Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
1.
Euro Surveill ; 28(40)2023 10.
Article in English | MEDLINE | ID: mdl-37796441

ABSTRACT

BackgroundRodent-borne viruses such as orthohantaviruses and arenaviruses cause considerable disease burden with regional and temporal differences in incidence and clinical awareness. Therefore, it is important to regularly evaluate laboratory diagnostic capabilities, e.g. by external quality assessments (EQA).AimWe wished to evaluate the performance and diagnostic capability of European expert laboratories to detect orthohantaviruses and lymphocytic choriomeningitis virus (LCMV) and human antibody response towards orthohantaviruses.MethodsWe conducted an EQA in 2021; molecular panels consisted of 12 samples, including different orthohantaviruses (Seoul, Dobrava-Belgrade (DOBV), Puumala (PUUV) and Hantaan orthohantavirus), LCMV and negative controls. Serological panels consisted of six human serum samples reactive to PUUV, DOBV or negative to orthohantaviruses. The EQA was sent to 25 laboratories in 20 countries.ResultsThe accuracy of molecular detection of orthohantaviruses varied (50‒67%, average 62%) among 16 participating laboratories, while LCMV samples were successfully detected in all 11 participating laboratories (91-100%, average 96%). The accuracy of serological diagnosis of acute and past orthohantavirus infections was on average 95% among 20 participating laboratories and 82% in 19 laboratories, respectively. A variety of methods was used, with predominance of in-house assays for molecular tests, and commercial assays for serological ones.ConclusionSerology, the most common tool to diagnose acute orthohantavirus infections, had a high accuracy in this EQA. The molecular detection of orthohantaviruses needs improvement while LCMV detection (performed in fewer laboratories) had 95% accuracy. Further EQAs are recommended to be performed periodically to monitor improvements and challenges in the diagnostics of rodent-borne diseases.


Subject(s)
Hantavirus Infections , Orthohantavirus , Humans , Lymphocytic choriomeningitis virus/genetics , Europe/epidemiology , Hantavirus Infections/diagnosis , Antibodies, Viral
2.
J Virol Methods ; 322: 114825, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37778539

ABSTRACT

One consequence of the ongoing coronavirus disease pandemic was the rapid development of both in-house and commercial serological assays detecting anti-SARS-CoV-2 antibodies, in an effort to reliably detect acute and past SARS-CoV-2 infections. It is crucial to evaluate the quality of these serological tests and consequently the sero-epidemiological studies that are performed with the respective tests. Here, we describe the set-up and results of a comparative study, in which a laboratory contracted by the European Centre for Disease Prevention and Control offered a centralised service to EU/EEA Member and pre-accession Member States to test representative serum specimens with known serological results, with the gold standard technique (virus neutralisation tests) to determine the presence of neutralising antibodies. Laboratories from 12 European countries shared 719 serum specimens with the contractor laboratory. We found that in-house serological tests detecting neutralising antibodies showed the highest percent agreement, both positive and negative, with the virus neutralisation test results. Despite extensive differences in virus neutralisation protocols neutralisation titres showed a strong correlation. From the commercial assays, the best positive percent agreement was found for SARS-CoV-2 IgG (sCOVG) (Siemens - Atellica IM Analyzer). Despite lower positive percent agreement of LIAISON SARS-CoV-2 TrimericS IgG kit (Diasorin Inc.), the obtained results showed relatively good correlation with neutralisation titres. The set-up of this study allowed for high comparability between laboratories and enabled laboratories that do not have the capacity or capability to perform VNTs themselves. Given the variety of in-house protocols detecting SARS-CoV-2 specific neutralising antibodies, including the virus strain, it could be of interest to select reference isolates for SARS-CoV-2 diagnostic to be made available for interested EU Member States and pre-accession countries.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , SARS-CoV-2 , COVID-19 Testing , Clinical Laboratory Techniques/methods , Antibodies, Viral , Europe , Immunoglobulin G , Antibodies, Neutralizing
3.
J Clin Microbiol ; 60(12): e0126122, 2022 12 21.
Article in English | MEDLINE | ID: mdl-36445090

