Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
J Am Soc Echocardiogr ; 37(4): 397-404, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38072288

ABSTRACT

BACKGROUND: Transcatheter edge-to-edge repair (TEER) for the treatment of tricuspid regurgitation (TR) has experienced fast adoption following commercial approval. Defining the appropriate target population for TEER therapy is important to guide patient selection. The aim of this study was to characterize tricuspid valve anatomy and coaptation gap in subjects receiving TEER for the treatment of TR in a contemporary postmarket setting. METHODS: The bRIGHT study is a prospective, multicenter, single-arm, postmarket study evaluating the safety and effectiveness of the TriClip device. Procedural outcomes included implant success, acute procedural success, TR severity, major adverse events, single-leaflet device attachment, and embolization through 30 postprocedure days. Tricuspid valve characteristics, including morphology, annulus size, and leaflet mobility, were assessed via two-dimensional transesophageal echocardiography from the screening visit by an independent echo core lab to characterize subject variability. Coaptation gap measurements were taken in both the transgastric short-axis (TG SAX) and RV inflow/outflow views. RESULTS: The independent echo core lab performed a detailed assessment of the tricuspid valve on 135 consecutive subjects with available TG SAX views from 24 sites. Tricuspid valve morphologies included 2 to 5 leaflets, with a non-trileaflet valve in 28% of subjects and ≥4 leaflets in 21% of subjects. The etiology of TR was functional in 91% (96/105), mixed in 7% (7/105), and lead induced in 2% (2/105) of subjects. Leaflet mobility was mildly restricted in 69% (78/113) and moderately restricted in 7% (8/113) of subjects. Annulus diameter averaged 4.7 ± 0.7 cm with a range of 2.5 to 6.2 cm. From the TG SAX view, the coaptation gap measured 8.1 ± 3.1 and 5.2 ± 2.3 mm in the central and mid regions of the anterior-septal coaptation line and 6.6 ± 3.2 and 3.8 ± 2.1 mm in the central and mid regions of the septal-posterior coaptation line, respectively. From the right ventricular inflow/outflow view, the coaptation gap measured 4.7 ± 2.4, 5.2 ± 2.4, and 4.6 ± 3.0 mm in the anterior, mid, and posterior regions of the tricuspid valve, respectively. Thirty-day TR reduction (by number of grades) was similar among subjects with coaptation gaps of <7 mm, 7 to 10 mm, and >10 mm. CONCLUSION: A broad range of anatomies was observed in this postmarket population. Characterization of the tricuspid valve and coaptation gap will help to better understand and better define the target patient population for tricuspid TEER therapy.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Prospective Studies , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Cardiac Catheterization , Tricuspid Valve Insufficiency/diagnosis , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/etiology
2.
Circ Cardiovasc Interv ; 10(10)2017 Oct.
Article in English | MEDLINE | ID: mdl-28951395

ABSTRACT

BACKGROUND: Surgical aortic valve replacement in patients with small annular dimensions is challenging because they are at increased risk for prosthesis-patient mismatch and impaired outcomes. Transcatheter aortic valve replacement might be a good alternative; however, comparative data on different transcatheter heart valves are missing. METHODS AND RESULTS: This multicenter, propensity score-matched study compared hemodynamics and early clinical outcomes in 246 patients with an aortic annulus area <400 mm2 undergoing transcatheter aortic valve replacement with either a self-expanding transcatheter heart valve (Symetis ACURATE neo, n=129) or a balloon-expandable transcatheter heart valve (Edwards SAPIEN 3, n=117). The 1:1 propensity score matching resulted in 92 matched pairs. For ACURATE neo versus SAPIEN 3-treated patients, 30-day mortality (0.0% versus 1.0%), 1-year mortality (8.3% versus 13.3%), incidence of stroke (3.3% versus 2.2%), life-threatening bleeding (1.1% versus 1.1%), and major vascular complications (2.2% versus 6.5%), as well as pacemaker implantation rate (12.0% versus 15.2%), were similar. Paravalvular regurgitation ≥moderate was rare in both groups (4.5% versus 3.6%). The ACURATE neo presented lower mean transvalvular gradients (9.3 versus 14.5 mm Hg; P<0.001), larger indexed effective orifice areas (0.96 versus 0.80 cm2/m2; P=0.003), and lower rates of severe prosthesis-patient mismatch (3% versus 22%; P=0.004). Hemodynamics were sustained at 1-year follow-up. CONCLUSIONS: Albeit a similar safety profile with low clinical event rates, transcatheter aortic valve replacement with the ACURATE neo valve resulted in lower transvalvular gradients and consequently less prosthesis-patient mismatch compared with the SAPIEN 3 in patients with small annulus. These results emphasize the need of careful prosthesis selection in each individual patient.


