Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
Add more filters










Publication year range
1.
Sensors (Basel) ; 24(2)2024 Jan 15.
Article in English | MEDLINE | ID: mdl-38257630

ABSTRACT

Bite force measurements are crucial in the realm of biomedical research, particularly in the areas of dentistry and orthodontic care. Various intraoral devices have been used to assess biting force, but each has limitations and drawbacks. Fiber optic sensors (FOSs) offer advantages such as electrical inertness, immunity to electromagnetic interference, and high sensitivity. Distributed fiber optic sensing allows an increase in the number of sensing points and can interrogate numerous reflections from scattering events within an optical fiber. We present four dental bites with heights of 6 mm, which enabled bilateral measurements. U-shaped sensors were prepared by embedding fibers into silicone by folding a single-mode fiber into four lines and multiplexing eight parallel nanoparticle-doped fibers. Dental bite models were created using two silicone materials (Sorta Clear 18 and Sorta Clear 40). The developed sensors were calibrated by applying weights up to 900 g, resulting in a linear response. Experiments were conducted to compare the efficacy of the dental bites. The collection of massive data was enabled by constructing a 2D map of the dental bites during multi-point sensing.

2.
Sensors (Basel) ; 22(22)2022 Nov 14.
Article in English | MEDLINE | ID: mdl-36433396

ABSTRACT

Fiber-optic sensors are a powerful tool to investigate physical properties like temperature, strain, and pressure. Such properties make these sensors interesting for many applications including biomedical applications. Fiber sensors are also a great platform for distributed sensing by using the principles of optical frequency domain reflectometry. Distributed sensing is becoming more and more used to achieve high-resolution measurements and to map physical properties of biomaterials at small scale, thus obtaining 2D and 3D mapping of a particular area of interest. This work aims at building and investigating a 2D sensing carpet based on a distributed fiber sensing technique, to map local pressure applied to the carpet. The two-dimensional mapping is obtained by embedding a single-mode optical fiber inside a soft silicone carpet. The fiber has been bent and arranged in a specific configuration characterized by several parallel lines. Different fiber fixation methods have been investigated by means of a comparative analysis to perform better characterization and to achieve a more precise response of the carpet. The best pressure sensitivity coefficient (0.373 pm/kPa or considering our setup 1.165 nm/kg) was detected when the fiber was fully embedded inside the silicone carpet. This paper demonstrates the possibility of mapping a 2D distributed pressure over a surface with a resolution of 2 mm by 2 mm. The surface of investigation is 2 cm by 6 cm, containing 310 sensing points. The sensing carpet has been validated selecting several preferential positions, by testing the consistency of the results over different portions of the carpet.


Subject(s)
Floors and Floorcoverings , Silicones , Optical Fibers , Fiber Optic Technology , Temperature
3.
Biosensors (Basel) ; 11(11)2021 Nov 11.
Article in English | MEDLINE | ID: mdl-34821662

ABSTRACT

Epidural anesthesia is a pain management process that requires the insertion of a miniature needle through the epidural space located within lumbar vertebrae. The use of a guidance system for manual insertion can reduce failure rates and provide increased efficiency in the process. In this work, we present and experimentally assess a guidance system based on a network of fiber optic distributed sensors. The fibers are mounted externally to the needle, without blocking its inner channel, and through a strain-to-shape detection method reconstruct the silhouette of the epidural device in real time (1 s). We experimentally assessed the shape sensing methods over 25 experiments performed in a phantom, and we observed that the sensing system correctly identified bending patterns typical in epidural insertions, characterized by the different stiffness of the tissues. By studying metrics related to the curvatures and their temporal changes, we provide identifiers that can potentially serve for the (in)correct identification of the epidural space, and support the operator through the insertion process by recognizing the bending patterns.


