1.
J Appl Clin Med Phys ; 21(4): 6-12, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32039544

ABSTRACT

Cone-beam CT-guided single dose of lung stereotactic body radiotherapy (SBRT) treatment with a flattening filter free (FFF) beam and volumetric modulated arc therapy (VMAT) is a safe and highly effective treatment modality for selective small lung lesions. Four-dimensional (4D) CT-based treatment plans were generated using advanced AcurosXB algorithm for heterogeneity corrections. 6X-FFF beam produced highly conformal radiosurgical dose distribution to the target and reduced lung SBRT fraction duration to less than 10 min for a single dose of 30 Gy, significantly improving patient comfort and clinic workflow. Early follow-up CT imaging results (mean, 8 months) show high local control rates (100%) with no acute lung or rib toxicity. Longer clinical follow-up in a larger patient cohort managed in this fashion is underway to further validate this treatment approach.


Subject(s)
Carcinoma, Non-Small-Cell Lung/radiotherapy , Cone-Beam Computed Tomography/methods , Four-Dimensional Computed Tomography/methods , Lung Neoplasms/radiotherapy , Radiosurgery/methods , Radiotherapy, Intensity-Modulated/methods , Algorithms , Follow-Up Studies , Humans , Radiometry , Radiosurgery/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/instrumentation
2.
Brachytherapy ; 18(5): 683-688, 2019.
Article in English | MEDLINE | ID: mdl-31248823

ABSTRACT

PURPOSE: The CivaSheet device uses multiple directionally shielded Pd-103 CivaDot sources to produce a directional planar dose distribution. In postplanning, manually digitizing the 3D source orientation is challenging because the 3D vector must be digitized by using 2D displayed images. The aim of this study is to develop an algorithm that will automatically determine the direction of each CivaDot source based on the location of sources adjacent to it. METHODS AND MATERIALS: The algorithm determines the source direction by averaging the normal directions of multiple local planes established by the adjacent sources. The algorithm was tested on a manually constructed CivaSheet-like device that was CT scanned in known flat geometries and two known curved geometries. Algorithmically determined source directions were compared with the known directions. The algorithm was also used on a postplan for a gynecological pelvic sidewall tumor bed implant and compared against manual digitization of the source directions. RESULTS: For the flat and curved test geometries, the average angular difference between the algorithm determined and known orientation was 1.2° ± 0.8° (flat geometry), 1.7° ± 2.1° (curve about vertical axis), and 2.3° ± 2.4° (curve about horizontal axis). For the patient case, results showed on average a 23.1° ± 10.8° difference between the manual digitized orientation and the algorithm's predicted orientation. CONCLUSIONS: The algorithm calculates the source orientation with accuracy better than 2.3° for the controlled experiments. In addition to its accuracy, the algorithm produces consistent results and lessens the difficult challenge of orienting the partially shielded sources.


Subject(s)
Algorithms , Brachytherapy/instrumentation , Brachytherapy/methods , Palladium/therapeutic use , Radioisotopes/therapeutic use , Brachytherapy/adverse effects , Female , Humans , Pelvic Neoplasms/diagnostic imaging , Pelvic Neoplasms/radiotherapy , Phantoms, Imaging , Prostheses and Implants , Radiation Injuries/etiology , Radiation Injuries/prevention & control , Radiotherapy Planning, Computer-Assisted/methods , Tomography, X-Ray Computed/methods
3.
J Appl Clin Med Phys ; 20(5): 55-63, 2019 May.
Article in English | MEDLINE | ID: mdl-30955251

