Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
1.
Int J Cardiol Heart Vasc ; 47: 101222, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37252196

ABSTRACT

Background: The automated NavX Ensite Precision latency-map (LM) algorithm aims to identify atrial tachycardia (AT) mechanisms. However, data on a direct comparison of this algorithm with conventional mapping are scarce. Methods: Patients scheduled for AT ablation were randomized to mapping with the LM- algorithm (LM group) or to conventional mapping (conventional only group: ConvO), using entrainment and local activation mapping techniques. Several outcomes were exploratively analyzed. Primary endpoint was intraprocedural AT Termination. If AT termination with only automated 3D-Mapping failed, additional conventional methods were applied (conversion). Results: A total of 63 patients (mean 67 years, 34 % female) were enrolled. In the LM group (n = 31), the correct AT mechanism was identified in 14 patients (45 %) using the algorithm alone compared to 30 patients (94 %) with conventional methods. Time to termination of the first AT was not different between groups (LM group 34 ± 20 vs. ConvO 43.1 ± 28.3 min; p = 0.2). However, when AT termination did not occur with LM algorithm, time to termination prolonged significantly (65 ± 35 min; p = 0.01). After applying conventional methods (conversion), procedural termination rates did not differ between LM group (90 %) vs. ConvO (94 %) (p = 0.3). During a follow-up time of 20 ± 9 months, no differences were observed in clinical outcomes. Conclusion: In this small prospective, randomized study, the use of the LM algorithm alone may lead to AT termination, but less accurate than conventional methods.

2.
J Interv Card Electrophysiol ; 64(2): 417-426, 2022 Aug.
Article in English | MEDLINE | ID: mdl-34373981

ABSTRACT

BACKGROUND: Complex ablation for persistent atrial fibrillation (AF) aims to modify the arrhythmogenic substrates to become incapable to perpetuate the arrhythmia. Ablation-associated determinants of atrial tachycardia (AT) rather than AF recurrences are unknown. The aim of the study was to evaluate the association between the type of arrhythmia recurrence and electrophysiological findings during redo procedures. METHODS: A total number of 384 consecutive patients with persistent AF underwent complex ablation consisting of PV isolation (PVI), biatrial electrogram-guided ablation, and linear ablation with the desired procedural endpoint of AF termination. Electrophysiological findings during redo procedures and its relation to AR type are the subject of this study. RESULTS: Overall, 177 (46%) patients underwent a second procedure. Patients with AT recurrences had significantly more often persistent PVI (47 vs. 25%; P = 0.002). Moreover, a higher number of recovered PVs were associated with AF recurrence (3 PVs recovered, AF = 16.1% vs. AT = 5.2%; P = 0.02; 4 PVs recovered, AF = 18.5% vs. AT = 6.3%; P = 0.01), regardless of the extent of substrate ablation during the first procedure. CONCLUSIONS: Durable PV isolation but not the extent of atrial substrate ablation determines the type of arrhythmia recurrence. Thus, the PVs may represent dominant perpetuators (and not only triggers) of persistent AF even in the presence of a significantly modified atrial substrate.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Tachycardia, Supraventricular , Atrial Fibrillation/surgery , Catheter Ablation/methods , Humans , Pulmonary Veins/surgery , Recurrence , Tachycardia, Supraventricular/surgery , Treatment Outcome
4.
J Cardiovasc Electrophysiol ; 30(7): 1026-1035, 2019 07.
Article in English | MEDLINE | ID: mdl-30977168

ABSTRACT

INTRODUCTION: Procedural atrial fibrillation (AF) termination is considered as a predictor of long-term success after catheter ablation for persistent AF (persAF). However, some patients remain free of arrhythmia recurrences despite failure to achieve AF termination. The objective of this study was to assess long-term outcome and prognostic factors in patients undergoing complex ablation without procedural AF termination. METHODS AND RESULTS: This study comprised 419 patients (63.8 ± 10.2 years, 63.4% male) undergoing complex ablation for persAF. Patients without procedural AF termination (n = 137, 64.2 ± 9.7 years, 63.5% male) were categorized into patients who remained in sinus rhythm (SR) in long-term outcome (SR-group) and patients with recurrence of AF or atrial tachycardia (AT) (AR-group). During a follow-up (FU) of 19.6 ± 14.6 months, the SR-group consisted of 65 (47.5%) and the AR-group of 69 (50.4%) patients. Three patients (2.2%) were lost to FU. Left atrial appendage (LAA) flow velocity and left atrium volume index (LAVI) could be identified as predictors for long-term success. LAA flow velocity and baseline AF cycle length (AFCL) were significantly associated with the type of arrhythmia recurrence (AF vs AT), ie, higher values of both are predictive for AT rather than AF recurrences. Patients with a LAVI < 34.4 mL/m² and significant AFCL increase during the ablation procedure had rather AT than AF recurrences. CONCLUSION: Patients with an arrhythmia-free outcome despite failure of procedural AF termination during complex ablation for persAF are characterized by specific morphological and functional properties that are easy to obtain.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Action Potentials , Aged , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/physiopathology , Atrial Function, Left , Catheter Ablation/adverse effects , Female , Heart Rate , Humans , Male , Middle Aged , Progression-Free Survival , Recurrence , Risk Factors , Tachycardia, Supraventricular/etiology , Tachycardia, Supraventricular/physiopathology , Time Factors
5.
Eur Heart J ; 39(38): 3528-3539, 2018 10 07.
Article in English | MEDLINE | ID: mdl-29905797