Subject(s)
Anesthesia, Epidural , Fiber Optic Technology , Anesthesia, Epidural/methods , Epidural Space/diagnostic imaging , Humans , Needles
4.
Sci Rep ; 11(1): 8609, 2021 04 21.
Article in English | MEDLINE | ID: mdl-33883650

ABSTRACT

This paper presents the performance analysis of the system for real-time reconstruction of the shape of the rigid medical needle used for minimally invasive surgeries. The system is based on four optical fibers glued along the needle at 90 degrees from each other to measure distributed strain along the needle from four different sides. The distributed measurement is achieved by the interrogator which detects the light scattered from each section of the fiber connected to it and calculates the strain exposed to the fiber from the spectral shift of that backscattered light. This working principle has a limitation of discriminating only a single fiber because of the overlap of backscattering light from several fibers. In order to use four sensing fibers, the Scattering-Level Multiplexing (SLMux) methodology is applied. SLMux is based on fibers with different scattering levels: standard single-mode fibers (SMF) and MgO-nanoparticles doped fibers with a 35-40 dB higher scattering power. Doped fibers are used as sensing fibers and SMFs are used to spatially separate one sensing fiber from another by selecting appropriate lengths of SMFs. The system with four fibers allows obtaining two pairs of opposite fibers used to reconstruct the needle shape along two perpendicular axes. The performance analysis is conducted by moving the needle tip from 0 to 1 cm by 0.1 cm to four main directions (corresponding to the locations of fibers) and to four intermediate directions (between neighboring fibers). The system accuracy for small bending (0.1-0.5 cm) is 90[Formula: see text] and for large bending (0.6-1 cm) is approximately 92[Formula: see text].

5.
Sensors (Basel) ; 21(3)2021 Jan 27.
Article in English | MEDLINE | ID: mdl-33513666

ABSTRACT

Thermal ablation is achieved by delivering heat directly to tissue through a minimally invasive applicator. The therapy requires a temperature control between 50-100 °C since the mortality of the tumor is directly connected with the thermal dosimetry. Existing temperature monitoring techniques have limitations such as single-point monitoring, require costly equipment, and expose patients to X-ray radiation. Therefore, it is important to explore an alternative sensing solution, which can accurately monitor temperature over the whole ablated region. The work aims to propose a distributed fiber optic sensor as a potential candidate for this application due to the small size, high resolution, bio-compatibility, and temperature sensitivity of the optical fibers. The working principle is based on spatial multiplexing of optical fibers to achieve 3D temperature monitoring. The multiplexing is achieved by high-scattering, nanoparticle-doped fibers as sensing fibers, which are spatially separated by lower-scattering level of single-mode fibers. The setup, consisting of twelve sensing fibers, monitors tissue of 16 mm × 16 mm × 25 mm in size exposed to a gold nanoparticle-mediated microwave ablation. The results provide real-time 3D thermal maps of the whole ablated region with a high resolution. The setup allows for identification of the asymmetry in the temperature distribution over the tissue and adjustment of the applicator to follow the allowed temperature limits.


Subject(s)
Metal Nanoparticles , Optical Fibers , Animals , Gold , Humans , Liver , Magnesium Oxide , Swine , Temperature
6.
Sci Rep ; 10(1): 12593, 2020 07 28.
Article in English | MEDLINE | ID: mdl-32724053

ABSTRACT

The high demand in effective and minimally invasive cancer treatments, namely thermal ablation, leads to the demand for real-time multi-dimensional thermometry to evaluate the treatment effectiveness, which can be also assisted by the use of nanoparticles. We report the results of 20-nm gold and magnetic iron oxide nanoparticles-assisted laser ablation on a porcine liver phantom. The experimental set-up consisting of high-scattering nanoparticle-doped fibers was operated by means of a scattering-level multiplexing arrangement and interrogated via optical backscattered reflectometry, together with a solid-state laser diode operating at 980 nm. The multiplexed 2-dimensional fiber arrangement based on nanoparticle-doped fibers allowed an accurate superficial thermal map detected in real-time.


