1.
J Breath Res ; 18(3)2024 05 07.
Article in English | MEDLINE | ID: mdl-38663377

ABSTRACT

In the breath research community's search for volatile organic compounds that can act as non-invasive biomarkers for various diseases, hundreds of endogenous volatiles have been discovered. Whilst these systemic chemicals result from normal and abnormal metabolic activities or pathological disorders, to date very few are of any use for the development of clinical breath tests that could be used for disease diagnosis or to monitor therapeutic treatments. The reasons for this lack of application are manifold and complex, and these complications either limit or ultimately inhibit the analytical application of endogenous volatiles for use in the medical sciences. One such complication is a lack of knowledge on the biological origins of the endogenous volatiles. A major exception to this is isoprene. Since 1984, i.e. for 40 years, it has been generally accepted that the pathway to the production of human isoprene, and hence the origin of isoprene in exhaled breath, is through cholesterol biosynthesis via the mevalonate (MVA) pathway within the liver. However, various studies between 2001 and 2012 provide compelling evidence that human isoprene is produced in skeletal muscle tissue. A recent multi-omic investigation of genes and metabolites has revealed that this proposal is correct by showing that human isoprene predominantly results from muscular lipolytic cholesterol metabolism. Despite the overwhelming proof for a muscular pathway to isoprene production in the human body, breath research papers still reference the hepatic MVA pathway. The major aim of this perspective is to review the evidence that leads to a correct interpretation for the origins of human isoprene, so that the major pathway to human isoprene production is understood and appropriately disseminated. This is important, because an accurate attribution to the endogenous origins of isoprene is needed if exhaled isoprene levels are to be correctly interpreted and for assessing isoprene as a clinical biomarker.


Subject(s)
Breath Tests , Butadienes , Hemiterpenes , Pentanes , Humans , Hemiterpenes/analysis , Butadienes/analysis , Pentanes/analysis , Breath Tests/methods , Exhalation , Mevalonic Acid/metabolism , Cholesterol/metabolism , Cholesterol/analysis , Volatile Organic Compounds/analysis , Volatile Organic Compounds/metabolism
2.
J Breath Res ; 17(3)2023 04 19.
Article in English | MEDLINE | ID: mdl-37001512

ABSTRACT

We summarize the history and review the literature on isoprene in exhaled breath and discuss the current evidence and models that describe its endogenous origin and consequence for understanding isoprene levels and their variations in exhaled breath.


Subject(s)
Breath Tests , Butadienes , Humans , Hemiterpenes , Exhalation , Pentanes
4.
J Breath Res ; 6(3): 036008, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22932429

ABSTRACT

Non-invasive disease monitoring on the basis of volatile breath markers is a very attractive but challenging task. Several hundreds of compounds have been detected in exhaled air using modern analytical techniques (e.g. proton-transfer reaction mass spectrometry, gas chromatography-mass spectrometry) and have even been linked to various diseases. However,the biochemical background for most of compounds detected in breath samples has not been elucidated; therefore, the obtained results should be interpreted with care to avoid false correlations. The major aim of this study was to assess the effects of smoking on the composition of exhaled breath. Additionally, the potential origin of breath volatile organic compounds (VOCs) is discussed focusing on diet, environmental exposure and biological pathways based on other's studies. Profiles of VOCs detected in exhaled breath and inspired air samples of 115 subjects with addition of urine headspace derived from 50 volunteers are presented. Samples were analyzed with GC-MS after preconcentration on multibed sorption tubes in case of breath samples and solid phase micro-extraction (SPME) in the case of urine samples. Altogether 266 compounds were found in exhaled breath of at least 10% of the volunteers. From these, 162 compounds were identified by spectral library match and retention time (based on reference standards). It is shown that the composition of exhaled breath is considerably influenced by exposure to pollution and indoor-air contaminants and particularly by smoking. More than 80 organic compounds were found to be significantly related to smoking, the largest group comprising unsaturated hydrocarbons (29 dienes, 27 alkenes and 3 alkynes). On the basis of the presented results, we suggest that for the future understanding of breath data it will be necessary to carefully investigate the potential biological origin of volatiles, e.g., by means of analysis of tissues, isolated cell lines or other body fluids. In particular, VOCs linked to smoking habit or being the results of human exposure should be considered with care for clinical diagnosis since small changes in their concentration profiles(typically in the ppt(v)­ppb(v) range) revealing that the outbreak of certain disease might be hampered by already high background.


