Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Int Oral Health ; 7(Suppl 1): 68-71, 2015.
Article in English | MEDLINE | ID: mdl-26225109

ABSTRACT

Rhino-orbito-cerebral mucormycosis is an uncommon aggressive life-threatening opportunistic fungal infection that affects mainly the immunocompromised population with mortality rate up to 50%. Due to its aggressive nature, early detection and prompt management are of great importance for a good prognosis. Our report describes a fatal outcome of a case of rhino-orbito-cerebral mucormycosis following tooth extraction in an uncontrolled non-insulin-dependent diabetes mellitus patient after 14 days of admission.

2.
Saudi Med J ; 36(7): 865-8, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26108594

ABSTRACT

Mucormycosis is an uncommon acute invasive fungal infection that affects immunocompromised patients. It progresses rapidly and has poor prognosis if diagnosed late. Early detection, control of the underlying condition with aggressive surgical debridement, administration of systemic and local antifungal therapies, hyperbaric oxygen as adjunctive treatment improves prognosis and survivability.


Subject(s)
Antifungal Agents/therapeutic use , Eye Infections, Fungal/therapy , Mucormycosis/therapy , Nose Diseases/therapy , Antifungal Agents/administration & dosage , Eye Infections, Fungal/drug therapy , Female , Humans , Hyperbaric Oxygenation , Middle Aged , Mucormycosis/drug therapy , Nose Diseases/drug therapy
3.
Acta Pharm ; 64(4): 433-46, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25531784

ABSTRACT

High performance liquid chromatography (HPLC) and second-order derivative spectrophotometry have been used for simultaneous determination of pravastatin (PS) and fenofibrate (FF) in pharmaceutical formulations. HPLC separation was performed on a phenyl HYPERSIL C18 column (125 mm × 4.6 mm i.d., 5 µm particle diameter) in the isocratic mode using a mobile phase acetonitrile/0.1 % diethyl amine (50:50, V/V, pH 4.5) pumped at a flow rate of 1.0 mL min-1. Measurement was made at 240 nm. Both drugs were well resolved on the stationary phase, with retention times of 2.15 and 5.79 min for PS and FF, respectively. Calibration curves were linear (R = 0.999 for PS and 0.996 for FF) in the concentration range of 5-50 and 20-200 µg mL-1 for PS and FF, respectively. Pravastatin and fenofibrate were quantitated in combined preparations also using the second-order derivative response at 237.6 and 295.1 nm for PS and FF, respectively. Calibration curves were linear, with the correlation coefficient R = 0.999 for pravastatin and fenofibrate, in the concentration range of 5-20 and 3-20 µg mL-1 for PS and FF, respectively. Both methods were fully validated and compared, the results confirmed that they were highly suitable for their intended purpose.


Subject(s)
Chromatography, High Pressure Liquid/methods , Fenofibrate/analysis , Pravastatin/analysis , Spectrophotometry, Ultraviolet/methods , Calibration , Drug Combinations , Fenofibrate/administration & dosage , Pravastatin/administration & dosage
4.
Chem Cent J ; 5: 30, 2011 Jun 14.
Article in English | MEDLINE | ID: mdl-21672253

ABSTRACT

A simple, sensitive and accurate stability-indicating HPLC method has been developed and validated for determination of varenicline (VRC) in its bulk form and pharmaceutical tablets. Chromatographic separation was achieved on a Zorbax Eclipse XDB-C8 column (150 mm × 4.6 mm i.d., particle size 5 µm, maintained at ambient temperature) by a mobile phase consisted of acetonitrile and 50 mM potassium dihydrogen phosphate buffer (10:90, v/v) with apparent pH of 3.5 ± 0.1 and a flow rate of 1.0 ml/min. The detection wavelength was set at 235 nm. VRC was subjected to different accelerated stress conditions. The degradation products, when any, were well resolved from the pure drug with significantly different retention time values. The method was linear (r = 0.9998) at a concentration range of 2 - 14 µg/ml. The limit of detection and limit of quantitation were 0.38 and 1.11 µg/ml, respectively. The intra- and inter-assay precisions were satisfactory; the relative standard deviations did not exceed 2%. The accuracy of the method was proved; the mean recovery of VRC was 100.10 ± 1.08%. The proposed method has high throughput as the analysis involved short run-time (~ 6 min). The method met the ICH/FDA regulatory requirements. The proposed method was successfully applied for the determination of VRC in bulk and tablets with acceptable accuracy and precisions; the label claim percentages were 99.65 ± 0.32%. The results demonstrated that the method would have a great value when applied in quality control and stability studies for VRC.

SELECTION OF CITATIONS
SEARCH DETAIL
...