ABSTRACT

Aims: Aircraft noise causes endothelial dysfunction, oxidative stress, and inflammation. Transportation noise increases the incidence of coronary artery disease, hypertension, and stroke. The underlying mechanisms are not well understood. Herein, we investigated effects of phagocyte-type NADPH oxidase (Nox2) knockout and different noise protocols (around-the-clock, sleep/awake phase noise) on vascular and cerebral complications in mice. Methods and results: C57BL/6j and Nox2-/- (gp91phox-/-) mice were exposed to aircraft noise (maximum sound level of 85 dB(A), average sound pressure level of 72 dB(A)) around-the-clock or during sleep/awake phases for 1, 2, and 4 days. Adverse effects of around-the-clock noise on the vasculature and brain were mostly prevented by Nox2 deficiency. Around-the-clock aircraft noise of the mice caused the most pronounced vascular effects and dysregulation of Foxo3/circadian clock as revealed by next generation sequencing (NGS), suggesting impaired sleep quality in exposed mice. Accordingly, sleep but not awake phase noise caused increased blood pressure, endothelial dysfunction, increased markers of vascular/systemic oxidative stress, and inflammation. Noise also caused cerebral oxidative stress and inflammation, endothelial and neuronal nitric oxide synthase (e/nNOS) uncoupling, nNOS mRNA and protein down-regulation, and Nox2 activation. NGS revealed similarities in adverse gene regulation between around-the-clock and sleep phase noise. In patients with established coronary artery disease, night-time aircraft noise increased oxidative stress, and inflammation biomarkers in serum. Conclusion: Aircraft noise increases vascular and cerebral oxidative stress via Nox2. Sleep deprivation and/or fragmentation caused by noise triggers vascular dysfunction. Thus, preventive measures that reduce night-time aircraft noise are warranted.


Subject(s)
Aircraft , Brain/physiopathology , Endothelium, Vascular/physiopathology , NADPH Oxidase 2/physiology , Noise, Transportation/adverse effects , Sleep Deprivation/physiopathology , Animals , Circadian Clocks/physiology , Cyclic GMP/metabolism , Gene Expression Regulation , Hemodynamics/physiology , Humans , Inflammation/physiopathology , Mice, Inbred C57BL , Mice, Knockout , Models, Animal , Nitric Oxide Synthase Type I/metabolism , Oxidative Stress , Signal Transduction
6.
Europace ; 19(7): 1204-1210, 2017 Jul 01.
Article in English | MEDLINE | ID: mdl-27742774

ABSTRACT

AIMS: Different cardiac arrhythmias have been suggested to be associated with Danon disease, e.g. Wolff-Parkinson-White syndrome. However, a systematic electrophysiological investigation of patients with Danon disease is lacking thus far. METHODS AND RESULTS: Seven patients with Danon disease (4 males, 35.8 ± 10.8 years; 3 females, 51.3 ± 19.9 years) from 3 different families were studied. In all patients, the presence of Danon disease was confirmed by western blot of biopsy material or genetic testing. The patients were characterized by 12-lead electrocardiogram (ECG), Holter ECG, echocardiography, and serial implantable cardioverter defibrillator (ICD) interrogations (in ICD recipients). All male patients underwent electrophysiological investigation (EP study). Asymptomatic ventricular tachyarrhythmias were documented in six of the seven patients. Moreover, 5 of the 7 patients suffered from atrial fibrillation (AF), with 1 of them experiencing thromboembolic stroke at the age of 30 years. In male patients, the initial QRS complex was characterized by a slurring upstroke and shortened PQ interval mimicking ventricular pre-excitation. One male patient showed initial QRS complex slurring with prolonged PR interval. However, the presence of an accessory pathway was excluded by an EP study in all patients. In female patients, initial QRS complex slurring was significantly less distinct. In four patients, ICD implantation was performed for primary prevention of sudden cardiac death. However, sustained ventricular arrhythmias were not documented in any of the patients. CONCLUSIONS: The present study indicates that the distinct surface ECG pattern in Danon disease is not associated with ventricular pre-excitation. Atrial fibrillation is frequently observed in these patients and may be associated with thromboembolic events in the young, while sustained ventricular arrhythmias occur less frequently than previously reported.


