Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Neurosurg ; : 1-8, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38701528

ABSTRACT

OBJECTIVE: This study was conducted to investigate the impact of antiplatelet administration in the periprocedural period on the occurrence of thromboembolic complications (TECs) in patients undergoing treatment using the Woven EndoBridge (WEB) device for intracranial wide-necked bifurcation aneurysms. The primary objective was to assess whether the use of antiplatelets in the pre- and postprocedural phases reduces the likelihood of developing TECs, considering various covariates. METHODS: A retrospective multicenter observational study was conducted within the WorldWideWEB Consortium and comprised 38 academic centers with endovascular treatment capabilities. Univariable and multivariable logistic regression analyses were performed to determine the association between antiplatelet use and TECs, adjusting for covariates. Missing predictor data were addressed using multiple imputation. RESULTS: The study comprised two cohorts: one addressing general thromboembolic events and consisting of 1412 patients, among whom 103 experienced TECs, and another focusing on symptomatic thromboembolic events and comprising 1395 patients, of whom 50 experienced symptomatic TECs. Preprocedural antiplatelet use was associated with a reduced likelihood of overall TECs (OR 0.32, 95% CI 0.19-0.53, p < 0.001) and symptomatic TECs (OR 0.49, 95% CI 0.25-0.95, p = 0.036), whereas postprocedural antiplatelet use showed no significant association with TECs. The study also revealed additional predictors of TECs, including stent use (overall: OR 4.96, 95% CI 2.38-10.3, p < 0.001; symptomatic: OR 3.24, 95% CI 1.26-8.36, p = 0.015), WEB single-layer sphere (SLS) type (overall: OR 0.18, 95% CI 0.04-0.74, p = 0.017), and posterior circulation aneurysm location (symptomatic: OR 18.43, 95% CI 1.48-230, p = 0.024). CONCLUSIONS: The findings of this study suggest that the preprocedural administration of antiplatelets is associated with a reduced likelihood of TECs in patients undergoing treatment with the WEB device for wide-necked bifurcation aneurysms. However, postprocedural antiplatelet use did not show a significant impact on TEC occurrence.

2.
Neurosurg Rev ; 47(1): 116, 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38483647

ABSTRACT

BACKGROUND: The Woven EndoBridge (WEB) devices have been used for treating wide neck bifurcation aneurysms (WNBAs) with several generational enhancements to improve clinical outcomes. The original device dual-layer (WEB DL) was replaced by a single-layer (WEB SL) device in 2013. This study aimed to compare the effectiveness and safety of these devices in managing intracranial aneurysms. METHODS: A multicenter cohort study was conducted, and data from 1,289 patients with intracranial aneurysms treated with either the WEB SL or WEB DL devices were retrospectively analyzed. Propensity score matching was utilized to balance the baseline characteristics between the two groups. Outcomes assessed included immediate occlusion rate, complete occlusion at last follow-up, retreatment rate, device compaction, and aneurysmal rupture. RESULTS: Before propensity score matching, patients treated with the WEB SL had a significantly higher rate of complete occlusion at the last follow-up and a lower rate of retreatment. After matching, there was no significant difference in immediate occlusion rate, retreatment rate, or device compaction between the WEB SL and DL groups. However, the SL group maintained a higher rate of complete occlusion at the final follow-up. Regression analysis showed that SL was associated with higher rates of complete occlusion (OR: 0.19; CI: 0.04 to 0.8, p = 0.029) and lower rates of retreatment (OR: 0.12; CI: 0 to 4.12, p = 0.23). CONCLUSION: The WEB SL and DL devices demonstrated similar performances in immediate occlusion rates and retreatment requirements for intracranial aneurysms. The SL device showed a higher rate of complete occlusion at the final follow-up.


Subject(s)
Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Treatment Outcome , Intracranial Aneurysm/surgery , Intracranial Aneurysm/etiology , Embolization, Therapeutic/adverse effects , Propensity Score , Retrospective Studies , Cohort Studies , Endovascular Procedures/adverse effects
3.
J Neurointerv Surg ; 2024 Jan 18.
Article in English | MEDLINE | ID: mdl-38238006

ABSTRACT

BACKGROUND: The Woven EndoBridge (WEB) device is frequently used for the treatment of intracranial aneurysms. Postoperative management, including the use of aspirin, varies among clinicians and institutions, but its impact on the outcomes of the WEB has not been thoroughly investigated. METHODS: This was a retrospective, multicenter study involving 30 academic institutions in North America, South America, and Europe. Data from 1492 patients treated with the WEB device were included. Patients were categorized into two groups based on their postoperative use of aspirin (aspirin group: n=1124, non-aspirin group: n=368). Data points included patient demographics, aneurysm characteristics, procedural details, complications, and angiographic and functional outcomes. Propensity score matching (PSM) was applied to balance variables between the two groups. RESULTS: Prior to PSM, the aspirin group exhibited significantly higher rates of modified Rankin scale (mRS) mRS 0-1 and mRS 0-2 (89.8% vs 73.4% and 94.1% vs 79.8%, p<0.001), lower rates of mortality (1.6% vs 8.6%, p<0.001), and higher major compaction rates (13.4% vs 7%, p<0.001). Post-PSM, the aspirin group showed significantly higher rates of retreatment (p=0.026) and major compaction (p=0.037) while maintaining its higher rates of good functional outcomes and lower mortality rates. In the multivariable regression, aspirin was associated with higher rates of mRS 0-1 (OR 2.166; 95% CI 1.16 to 4, p=0.016) and mRS 0-2 (OR 2.817; 95% CI 1.36 to 5.88, p=0.005) and lower rates of mortality (OR 0.228; 95% CI 0.06 to 0.83, p=0.025). However, it was associated with higher rates of retreatment (OR 2.471; 95% CI 1.11 to 5.51, p=0.027). CONCLUSIONS: Aspirin use post-WEB treatment may lead to better functional outcomes and lower mortality but with higher retreatment rates. These insights are crucial for postoperative management after WEB procedures, but further studies are necessary for validation.