ABSTRACT

PURPOSE/OBJECTIVES: Due to higher radiosensitivity, non-target normal tissue dose is a major concern in stereotactic body radiation therapy (SBRT) treatment. The aim of this report was to estimate the dosimetric impact, specifically the reduction of normal lung dose in the treatment of single-isocenter/two-lesion lung SBRT via volumetric modulated arc therapy with jaw tracking (JT-VMAT). MATERIALS/METHODS: Twelve patients with two peripherally located early-stage non-small-cell-lung cancer (NSCLC) lung lesions underwent single-isocenter highly conformal non-coplanar JT-VMAT SBRT treatment in our institution. The mean isocenter to tumors distance was 5.6 ± 1.9 (range 4.3-9.5) cm. The mean combined planning target volume (PTV) was 38.7 ± 22.7 (range 5.0-80.9) cc. A single isocenter was placed between the two lesions. Doses were 54 and 50 Gy in three and five fractions, respectively. Plans were optimized in Eclipse with AcurosXB algorithm utilizing jaw tracking options for the Truebeam with a 6 MV-FFF beam and standard 120 leaf millennium multi-leaf collimators. For comparison, the JT-VMAT plans were retrospectively re-computed utilizing identical beam geometry, objectives, and planning parameters, but without jaw tracking (no JT-VMAT). Both plans were normalized to receive the same target coverage. The conformity and heterogeneity indices, intermediate-dose spillage [D2cm , R50, Gradient Index (GI), Gradient Distance (GD)], organs at risks (OAR) doses including normal lung as well as modulation factor (MF) were compared for both plans. RESULTS: For similar target coverage, GI, R50, GD, as well as the normal lung V5, V10, V20, mean lung dose (MLD), and maximum dose received by 1000 cc of lungs were statistically significant. Normal lung doses were reduced by 8%-11% with JT-VMAT. Normal lung dose increased as a function of tumor distance from isocenter. For the other OAR, up to 1%-16% reduction of non-target doses were observed with JT-VMAT. The MF and beam-on time were similar for both plans, however, MF increased as a function of tumors distance, consequently, delivering higher dose to normal lungs. CONCLUSION: Utilizing jaw tracking options during optimization for single-isocenter/two-lesion lung SBRT VMAT plans reduced doses to the normal lung and other OAR, reduced intermediate-dose spillage and provided superior/similar target coverage. Application of jaw tracking did not affect delivery efficiency and provided excellent plan quality with similar MF and beam-on time. Jaw tracking is recommended for future clinical SBRT plan optimization.


Subject(s)
Carcinoma, Non-Small-Cell Lung/surgery , Jaw/physiology , Lung/radiation effects , Organs at Risk/radiation effects , Phantoms, Imaging , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Algorithms , Biomechanical Phenomena , Four-Dimensional Computed Tomography , Humans , Jaw/radiation effects , Jaw Relation Record , Lung Neoplasms/surgery , Prognosis , Radiometry/methods , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated/methods , Retrospective Studies , Tumor Burden
4.
Phys Med Biol ; 64(5): 055001, 2019 02 20.
Article in English | MEDLINE | ID: mdl-30673636

ABSTRACT

The orthovoltage x-ray energy frequently used in radiation research is prone to dosimetry errors due to insufficient backscatter conditions. In many radiobiology studies, especially for cell irradiations, precise dose calculation algorithms such as Convolution-Superposition or Monte Carlo are impractical and as such, less accurate hand calculation methods are used for dose estimation. These dose estimation methods typically assume full backscatter conditions. The purpose of this study is to demonstrate the magnitude of the dose error that results from insufficient backscatter, and to provide lookup tables to account this issue. The beam spectra of several widely used commercial systems (XRAD-225, XRAD-320, SARRP) were used in Monte Carlo (MC) simulations on a series of phantom setups to investigate the impact of varying backscatter conditions on dosimetry. The depth dose curves for different field sizes, water phantom thicknesses and beam qualities were generated. In addition, depth dependent backscatter factors for different field sizes and different beam qualities were calculated. It is demonstrated that as much as a 50% dose difference exists for different backscatter conditions at the beam qualities studied. The choice of cell dish size as well as other changes in the experiment setup can have more than 10% impact on the dose. The impact of backscatter is reduced with a decrease in field size. Further, the thickness needed to provide full backscatter can be approximated as being equal to the field size. It is imperative to ensure full backscatter conditions during system and dosimeter calibration, or to use the look-up table provided in this study.

5.
J Appl Clin Med Phys ; 20(1): 118-127, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30548205

ABSTRACT

PURPOSE/OBJECTIVES: To evaluate the plan quality and treatment delivery efficiency of single-isocenter/two-lesions volumetric modulated arc therapy (VMAT) lung stereotactic body radiation therapy (SBRT). MATERIALS/METHODS: Eight consecutive patients with two peripherally located early stage nonsmall-cell-lung cancer (NSCLC) lung lesions underwent single-isocenter highly conformal noncoplanar VMAT SBRT treatment in our institution. A single-isocenter was placed between the two lesions. Doses were 54 or 50 Gy in 3 and 5 fractions respectively. Patients were treated every other day. Plans were calculated in Eclipse with AcurosXB algorithm and normalized to at least 95% of the planning target volume (PTV) receiving 100% of the prescribed dose. For comparison, two-isocenter plans (isocenter placed centrally in each target) were retrospectively created. Conformity indices (CIs), heterogeneity index (HI), gradient index (GI), gradient distance (GD), and D2cm were calculated. The normal lung V5, V10, V20, mean lung dose (MLD) and other organs at risk (OARs) doses were evaluated. Total number of monitor units (MUs), beam-on time, and patient-specific quality assurance (QA) results were recorded. RESULTS: The mean isocenter to tumor distance was 6.7 ± 2.3 cm. The mean combined PTV was 44.0 ± 23.4 cc. There was no clinically significant difference in CI, HI, GD, GI, D2cm , and V20 including most of the OARs between single-isocenter and two-isocenter lung SBRT plans, evaluated per RTOG guidelines. However, for single-isocenter plans as the distance between the lesions increased, the V5, V10, and MLD increased, marginally. The total number of MUs and beam-on time was reduced by a factor of 1.5 for a single-isocenter plan compared to a two-isocenter plan. The single-isocenter/two-lesions VMAT lung SBRT QA plans demonstrated an accurate dose delivery of 98.1 ± 3.2% for clinical gamma passing rate of 3%/3 mm. CONCLUSION: The SBRT treatment of two peripherally located lung lesions with a centrally placed single-isocenter was dosimetrically equivalent to two-isocenter plans. Faster treatment delivery for single-isocenter treatment can improve patient compliance and reduce the amount of intrafraction motion errors for well-suited patients.


