Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Otol Neurotol ; 43(7): 773-780, 2022 08 01.
Article in English | MEDLINE | ID: mdl-35878633

ABSTRACT

OBJECTIVE: To compare the outcomes of patients with unilateral otosclerosis treated consecutively by a hearing aid then stapedotomy. STUDY DESIGN: Monocentric, nonrandomized, prospective, longitudinal, cohort study. SETTING: Tertiary university hospital. PATIENTS: Adult patients with a unilateral conductive hearing loss of at least 30 dB caused by otosclerosis. INTERVENTIONS: Consecutive treatment by an external hearing aid followed by stapedotomy. MAIN OUTCOME MEASURES: Differences between hearing aids and stapedotomy in quality of life, pure-tone audiometry, binaural hearing, tinnitus severity, and patient satisfaction. RESULTS: Twenty-two patients were included, of which 20 (91%) underwent stapedotomy. Stapedotomy demonstrated increased quality of life according to Glasgow Health Status Inventory scores versus hearing aids (+10.4 ± 9.4 [p = 0.0001]). Stapedotomy versus hearing aids showed improved pure-tone averages (-11.1 ± 11.0 dB [p = 0.002]) and air-bone gaps (-11.8 ± 10.7 dB [p = 0.0006]). Stapedotomy was superior to hearing aids for speech-in-noise recognition in the reverse dichotic condition (-8.4 ± 26.9 dB [p = 0.004]) and showed improved sound localization accuracy in root mean square error (-14.5 ± 24.5 degrees [p = 0.02]). Stapedotomy, but not hearing aids, showed improved patient self-evaluated tinnitus after baseline adjustment according to the Tinnitus Handicap Inventory (-8.0 ± 13.4 [p = 0.02]) and visual analog scale for tinnitus intensity (-28.7 ± 34.1 [p = 0.006]). Overall, patients were more satisfied with surgery versus hearing aids. CONCLUSIONS: Stapedotomy remains more effective compared with hearing aids with greater improvements in quality of life, patient satisfaction, hearing outcomes, and self-evaluated tinnitus.


Subject(s)
Otosclerosis , Stapes Surgery , Tinnitus , Adult , Audiometry, Pure-Tone , Cohort Studies , Hearing Loss, Conductive/etiology , Hearing Loss, Conductive/surgery , Humans , Otosclerosis/complications , Otosclerosis/surgery , Prospective Studies , Quality of Life , Tinnitus/etiology , Tinnitus/surgery , Treatment Outcome
2.
Laryngoscope Investig Otolaryngol ; 6(6): 1414-1420, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34938882

ABSTRACT

OBJECTIVE: Different procedures have been described to treat superior canal dehiscence. The present study aims to describe the results obtained with middle fossa approach, transmastoid approach, and round window reinforcement in a large series of patients. METHODS AND DESIGN: In this single-center retrospective study, we report the results of the procedures performed between 2006 and 2019 using the three main surgical approaches, middle fossa approach (MFA), transmastoid approach (TMA), and round window reinforcement (RWR). The outcome on cardinal cochlear and vestibular symptoms, audiometric results, and changes in cervical vestibular evoked myogenic potentials (cVEMPs) were analyzed. The patients were also interviewed 12 months to 13 years post-treatment to establish their overall satisfaction following surgery. RESULTS: Sixty-three patients were divided into three groups: 42 MFA; 12 RWR; 9 TMA. Postsurgical control rates exceeded 80% for the majority of symptoms in the MFA and TMA groups, and ranged from 11.1% to 83.3% for the RWR group. Over 90% of MFA or TMA patients and 60% of the RWR cohort were satisfied overall with their treatment. Hearing thresholds were intact following surgery in the MFA and TMA groups. There was one case of profound postoperative deafness in the RWR group. CONCLUSION: MFA and TMA are both safe and effective techniques in the treatment of disabling SSCD. Since MFA is the more invasive technique, we suggest that TMA should be proposed as first-line treatment, temporal bone anatomy permitting. RWR outcomes are more variable in term of symptomatic control, and this option could be offered to patients at risk under general anesthesia. LEVEL OF EVIDENCE: Level 4 evidence.