Subject(s)
Hot Temperature , Laser Therapy/methods , Metal Nanoparticles/chemistry , Animals , Biosensing Techniques , Gold/chemistry , Microscopy, Electron, Scanning , Microscopy, Electron, Transmission , Spectrophotometry, Ultraviolet , Swine , Thermometry/methods , X-Ray Diffraction
7.
Sensors (Basel) ; 20(12)2020 Jun 17.
Article in English | MEDLINE | ID: mdl-32560320

ABSTRACT

Wearable light textiles are gaining widespread interest in application for measurement and monitoring of biophysical parameters. Fiber optic sensors, in particular Bragg Grating (FBG) sensors, can be a competitive method for monitoring of respiratory behavior for chest and abdomen regions since the sensors are able to convert physical movement into wavelength shift. This study aims to show the performance of elastic belts with integrated optical fibers during the breathing activities done by two volunteers. Additionally, the work aims to determine how the positions of the volunteers affect the breathing pattern detected by optical fibers. As a reference, commercial mobile application for sensing vibration is used. The obtained results show that the FBGs are able to detect chest and abdomen movements during breathing and consequently reconstruct the breathing pattern. The accuracy of the results varies for two volunteers but remains consistent.


Subject(s)
Fiber Optic Technology , Monitoring, Physiologic/instrumentation , Respiratory Rate , Textiles , Female , Humans , Male , Young Adult
8.
Sensors (Basel) ; 20(9)2020 May 02.
Article in English | MEDLINE | ID: mdl-32370219

ABSTRACT

Optical backscatter reflectometry (OBR) is a method for the interrogation of Rayleigh scattering occurring in each section of an optical fiber, resulting in a single-fiber-distributed sensor with sub-millimeter spatial resolution. The use of high-scattering fibers, doped with MgO-based nanoparticles in the core section, provides a scattering increase which can overcome 40 dB. Using a configuration-labeled Scattering-Level Multiplexing (SLMux), we can arrange a network of high-scattering fibers to perform a simultaneous scan of multiple fiber sections, therefore extending the OBR method from a single fiber to multiple fibers. In this work, we analyze the performance and boundary limits of SLMux, drawing the limits of detection of N-channel SLMux, and evaluating the performance of scattering-enhancement methods in optical fibers.

9.
Opt Express ; 27(16): 22074-22087, 2019 Aug 05.
Article in English | MEDLINE | ID: mdl-31510502

ABSTRACT

A novel approach for fiber optics 3D shape sensing, applicable to mini-invasive bio-medical devices, is presented. The approach exploits the optical backscatter reflectometry (OBR) and an innovative setup that permits the simultaneous spatial multiplexing of an optical fibers parallel. The result is achieved by means of a custom-made enhanced backscattering fiber whose core is doped with MgO-based nanoparticles (NP). This special NP-doped fiber presents a backscattering-level more than 40 dB higher with respect to a standard SMF-28. The fibers parallel is built to avoid overlap between NP-doped fibers belonging to different branches of the parallel, so that the OBR can distinguish the more intense backscattered signal coming from the NP-doped fiber. The system is tested by fixing, with epoxy glue, 4 NP-doped fibers along the length of an epidural needle. Each couple of opposite fibers senses the strain on a perpendicular direction. The needle is inserted in a custom-made phantom that simulates the spine anatomy. The 3D shape sensing is obtained by converting the measured strain in bending and shape deformation.