Subject(s)
Arrhythmias, Cardiac/etiology , Glycogen Storage Disease Type IIb/complications , Action Potentials , Adult , Aged , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/therapy , Atrioventricular Node/physiopathology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Echocardiography , Electric Countershock/instrumentation , Electrocardiography, Ambulatory , Electrophysiologic Techniques, Cardiac , Female , Glycogen Storage Disease Type IIb/diagnosis , Heart Rate , Humans , Male , Middle Aged , Primary Prevention/instrumentation , Risk Factors , Time Factors
7.
J Cardiovasc Electrophysiol ; 26(12): 1289-94, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26303513

ABSTRACT

INTRODUCTION: Persistent atrial fibrillation (persAF) can occur either as a sustained arrhythmia that has progressed from initially paroxysmal AF or as primary persAF without a history of any spontaneously terminated episode. There is a paucity of data differentiating between the 2 different persAF entities. Thus, we prospectively evaluated baseline characteristics, electrophysiological features, and ablation outcome in these 2 patient cohorts. METHODS AND RESULTS: A total number of 154 consecutive persAF patients (63 ± 10 years, f = 42, longstanding persAF = 60) were characterized in terms of having primary persAF (P-persAF group) or persAF that secondarily progressed from paroxysmal AF (S-persAF group). All patients underwent de novo catheter ablation using the stepwise approach. PersAF entities were characterized by detailed patient history, sequential Holter monitoring, and reports of documented modes of AF conversion, respectively. The P-persAF group had a higher number of young patients (<50 years), a shorter AF history, and a higher number of congestive heart failure. The HATCH score did not differ between the groups. Procedural AF termination rate was significantly higher in S-persAF than in P-persAF patients (n = 55 [81%] vs. n = 58 [68%], P = 0.043). At 1-year follow-up, the arrhythmia-free survival after a single procedure was significantly lower in patients with P-persAF (26% vs. 43%, P = 0.016). Categorization to P-persAF was the strongest independent predictor of arrhythmia recurrence. CONCLUSIONS: P-persAF seems to be a specific arrhythmia entity that is associated with a lower AF-termination rate and a worse outcome after catheter ablation as compared to S-persAF.


Subject(s)
Atrial Fibrillation/physiopathology , Atrial Fibrillation/therapy , Catheter Ablation , Aged , Atrial Fibrillation/classification , Cohort Studies , Disease-Free Survival , Electrocardiography, Ambulatory , Electrophysiological Phenomena , Female , Follow-Up Studies , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Treatment Outcome
8.
Herzschrittmacherther Elektrophysiol ; 26(3): 208-13, 2015 Sep.
Article in German | MEDLINE | ID: mdl-26260681

ABSTRACT

INTRODUCTION: Atrial tachycardia in virtually all areas of both atria has become more important in the clinical management of patients with previous complex atrial fibrillation ablation. Accurate interpretation of surface electrocardiogram (ECG) characteristics is of paramount importance to localize the origin of atrial tachycardia, particularly for planning interventional treatment. This article highlights the ECG features of different types of right and left atrial tachycardia. DEFINITION: Typical right atrial flutter through the cavotricuspid isthmus conducts septally in a cranial direction and demonstrates sawtooth-like flutter waves which start negative in II, III and aVF and then show a steep slope upwards to the isoelectric line. The flutter rate typically ranges between 240-250 beats/min. In contrast, right atrial flutter in a clockwise rotation, flutter around the vena cava inferior or superior and around a scar (e.g. after cardiac surgery) show positive or biphasic flutter waves (lower or upper loop reentry). Left atrial flutter waves (e.g. around the mitral valve or around the pulmonary veins) are very heterogeneous and are typically positive in V1 as the left atrium is located in the posterior mediastinum. CONCLUSION: Specific knowledge of flutter wave morphology in surface ECG facilitates planning and performance of the ablation strategy.