Subject(s)
Air Pollutants , Exhalation/physiology , Smoking/physiopathology , Volatile Organic Compounds/analysis , Adult , Aged , Aged, 80 and over , Breath Tests , Creatinine/urine , Female , Humans , Male , Middle Aged , Volatile Organic Compounds/urine
5.
Biochem Biophys Res Commun ; 423(3): 526-30, 2012 Jul 06.
Article in English | MEDLINE | ID: mdl-22683640

ABSTRACT

Breath isoprene accounts for most of the hydrocarbon removal via exhalation and is thought to serve as a non-invasive indicator for assaying several metabolic effects in the human body. The primary objective of this paper is to introduce a novel working hypothesis with respect to the endogenous source of this compound in humans: the idea that muscle tissue acts as an extrahepatic production site of substantial amounts of isoprene. This new perspective has its roots in quantitative modeling studies of breath isoprene dynamics under exercise conditions and is further investigated here by presenting pilot data from a small cohort of late stage Duchenne muscle dystrophy patients (median age 21, 4 male, 1 female). For these prototypic test subjects isoprene concentrations in end-tidal breath and peripheral venous blood range between 0.09-0.47 and 0.11-0.72 nmol/l, respectively, amounting to a reduction by a factor of 8 and more as compared to established nominal levels in normal healthy adults. While it remains unclear whether isoprene can be ascribed a direct physiological mechanism of action, some indications are given as to why isoprene production might have evolved in muscle.


Subject(s)
Hemiterpenes/biosynthesis , Muscular Dystrophy, Duchenne/physiopathology , Respiration , Adolescent , Body Temperature , Butadienes , Cohort Studies , Female , Humans , Male , Muscular Dystrophy, Duchenne/metabolism , Oxidative Stress , Pentanes , Young Adult
6.
J Breath Res ; 6(1): 016005, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22233667

ABSTRACT

Isothermal rebreathing has been proposed as an experimental technique for estimating the alveolar levels of hydrophilic volatile organic compounds (VOCs) in exhaled breath. Using the prototypic test compounds acetone and methanol, we demonstrate that the end-tidal breath profiles of such substances during isothermal rebreathing show a characteristic increase that contradicts the conventional pulmonary inert gas elimination theory due to Farhi. On the other hand, these profiles can reliably be captured by virtue of a previously developed mathematical model for the general exhalation kinetics of highly soluble, blood-borne VOCs, which explicitly takes into account airway gas exchange as a major determinant of the observable breath output. This model allows for a mechanistic analysis of various rebreathing protocols suggested in the literature. In particular, it predicts that the end-exhaled levels of acetone and methanol measured during free tidal breathing will underestimate the underlying alveolar concentration by a factor of up to 1.5. Moreover, it clarifies the discrepancies between in vitro and in vivo blood-breath ratios of hydrophilic VOCs and yields further quantitative insights into the physiological components of isothermal rebreathing and highly soluble gas exchange in general.


Subject(s)
Acetone/analysis , Breath Tests/methods , Lung/chemistry , Methanol/analysis , Pulmonary Gas Exchange , Volatile Organic Compounds/analysis , Adult , Exhalation , Humans , Male , Middle Aged , Respiration , Spirometry
7.
J Breath Res ; 5(3): 037102, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21654024

ABSTRACT

Isoprene is one of the most abundant endogenous volatile organic compounds (VOCs) contained in human breath and is considered to be a potentially useful biomarker for diagnostic and monitoring purposes. However, neither the exact biochemical origin of isoprene nor its physiological role is understood in sufficient depth, thus hindering the validation of breath isoprene tests in clinical routine. Exhaled isoprene concentrations are reported to change under different clinical and physiological conditions, especially in response to enhanced cardiovascular and respiratory activity. Investigating isoprene exhalation kinetics under dynamical exercise helps to gather the relevant experimental information for understanding the gas exchange phenomena associated with this important VOC. The first model for isoprene in exhaled breath has been developed by our research group. In this paper, we aim at giving a concise overview of this model and describe its role in providing supportive evidence for a peripheral (extrahepatic) source of isoprene. In this sense, the results presented here may enable a new perspective on the biochemical processes governing isoprene formation in the human body.


