Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Clin Cardiol ; 30(9): 437-42, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17803209

ABSTRACT

Multislice computed tomography coronary angiography (MSCT-CA) has emerged as a powerful noninvasive diagnostic modality to visualize the coronary arteries and to detect significant coronary stenoses. The latest generation 64-slice computed tomography (CT) scanners is a robust technique which allows high-resolution, isotropic, nearly motion-free coronary imaging. Coronary stenoses are detected with high sensitivity and a normal scan accurately rules out the presence of a coronary stenosis. With the introduction of further novel concepts in CT-technology one may expect that MSCT-CA will become a clinically used diagnostic tool.


Subject(s)
Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Tomography, Spiral Computed/methods , Humans , Predictive Value of Tests
2.
Radiol Med ; 112(4): 526-37, 2007 Jun.
Article in English, Italian | MEDLINE | ID: mdl-17568993

ABSTRACT

PURPOSE: The purpose of this study was to assess the diagnostic accuracy of 64-slice computed tomography (64-CT) coronary angiography in the detection of coronary in-stent restenosis. MATERIALS AND METHODS: Ninety-five patients (72 men and 23 women, mean age 58+/-8 years) with previous percutaneous coronary intervention with stenting and suspected restenosis underwent 64-CT (Sensation 64, Siemens). The mean time between stent deployment and 64-CT was 6.1+/-4.2 months. The scan parameters were: slices 32 x 2, individual detector width 0.6 mm, rotation time 0.33 s, feed 3.84 mm/rotation, 120 kV, 900 mAs. After the intravenous administration of iodinated contrast material (Iomeprol 400 mgI/ml, Iomeron, Bracco) and a bolus chaser (40 ml of saline), the scan was completed in <12 s. All coronary segments with a stent were assessed on 64-CT by two observers in consensus and judged as: patent, with intimal hyperplasia (lumen reduction of <50%), with in-stent restenosis (> or =50%), or with in-stent occlusion (100%). The consensus reading was compared with conventional coronary angiography. RESULTS: Four patients were excluded because of insufficient image quality. In the remaining 91, we assessed 102 stents (31 RCA; 10 LM; 54 LAD; 7 CX). In 14 (13.7%) stents, in-stent restenosis (n=8) or in-stent occlusion (n=6) was found. Intimal hyperplasia was detected in 11 (10.8%) stents. The sensitivity and negative predictive value of 64-CT for in-stent occlusion were 100% and 100%, respectively, whereas for all stenoses, >50% they were 92.9% and 98.7%, respectively. CONCLUSIONS: We found that 64-CT has a high diagnostic accuracy for the detection of in-stent restenosis in a selected patient population.


Subject(s)
Coronary Angiography/methods , Coronary Restenosis/diagnostic imaging , Stents , Tomography, X-Ray Computed , Female , Humans , Male , Middle Aged , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...