Subject(s)
Atrial Flutter/classification , Atrial Flutter/diagnosis , Electrocardiography/methods , Heart Atria , Diagnosis, Differential , Evidence-Based Medicine , Humans , Reproducibility of Results , Sensitivity and Specificity
9.
Circ Arrhythm Electrophysiol ; 8(5): 1080-7, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26297786

ABSTRACT

BACKGROUND: Pulmonary vein isolation (PVI) is still associated with a substantial number of arrhythmia recurrences in paroxysmal atrial fibrillation (AF). This prospective, randomized study aimed to compare 2 different procedural strategies. METHODS AND RESULTS: A total of 152 patients undergoing de novo ablation for paroxysmal AF were randomized to 2 different treatment arms. The procedure in group A consisted of PVI exclusively. In this group, all isolated PVs were challenged with adenosine to reveal and ablate dormant conduction. In group B, PVI was performed with the patient either in spontaneous or in induced AF. If AF did not terminate with PVI, ablation was continued by targeting extra-PV AF sources with the desired procedural end point of termination to sinus rhythm. Primary study end point was freedom from arrhythmia during 1-year follow-up. In group A, adenosine provoked dormant conduction in 31 (41%) patients with a mean of 1.6±0.8 transiently recovered PVs per patient. Termination of AF during PVI was observed in 31 (65%) patients, whereas AF persisted afterward in 17 (35%) patients. AF termination occurred in 13 (76%) patients by AF source ablation. After 1-year follow-up, significantly more group B patients were free of arrhythmia recurrences (87 versus 68%; P=0.006). During redo ablation, the rate of PV reconduction did not differ between both groups (group A: 55% versus group B: 61%; P=0.25). CONCLUSIONS: Elimination of extra-PV AF sources after PVI is superior to sole PV isolation with the adjunct of abolishing potential dormant conduction. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02238392.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Pulmonary Veins/surgery , Adenosine/administration & dosage , Aged , Anti-Arrhythmia Agents/administration & dosage , Atrial Fibrillation/physiopathology , Electrocardiography , Endpoint Determination , Female , Humans , Male , Middle Aged , Prospective Studies , Pulmonary Veins/physiopathology , Recurrence , Treatment Outcome
10.
J Cardiovasc Electrophysiol ; 26(9): 956-962, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26062031

ABSTRACT

INTRODUCTION: Open irrigated radiofrequency (RF) ablation catheters with a porous tip (56 holes, TC-SF) permit delivering RF energy in a temperature-controlled mode without temperature rise. This prospective observational study investigated the association of different catheter parameters on the occurrence of audible steam pops during left atrial (LA) ablation. METHODS AND RESULTS: A total of 226 patients underwent TC-SF catheter ablation for atrial fibrillation. RF power delivery, impedance and catheter tip temperature were continually recorded throughout the ablation. Pulmonary vein isolation was performed with a maximum of 27 W and LA electrogram-guided or linear ablation with a maximum of 30 W. A total of 59 audible steam pops occurred, 2 of them resulting in pericardial tamponade. In the initial 89 patients, with an irrigation flow rate of 10 mL/min, 18 steam pops with one tamponade occurred in 12 (14%) patients. Subsequently, the irrigation flow rate was increased to 20 mL/min in the following 137 patients, resulting in the occurrence of 41 steam pops including one case of tamponade in a total of 30 (22%) patients. The maximal power was significantly higher in RF applications associated with a pop than those that did not. In only 12 (20%) steam pops, a significant impedance change occurred immediately before pop occurrence (4 [7%] impedance rise >10 ohm, 8 [13%] impedance drop >15 ohm). CONCLUSIONS: The TC-SF catheter does not provide sufficient feedback from the ablated tissue to prevent steam popping.

11.
Herzschrittmacherther Elektrophysiol ; 25(4): 226-9, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25200166

ABSTRACT

Techniques facilitating individual mapping and ablation of arrhythmogenic substrates are desired to enhance our understanding of persistent atrial fibrillation (persAF) mechanisms as a prerequisite to increasing the success rates of single procedure persAF catheter ablation. The technique of body surface potential mapping (BSM) involves the use of multiple electrodes to collect the potentials over a large body surface area and, with the use of a computed tomography scan, it facilitates their correlation to a 3D model of the atrial structures. During AF,the visualization and localization of AF driver activity, both reentrant and focal wavefronts, is possible with this technique. The ECVUE system from CardioInsight was examined for this indication in clinical studies and showed a termination rate of persAF of 63 % in a large multicenter trial (AFACART) with a promising low recurrence rate during follow-up. From our initial experience, the system appears to be effective in persAF patients who have continuous AF for less than 1 year. However, the utility of the system for highly challenging cases like long-standing persistent AF and patients with very short AF cycle length remains to be explored. Further studies are needed to confirm these data and answer the multitude of open questions in this field.