4.
J Stroke Cerebrovasc Dis ; 33(1): 107462, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37931483

ABSTRACT

PURPOSE: There is increasing interest in novel prognostic tools and predictive biomarkers to help identify, with more certainty, cerebral cavernous malformations (CCM) susceptible of bleeding if left untreated. We developed explainable quantitative-based machine learning models from magnetic resonance imaging (MRI) in a large CCM cohort to demonstrate the value of artificial intelligence and radiomics in complementing natural history studies for hemorrhage and functional outcome prediction. MATERIALS AND METHODS: One-hundred-eighty-one patients from a prospectively registered cohort of 366 adults with CCM were included. Fluid attenuated inversion recovery (FLAIR) T2-weighted brain images were preprocessed, and CCM and surrounding edema were segmented before radiomic feature computation. Minority class oversampling, dimensionality reduction and feature selection methods were applied. With prospective hemorrhage as primary outcome, machine learning models were built, cross-validated, and compared using clinico-radiologic, radiomic, and combined features. SHapley Additive exPlanations (SHAP) was used for interpretation to determine the radiomic features with most contribution to hemorrhage prediction. RESULTS: The highest performances in hemorrhage predictions on the test set were combining radiomic and clinico-radiological features with an area under the curve (AUC) of 83% using linear regression and selected features, and an F1 score of 61% and 85% sensitivity using K-nearest neighbors with principal component analysis (PCA). Multilayer perceptron had the best performance predicting modified Rankin Scale ≥ 2 with an AUC of 74% using PCA derived features. For interpretation of the selected radiomic signature XGBoost model, Shapley additive explanations highlighted 6 radiomic features contributing the most to hemorrhage prediction. CONCLUSION: Quantitative image-based modeling using machine learning has the potential to highlight novel imaging biomarkers that predict hemorrhagic and functional outcomes, ensuring more precise and personalized care for CCM patients.


Subject(s)
Artificial Intelligence , Hemangioma, Cavernous, Central Nervous System , Adult , Humans , Prospective Studies , Hemangioma, Cavernous, Central Nervous System/complications , Hemangioma, Cavernous, Central Nervous System/diagnostic imaging , Magnetic Resonance Imaging/methods , Machine Learning , Biomarkers , Hemorrhage , Retrospective Studies
5.
World Neurosurg X ; 19: 100208, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37213688

ABSTRACT

Background: Little research has focused on the performance of mechanical thrombectomy (MT) in carotid terminus occlusions (CTOs). Therefore, the best first-line thrombectomy strategy for CTOs remains unclear. Purpose: To compare the safety and efficacy outcomes of three first-line thrombectomy techniques in CTOs. Methods: A systematic literature search was conducted in Ovid MEDLINE, Ovid Embase, Scopus, Web of Science, and Cochrane Central Register of Clinical Trials databases. Studies providing safety and efficacy outcomes for endovascular treatment of CTOs were included. Data regarding successful recanalization, functional independence, symptomatic intracranial hemorrhage (sICH), and first pass efficacy (FPE) were extracted from the included studies. A random-effects model was used to calculate prevalence rates and their corresponding 95% confidence intervals (CI), and subgroup analyses were performed to assess the impact of the initial MT technique on safety and efficacy outcomes. Results: Six studies with 524 patients were included. The overall successful recanalization rate was 85.84% (95% CI = 77.96-94.52), and subgroup analysis did not show a significant difference among the three first-line MT techniques. Overall rates of functional independence and FPE were 39.73% (95% CI = 32.95-47.89) and 32.09% (95% CI = 22.93-44.92), respectively. The combined stent retriever (SR) and aspiration (ASP) technique achieved significantly higher first-pass efficacy rates compared to SR or ASP alone. The overall sICH rate was 9.89% (95% CI = 4.88-20.07), and subgroup analysis did not demonstrate a significant difference across groups. The sICH rates of SR, ASP, and SR + ASP were 8.49% (95% CI = 1.76-40.93), 6.8% (95% CI = 4.59-10.09), and 7.12% (95% CI = 0.27-100), respectively. Conclusions: Our results support that MT is highly effective for CTOs with functional independence rates of 39%. Additionally, in our meta-analysis, the SR + ASP technique was associated significantly greater rates of FPE compared to SR or ASP alone, without an increase in sICH rates. Prospective, large-scale studies are necessary to determine the optimal first-line MT technique in the endovascular treatment of CTOs.

SELECTION OF CITATIONS
SEARCH DETAIL
...