ABSTRACT

The molecular detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is key for clinical management and surveillance. Funded by the European Centre for Disease Prevention and Control, we conducted an external quality assessment (EQA) on the molecular detection and variant typing of SARS-CoV-2 that included 59 European laboratories in 34 countries. The EQA panel consisted of 12 lyophilized inactivated samples, 10 of which were SARS-CoV-2 variants (Alpha, Beta, Gamma, Delta, Epsilon, Eta, parental B.1 strain) ranging from 2.5 to 290.0 copies/µL or pooled respiratory viruses (adenovirus, enterovirus, influenza virus A, respiratory syncytial virus, or human coronaviruses 229E and OC43). Of all participants, 72.9% identified the presence of SARS-CoV-2 RNA correctly. In samples containing 25.0 or more genome copies/µL, SARS-CoV-2 was detected by 98.3% of the participating laboratories. Laboratories applying commercial tests scored significantly better (P < 0.0001, Kruskal-Wallis test) than those using in-house assays. Both the molecular detection and the typing of the SARS-CoV-2 variants were associated with the RNA concentrations (P < 0.0001, Kruskal-Wallis test). On average, only 5 out of the 10 samples containing different SARS-CoV-2 variants at different concentrations were correctly typed. The identification of SARS-CoV-2 variants was significantly more successful among EQA participants who combined real-time reverse transcription polymerase chain reaction (RT-PCR)-based assays for mutation detection and high-throughput genomic sequencing than among those who used a single methodological approach (P = 0.0345, Kruskal-Wallis test). Our data highlight the high sensitivity of SARS-CoV-2 detection in expert laboratories as well as the importance of continuous assay development and the benefits of combining different methodologies for accurate SARS-CoV-2 variant typing.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , Laboratories , RNA, Viral , SARS-CoV-2/genetics , Sensitivity and Specificity
4.
Euro Surveill ; 27(42)2022 10.
Article in English | MEDLINE | ID: mdl-36268736

ABSTRACT

BackgroundCountries worldwide are focusing to mitigate the ongoing SARS-CoV-2 pandemic by employing public health measures. Laboratories have a key role in the control of SARS-CoV-2 transmission. Serology for SARS-CoV-2 is of critical importance to support diagnosis, define the epidemiological framework and evaluate immune responses to natural infection and vaccine administration.AimThe aim of this study was the assessment of the actual capability among laboratories involved in sero-epidemiological studies on COVID-19 in EU/EEA and EU enlargement countries to detect SARS-CoV-2 antibodies through an external quality assessment (EQA) based on proficiency testing.MethodsThe EQA panels were composed of eight different, pooled human serum samples (all collected in 2020 before the vaccine roll-out), addressing sensitivity and specificity of detection. The panels and two EU human SARS-CoV-2 serological standards were sent to 56 laboratories in 30 countries.ResultsThe overall performance of laboratories within this EQA indicated a robust ability to establish past SARS-CoV-2 infections via detection of anti-SARS-CoV-2 antibodies, with 53 of 55 laboratories using at least one test that characterised all EQA samples correctly. IgM-specific test methods provided most incorrect sample characterisations (24/208), while test methods detecting total immunoglobulin (0/119) and neutralising antibodies (2/230) performed the best. The semiquantitative assays used by the EQA participants also showed a robust performance in relation to the standards.ConclusionOur EQA showed a high capability across European reference laboratories for reliable diagnostics for SARS-CoV-2 antibody responses. Serological tests that provide robust and reliable detection of anti-SARS-CoV-2 antibodies are available.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Laboratories , Antibodies, Viral , Sensitivity and Specificity , Immunoglobulin M , Antibodies, Neutralizing
5.
Sci Adv ; 7(36): eabj5365, 2021 Sep 03.
Article in English | MEDLINE | ID: mdl-34516917

