1.
Phys Med Biol ; 61(17): 6413-29, 2016 09 07.
Article in English | MEDLINE | ID: mdl-27499356

ABSTRACT

Small diamond detectors are useful for the dosimetry of high-energy proton beams. However, linear energy transfer (LET) dependence has been observed in the literature with such solid state detectors. A novel synthetic diamond detector has recently become commercially available from the manufacturer PTW-Freiburg (PTW microDiamond type 60019). This study was designed to thoroughly characterize four microDiamond detectors in clinical proton beams, in order to investigate their response and their reproducibility in high LET regions. Very good dosimetric characteristics were observed for two of them, with good stability of their response (deviation less than 0.4% after a pre-irradiation dose of approximately 12 Gy), good repeatability (coefficient of variation of 0.06%) and a sensitivity of approximately 0.85 nC Gy(-1). A negligible dose rate dependence was also observed for these two microDiamonds with a deviation of the sensitivity less than 0.7% with respect to the one measured at the reference dose rate of 2.17 Gy min(-1), in the investigated dose rate range from 1.01 Gy min(-1) to 5.52 Gy min(-1). Lateral dose profile measurements showed the high spatial resolution of the microDiamond oriented with its stem perpendicular to the beam axis and with its small sensitive thickness of about 1 µm in the scanning profile direction. Finally, no significant LET dependence was found with these two diamond dosimeters in comparison to a reference ionization chamber (model IBA PPC05). These good results were in accordance to the literature. However, this study showed also a non reproducibility between the devices in terms of stability, sensitivity and LET dependence, since the two other microDiamonds characterized in this work showed different dosimetric characteristics making them not suitable for proton beam dosimetry with a maximum difference of the peak-to-plateau ratio of 6.7% relative to the reference ionization chamber in a clinical 138 MeV proton beam.


Subject(s)
Proton Therapy/methods , Radiation Dosimeters/standards , Diamond/chemistry , Diamond/radiation effects , Linear Energy Transfer , Proton Therapy/instrumentation , Proton Therapy/standards , Radiometry/instrumentation , Radiometry/methods
2.
Phys Med Biol ; 58(21): 7647-60, 2013 Nov 07.
Article in English | MEDLINE | ID: mdl-24113353

ABSTRACT

Recent developments of new therapy techniques using small photon beams, such as stereotactic radiotherapy, require suitable detectors to determine the delivered dose with a high accuracy. The dosimeter has to be as close as possible to tissue equivalence and to exhibit a small detection volume compared to the size of the irradiation field, because of the lack of lateral electronic equilibrium in small beam. Characteristics of single crystal diamond (tissue equivalent material Z = 6, high density) make it an ideal candidate to fulfil most of small beam dosimetry requirements. A commercially available Element Six electronic grade synthetic diamond was used to develop a single crystal diamond dosimeter (SCDDo) with a small detection volume (0.165 mm(3)). Long term stability was studied by irradiating the SCDDo in a (60)Co beam over 14 h. A good stability (deviation less than ± 0.1%) was observed. Repeatability, dose linearity, dose rate dependence and energy dependence were studied in a 10 × 10 cm(2) beam produced by a Varian Clinac 2100 C linear accelerator. SCDDo lateral dose profile, depth dose curve and output factor (OF) measurements were performed for small photon beams with a micro multileaf collimator m3 (BrainLab) attached to the linac. This study is focused on the comparison of SCDDo measurements to those obtained with different commercially available active detectors: an unshielded silicon diode (PTW 60017), a shielded silicon diode (Sun Nuclear EDGE), a PinPoint ionization chamber (PTW 31014) and two natural diamond detectors (PTW 60003). SCDDo presents an excellent spatial resolution for dose profile measurements, due to its small detection volume. Low energy dependence (variation of 1.2% between 6 and 18 MV photon beam) and low dose rate dependence of the SCDDo (variation of 1% between 0.53 and 2.64 Gy min(-1)) are obtained, explaining the good agreement between the SCDDo and the efficient unshielded diode (PTW 60017) in depth dose curve measurements. For field sizes ranging from 0.6 × 0.6 to 10 × 10 cm(2), OFs obtained with the SCDDo are between the OFs measured with the PinPoint ionization chamber and the Sun Nuclear EDGE diode that are known to respectively underestimate and overestimate OF values in small beam, due to the large detection volume of the chamber and the non-water equivalence of both detectors.


Subject(s)
Diamond/chemistry , Radiometry/instrumentation , Photons/therapeutic use , Time Factors , Water
3.
Appl Radiat Isot ; 62(2): 281-5, 2005 Feb.
Article in English | MEDLINE | ID: mdl-15607462

ABSTRACT

Alanine is an amino acid commonly used in ESR dosimetry as a reference detector. The classic approach for the measurement of irradiated samples is to determine the amplitude of the central peak of the first derivative spectrum. It is generally considered that this technique represents the best and most reproducible solution for achieving an accurate proportionality between the concentration of free radicals inside the resonant cavity, characterized by the amplitude, and the dose. It is also accepted that this central peak corresponds to the free radical CH3CHCOO-. The hyperfine structure of this radical in the spectrum shows five main peaks with the approximate ratios 1:4:6:4:1 as regards coupling. This paper presents another approach featuring analysis of the entire spectrum: (i) ratios of identified peaks, (ii) ratio variation vs time with regard to several parameters affecting fading. These variations in the alanine spectrum are probably correlated with the variation of the concentrations of different free radical species. These variations and their positions in the spectrum are very important constraints that increase the uncertainty of this type of measurement.


Subject(s)
Alanine/chemistry , Alanine/radiation effects , Algorithms , Electron Spin Resonance Spectroscopy/methods , Radiometry/methods , Dose-Response Relationship, Radiation , Electron Spin Resonance Spectroscopy/instrumentation , Equipment Design , Equipment Failure Analysis/methods , Microwaves , Radiation Dosage , Radiometry/instrumentation , Reproducibility of Results , Sensitivity and Specificity