Subject(s)
Aortic Valve , Heart Valve Prosthesis/statistics & numerical data , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Female , Heart Valve Prosthesis/adverse effects , Hemodynamics , Humans , Male , Propensity Score , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/statistics & numerical data
3.
EuroIntervention ; 12(6): 768-74, 2016 Aug 20.
Article in English | MEDLINE | ID: mdl-27542790

ABSTRACT

AIMS: The aim of this study was to evaluate the safety and performance of the resheathable and repositionable St. Jude Medical Portico self-expanding transfemoral TAVI system. METHODS AND RESULTS: This prospective, single-arm, multicentre study evaluated the 18 Fr Portico system with either a 23 or a 25 mm valve. Patient follow-up was at 30, 90, 180 days and one year. Results up to 30 days are presented. Adverse events were categorised by VARC definitions and adjudicated by an independent events committee. Echocardiography was evaluated by an independent laboratory and all patients underwent neurological assessment at baseline, post procedure, at 30 days and one year. The primary endpoint was all-cause mortality at 30 days. A total of 102 patients (mean age 84.1±4.8 years; 97% female; median STS score 5.6) were enrolled. The 30-day mortality, disabling stroke and major vascular complications were 2.9%, 2.9% and 5.9%, respectively. Resheathing and repositioning (23.8%) was successful in all instances. Paravalvular leak at 30 days was none/trace in 30.4%, mild in 65.8% and moderate in 3.8%. Mean gradient improved from 45.3±13.8 to 8.9±3.8 mmHg and valve area improved from 0.6±0.2 to 1.7±0.4 cm2. Permanent pacemaker implantation was required in 9.8% of patients. CONCLUSIONS: The novel Portico TAVI system is safe and effective at treating high-risk patients with symptomatic severe aortic stenosis, allowing safe repositioning and optimisation of device position.


Subject(s)
Aortic Valve Stenosis/surgery , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve , Echocardiography , Female , Heart Valve Prosthesis , Humans , Male , Prospective Studies , Transcatheter Aortic Valve Replacement/statistics & numerical data , Treatment Outcome
4.
Clin Res Cardiol ; 105(12): 1042-1048, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27535139

ABSTRACT

BACKGROUND: Inverse associations between Body Mass Index (BMI) and Body Surface Area (BSA) with mortality in patients after Transcatheter Aortic Valve Implantation (TAVI) have been reported. This "obesity paradox" is controversial, and it remains unclear which parameter, BMI or BSA, is of greater prognostic value. The aim of this study was to investigate the association of BMI and BSA on short- and mid-term outcomes after TAVI. METHODS AND RESULTS: This prospective, observational study consisted of 917 consecutive patients undergoing TAVI at our center from 2011 to 2014. The association between BMI/BSA and mortality (at 30 days and 1 year) was assessed using restricted cubic spline functions in propensity-adjusted (by Society of Thoracic Surgeons (STS) risk factors) logistic and Cox proportional models, respectively. The median age of the patients was 82.6 years, with a mean STS Predicted Risk of Mortality (STS-PROM) of 6.6 ± 4.3 %. Throughout the study period (mean follow-up time was 297 days), 150 (16.4 %) patients died; 72 (7.9 %) patients died within 30 days of TAVI. After risk adjustment, the association between body constitution and 30-day mortality was not significant for either measure (BMI p = 0.25; BSA p = 0.32). However, BMI (p = 0.01), but not BSA (p = 0.13), was significantly associated with 1-year survival. There was no association between stroke, vascular complications, or length of stay with BMI or BSA. CONCLUSIONS: BMI was associated with survival at 1-year after TAVI. Despite the trend towards implementing BSA in risk score calculation, BMI may be more suitable for the assessment of TAVI patients.