10.
Nanomaterials (Basel) ; 9(4)2019 Mar 31.
Article in English | MEDLINE | ID: mdl-30935156

ABSTRACT

Magnetic Fe3O4 nanoparticles (NPs) and their surface modification with therapeutic substances are of great interest, especially drug delivery for cancer therapy, including boron-neutron capture therapy (BNCT). In this paper, we present the results of boron-rich compound (carborane borate) attachment to previously aminated by (3-aminopropyl)-trimethoxysilane (APTMS) iron oxide NPs. Fourier transform infrared spectroscopy with Attenuated total reflectance accessory (ATR-FTIR) and energy-dispersive X-ray analysis confirmed the change of the element content of NPs after modification and formation of new bonds between Fe3O4 NPs and the attached molecules. Transmission (TEM) and scanning electron microscopy (SEM) showed Fe3O4 NPs' average size of 18.9 nm. Phase parameters were studied by powder X-ray diffraction (XRD), and the magnetic behavior of Fe3O4 NPs was elucidated by Mössbauer spectroscopy. The colloidal and chemical stability of NPs was studied using simulated body fluid (phosphate buffer-PBS). Modified NPs have shown excellent stability in PBS (pH = 7.4), characterized by XRD, Mössbauer spectroscopy, and dynamic light scattering (DLS). Biocompatibility was evaluated in-vitro using cultured mouse embryonic fibroblasts (MEFs). The results show us an increasing of IC50 from 0.110 mg/mL for Fe3O4 NPs to 0.405 mg/mL for Fe3O4-Carborane NPs. The obtained data confirm the biocompatibility and stability of synthesized NPs and the potential to use them in BNCT.

11.
Biomed Opt Express ; 10(3): 1282-1296, 2019 Mar 01.
Article in English | MEDLINE | ID: mdl-30891346

ABSTRACT

We propose a setup for multiplexed distributed optical fiber sensors capable of resolving temperature distribution in thermo-therapies, with a spatial resolution of 2.5 mm over multiple fibers interrogated simultaneously. The setup is based on optical backscatter reflectometry (OBR) applied to optical fibers having backscattered power significantly larger than standard fibers (36.5 dB), obtained through MgO doping. The setup is based on a scattering-level multiplexing, which allows interrogating all the sensing fibers simultaneously, thanks to the fact that the backscattered power can be unambiguously associated to each fiber. The setup has been validated for the planar measurement of temperature profiles in ex vivo radiofrequency ablation, obtaining the measurement of temperature over a surface of 96 total points (4 fibers, 8 sensing points per cm2). The spatial resolution obtained for the planar measurement allows extending distributed sensing to surface, or even three-dimensional, geometries performing temperature sensing in the tissue with millimeter resolution in multiple dimensions.

12.
Sensors (Basel) ; 19(1)2018 Dec 22.
Article in English | MEDLINE | ID: mdl-30583517

ABSTRACT

Etched fiber Bragg grating (EFBG)-based sensors are used as evanescent field sensors for refractive index detection. When the fiber thickness is thin and the refractive index sensitivity increases, the number of propagating modes increases, resulting in a spectral enlargement that complicates the interrogation of the sensor. In this work, we present a method to analyze the spectrum of a multimode etched fiber Bragg grating (MMEFBG) in the wavelet domain, which analyzes the amount of spectral density independently from the peak reflectivity value. The proposed interrogation method permits defining the integral of the spectral density as a novel and unconventional estimator. With respect to the conventional estimators based on wavelength shift, this estimator can better exploit the larger amount of information given by the spectral enlargement typical of multimode behavior. Results were obtained by etching an MMEFBG in hydrofluoric acid and using water/sucrose mixtures to evaluate the refractive index sensitivity, validating the interrogation method.

13.
Opt Lett ; 43(24): 5945-5948, 2018 Dec 15.
Article in English | MEDLINE | ID: mdl-30547976

ABSTRACT

We demonstrate and experimentally validate a fiber optic refractive index (RI) sensor obtained by simply etching a high-scattering MgO-based nanoparticle-doped single-mode fiber in hydrofluoric acid (HF). The fiber has 32.3 dB stronger Rayleigh scattering than a standard fiber, allowing a detection of scattering spectral signatures with an optical backscatter reflectometer, even when the core is exposed to the outer RI. The obtained sensitivity is 1.53 nm/RIU (RI units), measured by correlating the scattering spectra. We prove the possibility of implementing a distributed RI detection (seven locations spaced by 1 mm). The fabrication method for this RI sensor is simplified, since it simply requires etching in an HF bath, without the need of inscribing reflective elements or fabricating microstructures in the fiber.

