Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Cureus ; 16(6): e62810, 2024 Jun.
Article in English | MEDLINE | ID: mdl-39040759

ABSTRACT

Hip fractures are common in patients with poor bone quality and are seen to affect the elderly and frail population. We report a case of implant failure after fixing an unstable intertrochanteric fracture with a dynamic hip screw (DHS). The patient presented with a DHS that had migrated into the pelvis approximately six months after surgery. Plain radiographs showed migration of the DHS through the acetabulum and into the pelvis. Migration of DHS into the pelvis is an extremely rare complication and has only been reported a few times. A 71-year-old man presented with a fall and confusion. The patient reported having a fall but could not recall the exact events. Past medical history included Alzheimer's dementia, osteoporosis, left total hip replacement, right DHS, peripheral neuropathy, and recurrent falls. He had undergone reduction and fixation of a right intertrochanteric fracture with DHS implant via direct lateral approach six months before hospital admission. On examination, he had right-sided hip pain and was unable to straighten leg raise. His abdomen was soft and non-tender, with no distension or palpable masses. Neurovascular status was normal, and no signs of infection were detected. On the anteroposterior radiograph, the implant seemed to have migrated through the acetabulum and into the abdomen. A CT of the abdomen and pelvis was performed to identify any visceral injuries (negative) and for surgical planning. The patient underwent a midline laparotomy to remove the implant. Although the exact reason for the implant failure is unknown, the migration of an unbroken hip screw into the abdomen and pelvis requiring laparotomy has not been reported in literature.

2.
Saudi Dent J ; 36(5): 698-707, 2024 May.
Article in English | MEDLINE | ID: mdl-38766281

ABSTRACT

Albumin is the most abundant protein in human serum and a specific amount of albumin also can be found in the saliva. It has several physiological functions such as blood colloidal osmotic pressure, antioxidant activity, binding and transporting of endogenous and exogenous substrates. We conducted an electronic search across several databases such as PubMed, Scopus, Cochrane, Embase and Science Direct using the relevant MeSH terms and keywords like "albumin", "serum albumin", "salivary albumin", "oral health" "dental caries" and "epidemiology". Only the epidemiological studies published between 2010 and 2023 were included. After the application of the inclusion criteria, a total of 51 studied were included in this narrative review. Serum and salivary albumin tests have been used in various aspects of oral health as a diagnostic and prognostic factor. Some of the results point out to a pattern of association while some of them are inconclusive and even contradictory. This narrative review discusses the role, significance and impact of albumin in epidemiological oral health related studies including the categories of periodontal health and disease, dental caries, oral function and hypofunction, nutrition and malnutrition, tooth loss and its treatment, diabetes and cancer. In addition, it offers a short manual for the researchers on when, where and how to use albumin tests in planning their study designs whether investigating an association or measure them as a covariate.

3.
J Funct Biomater ; 15(1)2023 Dec 30.
Article in English | MEDLINE | ID: mdl-38248682

ABSTRACT

Biomimetic dental implants are regarded as one of the recent clinical advancements in implant surface modification. Coatings with varying thicknesses and roughness may affect the dental implant surface's chemical inertness, cell adhesion, and antibacterial characteristics. Different surface coatings and mechanical surface changes have been studied to improve osseointegration and decrease peri-implantitis. The surface medication increases surface energy, leading to enhanced cell proliferation and growth factors, and, consequently, to a rise in the osseointegration process. This review provides a comprehensive update on the numerous biomimetic coatings used to improve the surface characteristics of dental implants and their applications in two main categories: coating to improve osseointegration, including the hydroxyapatite layer and nanocomposites, growth factors (BMPs, PDGF, FGF), and extracellular matrix (collagen, elastin, fibronectin, chondroitin sulfate, hyaluronan, and other proteoglycans), and coatings for anti-bacterial performance, covering drug-coated dental implants (antibiotic, statin, and bisphosphonate), antimicrobial peptide coating (GL13K and human beta defensins), polysaccharide antibacterial coatings (natural chitosan and its coupling agents) and metal elements (silver, zinc, and copper).