ABSTRACT

Emerging SARS-CoV-2 variants of concern (VOCs) pose a threat to human immunity induced by natural infection and vaccination. We assessed the recognition of three VOCs (B.1.1.7, B.1.351, and P.1) in cohorts of COVID-19 convalescent patients (n = 69) and Pfizer-BioNTech vaccine recipients (n = 50). Spike binding and neutralization against all three VOCs were substantially reduced in most individuals, with the largest four- to sevenfold reduction in neutralization being observed against B.1.351. While hospitalized patients with COVID-19 and vaccinees maintained sufficient neutralizing titers against all three VOCs, 39% of nonhospitalized patients exhibited no detectable neutralization against B.1.351. Moreover, monoclonal neutralizing antibodies show sharp reductions in their binding kinetics and neutralizing potential to B.1.351 and P.1 but not to B.1.1.7. These data have implications for the degree to which pre-existing immunity can protect against subsequent infection with VOCs and informs policy makers of susceptibility to globally circulating SARS-CoV-2 VOCs.

6.
medRxiv ; 2021 Jun 01.
Article in English | MEDLINE | ID: mdl-34100023

ABSTRACT

Emerging SARS-CoV-2 variants pose a threat to human immunity induced by natural infection and vaccination. We assessed the recognition of three variants of concern (B.1.1.7, B.1.351 and P.1) in cohorts of COVID-19 patients ranging in disease severity (n = 69) and recipients of the Pfizer/BioNTech vaccine (n = 50). Spike binding and neutralization against all three VOC was substantially reduced in the majority of samples, with the largest 4-7-fold reduction in neutralization being observed against B.1.351. While hospitalized COVID-19 patients and vaccinees maintained sufficient neutralizing titers against all three VOC, 39% of non-hospitalized patients did not neutralize B.1.351. Moreover, monoclonal neutralizing antibodies (NAbs) show sharp reductions in their binding kinetics and neutralizing potential to B.1.351 and P.1, but not to B.1.1.7. These data have implications for the degree to which pre-existing immunity can protect against subsequent infection with VOC and informs policy makers of susceptibility to globally circulating SARS-CoV-2 VOC.

7.
J Clin Microbiol ; 59(3)2021 02 18.
Article in English | MEDLINE | ID: mdl-33298612

ABSTRACT

During the ongoing coronavirus disease 2019 (COVID-19) outbreak, robust detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a key element for clinical management and to interrupt transmission chains. We organized an external quality assessment (EQA) of molecular detection of SARS-CoV-2 for European expert laboratories. An EQA panel composed of 12 samples, containing either SARS-CoV-2 at different concentrations to evaluate sensitivity or other respiratory viruses to evaluate specificity of SARS-CoV-2 testing, was distributed to 68 laboratories in 35 countries. Specificity samples included seasonal human coronaviruses hCoV-229E, hCoV-NL63, and hCoV-OC43, as well as Middle East respiratory syndrome coronavirus (MERS-CoV), SARS-CoV, and human influenza viruses A and B. Sensitivity results differed among laboratories, particularly for low-concentration SARS-CoV-2 samples. Results indicated that performance was mostly independent of the selection of specific extraction or PCR methods.


Subject(s)
COVID-19 Testing/standards , COVID-19/diagnosis , Coronavirus 229E, Human , Coronavirus NL63, Human , Coronavirus OC43, Human , Humans , Alphainfluenzavirus , Betainfluenzavirus , Laboratories , Middle East Respiratory Syndrome Coronavirus , Severe acute respiratory syndrome-related coronavirus , SARS-CoV-2 , Sensitivity and Specificity
8.
Emerg Microbes Infect ; 9(1): 1965-1973, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32819220