14.
Sensors (Basel) ; 18(12)2018 Dec 06.
Article in English | MEDLINE | ID: mdl-30563228

ABSTRACT

A biosensor based on an etched Fiber Bragg Grating (EFBG) for thrombin detection is reported. The sensing system is based on a Fiber Bragg Grating (FBG) with a Bragg wavelength of 1550 nm, wet-etched in hydrofluoric acid (HF) for ~27 min, to achieve sensitivity to a refractive index (RI) of 17.4 nm/RIU (refractive index unit). Subsequently, in order to perform a selective detection of thrombin, the EFBG has been functionalized with silane-coupling agent 3-(aminopropyl)triethoxysilane (APTES) and a cross-linker, glutaraldehyde, for the immobilization of thrombin-binding aptamer. The biosensor has been validated for thrombin detection in concentrations ranging from 10 nM to 80 nM. The proposed sensor presents advantages with respect to other sensor configurations, based on plasmonic resonant tilted FBG or Long Period Grating (LPG), for thrombin detection. Firstly, fabricating an EFBG only requires chemical etching. Moreover, the functionalization method used in this study (silanization) allows the avoidance of complicated and expensive fabrications, such as thin film sputtering or chemical vapor deposition. Due to their characteristics, EFBG sensors are easier to multiplex and can be used in vivo. This opens new possibilities for the detection of thrombin in clinical settings.


Subject(s)
Aptamers, Nucleotide/analysis , Biosensing Techniques/methods , Optical Fibers , Calibration , Microscopy, Atomic Force , Refractometry
15.
Micromachines (Basel) ; 9(5)2018 Apr 28.
Article in English | MEDLINE | ID: mdl-30424142

ABSTRACT

The dental industry without lasers is inconceivable right now. This captivating technology has outlasted other possible alternative technologies applied in dentistry in the past due to its precision, accuracy, minimal invasive effect as well as faster operating time. Other alternatives such as soldering, resistance (spot) welding, plasma (torch) welding, and single pulse tungsten inert gas welding have their pros and cons; nevertheless, laser welding remains the most suitable option so far for dental application. This paper attempts to give an insight into the laser principle and types of lasers used for dental purposes, types of dental alloys used by the dentist, and effect of laser parameters on prosthesis/implants. It is apparent from the literature review that laser assisted dental welding will continue to grow and will become an unparalleled technology for dental arena.

16.
Opt Lett ; 43(20): 5106-5109, 2018 Oct 15.
Article in English | MEDLINE | ID: mdl-30320831

ABSTRACT

We demonstrate a largely tunable dispersion fiber Bragg grating (FBG) inscribed in a microstructured polymer optical fiber (mPOF). The bandwidth of the chirped FBG (CFBG) was achieved from 0.11 to 4.86 nm, which corresponds to a tunable dispersion range from 513.6 to 11.15 ps/nm. Furthermore, thermal sensitivity is used to compensate for the wavelength shift due to the applied strain. These results demonstrate that a CFBG in a POF is a promising technology for future optical systems.

17.
Opt Express ; 26(14): 18708-18720, 2018 Jul 09.
Article in English | MEDLINE | ID: mdl-30114044

ABSTRACT

In this work, a partially etched chirped fiber Bragg grating (pECFBG) is introduced, as a compact sensor for multi-parametric measurement of temperature, thermal gradients over the active length, and refractive index. The sensor is fabricated by wet-etching a portion of a 14-mm linearly chirped FBG with linear chirp profile. The resulting device has two active areas: the unetched part of the grating (2 mm) can be used either as a uniform temperature sensor, or to detect thermal gradients experienced through the grating length by means of a spectral reconstruction technique; the etched part (12 mm), besides having a similar thermal sensitivity, is exposed to refractive index sensing through the introduction of a sensitivity to external refractive index. Overall, the pECFBG structure behaves as a compact sensor with multi-parameter capability, that can both measure temperature and refractive index on the same grating, but also spatially resolve temperature detection through the grating section. The results have been validated through both a model and experimental setup, showing that the mutual correlation algorithm applied to different spectral parts of the grating is able to discriminate between uniform and gradient-shaped temperature profiles, and refractive index changes.

SELECTION OF CITATIONS
SEARCH DETAIL
...