Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Oral Investig ; 27(6): 3245-3259, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36947263

ABSTRACT

OBJECTIVE: This single center parallel, randomized controlled trial aimed to determine the propensity of microbial adherence on vacuum-formed retainers (VFRs) with different surface roughness imprints. MATERIALS AND METHODS: Thirty-six patients debonded from fixed appliances at a teaching institution were allocated by block randomization stratified for gender to three groups [VFRs fabricated on conventional, fused deposition modeling (FDM) or stereolithography apparatus (SLA) working models]. Participants wore the VFRs for three months full-time followed by three months part-time. VFRs were collected after each follow-up for Streptococcus and yeast counts. Surface roughness was measured indirectly on the working models using a 3D optical surface texture analyzer. Blinding was not feasible due to appliance appearance. The trial was registered [NCT03844425 ( ClinicalTrials.gov )] and funded by the Universiti Malaya Dental Postgraduate Research Grant (DPRG/14/19). RESULTS: Thirty participants (eleven conventional, ten FDM, and nine SLA) were analyzed after six dropped out. No harms were reported. Microbial counts between the groups were not significantly different. There were more microbes in the lower VFRs than upper VFRs (total count: p<0.05; effect size, 0.5 during full-time wear and 0.4 during part-time wear). SLA had significantly (p<0.05) smoother surface than FDM (effect size, 0.3) and conventional models (effect size, 0.5). Microbial adherence was not associated with working model surface roughness. CONCLUSION: Microbial adherence on VFRs was not influenced by degree of surface roughness imprints from working models. CLINICAL RELEVANCE: 3D printed models can be used to make VFRs. Lower VFRs tended to accumulate oral microbes, potentially increasing the oral health risk in the lower arch.


Subject(s)
Orthodontic Appliance Design , Orthodontic Retainers , Humans , Vacuum , Orthodontic Appliances, Fixed , Printing, Three-Dimensional
2.
Eur J Dent Educ ; 27(3): 419-427, 2023 Aug.
Article in English | MEDLINE | ID: mdl-35579042

ABSTRACT

OBJECTIVE: To explore students' perception on the implementation of flipped classroom (FC) combined with formative assessment during the undergraduate teaching of orthodontic wire-bending skills. METHODS: Third-year undergraduate dental students were taught wire-bending skills via FC teaching method using a series of pre-recorded online video demonstrations. As part of the formative assessment, the students were given the results and assessment rubrics of their prior wire-bending assessment before every subsequent session. Purposive sampling method for focus group discussion was used to recruit eight students comprising four high achievers and four low achievers. Strengths, weaknesses and suggestions for improvement of the FC with formative assessment were explored. Data were transcribed and thematically analysed. RESULTS: Students perceived that FC allowed for a more convenient and flexible learning experience with personalised learning and improved in-class teaching efficiency. The pre-recorded online videos were useful to aid in teaching wire-bending skills but lacked three-dimensional representation of the wire-bending process. Students suggested better standardisation of instructions and access to the marking rubric before and after assessment. CONCLUSIONS: FC teaching with continuous formative assessment and constructive feedback as a form of personalised learning was viewed favourably by students. The implementation of periodic individual feedback can further enhance their learning experience.


Subject(s)
Education, Dental , Learning , Humans , Focus Groups , Students , Perception , Problem-Based Learning
3.
J Dent Educ ; 86(11): 1477-1487, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35650663

ABSTRACT

OBJECTIVE: This study aimed to explore students' perceptions of flipped classroom (FC) compared to live demonstration (LD) in transferring skills of fabricating orthodontic wire components for orthodontic removable appliances. METHODS: Forty third-year undergraduate dental students were randomly assigned to two groups: FC (n = 20) and LD (n = 20). Students in group FC attended FC, while students in group LD attended LD. Both groups underwent a series of standardized teaching sessions to acquire skills in fabricating six types of orthodontic wire components. Eight students (four high achievers and four low achievers) from each group were randomly selected to attend separate focus group discussion (FGD) sessions. Students' perceptions on the strengths, weaknesses, and suggestions for improvement on each teaching method were explored. Audio and video recordings of FGD were transcribed and thematically analyzed using NVivo version 12 software. RESULTS: Promoting personalized learning, improvement in teaching efficacy, inaccuracy of three-dimensional demonstration from online video, and lack of standardization among instructors and video demonstration were among the themes identified. Similarly, lack of standardization among instructors was one of the themes identified for LD, in addition to other themes such as enabling immediate clarification and vantage point affected by seating arrangement and class size. CONCLUSIONS: In conclusion, FC outperformed LD in fostering personalized learning and improving the efficacy of physical class time. LD was more advantageous than FC in allowing immediate question and answer. However, seating arrangement and class size affected LD in contrast to FC.


Subject(s)
Learning , Orthodontic Wires , Humans , Curriculum , Focus Groups , Perception , Problem-Based Learning , Students , Teaching
4.
PLoS One ; 16(7): e0254478, 2021.
Article in English | MEDLINE | ID: mdl-34243187

ABSTRACT

Flipped classroom may overcome weaknesses of live demonstration in teaching orthodontic wire-bending. This study aims to compare the effectiveness between flipped classroom and live demonstration in transferring skills for fabricating Adams clasp. Forty third-year undergraduate dental students were assigned to two groups. The students in group LD (n = 20) attended a live demonstration while students in group FC (n = 20) attended a flipped classroom. Both groups were taught on skills to fabricate Adams clasp in a standardised way. Each student from both groups were asked to submit an Adams clasp for a blinded quality assessment by two trained and calibrated assessors using a 18-item rubric, followed by validated students' satisfaction questionnaires to evaluate their perceived satisfaction on the teaching method received. A crossover study was then conducted three weeks later where LD attended a flipped classroom while FC attended a live demonstration. Students' satisfaction questionnaires were again collected from each student for blinded analysis. Mean scores for the quality of Adams clasp were 9.775 and 9.125 for LD and FC, respectively. No significant difference was detected between the two groups. Statistically significant association was found for one statement on the questionnaire, "I found the classroom arrangements conducive for the wire-bending activity" (p = 0.010). No significant differences were found between the two groups for other statements (p > 0.05). In conclusion, within the limitations of the study, flipped classroom is equally effective as conventional live demonstration in transferring orthodontic wire-bending skills for fabrication of Adams clasp. However, students perceived the classroom arrangements during the flipped classroom significantly more conducive for teaching orthodontic wire-bending.