Subject(s)
Carcinoma, Non-Small-Cell Lung/surgery , Lung Neoplasms/surgery , Organs at Risk/radiation effects , Quality Control , Radiosurgery/standards , Radiotherapy Planning, Computer-Assisted/standards , Algorithms , Carcinoma, Non-Small-Cell Lung/pathology , Humans , Lung Neoplasms/pathology , Radiometry/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Retrospective Studies
7.
Med Phys ; 41(9): 092102, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25186402

ABSTRACT

PURPOSE: To investigate the influence of slot design on dose distributions and dose-volume histograms (DVHs) for the model EP917 plaque for episcleral brachytherapy. METHODS: Dimensions and orientations of the slots were measured for three model EP917 plaques and compared to data in the Plaque Simulator (PS) treatment planning software (version 5.7.6). These independently determined coordinates were incorporated into the MCNP Monte Carlo simulation environment to obtain dose from the plaques in a water environment and in a clinical environment with ocular structures. A tumor volume was simulated as 5 mm in apical height and 11 mm in basal diameter. Variations in plaque mass density and composition; slot length, width, and depth; seed positioning; and Ag-marker rod positioning were simulated to examine their influence on plaque central axis (CAX) and planar dose distributions, and DVHs. RESULTS: Seed shifts in a single slot toward the eye and shifts of the(125)I-coated Ag rod within the capsule had the greatest impact on CAX dose distribution. A shift of 0.0994 mm toward the eye increased dose by 14%, 9%, 4.3%, and 2.7% at 1, 2, 5, and 10 mm, respectively, from the inner sclera. When examining the fully-modeled plaque in the ocular geometry, the largest dose variations were caused by shifting the Ag rods toward the sclera and shifting the seeds away from the globe when the slots were made 0.51 mm deeper, causing +34.3% and -69.4% dose changes to the outer sclera, respectively. At points along the CAX, dose from the full plaque geometry using the measured slot design was 2.4%±1.1% higher than the manufacturer-provided slot design and 2.2%±2.3% higher than the homogeneous calculation of PS treatment planning results. The ratio of D10 values for the measured slot design to the D10 values for the manufacturer-provided slot design was higher by 9%, 10%, and 19% for the tumor, inner sclera, and outer sclera, respectively. In comparison to the measured slot design, a theoretical plaque having narrower and deeper slots delivered 30%, 37%, and 62% lower D10 doses to the tumor, inner sclera, and outer sclera, respectively. CONCLUSIONS: While the measured positions of the slots on the model EP917 plaque were in close agreement (<0.7 mm) with the PS values, small differences in the slot shape caused substantial differences in dose distributions and DVH metrics. Increasing slot depth by 0.1 mm decreased outer scleral dose by 20%, yet shifting the Ag rods in the seeds toward the globe by 0.1 mm increased outer scleral dose by 35%. The clinical medical physicist is advised to measure these types of plaques upon acceptance testing before clinical use to inspect slot shape and position for comparison with data used for treatment planning purposes.


Subject(s)
Brachytherapy/instrumentation , Eye Neoplasms/radiotherapy , Brachytherapy/methods , Computer Simulation , Equipment Design , Monte Carlo Method , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Sclera/radiation effects , Software , Water
8.
Med Phys ; 41(2): 021702, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24506593