Subject(s)
Aortic Valve Stenosis/therapy , Aortic Valve , Body Mass Index , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/methods , Obesity/complications , Aged , Aged, 80 and over , Aortic Valve/physiopathology , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Body Surface Area , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Humans , Kaplan-Meier Estimate , Logistic Models , Male , Obesity/diagnosis , Obesity/mortality , Obesity/physiopathology , Propensity Score , Proportional Hazards Models , Prospective Studies , Protective Factors , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
5.
Interv Cardiol ; 10(3): 162-166, 2015 Sep.
Article in English | MEDLINE | ID: mdl-29588696

ABSTRACT

The use of drug-eluting stents (DES) has improved clinical outcomes in percutaneous coronary intervention procedures, but many challenges remain. In two symposia at EuroPCR 2015, the factors necessary to ensure successful chronic total occlusion (CTO) intervention were presented. Good preparation, sufficient operator experience and the correct approach are key to the success of CTO interventions. A live case demonstrated the challenges of these complex cases. Stent choice in CTO interventions is crucial; second-generation DES are associated with lower rates of restenosis and re-occlusion compared with first-generation DES. The Coracto™ DES features unique structural properties and rapidly absorbable polymer, resulting in excellent conformability, efficacy and safety.

7.
Heart ; 100(22): 1786-92, 2014 Nov.
Article in English | MEDLINE | ID: mdl-24986894

ABSTRACT

OBJECTIVE: Alterations in cortisol awakening and stress responses (CAR, CSR) are sensitive markers for the basal activity and responsiveness of the hypothalamus-pituitary-adrenal axis (HPAA) in psychopathological conditions. We investigated whether patients with takotsubo cardiomyopathy (TTC) differ in these markers when compared with non-ST-segment elevation myocardial infarction (NSTEMI) patients and healthy controls. METHODS: 19 female TTC patients were compared with 20 female NSTEMI patients and with 20 healthy women, matched by age and index event date. Salivary sampling indicated cortisol release, questionnaires assessed personality, life events, chronic stress and psychiatric symptoms. RESULTS: The groups did not differ relevantly in their basal HPAA activity, psychiatric or personality profiles. Despite increased heart rates in response to stress (median difference (MDdiff)=3.5, p=0.002) and higher nervousness scores (MDdiff=-3.0, p=0.024), TTC patients revealed a blunted CSR with a medium effect compared to the controls (MDdiff=-3.2 nmol/L, p=0.022, r=0.36); even when controlled for prestress cortisol differences (p=0.044, r=0.33). In comparison with NSTEMI patients, no significant differences in CSR (MDdiff=-1.9 nmol/L, p=0.127, r=0.25) or nervousness (MDdiff=2.0, p=0.107) can be observed. Stressful life events, for example, traumatic experiences, occurred more often in TTC (42%) than in NSTEMI patients and controls (both 10%, p=0.031). CONCLUSIONS: In this small exploratory trial, a trend for a blunted CSR and high incidences of stressful life events were observed in TTC patients. If these results can be confirmed in larger studies, chronic stress and the inhibitory influence of cortisol on catecholamine release might be significant for the pathogenesis of TTC.