Subject(s)
Orthodontic Wires , Cross-Over Studies , Female , Humans , Male , Problem-Based Learning/methods , Surveys and Questionnaires
5.
BMC Med Educ ; 21(1): 326, 2021 Jun 07.
Article in English | MEDLINE | ID: mdl-34098931

ABSTRACT

BACKGROUND: Wire-bending skills is commonly taught through live demonstrations (LD) though flipped classroom (FC) method has gained popularity. Continuous formative assessment promotes personalised learning via closely monitored progress, with the identification of students' strengths and weaknesses. This study aims to evaluate the effects of LD and FC teaching methods, supplemented with continuous formative assessment, on dental students' learning of wire-bending skills for six types of removable orthodontic appliance components. A deeper understanding of the relative effectiveness between LD and FC teaching methods can help identify the most appropriate method to achieve student learning objectives, which is especially important given the current Covid-19 pandemic. METHODS: Forty third-year undergraduate dental students were randomly assigned into FC (n = 20) or LD (n = 20) cohort. Each student attended six teaching sessions, each to teach students' competency in fabricating one type of wire component, for a total competency in fabricating six wire components over the course of six teaching sessions. Either LD or FC teaching methods were used. After each session, wire assignments had to be submitted. Wire assignments were then evaluated using a blinded wire-bending assessment protocol. As part of their formative assessment, the assessment results were distributed to students, lecturers, and technicians before the next session. After the first session (T0) and at the end of all six sessions (T1), students completed a self-reported questionnaire. RESULTS: The mean wire-bending scores for FC were significantly higher than LD for two of the six assignments, namely the Adams clasp (p < 0.01) and Z-spring (p = 0.03). Scores for both LD and FC increased significantly over time, which may be attributed to formative assessment. There was no statistically significant correlation between wire-bending scores and video usage. Students were satisfied with both teaching methods, according to T0 and T1 questionnaires. CONCLUSIONS: Both LD and FC are equally effective in transferring practical orthodontic wire-bending skills and well-received by students. Continuous formative assessment may have enhanced students' learning of orthodontic wire-bending skills. Further studies with control group are recommended to investigate the effect of formative assessment on teaching practical dental skills.


Subject(s)
COVID-19 , Students, Dental , Educational Measurement , Humans , Orthodontic Wires , Pandemics , Problem-Based Learning , SARS-CoV-2 , Teaching
6.
Eur J Orthod ; 41(4): 370-380, 2019 08 08.
Article in English | MEDLINE | ID: mdl-30321319

ABSTRACT

OBJECTIVES: The aim of this study was to compare vacuum-formed thermoplastic retainers (VFRs) constructed on stone models (VFR-CV) and those constructed on three-dimensional (3D) printed models (VFR-3D) based on patients' perspective and post-treatment stability. STUDY DESIGN: The research was designed as a crossover, randomized control trial. MATERIALS AND METHODS: Subjects comprised patients receiving fixed appliances at a teaching institution and indicated for VFRs. Post-treatment stone models were scanned with a structured-light scanner. A fused deposition modelling machine was used to construct acrylonitrile-butadiene-styrene (ABS)-based replicas from the 3D scanned images. VFRs were fabricated on the original stone and printed models. Analysis comprised independent t-tests and repeated measures analysis of variance. RANDOMIZATION: Subjects were allocated to two groups using Latin squares methods and simple randomization. A week after debond, subjects received either VFR-CV first (group A) or VFR-3D first (group B) for 3 months, then the interventions were crossed over for another 3 months. BLINDING: In this single-blinded study, subjects were assigned a blinding code for data entry; data were analysed by a third party. OUTCOME MEASURES: The primary outcome measured was oral health-related quality of life (OHRQoL) based on Oral Health Impact Profile-14 (OHIP-14). Secondary outcome was post-treatment stability measured using Little's Irregularity Index (LII). RESULTS: A total of 30 subjects (15 in each group) were recruited but 3 dropped out. Analysis included 13 subjects from group A and 14 subjects from group B. Group A showed an increase in LII (P < 0.05) after wearing VFR-CV and VFR-3D, whereas group B had no significant increase in LII after wearing both VFRs. Both groups reported significant improvement in OHRQoL after the first intervention but no significant differences after the second intervention. LII changes and OHIP-14 scores at T2 and T3 between groups, and overall between the retainers were not significantly different. No harm was reported during the study. CONCLUSION: VFRs made on ABS-based 3D printed models showed no differences in terms of patients' OHRQoL and stability compared with conventionally made retainers. REGISTRATION: NCT02866617 (ClinicalTrials.gov).


Subject(s)
Malocclusion , Orthodontic Retainers , Humans , Orthodontic Appliance Design , Orthodontics, Corrective , Printing, Three-Dimensional , Quality of Life
SELECTION OF CITATIONS
SEARCH DETAIL
...