Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Perm J ; 23: 18-063, 2019.
Article in English | MEDLINE | ID: mdl-30624202

ABSTRACT

INTRODUCTION: Melanosis coli is a condition in which the colon develops a brown to black discoloration. It is associated with chronic laxative use and frequently diagnosed incidentally during colonoscopy or histopathologic evaluation. CASE PRESENTATION: A 74-year-old woman presented to the Emergency Department with severe abdominal pain and bilious emesis. During a cecal volvulus repair, her melanosis coli was nearly misdiagnosed as bowel ischemia. DISCUSSION: Melanosis coli is a diagnostic finding that can easily be confused with bowel ischemia, which may create a dilemma for the surgeon who is attempting to make a decision regarding the extent of a colonic resection. As such, a pathology consult is warranted in any patient with suspected ischemic colitis and concerns for concomitant melanosis coli.


Subject(s)
Colonic Diseases/diagnosis , Aged , Colonic Diseases/complications , Colonic Diseases/surgery , Diagnosis, Differential , Female , Humans , Intestinal Volvulus/complications , Intestinal Volvulus/diagnosis
2.
Anesth Analg ; 119(4): 920-925, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25036374

ABSTRACT

BACKGROUND: Rainbow Pulse CO-Oximetry technology (Masimo Corporation, Irvine, CA) provides continuous and noninvasive measurement of arterial hemoglobin concentration (SpHb). We assessed the trending and accuracy of SpHb by this innovative monitoring compared with Hb concentration obtained with conventional laboratory techniques (Hb) in children undergoing surgical procedures with potential for substantial blood loss. METHODS: Hb concentrations were recorded from Pulse CO-Oximetry and a conventional hematology analyzer. Regression analysis and 4-quadrant plot were used to evaluate the trending for changes in SpHb and Hb measurements (ΔSpHb and ΔHb). Bias, precision, and limits of agreement of SpHb and of in vivo adjusted SpHb (SpHb - first bias to HB) compared with Hb were calculated. RESULTS: One hundred fifty-eight SpHb-Hb data pairs and 105 delta pairs (ΔSpHb and ΔHb) from 46 patients aged 2 months to 17 years with Hb ranging from 16.7 to 7.9 g/dL were collected. To evaluate trending, the delta pairs (ΔSpHb and ΔHb) were plotted, which revealed a positive correlation (ΔSpHb = 0.022 + 0.76ΔHb) with correlation coefficient r = 0.76, 95% CI [confidence interval] = 0.57-0.86. The bias and precision of SpHb to Hb and in vivo adjusted SpHb were 0.4 ± 1.3 g/dL and 0.1 ± 1.2 g/dL, respectively; the limits of agreement were -2.0 to 3.2 g/dL before in vivo adjustment and -2.4 to 2.2 g/dL after in vivo adjustment (P value = 0.04). The mean percent bias (from the reference Hb concentration) decreased from 4.1% ± 11.9% to 0.7% ± 11.3% (P value = 0.01). No drift in bias over time was observed during the study procedure. Of patient demographic and physiological factors tested for correlation with the SpHb, only perfusion index at sensor site showed a weak correlation. CONCLUSIONS: The accuracy of SpHb in children with normal Hb and mild anemia is similar to that previously reported in adults and is independent of patient demographic and physiological states except for a weak correlation with perfusion index. The trending of SpHb and Hb in children with normal Hb and mild anemia showed a positive correlation. Further studies are necessary in children with moderate and severe anemia.


Subject(s)
Erythrocyte Indices/physiology , Monitoring, Intraoperative/standards , Oximetry/standards , Pediatrics/standards , Perioperative Care/standards , Adolescent , Child , Child, Preschool , Female , Hemoglobinometry/standards , Hemoglobinometry/trends , Humans , Infant , Male , Monitoring, Intraoperative/trends , Oximetry/trends , Pediatrics/trends , Perioperative Care/trends , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...