Subject(s)
Hydrocortisone/metabolism , Myocardial Infarction/physiopathology , Myocardial Infarction/psychology , Pituitary-Adrenal System/physiopathology , Takotsubo Cardiomyopathy/physiopathology , Takotsubo Cardiomyopathy/psychology , Adult , Age Distribution , Analysis of Variance , Case-Control Studies , Disease Progression , Female , Heart Rate/physiology , Humans , Hydrocortisone/analysis , Incidence , Middle Aged , Myocardial Infarction/epidemiology , Personality , Prognosis , Psychometrics , Risk Assessment , Severity of Illness Index , Stress, Psychological , Takotsubo Cardiomyopathy/epidemiology
8.
PLoS One ; 8(3): e55445, 2013.
Article in English | MEDLINE | ID: mdl-23533567

ABSTRACT

BACKGROUND: The phosphatase PTEN represents an important physiological inhibitor of phosphatidylinositol-3 kinase (PI3-K)/protein kinase B (Akt) signalling, however, the functional role of PTEN in the initial phase of angioplasty-induced vascular injury remains elusive. In the present study we sought to determine PTEN's effect on vascular smooth muscle cell (VSMC) apoptosis following acute injury in vivo and in vitro. METHODS AND RESULTS: Immunohistochemistry indicated a faint basal expression and equal distribution of PTEN in uninjured rat carotid arteries. 12 h following balloon-injury, PTEN expression was strongly increased in apoptotic (TUNEL+) VSMC. In vitro, stimulation with serum or different growth factors or subjecting VSMC to cyclic stretch had no effect on PTEN expression, whereas stimulation with H2O2 robustly increased PTEN expression in a time- and dose-dependent manner. To evaluate the functional role of PTEN expression, human VSMC were transduced with WT-PTEN. Overexpression of PTEN increased the number of apoptotic VSMC (19.8%±4.4 vs. 5.6%±2.3; P<0.001) as determined by TUNEL assay. In contrast, siRNA-mediated knock-down of PTEN attenuated the basal as well as H2O2-induced apoptosis of VSMC. Mechanistically, overexpression of PTEN prevented serum-induced Akt-phosphorylation, whereas siRNA-mediated knock down of PTEN augmented Akt-activation. Moreover, co-transfection of PTEN and a constitutive active Akt mutant prevented PTEN-dependent augmentation of VSMC apoptosis, indicating, that PTEN regulates VSMC apoptosis by inhibition of Akt phosphorylation/activation. CONCLUSION: By interfering with the PI3-K/Akt-dependent survival signalling, the oxidative stress-induced up regulation of PTEN in VSMC of injured arteries augments the sensitivity of VSMC to apoptotic stimuli in the early phase following vascular injury, augmenting the initial injury and cell loss of the injured vessel wall. Thus, these data add to our understanding of PTEN's role during vascular remodelling.


Subject(s)
PTEN Phosphohydrolase/metabolism , Angioplasty, Balloon , Animals , Apoptosis/physiology , Carotid Artery, Common/cytology , Carotid Artery, Common/metabolism , Cell Proliferation , Cells, Cultured , Humans , Immunohistochemistry , In Vitro Techniques , Male , Muscle, Smooth, Vascular/cytology , Myocytes, Smooth Muscle/cytology , Myocytes, Smooth Muscle/metabolism , PTEN Phosphohydrolase/genetics , Phosphatidylinositol 3-Kinases/metabolism , Proto-Oncogene Proteins c-akt/metabolism , RNA Interference , Rats
9.
Thorac Cardiovasc Surg ; 61(5): 409-13, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23247690

