1.
Pol Merkur Lekarski ; 41(245): 221-224, 2016 Nov 25.
Article in Polish | MEDLINE | ID: mdl-27883348

ABSTRACT

The aim of the artificial heart stimulation is not only saving lives, but also improvement of the quality of life of patients with cardiac arrhythmias. One of the key dimensions of quality of life is psychological functioning. Until now, little research assess this dimension in patients before the implantation of the heart rhythm control device. AIM: The aim of the study was to assess the severity of depression and anxiety and the frequency of the used cognitive emotion regulation strategies and to examine the relationship between them. MATERIALS AND METHODS: The study group consisted of 60 people qualified for pacemaker implantation (42 PM patients and 18 ICD): 15 women and 45 men ranging in age from 43 to 85. To assess cognitive emotion regulation strategies Cognitive Emotion Regulation Questionnaire was used, and to assess the severity of depression and anxiety - Mood Assessment Questionnaire. RESULTS: Patients with PM more often than patients with ICD use the strategy of Positive Reappraisal (U = 231.50, p = 0.045). There were no statistically significant differences in the frequency of use of other strategies and severity of depression and anxiety. In PM patients there are negative correlations between the severity of depression and anxiety and the use of Acceptance ( τ = -0.380), a Positive Reappraisal ( τ = -0.278), Positive Refocusing ( τ = -0.366) and between the level of anxiety and Putting into Perspective ( τ = -0.402). In ICD patients there was a positive relationship between anxiety and Cathastrophizing ( τ = 0.324). CONCLUSIONS: The severity of depression and anxiety, and emotion regulation strategies in patients qualified for PM implantation in comparison with patients qualified for ICD implantation are similar. Both groups of patients show a good adaptation of the psychological.


Subject(s)
Anxiety/physiopathology , Arrhythmias, Cardiac/therapy , Defibrillators, Implantable/psychology , Depression/physiopathology , Emotions , Patients/psychology , Quality of Life/psychology , Adaptation, Psychological , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Poland , Stress, Psychological , Surveys and Questionnaires
2.
Kardiol Pol ; 72(6): 576-82, 2014.
Article in Polish | MEDLINE | ID: mdl-24961459

ABSTRACT

In December 2010 St. Jude Medical informed about higher incidence of silicone insulation abrasion in implantable cardioverter-defibrillator leads Riata/Riata ST. The manifestation of this phenomenon is the externalisation of conductors outside the body of the lead, which is visible in a fluoroscopy. The abrasion could also involve an insulation under high-voltage coil and in the worst case could result in a short circuit within high voltage part of the system. The incidence of this phenomenon varies from part of to several dozen percent according to published papers and becomes higher in a longer follow-up. The highest probability of malfunction in 8 F single coil and the lowest in 7 F dual-coil leads is observed. For the needs of this guidelines all Riata/Riata ST leads were divided into: functioning, damaged but active (visible externalisation but electrically functioning), malfunctioning. In the last case the lead should be removed and a new one implanted (class of indication I) ,although only implantation of a new lead with abandoning malfunctioning one is allowed and should be considered (IIa). In patients with functioning lead extraction with a new lead implantation may be considered during elective replacement only in high risk patients (IIb). In case of damaged but active lead its extraction with the implantation of a new lead during elective replacement of the device should be considered in high risk population (IIa) and may be considered in other patients (IIb). The final decision related to Riata/Riata ST should be individualised and undertaken in co-operation with the patient after detailed assessment of the risk related to each treatment option.


Subject(s)
Cardiology/standards , Cardiomyopathies/therapy , Defibrillators, Implantable/standards , Device Removal/standards , Electrodes, Implanted , Germany , Humans , Practice Guidelines as Topic
3.
Pol Arch Med Wewn ; 111(4): 489-93, 2004 Apr.
Article in Polish | MEDLINE | ID: mdl-15517764

ABSTRACT

Scimitar syndrome is a rare congenital anomaly. This syndrome is characterized by partial or complete anomalous pulmonary venous drainage of the right lung to the inferior vena cava. There is a characteristic abnormal radiographic shadow which descends along the right cardiac border (scimitar sign). We examined 71-year old woman with severe pulmonary hypertension due to a large shunt between pulmonary veins and right atrium. Other cause of pulmonary hypertension is atrial septum defect. Our patient required permanent pacemaker implantation for tachy-brady syndrome.


Subject(s)
Hypertension, Pulmonary/etiology , Scimitar Syndrome , Aged , Female , Humans , Pacemaker, Artificial , Scimitar Syndrome/complications , Scimitar Syndrome/diagnostic imaging , Scimitar Syndrome/therapy , Tomography, X-Ray Computed