ABSTRACT

Serology is a crucial part of the public health response to the ongoing SARS-CoV-2 pandemic. Here, we describe the development, validation and clinical evaluation of a protein micro-array as a quantitative multiplex immunoassay that can identify S and N-directed SARS-CoV-2 IgG antibodies with high specificity and sensitivity and distinguish them from all currently circulating human coronaviruses. The method specificity was 100% for SARS-CoV-2 S1 and 96% for N antigen based on extensive syndromic (n=230 cases) and population panel (n=94) testing that also confirmed the high prevalence of seasonal human coronaviruses. To assess its potential role for both SARS-CoV-2 patient diagnostics and population studies, we evaluated a large heterogeneous COVID-19 cohort (n=330) and found an overall sensitivity of 89% (≥ 21 days post onset symptoms (dps)), ranging from 86% to 96% depending on severity of disease. For a subset of these patients longitudinal samples were provided up to 56 dps. Mild cases showed absent or delayed, and lower SARS-CoV-2 antibody responses. Overall, we present the development and extensive clinical validation of a multiplex coronavirus serological assay for syndromic testing, to answer research questions regarding to antibody responses, to support SARS-CoV-2 diagnostics and to evaluate epidemiological developments efficiently and with high-throughput.


Subject(s)
Antibodies, Viral/blood , Betacoronavirus/immunology , Clinical Laboratory Techniques/methods , Coronavirus Infections/diagnosis , Nucleocapsid Proteins/blood , Pneumonia, Viral/diagnosis , Spike Glycoprotein, Coronavirus/blood , Aged , Antigens, Viral/blood , Antigens, Viral/immunology , Betacoronavirus/pathogenicity , COVID-19 , COVID-19 Testing , Clinical Laboratory Techniques/standards , Coronavirus Infections/immunology , Coronavirus Infections/mortality , Coronavirus Infections/virology , Coronavirus Nucleocapsid Proteins , Female , Humans , Longitudinal Studies , Male , Middle Aged , Middle East Respiratory Syndrome Coronavirus/immunology , Middle East Respiratory Syndrome Coronavirus/pathogenicity , Neutralization Tests , Nucleocapsid Proteins/immunology , Pandemics , Phosphoproteins , Pneumonia, Viral/immunology , Pneumonia, Viral/mortality , Pneumonia, Viral/virology , Protein Array Analysis , Severe acute respiratory syndrome-related coronavirus/immunology , Severe acute respiratory syndrome-related coronavirus/pathogenicity , SARS-CoV-2 , Sensitivity and Specificity , Severity of Illness Index , Spike Glycoprotein, Coronavirus/immunology
9.
Emerg Infect Dis ; 26(8): 1944-1946, 2020 08.
Article in English | MEDLINE | ID: mdl-32433015
10.
Euro Surveill ; 24(50)2019 12.
Article in English | MEDLINE | ID: mdl-31847946

ABSTRACT

BackgroundNeurotropic arboviruses are increasingly recognised as causative agents of neurological disease in Europe but underdiagnosis is still suspected. Capability for accurate diagnosis is a prerequisite for adequate clinical and public health response.AimTo improve diagnostic capability in EVD-LabNet laboratories, we organised an external quality assessment (EQA) focusing on molecular detection of Toscana (TOSV), Usutu (USUV), West Nile (WNV) and tick-borne encephalitis viruses (TBEV).MethodsSixty-nine laboratories were invited. The EQA panel included two WNV RNA-positive samples (lineages 1 and 2), two TOSV RNA-positive samples (lineages A and B), one TBEV RNA-positive sample (Western subtype), one USUV RNA-positive sample and four negative samples. The EQA focused on overall capability rather than sensitivity of the used techniques. Only detection of one, clinically relevant, concentration per virus species and lineage was assessed.ResultsThe final EQA analysis included 51 laboratories from 35 countries; 44 of these laboratories were from 28 of 31 countries in the European Union/European Economic Area (EU/EEA). USUV diagnostic capability was lowest (28 laboratories in 18 countries), WNV detection capacity was highest (48 laboratories in 32 countries). Twenty-five laboratories were able to test the whole EQA panel, of which only 11 provided completely correct results. The highest scores were observed for WNV and TOSV (92%), followed by TBEV (86%) and USUV (75%).ConclusionWe observed wide variety in extraction methods and RT-PCR tests, showing a profound absence of standardisation across European laboratories. Overall, the results were not satisfactory; capacity and capability need to be improved in 40 laboratories.