Subject(s)
Atrial Fibrillation/surgery , Body Surface Potential Mapping/methods , Catheter Ablation/methods , Heart Conduction System/surgery , Pulmonary Veins/surgery , Surgery, Computer-Assisted/methods , Chronic Disease , Evidence-Based Medicine , Humans , Treatment Outcome
12.
J Cardiovasc Electrophysiol ; 25(8): 889-895, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24654876

ABSTRACT

INTRODUCTION: Implantable cardioverter defibrillators (ICD) may have the capacity to provoke or worsen ventricular tachyarrhythmias (VT). It has been reported that ICD shocks by itself can increase mortality. This study aimed to determine the role of back-up pacing-induced VT (PIT) in the overall ICD shock burden by avoiding pause-related ventricular back-up pacing. METHODS AND RESULTS: A population of 550 single-chamber ICD patients was studied. Of them, 17 (3%, 69 ± 16 years, 14 male) patients had documented episodes of PIT. A total of 431 VT episodes were documented including 89 (21%) due to PIT. In 3 patients, VT events were exclusively PITs. After ≥2 documented PITs, the pacing output for VVI pacing was set to a subthreshold level resulting in noncapturable ventricular back-up pacing. All other device parameters remained unchanged to prove a potential proarrhythmic effect of pause related back-up pacing. During a follow-up of 99 ± 39 months after reducing the pacing output to a subthreshold level, no further episodes of PIT were observed (P < 0.001). Moreover, with the prevention of PITs, the ICD shock burden decreased significantly (pre: 150 vs. post: 18, P < 0.001). However, a single event of pause-induced VT occurred due to missing back-up pacing. CONCLUSIONS: PIT is a frequent mechanism of VTs in ICD patients resulting in a substantially increased shock burden. Elimination of pause-related back-up pacing by subthreshold pacing output effectively abolishes PIT and thus significantly reduces ICD shock burden.


Subject(s)
Cardiac Pacing, Artificial , Defibrillators, Implantable , Electric Countershock/instrumentation , Pacemaker, Artificial , Prosthesis Failure , Tachycardia, Ventricular/etiology , Aged , Aged, 80 and over , Cardiac Pacing, Artificial/adverse effects , Electric Countershock/adverse effects , Electrophysiologic Techniques, Cardiac , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prosthesis Design , Risk Factors , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/therapy , Time Factors , Treatment Outcome
13.
Naunyn Schmiedebergs Arch Pharmacol ; 386(5): 405-19, 2013 May.
Article in English | MEDLINE | ID: mdl-23443495

ABSTRACT

Our previous studies identified potent antioxidant effects and improvement of vascular function by telmisartan therapy in experimental diabetes and nitrate tolerance. The present study compared the beneficial effects of single telmisartan or amlodipine versus telmisartan/amlodipine combination therapy (T+A) in streptozotocin (STZ)-induced type 1 diabetic rats. Male Wistar rats were injected once with STZ (60 mg/kg, i.v.) and 1 week later the drugs (telmisartan, amlodipine, or T+A) were administrated orally by a special diet (2.5-5 mg kg(-1) day(-1)) for another 7 weeks. We only observed a marginal beneficial on-top effect of T+A therapy over the single drug regimen that was most evident in the improvement of endothelial function (acetylcholine response) and less pronounced in the reduction of whole blood, vascular and cardiac oxidative stress (blood leukocyte oxidative burst, aortic dihydroethidine and 3-nitrotyrosine staining, as well as cardiac NADPH oxidase activity and uncoupling of endothelial nitric oxide synthase) in diabetic rats. These effects on oxidative stress parameters were paralleled by those on the expression pattern of NADPH oxidase and nitric oxide synthase isoforms. In addition, development of mild hypotension in the T+A-treated rats was observed. Reasons for this moderate synergistic effect of T+A therapy may be related to the potent beneficial effects of telmisartan alone and the fact that amlodipine and telmisartan share similar pathways to improve endothelial function. Moreover, hypotension in the T+A-treated rats could partially antagonize the beneficial additive effects by counter-regulatory mechanisms (e.g., activation of the renin-angiotensin-aldosterone system).