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (T-AVI) by using the Edwards SAPIEN (Edwards Lifesciences LLC, Irvine, California, United States) prosthesis is currently being performed by the implantation of valved stent into the aortic annulus without respecting the native commissural (rotational) orientation. Anatomical orientation may, however, be beneficial regarding optimal physiological valve performance, optimal coronary flow, and avoidance of the fully covered commissural stent part in front of the coronary ostia. With the recently introduced SAPIEN XT, transcatheter valve identification of the commissures during fluoroscopy is feasible. The aim of this study was to evaluate the concept of Dynamic-CT (DynaCT)-guided anatomical rotation of the SAPIEN XT valve during transapical-AVI (TA-AVI). METHODS: Intraoperatively, an automatically segmented DynaCT was performed using the Siemens Syngo Aortic ValveGuide (Siemens AG, Forchheim, Germany) software prototype. Commissures of SAPIEN XT could be identified with a high-quality fluoroscopic system. Before standard TA implantation, one radiopaque stent commissure of the crimped SAPIEN XT prosthesis was aligned with the native aortic valve commissure visualized by DynaCT. Resulting rotational orientation of the valve after implantation was assessed by transesophageal echocardiography. RESULTS: Feasibility of anatomical rotation was evaluated in 10 patients scheduled for TA-AVI by an interdisciplinary heart team. Mean logistic EuroSCOREs and Society of Thoracic Surgeons scores were 23.7 ± 4.9% and 8.6 ± 2.1%, mean aortic gradient improved from 46.0 ± 21.9 to 9.6 ± 3.1 mm Hg, and there was no death within 30 days. All valves were implanted successfully with none or trivial paravalvular regurgitation in seven patients, mild (1 + ) in two patients, and moderate (2 + ) in one patient. An optimal anatomical position could be achieved in six patients, minor rotational deviation (< 10 degrees) in three patients, and moderate deviation (10 to 20 degrees) in one patient only. CONCLUSIONS: DynaCT-guided anatomical rotation of the SAPIEN XT valve is feasible during TA-AVI, avoiding implantation of the fully covered commissural posts in front of the coronary ostia. This might reduce the risk of coronary obstruction. In addition, the technique provides the potential benefit of physiological valve position and performance.


Subject(s)
Aortic Valve Stenosis/therapy , Aortic Valve/diagnostic imaging , Cardiac Catheterization/instrumentation , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Radiography, Interventional , Therapy, Computer-Assisted , Tomography, X-Ray Computed , Aged , Aged, 80 and over , Aortic Valve/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Cardiac Catheterization/adverse effects , Echocardiography, Transesophageal , Feasibility Studies , Heart Valve Prosthesis Implantation/adverse effects , Humans , Predictive Value of Tests , Prosthesis Design , Radiographic Image Interpretation, Computer-Assisted , Software , Time Factors , Treatment Outcome
10.
Ann Thorac Surg ; 94(5): 1706-9, 2012 Nov.
Article in English | MEDLINE | ID: mdl-23098947

ABSTRACT

PURPOSE: Transapical aortic valve implantation (TA-AVI) has evolved as a treatment option for high-risk patients who have severe aortic stenosis. The aim of this study was to evaluate the feasibility of a novel apical closure device to allow for standardized apical access and closure. DESCRIPTION: The Apica ASC system consists of three components: an introducer system, a left ventricular low-profile titanium coil, and a closure cap. The ASC introducer system is fixed to the myocardium by anchoring the titanium coil into the epicardium. After the TA-AVI procedure, the closure cap is introduced through the system and delivered onto the titanium coil for final sealing. EVALUATION: After sternotomy, fixation of the introducer system was successfully performed in an acute pig model. The apex was safely secured in all attempts, and the titanium coil created an effective seal around the Ascendra sheath. Finally, the closure cap was shown to be secure even when the hearts were pressurized to 200 mm Hg. Postmortem examination showed a uniform depth of the titanium coil through the endocardium into the myocardial wall without penetration into the left ventricular cavity. CONCLUSIONS: Apical access and closure is feasible using the sutureless Apica ASC device. The system seems to have the potential to further standardize the TA-AVI procedure, allowing wider applicability and more generalizability.