4.
PLoS One ; 17(9): e0267221, 2022.
Article in English | MEDLINE | ID: mdl-36173938

ABSTRACT

BACKGROUND: Klebsiella species are ubiquitous in nature and can be found in the natural environment and on mucosal surfaces of mammals and it is an important multidrug-resistant pathogen affecting humans and is a major source for hospital acquired infections. The aim of this study is to investigate the prevalence of ESBL enzyme among Klebsiella pneumoniae isolates by phenotypic methods from different hospital wards and detection of ESBL resistance genes such as TEM and SHV in Sulaimani city/ Kurdistan-Iraq. METHODS: Klebsiella pneumoniae isolates were collected from different clinical samples from different hospitals, the isolates were identified by standard technique. Screening of ESBLs was undertaken by using double disk diffusion and standard disk diffusion methods. Real-time PCR was used for genotypic detection of TEM and SHV genes according to the standard protocol. RESULT: Out of 54 Klebsiella pneumoniae isolates; 28 were ESBL positive, The pattern of antimicrobial susceptibility testing showed that the most resistant antibiotic are AMP (100%), AMC (100%) followed by CAZ (83.33%), CTX (75.9%), CPM (74%), ATM (70.37%). Both TEM and SHV genes were detected among 28 (51.85%) ESBL positive by using Real-time PCR method. CONCLUSION: SHV gene was detected in most of the isolates of ESBL producers of Klebsiella pneumoniae.


Subject(s)
Anti-Bacterial Agents , Klebsiella pneumoniae , Animals , Humans , beta-Lactamases/genetics , Genotype , Klebsiella pneumoniae/genetics , Mammals
5.
Acta Orthop Belg ; 80(2): 269-75, 2014 Jun.
Article in English | MEDLINE | ID: mdl-25090802

ABSTRACT

This retrospective study examined the medium term outcome of 305 Titanium Nitride (TiN) Mobile bearing total knee. At ten years after the start of the study, there was a significant improvement (p < 0.0001) in the post-operative knee scores. The ten year survival with revision for any reason as the end point was 95.1% (95% CI 92.4 to 97.8). The ten year survival rate with revision for aseptic loosening as the end point was 99.1% (95% CI 97.8 to 100%). A total of 15 knees (4.9%, overall) required revision. No cases were revised due to sepsis. Based on these results, the surface Titanium Nitride ceramic, mobile-bearing total knee replacement has proved to be a reliable implant at 10 years when used in primary knee replacement.


Subject(s)
Knee Prosthesis , Titanium , Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee , Female , Humans , Male , Middle Aged , Prosthesis Design , Reoperation , Retrospective Studies , Time Factors , Treatment Outcome
6.
Int Orthop ; 32(4): 547-9, 2008 Aug.
Article in English | MEDLINE | ID: mdl-17410364

ABSTRACT

Distal third tibial fractures are prone to non-union following tibial nail insertion. The purpose of this study was to assess the union of distal third tibial fractures in patients who have undergone intra-medullary (IM) tibial nailing with one versus two distal locking screws. Sixty-five patients who had intramedullary tibial nail fixation were retrospectively analysed. Our results showed that 80% of non-unions in distal third fractures had only one distal locking screw compared to 20% who had two distal locking screws. This is statistically significant (p<0.01). We therefore conclude that two distal locking screws are essential for distal third fractures.


Subject(s)
Fracture Fixation, Intramedullary/methods , Fractures, Ununited/etiology , Tibial Fractures/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Bone Nails , Bone Screws , Female , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome
7.
Prehosp Disaster Med ; 21(5): 340-4, 2006.
Article in English | MEDLINE | ID: mdl-17297905

ABSTRACT

During the morning rush hour on Thursday, 07 July 2005, a series of four bombs exploded, affecting London's public transport system. These terrorist attacks killed 52 people and injured > 700. A major incident was declared, and the Royal London Hospital (RLH) was a primary receiving hospital. A total of 194 patients presented to the RLH. Twenty-seven patients required admission. A total of 11 amputations were performed on eight patients. One patient died intra-operatively. Another patient died on Day 6 due to complications related to a head injury. Coordination is vital to the implementation of the hospital's Major Incident Plan in such an emergency. Subsequent internal reviews of the response of the RLH on 07 July 2005 highlighted problems with communication and documentation, as well as the need for extra staffing. These areas should be improved for the management of future major incidents.


Subject(s)
Emergency Service, Hospital/statistics & numerical data , Explosions , Terrorism , Emergency Service, Hospital/organization & administration , Humans , London , Organizational Case Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...