Subject(s)
Amlodipine/administration & dosage , Benzimidazoles/administration & dosage , Benzoates/administration & dosage , Diabetes Mellitus, Experimental/drug therapy , Endothelium, Vascular/drug effects , Oxidative Stress/drug effects , Animals , Diabetes Mellitus, Experimental/metabolism , Drug Combinations , Endothelium, Vascular/metabolism , Endothelium, Vascular/physiopathology , Male , Organ Culture Techniques , Oxidative Stress/physiology , Rats , Rats, Wistar , Telmisartan , Treatment Outcome
14.
Europace ; 11(5): 565-70, 2009 May.
Article in English | MEDLINE | ID: mdl-19251707

ABSTRACT

AIMS: We compared a newly developed irrigated gold tip electrode ablation catheter and a gold tip 4 and 8 mm catheter with the corresponding platinum-iridium (Pt) tip catheters in an in vitro setting. METHODS AND RESULTS: In a flow chamber simulating physiological flow conditions, radiofrequency catheter ablation was performed on tissue samples of porcine endomyocardium and liver. Lesion depth, energy and temperature delivery, and popping frequency were determined. Two hundred and fifty-three ablations were conducted. Four and eight millimetre, gold tip electrode catheters produced significantly deeper lesions compared with the Pt tip electrode (liver 4 mm: 4.67 +/- 1.7 vs. 2.9 +/- 1.0 mm, P < 0.0001; endomyocardium 4 mm: 3.88 +/- 1.1 vs. 2.81 +/- 0.7 mm, P < 0.001; liver 8 mm: 3.98 +/- 1.0 vs. 2.03 +/- 1.1 mm, P < 0.001; endomyocardium 8 mm: 4.00 +/- 0.9 vs. 3.39 +/- 0.8 mm, P < 0.001) and correlated with the amount of energy delivery. Popping frequency was significantly higher in gold tip electrodes. In irrigated tip electrodes, there was no difference in the lesion depth comparing gold with Pt (liver: 5.18 +/- 0.7 vs. 5.01 +/- 0.7 mm, P = ns; endomyocardium: 4.89 +/- 0.7 vs. 4.78 +/- 0.8 mm, P = ns). There was a trend towards less popping in the gold tip electrode. CONCLUSION: Both 4 and 8 mm not-irrigated gold tip catheters produced deeper lesions than the corresponding Pt tip catheter. In irrigated tip catheters, gold and Pt tip material did not show differences in the lesion depth.


Subject(s)
Catheter Ablation/instrumentation , Catheter Ablation/methods , Gold , Iridium , Platinum , Animals , Cardiac Surgical Procedures/instrumentation , Cardiac Surgical Procedures/methods , Electrodes , In Vitro Techniques , Liver/surgery , Models, Animal , Swine
15.
Drugs Today (Barc) ; 45(11): 807-24, 2009 Nov.
Article in English | MEDLINE | ID: mdl-20126673

ABSTRACT

Atrial and ventricular arrhythmias are associated with substantial morbidity and mortality and thus are a significant economic burden for healthcare systems. Currently available pharmacological agents have limited efficacy or the risk of relevant side effects, such as drug toxicity and proarrhythmic potential. Recent scientific developments have added new aspects and approaches to this field meriting a fresh review of treatment options. These include novel ion-channel blockers (e.g. dronedarone, celivarone, vernakalant, ranolazine), non-ion channel blockers (e.g. GsMtx4) such as gap junction modulators (rotigaptide) and drugs antagonizing the angiotensin system (ACE-inhibitors, angiotensin II receptor blockers), which appear to have various effects on cardiac electrophysiology. Special emphasis is placed on new antiarrhythmic drugs (e.g. dantrolene) targeting molecular, proarrhythmogenic and structural remodeling. Finally, new developments in the prevention of thromboembolic complications of atrial fibrillation are discussed (dabigatran).


Subject(s)
Anti-Arrhythmia Agents/therapeutic use , Arrhythmias, Cardiac/drug therapy , Drug Delivery Systems , Animals , Anti-Arrhythmia Agents/adverse effects , Anti-Arrhythmia Agents/pharmacology , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/physiopathology , Atrial Fibrillation/complications , Atrial Fibrillation/drug therapy , Atrial Fibrillation/physiopathology , Cost of Illness , Humans , Thromboembolism/etiology , Thromboembolism/prevention & control , Treatment Outcome
17.
Simul Healthc ; 3(4): 242-6, 2008.
Article in English | MEDLINE | ID: mdl-19088669

