Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Publication year range
1.
Porto Alegre; Artmed; 2009. 268 p. ilus, tab.
Monography in Portuguese | Sec. Munic. Saúde SP, AHM-Acervo, CAMPOLIMPO-Acervo | ID: sms-2532

Subject(s)
Humans , Head , Neck
2.
Porto Alegre; Artmed; 2009. 268 p. ilus, tab.
Monography in Portuguese | LILACS, AHM-Acervo, CAMPOLIMPO-Acervo | ID: lil-642142

Subject(s)
Humans , Head , Neck
3.
AJR Am J Roentgenol ; 183(5): 1355-9, 2004 Nov.
Article in English | MEDLINE | ID: mdl-15505303

ABSTRACT

OBJECTIVE: The purpose of this study was to assess the feasibility of MDCT colonography in an ultra-low-dose technique in the detection of endoluminal colonic lesions compared with high-resolution video colonoscopy. SUBJECTS AND METHODS: After standard bowel cleansing, 137 patients (77 men, 60 women; mean [+/- SD] age, 57.1 +/- 11.3 years) underwent high-resolution video colonoscopy within 2 hr after ultra-low-dose MDCT colonography had been performed. Ultra-low-dose MDCT colonography was performed with patients in the supine position only using 10 mAs (effective weighted CT dose index, 0.94 mGy). After mathematic noise reduction by nonlinear gaussian filter chains, using dedicated software (ECCET), images were analyzed by two blinded observers in simultaneously displayed interactive 2D and 3D modes. Findings of ultra-low-dose MDCT colonography were compared with the results obtained with high-resolution video colonoscopy. RESULTS: Calculated effective doses were 0.7 and 1.2 mSv for men and women, respectively. Ultra-low-dose MDCT colonography detected 84 (62%) of 135 lesions: 11 (78.6%) of 14 large polyps (> 10 mm), 12 (85.7%) of 14 medium polyps (9.9-5 mm), and 61 (57%) of 107 small polyps (< 5 mm). On a patient-by-patient basis, an overall sensitivity of 70.3% with a specificity of 80.8% was calculated. False-positive findings were seen mostly for small lesions (eight medium and 29 small lesions). Two of the three false-negative lesions were retrospectively detected in contrast-enhanced cleansing fluid; one was a flat lipoma not detectable on ultra-low-dose MDCT colonography. CONCLUSION: Despite an effective dose of approximately 1 mSv, MDCT colonography using an ultra-low-dose technique performs as well as MDCT colonography with a standard dose, according to published data. After mathematic noise reduction, 82% of polyps larger than 5 mm can be detected.


Subject(s)
Colonography, Computed Tomographic , Colonoscopy , Colorectal Neoplasms/diagnosis , Colon/pathology , Colonic Polyps/diagnosis , False Negative Reactions , False Positive Reactions , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Radiation Dosage , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...