4.
Ear Hear ; 40(4): 905-917, 2019.
Article in English | MEDLINE | ID: mdl-30335668

ABSTRACT

OBJECTIVE: Normal-hearing subjects listening to acoustic simulations of cochlear implants (CI) can obtain sentence recognition scores near 100% in quiet and in 10 dB signal-to-noise ratio (SNR) noise with acute exposure. However, average sentence recognition scores for real CI listeners are generally lower, even after months of experience, and there is a high degree of heterogeneity. Our aim was to identify the relative importance and strength of factors that prevent CI listeners from achieving early, 1-mo scores as high as those for normal-hearing-listener acoustic simulations. DESIGN: Sentence recognition scores (100 words/list, 65 dB SPL) using CI alone were collected for all adult unilateral CI listeners implanted in our center over a 5-yr period. Sentence recognition scores in quiet and in 10 dB SNR 8-talker babble, collected from 1 to 12 mo, were reduced to a single dependent variable, the "initial" score, via logarithmic regression. "Initial" scores equated to an improved estimate of 1-mo scores, and integrated the time to rise above zero score for poorer performing subjects. Demographic, device, and medical data were collected for 118 subjects who met standard CI candidacy criteria. Computed tomography of the electrode array allowing determination of the insertion depth as an angle, and the presence or absence of scala dislocation was available for 96 subjects. Predictive factors for initial scores were selected using stepwise multiple linear regression. The relative importance of predictive factors was estimated as partial r with a low bias method, and statistical significance tested with type II analysis of variance. RESULTS: The etiologies chronic otitis and autoimmune disease were associated with lower, widely variable sentence recognition scores in the long-term. More than 60% of CI listeners scored >50/100 in quiet at 1 mo. Congenital hearing loss was associated with significantly lower initial scores in quiet (r 0.23, p < 0.001), as was longer duration of hearing loss (r 0.12, p < 0.001, -0.76 pts per year). Initial scores were negatively correlated with insertion depth (r 0.09, p < 0.001, -0.1 pts per degree), with the highest initial scores being obtained for insertion depths of 300° to 400°. A much greater proportion of scala dislocations was found for perimodiolar arrays compared with straight arrays. Scores were negatively correlated with the proportion of the active electrode array found in scala vestibuli for Nucleus perimodiolar devices (r 0.14, p < 0.01, coefficient -25). Similar overall results were obtained for sentence recognition scores in noise (+10 dB SNR). The intercept value for the obtained regression functions indicated that CI listeners with the least limiting factors generally scored ~95/100 in quiet and ~90/100 in noise. In addition, CI listeners with insertion angles as low as 315° to 360° could obtain sentence recognition scores >80/100 even at 1 day after activation. Insertion depths of 360° were estimated to produce frequency-place mismatches of about one octave upward shift. CONCLUSIONS: Patient-related factors etiology and duration of deafness together explained ~40% of the variance in early sentence recognition scores, and electrode position factors ~20%. CI listeners with insertion depths of about one turn obtained the highest early sentence recognition scores in quiet and in noise, and these were comparable with those reported in the literature for normal-hearing subjects listening to 8 to 12 channel vocoder simulations. Differences between device brands were largely explained by differences in insertion depths. This indicates that physiological frequency-place mismatches of about one octave are rapidly accommodated by CI users for understanding sentences, between 1 day to 1 mo postactivation, and that channel efficiency may be significantly poorer for more deeply positioned electrode contacts.


Subject(s)
Cochlear Implantation/methods , Hearing Loss/rehabilitation , Speech Perception , Adult , Aged , Aged, 80 and over , Autoimmune Diseases/complications , Chronic Disease , Cone-Beam Computed Tomography , Ear, Inner/diagnostic imaging , Female , Hearing Loss/congenital , Hearing Loss/etiology , Humans , Imaging, Three-Dimensional , Linear Models , Male , Middle Aged , Otitis Media/complications , Severity of Illness Index , Signal-To-Noise Ratio , Time Factors , Tomography, Spiral Computed , Treatment Outcome , Young Adult
5.
Int J Surg Case Rep ; 37: 10-12, 2017.
Article in English | MEDLINE | ID: mdl-28618349

ABSTRACT

Stensen duct injury has been reported in the medical literature following penetrating injuries of the cheek or by exeresis of tumors of the cheek or of the oral mucosa. This type of physical trauma often arises from injuries as a result being assaulted (e.g. with knife) or from road accidents. The complexity of the damage to the anatomical structures and the causative agent sometimes makes the diagnosis difficult. We report on a clinical case of managemenent Stensen duct injury secondary of goring by a cow horn.

SELECTION OF CITATIONS
SEARCH DETAIL
...