Subject(s)
Encephalitis Viruses, Tick-Borne/genetics , Flavivirus/genetics , Laboratories/standards , Molecular Diagnostic Techniques/standards , Quality Assurance, Health Care/standards , Sandfly fever Naples virus/genetics , Encephalitis Viruses, Tick-Borne/isolation & purification , Encephalitis, Tick-Borne/diagnosis , Flavivirus/isolation & purification , Flavivirus Infections/diagnosis , Humans , Phlebotomus Fever/diagnosis , Quality Control , Sandfly fever Naples virus/isolation & purification , West Nile Fever/virology , West Nile virus/immunology
11.
Parasit Vectors ; 12(1): 265, 2019 May 27.
Article in English | MEDLINE | ID: mdl-31133059

ABSTRACT

Arboviruses represent a significant burden to public health and local economies due to their ability to cause unpredictable and widespread epidemics. To maximize early detection of arbovirus emergence in non-endemic areas, surveillance efforts should target areas where circulation is most likely. However, identifying such hotspots of potential emergence is a major challenge. The ecological conditions leading to arbovirus outbreaks are shaped by complex interactions between the virus, its vertebrate hosts, arthropod vector, and abiotic environment that are often poorly understood. Here, we systematically review the ecological risk factors associated with the circulation of six arboviruses that are of considerable concern to northwestern Europe. These include three mosquito-borne viruses (Japanese encephalitis virus, West Nile virus, Rift Valley fever virus) and three tick-borne viruses (Crimean-Congo hemorrhagic fever virus, tick-borne encephalitis virus, and louping-ill virus). We consider both intrinsic (e.g. vector and reservoir host competence) and extrinsic (e.g. temperature, precipitation, host densities, land use) risk factors, identify current knowledge gaps, and discuss future directions. Our systematic review provides baseline information for the identification of regions and habitats that have suitable ecological conditions for endemic circulation, and therefore may be used to target early warning surveillance programs aimed at detecting multi-virus and/or arbovirus emergence.


Subject(s)
Arbovirus Infections/epidemiology , Arboviruses/isolation & purification , Mosquito Vectors/virology , Animals , Arboviruses/classification , Arthropod Vectors/virology , Disease Vectors , Encephalitis Virus, Japanese/isolation & purification , Europe , Humans , Rift Valley fever virus/isolation & purification , Risk Factors , West Nile virus/isolation & purification
12.
Euro Surveill ; 23(19)2018 05.
Article in English | MEDLINE | ID: mdl-29766839

ABSTRACT

From December 2013 to March 2016, West Africa experienced the largest Ebola virus (EBOV) outbreak to date, leading to a European-wide activation of laboratory preparedness and response. At the end of the outbreak, laboratories associated with the two European preparedness networks of expert laboratories EMERGE JA and EVD-LabNet were invited to participate in an assessment of the response of European laboratories to the EBOV outbreak, to identify learning points and training needs to strengthen future outbreak responses. Response aspects assessed included diagnostics, biorisk management and quality assurance. The overall coverage of EBOV diagnostics in the European Union/European Economic Area (EU/EEA) was found to be adequate although some points for quality improvement were identified. These included the need for relevant International Organization for Standardization (ISO) accreditation, the provision of EBOV external quality assessments (EQA) in periods where there is no emergency, facilitating access to controls and knowledge, biorisk management without compromising biosafety and a rapid public health response, and the need for both sustained and contingency funding for preparedness and response activities.