Subject(s)
Heart Valve Prosthesis Implantation/methods , Wound Closure Techniques/instrumentation , Animals , Equipment Design , Feasibility Studies , Male , Swine
11.
Eur Radiol ; 22(12): 2662-9, 2012 Dec.
Article in English | MEDLINE | ID: mdl-22688129

ABSTRACT

OBJECTIVES: In transcatheter aortic valve implantation (TAVI), assessment of the aortic annulus is mandatory. We sought to investigate the correlation between trans-oesophageal echocardiography (TEE) and multi-detector computed tomography (MDCT) for annulus diameter assessment before TAVI. METHODS: A total of 122 patients (67 male, mean age 84 ± 6 years) underwent MDCT and TEE for TAVI planning. In TEE annulus diameters were obtained in a long-axis view at diastole. MDCT data were evaluated using MPR images, and corresponding projections were adjusted for MDCT and TEE. Patients were classified by the predominant localisation of aortic valve calcifications, and annulus diameters between TEE and MDCT were correlated. Additionally, the eccentricity of the aortic annulus was calculated. RESULTS: Mean eccentricity of the aortic annulus determined by MDCT was 0.34 ± 0.17, with no difference according to valve calcification. Regarding the aortic annulus diameter, the mean values measured were 24.3 ± 2.1 mm in MDCT and 24.0 ± 2.5 mm in TEE (P < 0.0001 for agreement). CONCLUSIONS: Independent of the pattern of aortic valve calcification, close correlation is found between CT and TEE measurements of the aortic annulus diameter. In addition, CT demonstrates the non-circular shape of the aortic annulus. KEY POINTS: Accurate assessment of aortic annulus before transcatheter aortic valve implantation is crucial. Trans-oesophageal echocardiography has been the preferred method for aortic annulus assessment. We demonstrated a strong correlation between TEE and CT for annulus dimensions. CT reliably demonstrates the non-circular shape of the aortic annulus. CT could therefore be generally used for aortic annulus assessment before TAVI.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Aortic Valve/diagnostic imaging , Cardiac Catheterization , Echocardiography, Transesophageal/methods , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Tomography, X-Ray Computed/methods , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Artifacts , Contrast Media , Female , Humans , Image Interpretation, Computer-Assisted , Iopamidol , Male , Preoperative Care , Prospective Studies , Reproducibility of Results , Statistics, Nonparametric
12.
Expert Rev Med Devices ; 9(1): 15-22, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22145837

ABSTRACT

With the rapid evolution of transcatheter aortic valve implantation over the past few years, transapical access has evolved to be a routine approach for the implantation of transcatheter aortic valve prostheses. The approach itself has demonstrated feasibility, safety and reproducibility associated with low complication rates. As the access allows for relatively large profile devices and owing to the short anatomical distance to both the mitral and the aortic valve, the apical approach facilitates a wide range of interventions. Thus, minimally invasive transapical access can be considered as a versatile platform for the development of new transcatheter aortic or mitral devices.


Subject(s)
Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/trends , Aortic Valve/surgery , Cardiovascular Surgical Procedures/trends , Equipment and Supplies , Heart Valve Prosthesis Implantation/adverse effects , Humans
13.
Am Heart J ; 162(1): 81-8, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21742093

ABSTRACT

BACKGROUND: In the present study, we aimed to analyze the diagnostic and prognostic potential of a newly developed high-sensitive troponin T assay and compared these results with those of a contemporary troponin T assay in 2 distinct patient cohorts, one including patients with evident ACS and the other one including patients with general chest pain. METHODS AND RESULTS: For this study, we analyzed data from 2 independent patient cohorts, the Bad Nauheim ACS registry and the Prognosis in Acute Coronary Syndromes registry, with a total of 2,506 patients. On admission, clinical data have been recorded, and a single measurement of troponin T has been performed with a contemporary assay (TnT) and a new high-sensitive troponin T assay (hsTnT). Clinical follow-up has been obtained after 6 months. The diagnostic value of hsTnT was superior to TnT (area under the receiver operating characteristic curve 0.949 vs 0.929, P = .016). Specifically, in TnT-negative patients, hsTnT provided strong diagnostic information (area under the receiver operating characteristic curve of 0.81, P < .001). Furthermore, hsTnT provided independent prognostic power for mortality within 6 months in both cohorts, which was superior to that of the contemporary TnT assay. CONCLUSION: Troponin T measured with a newly developed hsTnT provides better diagnostic and prognostic information and, therefore, should be implemented as a standard test in clinical routine.