Subject(s)
Breath Tests/methods , Butadienes/pharmacokinetics , Hemiterpenes/pharmacokinetics , Models, Theoretical , Pentanes/pharmacokinetics , Pulmonary Gas Exchange/physiology , Exhalation , Humans
8.
Physiol Meas ; 31(9): 1169-84, 2010 Sep.
Article in English | MEDLINE | ID: mdl-20664160

ABSTRACT

In this phenomenological study we focus on dynamic measurements of volatile organic compounds (VOCs) in exhaled breath under exercise conditions. An experimental setup efficiently combining breath-by-breath analyses using proton transfer reaction mass spectrometry (PTR-MS) with data reflecting the behaviour of major hemodynamic and respiratory parameters is presented. Furthermore, a methodology for complementing continuous VOC profiles obtained by PTR-MS with simultaneous SPME/GC-MS measurements is outlined. These investigations aim at evaluating the impact of breathing patterns, cardiac output or blood pressure on the observed breath concentration and allow for the detection and identification of several VOCs revealing characteristic rest-to-work transitions in response to variations in ventilation or perfusion. Examples of such compounds include isoprene, methyl acetate, butane, DMS and 2-pentanone. In particular, both isoprene and methyl acetate exhibit a drastic rise in concentration shortly after the onset of exercise, usually by a factor of about 3-5 within approximately 1 min of pedalling. These specific VOCs might also be interpreted as potentially sensitive indicators for fluctuations of blood or respiratory flow and can therefore be viewed as candidate compounds for future assessments of hemodynamics, pulmonary function and gas exchange patterns via observed VOC behaviour.


Subject(s)
Breath Tests/methods , Exhalation , Gas Chromatography-Mass Spectrometry/methods , Organic Chemicals/analysis , Organic Chemicals/chemistry , Protons , Acetone/analysis , Acetone/chemistry , Acetone/isolation & purification , Adult , Butadienes/analysis , Butadienes/chemistry , Butadienes/isolation & purification , Female , Hemiterpenes/analysis , Hemiterpenes/chemistry , Hemiterpenes/isolation & purification , Humans , Kinetics , Male , Noble Gases/metabolism , Organic Chemicals/isolation & purification , Pentanes/analysis , Pentanes/chemistry , Pentanes/isolation & purification , Solid Phase Microextraction , Ventilation-Perfusion Ratio , Volatilization , Young Adult
9.
J Breath Res ; 3(1): 016004, 2009 Mar.
Article in English | MEDLINE | ID: mdl-21383452

ABSTRACT

Breath gas samples from 27 patients with epilepsy (17 male and 10 female patients; mean age: 9.7 years, median age: 8.2 years, SD: ±4.2 years) were screened via proton transfer reaction mass spectrometry. The patients were treated with valproic acid (VPA) therapy, and blood samples for determination of VPA concentrations were surveyed. All patients showed significantly elevated concentrations of 3-heptanone (C(7)H(14)O) in exhaled breath gas (mean: 14.7 ppb, median: 13.8 ppb SD: ±5.7 ppb). In human breath, several hundred different volatile organic compounds can be detected. In breath of patients with valproic acid monotherapy, an increased concentration of 3-heptanone was measured. The objective of this study was to investigate if serum VPA concentrations correlate with 3-heptanone concentrations in exhaled breath. In conclusion, 3-heptanone in breath gas is significantly elevated in patients treated with the valproic acid, but does not correlate significantly with the VPA concentrations in serum or the daily dose of this drug.

10.
J Chromatogr A ; 1035(2): 261-4, 2004 May 07.
Article in English | MEDLINE | ID: mdl-15124819

ABSTRACT

A pulse-discharge helium ionisation detector, PDHID (Valco, PD-D2-I) with sample introduced to the discharge zone is shown to be applicable for reliable determinations of neon by gas chromatography. The detection level of 80 pg was obtained, but the dependence between detector response and neon mass was non-linear. However, for the discharge gas doped with 33 ppm of neon, a linear response to the neon mass up to 10(-5) g and the detection level of 0.5 ng were obtained. The method can be used for measuring neon concentrations in groundwater systems for hydrogeological purposes.


Subject(s)
Chromatography, Gas/methods , Helium/chemistry
11.
J Chromatogr A ; 968(1-2): 263-7, 2002 Aug 30.
Article in English | MEDLINE | ID: mdl-12236511

ABSTRACT

A pulse-discharge helium detector (Valco, PD-D2-I) is used to measure neon concentrations in air and water. The detection level is 0.5 x 10(-8) g/cm3 (0.2 ppm). Discharge gas doped with neon results in a linear response to the neon mass up to 10(-6) g. For measuring the neon concentration in water, a simple enrichment system is used.


Subject(s)
Air/analysis , Helium/chemistry , Neon/analysis , Water/chemistry