Subject(s)
Containment of Biohazards/standards , Disease Outbreaks/prevention & control , Ebolavirus/isolation & purification , Hemorrhagic Fever, Ebola/diagnosis , Laboratories/standards , Safety/standards , Africa, Western/epidemiology , Europe , Hemorrhagic Fever, Ebola/epidemiology , Hemorrhagic Fever, Ebola/virology , Humans , Laboratories/organization & administration
13.
Ann Clin Transl Neurol ; 5(5): 606-615, 2018 May.
Article in English | MEDLINE | ID: mdl-29761123

ABSTRACT

OBJECTIVE: Previous studies have associated Guillain-Barré syndrome (GBS) with Zika virus (ZIKV) outbreaks in South America and Oceania. In Asia, ZIKV is known to circulate widely, but the association with Guillain-Barré syndrome is unclear. We investigated whether endemic ZIKV infection is associated with the development of GBS. METHODS: A prospective study was conducted from 2011 to 2015 in Bangladesh. A total of 418 patients and 418 healthy family controls were included in the study. Patients were diagnosed with GBS prior to inclusion according to established criteria. Detailed information on the epidemiology, clinical presentation, electrophysiology, diagnosis, disease severity, and clinical course were obtained during a follow-up of 1 year using a predefined protocol. RESULTS: ZIKV-neutralizing antibodies were detected in our study from 2013 onwards. The prevalence of ZIKV-neutralizing antibodies was not significantly higher in patients with GBS compared to healthy controls (OR 2.23, P = 0.14, 95% CI 0.77-6.53). Serological evidence for prior ZIKV infection in patients with GBS was associated with more frequent cranial, sensory, and autonomic nerve involvement compared to GBS patients with Campylobacter jejuni, the predominant preceding infection in GBS worldwide. Nerve-conduction studies revealed that ZIKV antibodies were associated with a demyelinating subtype of GBS, while C. jejuni infections were related to an axonal subtype. INTERPRETATION: No significant association was found between ZIKV infection and GBS in Bangladesh, but GBS following ZIKV infection was characterized by a distinct clinical and electrophysiological subtype compared to C. jejuni infection. These findings indicate that ZIKV may precede a specific GBS subtype but the risk is low.

14.
Euro Surveill ; 22(36)2017 09 07.
Article in English | MEDLINE | ID: mdl-28920574

ABSTRACT

With international travel, Zika virus (ZIKV) is introduced to Europe regularly. A country's ability to robustly detect ZIKV introduction and local transmission is important to minimise the risk for a ZIKV outbreak. Therefore, sufficient expertise and diagnostic capacity and capability are required in European laboratories. To assess the capacity, quality, operational specifics (guidelines and algorithms), technical and interpretation issues and other possible difficulties that were related to ZIKV diagnostics in European countries, a questionnaire was conducted among national reference laboratories in 30 countries in the European Union/European Economic Area (EU/EEA) in May 2016. While the coverage and capacity of ZIKV diagnostics in the EU/EEA national reference laboratories were found to be adequate, the assessment of the quality and needs indicated several crucial points of improvement that will need support at national and EU/EEA level to improve ZIKV preparedness, response and EU/EEA ZIKV surveillance activities.


Subject(s)
Disease Outbreaks/prevention & control , Laboratories/standards , Quality Assurance, Health Care/methods , Zika Virus Infection/diagnosis , Zika Virus/isolation & purification , Communicable Diseases, Emerging , Europe/epidemiology , Humans , Population Surveillance , Zika Virus Infection/epidemiology
15.
J Clin Microbiol ; 55(11): 3219-3226, 2017 11.
Article in English | MEDLINE | ID: mdl-28835479