Subject(s)
Acute Coronary Syndrome/diagnosis , Biomarkers/blood , Troponin T/blood , Acute Coronary Syndrome/blood , Aged , Diagnosis, Differential , Female , Follow-Up Studies , Humans , Immunoassay , Male , Middle Aged , Prognosis , ROC Curve , Registries , Retrospective Studies , Severity of Illness Index
14.
Circ J ; 73(2): 316-22, 2009 Feb.
Article in English | MEDLINE | ID: mdl-19122307

ABSTRACT

BACKGROUND: Computed tomography (CT) enables detection of coronary artery stenoses, but its use is limited by deficient evaluation at elevated heart rates. The accuracy of dual-source CT (DSCT) for the detection of coronary artery disease (CAD) was assessed in 76 patients at high probability of CAD without heart rate control and compared with quantitative coronary angiography (QCA). Methods and Results The 76 patients (47 males, mean age 65.5+/-10 years) underwent DSCT without preceding heart rate control. Data sets were evaluated by 2 observers in consensus with respect to stenoses >50% decreased diameter. QCA served as the standard of reference. Mean heart rate during scanning was 68+/-9 beats per min, and the average Agatston score was 337+/-560. Of 1,160 coronary artery segments, all but 3 were visualized artefact-free; 58 coronary stenoses were correctly detected by CT angiography. In the segment-based analysis, sensitivity was 98.3%, specificity 99.2% and accuracy 99%; patient based analysis revealed a sensitivity of 100%, specificity of 83.3% and overall accuracy of 92.1%. Conclusions Even at elevated heart rates, DSCT can reliably detect coronary artery stenoses and the results correlate well with those for invasive coronary angiography.


Subject(s)
Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Tomography, X-Ray Computed/methods , Aged , Coronary Artery Disease/physiopathology , Dose-Response Relationship, Radiation , Female , Heart Rate/physiology , Humans , Male , Middle Aged , Sensitivity and Specificity
15.
Eur J Heart Fail ; 10(5): 482-9, 2008 May.
Article in English | MEDLINE | ID: mdl-18436476

ABSTRACT

AIMS: To analyse the contribution of recently described genetic polymorphisms in the human natriuretic peptide receptor (NPR-A) to the interindividual variability in the BNP system. METHODS AND RESULTS: We evaluated NT-proBNP in 402 subjects, including healthy controls (n=93), patients with acute coronary syndrome (n=194) and heart failure (n=115). Three polymorphic sites encoding six common haplotypes of the NPR-A receptor gene, including three haplotypes in the 5' region (CT11, CT10 and CT6) and three haplotypes in the 3' region (3-plus, 4-minus and 4-plus), were studied. The frequency of the identified "4-minus" haplotype was higher in control subjects with high NT-proBNP (>75th percentile) levels as compared to those with low NT-proBNP levels (15.2% vs. 5.7%, p<0.05). In the control subjects, carriers of the "4-plus/4-minus" genotype had about 2-fold higher median NT-proBNP levels than individuals with other genetic variants (142 pg/ml (88-371 pg/ml) vs. 71 pg/ml (35-111 pg/ml, p=0.011). In contrast, in patients with cardiovascular disorders no relation between NT-proBNP and the described polymorphisms was observed. CONCLUSION: The "4-minus" haplotype of the NPR-A receptor gene is associated with high NT-proBNP values and is a genetic determinant of the interindividual variability in the BNP system in healthy individuals but probably not in patients with cardiovascular disorders.


