-curvature surface that would satisfy both low microroughness (0.1 nm rms) and low waviness (lambda/100) by forming a spherically curved film with a low-loss coating technique on a flat surface produced by mechanical (chemical) polishing. We obtained a SiO2 surface with a 10255 +/- 250-m radius of spherical curvature that had less than lambda/30 waviness and 0.4-nm micro-roughness over a 9-cm-diameter area.

2.
Phys Rev Lett ; 86(18): 3950-4, 2001 Apr 30.
Article in English | MEDLINE | ID: mdl-11328068

ABSTRACT

TAMA300, an interferometric gravitational-wave detector with 300-m baseline length, has been developed and operated with sufficient sensitivity to detect gravitational-wave events within our galaxy and sufficient stability for observations; the interferometer was operated for over 10 hours stably and continuously. With a strain-equivalent noise level of h approximately 5x10(-21)/sqrt[Hz], a signal-to-noise ratio of 30 is expected for gravitational waves generated by a coalescence of 1.4M-1.4M binary neutron stars at 10 kpc distance. We evaluated the stability of the detector sensitivity with a 2-week data-taking run, collecting 160 hours of data to be analyzed in the search for gravitational waves.


Subject(s)
Astronomy/methods , Gravitation , Astronomy/instrumentation , Lasers , Sensitivity and Specificity
3.
Appl Opt ; 39(25): 4616-20, 2000 Sep 01.
Article in English | MEDLINE | ID: mdl-18350051

ABSTRACT

Power recycling was implemented on a fully suspended prototype interferometer with arm lengths of 20 m. A wave-front-sensing technique for alignment control of the suspended mirrors was also implemented, which allowed for several hours of stable operation. A power-recycling gain of greater than 12 was achieved, a significant increase over the highest gain in a suspended mirror Fabry-Perot Michelson interferometer reported to date.

4.
Appl Opt ; 38(13): 2848-56, 1999 May 01.
Article in English | MEDLINE | ID: mdl-18319865

ABSTRACT

A new method has been demonstrated for absolute-length measurements of a long-baseline Fabry-Perot cavity by use of phase-modulated light. This method is based on determination of a free spectral range (FSR) of the cavity from the frequency difference between a carrier and phase-modulation sidebands, both of which resonate in the cavity. Sensitive response of the Fabry-Perot cavity near resonant frequencies ensures accurate determination of the FSR and thus of the absolute length of the cavity. This method was applied to a 300-m Fabry-Perot cavity of the TAMA gravitational wave detector that is being developed at the National Astronomical Observatory, Tokyo. With a modulation frequency of approximately 12 MHz, we successfully determined the absolute cavity length with resolution of 1 microm (3 x 10(-9) in strain) and observed local ground strain variations of 6 x 10(-8).

5.
Appl Opt ; 38(13): 2880-5, 1999 May 01.
Article in English | MEDLINE | ID: mdl-18319869

ABSTRACT

Low-loss mirrors fabricated by ion-beam-sputtering machines for possible application in an interferometric gravitational wave antenna were evaluated by use of Nd:YAG laser light (lambda = 1064 nm) with two distinct measurements: a tabletop experiment that used a short cavity with a small beam with a beam waist of approximately 2w(0) = 0.82 mm, and an optical test that used a 20-m prototypical gravitational-wave detector with a large beam with a beam waist of approximately 2w(0) = 4.4 mm. A multilayer coating comprised 29 layers of SiO(2)/Ta(2)O(5) and one protective coating of SiO(2). The best values obtained as a result of these measurements were 16 ppm (parts in 10(6)) and 30 ppm in total loss, respectively. Also, a two-dimensional loss map generated by use of a small beam successfully revealed the existence of a loss structure within the coating surface. These results imply that a high-reflectance multilayer coating has some inhomogeneities and a loss distribution with a typical scale of a few millimeters and that the total measured losses depend on the beam spot size.