ABSTRACT

Zika virus (ZIKV) infections are a significant public health concern. A strong capability for ZIKV detection is an absolute requirement for adequate preparedness and response strategies and individual patient care. The objective of this study was to assess and improve the capability of European expert laboratories for molecular testing for ZIKV through an external quality assessment (EQA) scheme. Laboratories were provided a panel of 12 samples which included negative samples, samples containing African- or Asian-lineage ZIKV at various concentrations (103 to 109 copies/ml), and samples containing dengue virus, yellow fever virus, or chikungunya virus. The results were analyzed on the basis of the outcomes of testing for the samples and the extraction and detection method used. Samples with a ZIKV RNA status scored correctly by >50% of the laboratories were designated the core sample. A total of 85 panel outcomes were submitted by 50 laboratories in 31 countries. The results designated all samples as core samples. Thirty-three percent (28/85) of the panel outcomes identified all samples. Analysis at the laboratory level showed that only 40% of the laboratories (20/50), representing 45% of the countries, scored sufficiently; i.e., they had at least one test operational that scored all core samples correctly. There is a need for improvement of the molecular detection of ZIKV in 60% of the participating laboratories. While the specificity of the tests was more robust, the results of the EQA showed large variation in test sensitivity. Improvements should focus on both nucleic acid extraction and ZIKV detection methods.


Subject(s)
Laboratories , Laboratory Proficiency Testing , Zika Virus Infection/diagnosis , Zika Virus/isolation & purification , Europe , Humans , Sensitivity and Specificity
16.
J Gen Virol ; 98(6): 1274-1281, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28612701

ABSTRACT

Over the last decade, an increasing proportion of circulating human influenza A(H3N2) viruses exhibited haemagglutination activity that was sensitive to neuraminidase inhibitors. This change in haemagglutination as compared to older circulating A(H3N2) viruses prompted an investigation of the underlying molecular basis. Recent human influenza A(H3N2) viruses were found to agglutinate turkey erythrocytes in a manner that could be blocked with either oseltamivir or neuraminidase-specific antisera, indicating that agglutination was driven by neuraminidase, with a low or negligible contribution of haemagglutinin. Using representative virus recombinants it was shown that the haemagglutinin of a recent A(H3N2) virus indeed had decreased activity to agglutinate turkey erythrocytes, while its neuraminidase displayed increased haemagglutinating activity. Viruses with chimeric and mutant neuraminidases were used to identify the amino acid substitution histidine to arginine at position 150 flanking the neuraminidase catalytic site as the determinant of this neuraminidase-mediated haemagglutination. An analysis of publicly available neuraminidase gene sequences showed that viruses with histidine at position 150 were rapidly replaced by viruses with arginine at this position between 2005 and 2008, in agreement with the phenotypic data. As a consequence of neuraminidase-mediated haemagglutination of recent A(H3N2) viruses and poor haemagglutination via haemagglutinin, haemagglutination inhibition assays with A(H3N2) antisera are no longer useful to characterize the antigenic properties of the haemagglutinin of these viruses for vaccine strain selection purposes. Continuous monitoring of the evolution of these viruses and potential consequences for vaccine strain selection remains important.


Subject(s)
Arginine/metabolism , Hemagglutination , Influenza A Virus, H3N2 Subtype/enzymology , Neuraminidase/metabolism , Animals , Arginine/genetics , Catalytic Domain , DNA Mutational Analysis , Erythrocytes , Evolution, Molecular , Hemagglutination Inhibition Tests , Humans , Influenza A Virus, H3N2 Subtype/genetics , Influenza, Human/virology , Neuraminidase/genetics , Recombination, Genetic , Reverse Genetics , Turkeys
17.
J Clin Virol ; 92: 25-31, 2017 07.
Article in English | MEDLINE | ID: mdl-28505571