Subject(s)
Heart Diseases/blood , Heart Diseases/genetics , Natriuretic Peptide, Brain/physiology , Peptide Fragments/blood , Polymorphism, Genetic , Receptors, Atrial Natriuretic Factor/genetics , Aged , Female , Genetic Variation , Haplotypes , Humans , Male , Middle Aged , Natriuretic Peptide, Brain/blood
16.
Eur Radiol ; 18(9): 1857-62, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18418605

ABSTRACT

Multi-detector CT reliably permits visualization of coronary arteries, but due to the occurrence of motion artefacts at heart rates >65 bpm caused by a temporal resolution of 165 ms, its utilisation has so far been limited to patients with a preferably low heart rate. We investigated the assessment of image quality on computed tomography of coronary arteries in a large series of patients without additional heart rate control using dual-source computed tomography (DSCT). DSCT (Siemens Somatom Definition, 83-ms temporal resolution) was performed in 165 consecutive patients (mean age 64 +/- 11.4 years) after injection of 60-80 ml of contrast. Data sets were reconstructed in 5% intervals of the cardiac cycle and evaluated by two readers in consensus concerning evaluability of the coronary arteries and presence of motion and beam-hardening artefacts using the AHA 16-segment coronary model. Mean heart rate during CT was 65 +/- 10.5 bpm; visualisation without artefacts was possible in 98.7% of 2,541 coronary segments. Only two segments were considered unevaluable due to cardiac motion; 30 segments were unassessable due to poor signal-to-noise ratio or coronary calcifications (both n = 15). Data reconstruction at 65-70% of the cardiac cycle provided for the best image quality. For heart rates >85 bpm, a systolic reconstruction at 45% revealed satisfactory results. Compared with earlier CT generations, DSCT provides for non-invasive coronary angiography with diagnostic image quality even at heart rates >65 bpm and thus may broaden the spectrum of patients that can be investigated non-invasively.


Subject(s)
Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
17.
Int J Cardiol ; 127(3): 321-7, 2008 Jul 21.
Article in English | MEDLINE | ID: mdl-18055041

ABSTRACT

BACKGROUND: BNP and its N-terminal fragment NT-proBNP have proven to be of diagnostic and prognostic value in patients with valvular aortic stenosis. Data regarding those biomarkers in patients with chronic aortic regurgitation (AR) are sparse. Thus it was the aim of the present study to evaluate the diagnostic and the long term prognostic value of NT-proBNP in patients presenting with AR. METHODS AND RESULTS: This study included 60 patients with isolated AR of varying severity (AR I mild, AR II moderate and AR III severe) and preserved left ventricular function. Patients were followed over a median period of 824 (770-921) days. NT-proBNP at baseline was related to disease severity and to functional status (161 (70-456) pg/ml in AR I, 226 (100-666) pg/ml in AR II and 1268 (522-5446) pg/ml in AR III (p=0.003)). Patients (n=6) experiencing an adverse event had higher NT-proBNP values at baseline as event free survivors (1271 (613-2992) pg/ml vs. 215 (92-534) pg/ml; p=0.034). The AUC of the ROC curve for NT-proBNP as a predictor for an adverse event was 0.76 (p<0.036) with an optimised cut-off value of 602 pg/ml. Consequently, in Kaplan-Meier analysis NT-proBNP values dichotomised at this cut-off were able to discriminate patients with an adverse outcome in the entire study group (Log rank 9.98, p=0.0016) and even better in the conservative group (Log rank 26.92, p<0.001). CONCLUSION: NT-proBNP is linked to disease severity in patients with chronic aortic regurgitation reflecting hemodynamic stress due to volume overload. It provides prognostic information for the clinical outcome and thus might be a useful biomarker for risk stratification.


Subject(s)
Aortic Valve Insufficiency/blood , Aortic Valve Insufficiency/diagnosis , Natriuretic Peptide, Brain/blood , Peptide Fragments/blood , Protein Precursors/blood , Adult , Aged , Aortic Valve Insufficiency/physiopathology , Biomarkers/blood , Chronic Disease , Female , Follow-Up Studies , Humans , Male , Middle Aged , Predictive Value of Tests , Prognosis , Severity of Illness Index , Stroke Volume
SELECTION OF CITATIONS
SEARCH DETAIL
...