ABSTRACT

The virtual reality coronary angiography simulator "CATHI" (Catheter Instruction System, Mannheim, Germany) simulates coronary arteries with implemented vessel lesions in virtual patients. Like similar systems the software model runs on common PC systems, which are linked to the mechanical device for manual training. We combined the advantages of this skill trainer with the near to reality assembly of a cardiac catheterization laboratory (Cath-lab) by connecting it to a full scale simulator (HPS, METI, Sarasota, FL). We present two methods of synchronizing the heartbeat between both simulation devices. Method A-the hardware solution-uses the electrocardiogram-synchronization signal of the HPS as a pacemaker for CATHI's heartbeat. Method B, a more sophisticated software solution, uses a communication protocol between the HPS software and the CATHI system to realize bi-directional data exchange. In 14 identical courses we performed four different scenarios using the above described setup, all of which had to be undergone by the 143 participants (including nursing staff, experienced- and inexperienced cardiologists). The synchronization of the two systems contributed to a close to reality situation. Scenario control was accomplished via commercially available HPS-software. Tachycardic and bradycardic arrhythmias were predetermined by predefined scenarios of the HPS-software, the trainee's intervention resulting in realistic treatment outcomes. Using either method, the transmitted signals resulted in the same heartbeat in the CATHI-system, making the cardiologic interventions more difficult but more realistic.


Subject(s)
Angioplasty, Balloon, Coronary/education , Computer Simulation , Coronary Angiography/instrumentation , Health Personnel/education , Patient Simulation , Teaching , User-Computer Interface , Cardiology/education , Coronary Artery Disease/therapy , Education, Medical, Continuing , Humans , Software
18.
Antioxid Redox Signal ; 10(8): 1435-47, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18522491

ABSTRACT

Chronic nitroglycerin treatment results in development of nitrate tolerance associated with endothelial dysfunction (ED). We sought to clarify how mitochondria- and NADPH oxidase (Nox)-derived reactive oxygen species (ROS) contribute to nitrate tolerance and nitroglycerin-induced ED. Nitrate tolerance was induced by nitroglycerin infusion in male Wistar rats (100 microg/h/4 day) and in C57/Bl6, p47(phox/) and gp91(phox/) mice (50 microg/h/4 day). Protein and mRNA expression of Nox subunits were unaltered by chronic nitroglycerin treatment. Oxidative stress was determined in vascular rings and mitochondrial fractions of nitroglycerin-treated animals by L-012 enhanced chemiluminescence, revealing a dominant role of mitochondria for nitrate tolerance development. Isometric tension studies revealed that genetic deletion or inhibition (apocynin, 0.35 mg/h/4 day) of Nox improved ED, whereas nitrate tolerance was unaltered. Vice versa, nitrate tolerance was attenuated by co-treatment with the respiratory chain complex I inhibitor rotenone (100 microg/h/4 day) or the mitochondrial permeability transition pore blocker cyclosporine A (50 microg/h/4 day). Both compounds improved ED, suggesting a link between mitochondrial and Nox-derived ROS. Mitochondrial respiratory chain-derived ROS are critical for the development of nitrate tolerance, whereas Nox-derived ROS mediate nitrate tolerance-associated ED. This suggests a crosstalk between mitochondrial and Nox-derived ROS with distinct mechanistic effects and sites for pharmacological intervention.


Subject(s)
Aorta/drug effects , NADPH Oxidases/metabolism , Nitroglycerin/pharmacology , Reactive Oxygen Species/metabolism , Animals , Aorta/metabolism , Aorta/physiopathology , Blotting, Western , Cell Line , Chromatography, High Pressure Liquid , Cyclosporine/administration & dosage , Cyclosporine/pharmacology , Ethidium/analogs & derivatives , Ethidium/metabolism , Humans , In Vitro Techniques , Male , Mice , Mice, Inbred C57BL , Mitochondria, Heart/drug effects , Mitochondria, Heart/metabolism , NADPH Oxidases/genetics , Nitroglycerin/administration & dosage , RNA, Messenger/genetics , RNA, Messenger/metabolism , Rats , Rats, Wistar , Reactive Nitrogen Species/metabolism , Reverse Transcriptase Polymerase Chain Reaction , Rotenone/administration & dosage , Rotenone/pharmacology , Transfection , Vasoconstriction/drug effects , Vasodilator Agents/administration & dosage , Vasodilator Agents/pharmacology
19.
J Am Coll Cardiol ; 50(23): 2226-32, 2007 Dec 04.
Article in English | MEDLINE | ID: mdl-18061070