ABSTRACT

BACKGROUND: Diagnostic requests for both Zika virus (ZIKV) and dengue virus (DENV) infections in returning travelers have significantly increased during the recent ZIKV outbreak in the Americás. These flaviviruses have overlapping clinical syndromes and geographical distribution, but diagnostic differentiation is important because of different clinical consequences. As flaviviruses are known to have a short viremic period, diagnostics often rely on serological methods, which are challenging due to extensive cross-reactive antibodies. OBJECTIVE: To re-evaluate the performance of DENV serological assays in laboratory confirmed ZIKV-infected travelers. STUDY DESIGN: The extent of cross-reactivity of the DENV NS1 antigen, IgM and IgG ELISA was analyzed in 152 clinical blood samples collected from 69 qRT-PCR and 24 virus neutralization titer (VNT) confirmed ZIKV-infected travelers. RESULTS: The majority of travelers in the presented cohort returned to the Netherlands from Suriname and presented with symptoms of fever and rash. Twenty-three percent of the female travelers were pregnant. None of the 39 ZIKV RNA positive blood samples were cross-reactive in the DENV NS1 antigen ELISA. The rates of cross-reactivity of the DENV IgM and IgG ELISÁs were 31% and 54%, respectively, after excluding travelers with (potential) previous DENV exposure. CONCLUSIONS: Although the DENV NS1 antigen assay was highly specific in this cohort of laboratory confirmed ZIKV-infected travelers, we demonstrate high percentages of cross-reactivity of DENV IgM and IgG ELISÁs of which diagnostic laboratories should be aware. In addition, the high rate of DENV IgG background of >25% complicates a proper serological diagnosis in this group.


Subject(s)
Antibodies, Viral/blood , Dengue Virus/immunology , Dengue Virus/isolation & purification , Dengue/diagnosis , Travel-Related Illness , Zika Virus Infection/diagnosis , Zika Virus/immunology , Adult , Cohort Studies , Cross Reactions , Dengue/virology , Dengue Virus/genetics , Enzyme-Linked Immunosorbent Assay/methods , Female , Humans , Immunoglobulin G/blood , Immunoglobulin M/blood , Male , Middle Aged , Netherlands , RNA, Viral/blood , Real-Time Polymerase Chain Reaction , Serologic Tests , Suriname , Viral Nonstructural Proteins/blood , Viral Nonstructural Proteins/immunology , Zika Virus/genetics , Zika Virus/isolation & purification , Zika Virus Infection/virology
19.
Euro Surveill ; 21(23)2016 Jun 09.
Article in English | MEDLINE | ID: mdl-27313200

ABSTRACT

We report the longitudinal follow-up of Zika virus (ZIKV) RNA in semen of a traveller who developed ZIKV disease after return to the Netherlands from Barbados, March 2016. Persistence of ZIKV RNA in blood, urine, saliva and semen was followed until the loads reached undetectable levels. RNA levels were higher in semen than in other sample types and declined to undetectable level at day 62 post onset of symptoms.


Subject(s)
RNA/analysis , Semen Analysis/methods , Semen/chemistry , Travel , Zika Virus Infection/virology , Zika Virus/isolation & purification , Barbados , Disease Progression , Follow-Up Studies , Humans , Longitudinal Studies , Male , Middle Aged , Netherlands , Viral Load , Zika Virus/genetics , Zika Virus Infection/diagnosis
20.
Euro surveill ; 21(23): 4, June 9, 2016. graf
Article in English | LILACS, MedCarib | ID: biblio-906913

ABSTRACT

We report the longitudinal follow-up of Zika virus (ZIKV) RNA in semen of a traveller who developed ZIKV disease after return to the Netherlands from Barbados, March 2016. Persistence of ZIKV RNA in blood, urine, saliva and semen was followed until the loads reached undetectable levels. RNA levels were higher in semen than in other sample types and declined to undetectable level at day 62 post onset of symptoms...(AU)


Subject(s)
Humans , Male , Middle Aged , Serology/statistics & numerical data , Virology/statistics & numerical data , Disease Transmission, Infectious , Zika Virus Infection/blood , Zika Virus Infection/transmission , Barbados/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...