ABSTRACT

OBJECTIVES: We tested the hypothesis of whether an inhibition of the nitroglycerin (GTN) bioactivating enzyme mitochondrial aldehyde dehydrogenase (ALDH-2) contributes to GTN tolerance in human blood vessels. BACKGROUND: The hemodynamic effects of GTN are rapidly blunted by the development of tolerance, a phenomenon associated with increased formation of reactive oxygen species (ROS). Recent studies suggest that ROS-induced inhibition of ALDH-2 accounts for tolerance in animal models. METHODS: Segments of surgically removed arteria mammaria and vena saphena from patients undergoing coronary bypass surgery were used to examine the vascular responsiveness to GTN and the endothelium-dependent vasodilator acetylcholine. The ALDH-2 activity and expression in these segments were assessed by the conversion of a benzaldehyde or its derivative to the benzoic acid metabolite and by Western blotting technique. RESULTS: In contrast to patients not treated with nitrates (n = 36), patients treated with GTN for 48 h (n = 14) before surgery showed tolerance to GTN and endothelial dysfunction in arterial and venous vessels. In vivo GTN tolerance was mimicked in vitro by incubation of nontolerant vessels with the ALDH-2 inhibitor benomyl. In vivo GTN treatment decreased vascular aldehyde dehydrogenase activity compared with nontolerant vessels and decreased the expression of ALDH-2 in arterial tissue. Incubation of control venous vessels with GTN caused a significant attenuation of aldehyde dehydrogenase activity that was reversed by presence of the sulfhydryl group donor dithiothreitol. CONCLUSIONS: Long-term GTN treatment induces tolerance and endothelial dysfunction in human vessels, associated with an inhibition and down-regulation of vascular ALDH-2. Thus, these findings extend results of previous animal studies to humans.


Subject(s)
Aldehyde Dehydrogenase/metabolism , Drug Tolerance/physiology , Mammary Arteries/drug effects , Myocardial Infarction/enzymology , Nitroglycerin/pharmacology , Saphenous Vein/drug effects , Acetylcholine/pharmacology , Aged , Aldehyde Dehydrogenase, Mitochondrial , Drug Administration Schedule , Female , Humans , Male , Mammary Arteries/enzymology , Mammary Arteries/physiopathology , Myocardial Infarction/physiopathology , Myocardial Infarction/therapy , Nitric Oxide Synthase Type III/metabolism , Nitroglycerin/administration & dosage , Oxidative Stress/physiology , Saphenous Vein/enzymology , Saphenous Vein/physiopathology , Tissue Culture Techniques , Vasodilator Agents/pharmacology
20.
Arterioscler Thromb Vasc Biol ; 27(8): 1729-35, 2007 Aug.
Article in English | MEDLINE | ID: mdl-17541025

ABSTRACT

OBJECTIVE: Nitrate tolerance is likely attributable to an increased production of reactive oxygen species (ROS) leading to an inhibition of the mitochondrial aldehyde dehydrogenase (ALDH-2), representing the nitroglycerin (GTN) and pentaerythrityl tetranitrate (PETN) bioactivating enzyme, and to impaired nitric oxide bioactivity and signaling. We tested whether differences in their capacity to induce heme oxygenase-1 (HO-1) might explain why PETN and not GTN therapy is devoid of nitrate and cross-tolerance. METHODS AND RESULTS: Wistar rats were treated with PETN or GTN (10.5 or 6.6 microg/kg/min for 4 days). In contrast to GTN, PETN did not induce nitrate tolerance or cross-tolerance as assessed by isometric tension recordings in isolated aortic rings. Vascular protein and mRNA expression of HO-1 and ferritin were increased in response to PETN but not GTN. In contrast to GTN therapy, NO signaling, ROS formation, and the activity of ALDH-2 (as assessed by an high-performance liquid chromatography-based method) were not significantly influenced by PETN. Inhibition of HO-1 expression by apigenin induced "tolerance" to PETN whereas HO-1 gene induction by hemin prevented tolerance in GTN treated rats. CONCLUSIONS: HO-1 expression and activity appear to play a key role in the development of nitrate tolerance and might represent an intrinsic antioxidative mechanism of therapeutic interest.


Subject(s)
Drug Tolerance , Heme Oxygenase-1/metabolism , Nitroglycerin/pharmacology , Pentaerythritol Tetranitrate/pharmacology , Aldehyde Dehydrogenase/metabolism , Animals , Chromatography, High Pressure Liquid , Cyclic GMP/metabolism , Disease Models, Animal , Endothelium, Vascular/drug effects , Free Radical Scavengers , Heme Oxygenase-1/drug effects , Male , Nitroglycerin/metabolism , Pentaerythritol Tetranitrate/metabolism , Probability , Random Allocation , Rats , Rats, Wistar , Reactive Oxygen Species , Reference Values , Sensitivity and Specificity
SELECTION OF CITATIONS