ABSTRACT

PURPOSE: To investigate potential causes for differences in TG-43 brachytherapy dosimetry parameters in the existent literature for the model IAI-125A(125)I seed and to propose new standard dosimetry parameters. METHODS: The MCNP5 code was used for Monte Carlo (MC) simulations. Sensitivity of dose distributions, and subsequently TG-43 dosimetry parameters, was explored to reproduce historical methods upon which American Association of Physicists in Medicine (AAPM) consensus data are based. Twelve simulation conditions varying(125)I coating thickness, coating mass density, photon interaction cross-section library, and photon emission spectrum were examined. RESULTS: Varying(125)I coating thickness, coating mass density, photon cross-section library, and photon emission spectrum for the model IAI-125A seed changed the dose-rate constant by up to 0.9%, about 1%, about 3%, and 3%, respectively, in comparison to the proposed standard value of 0.922 cGy h(-1) U(-1). The dose-rate constant values by Solberg et al. ["Dosimetric parameters of three new solid core (125)I brachytherapy sources," J. Appl. Clin. Med. Phys. 3, 119-134 (2002)], Meigooni et al. ["Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGE™ (125)I brachytherapy source," Med. Phys. 29, 2152-2158 (2002)], and Taylor and Rogers ["An EGSnrc Monte Carlo-calculated database of TG-43 parameters," Med. Phys. 35, 4228-4241 (2008)] for the model IAI-125A seed and Kennedy et al. ["Experimental and Monte Carlo determination of the TG-43 dosimetric parameters for the model 9011 THINSeed™ brachytherapy source," Med. Phys. 37, 1681-1688 (2010)] for the model 6711 seed were +4.3% (0.962 cGy h(-1) U(-1)), +6.2% (0.98 cGy h(-1) U(-1)), +0.3% (0.925 cGy h(-1) U(-1)), and -0.2% (0.921 cGy h(-1) U(-1)), respectively, in comparison to the proposed standard value. Differences in the radial dose functions between the current study and both Solberg et al. and Meigooni et al. were <10% for r ≤ 5 cm, and increased for r > 5 cm with a maximum difference of 29% at r = 9 cm. In comparison to Taylor and Rogers, these differences were lower (maximum of 2% at r = 9 cm). For the similarly designed model 6711 (125)I seed, differences did not exceed 0.5% for 0.5 ≤ r ≤ 10 cm. Radial dose function values varied by 1% as coating thickness and coating density were changed. Varying the cross-section library and source spectrum altered the radial dose function by 25% and 12%, respectively, but these differences occurred at r = 10 cm where the dose rates were very low. The 2D anisotropy function results were most similar to those of Solberg et al. and most different to those of Meigooni et al. The observed order of simulation condition variables from most to least important for influencing the 2D anisotropy function was spectrum, coating thickness, coating density, and cross-section library. CONCLUSIONS: Several MC radiation transport codes are available for calculation of the TG-43 dosimetry parameters for brachytherapy seeds. The physics models in these codes and their related cross-section libraries have been updated and improved since publication of the 2007 AAPM TG-43U1S1 report. Results using modern data indicated statistically significant differences in these dosimetry parameters in comparison to data recommended in the TG-43U1S1 report. Therefore, it seems that professional societies such as the AAPM should consider reevaluating the consensus data for this and others seeds and establishing a process of regular evaluations in which consensus data are based upon methods that remain state-of-the-art.


Subject(s)
Consensus , Monte Carlo Method , Radiometry/methods , Societies, Scientific , Iodine Radioisotopes/therapeutic use , Uncertainty
9.
Med Phys ; 41(2): 024101, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24506655

ABSTRACT

PURPOSE: The current widely used biological equivalent dose (BED) formalism for permanent implants is based on the linear-quadratic model that includes cell repair and repopulation but not resensitization (redistribution and reoxygenation). The authors propose a BED formalism that includes all the four biological effects (4Rs), and the authors propose how it can be used to calculate appropriate prescription doses for permanent implants with Cs-131. METHODS: A resensitization correction was added to the BED calculation for permanent implants to account for 4Rs. Using the same BED, the prescription doses with Au-198, I-125, and Pd-103 were converted to the isoeffective Cs-131 prescription doses. The conversion factor F, ratio of the Cs-131 dose to the equivalent dose with the other reference isotope (Fr: with resensitization, Fn: without resensitization), was thus derived and used for actual prescription. Different values of biological parameters such as α, ß, and relative biological effectiveness for different types of tumors were used for the calculation. RESULTS: Prescription doses with I-125, Pd-103, and Au-198 ranging from 10 to 160 Gy were converted into prescription doses with Cs-131. The difference in dose conversion factors with (Fr) and without (Fn) resensitization was significant but varied with different isotopes and different types of tumors. The conversion factors also varied with different doses. For I-125, the average values of Fr/Fn were 0.51/0.46, for fast growing tumors, and 0.88/0.77 for slow growing tumors. For Pd-103, the average values of Fr/Fn were 1.25/1.15 for fast growing tumors, and 1.28/1.22 for slow growing tumors. For Au-198, the average values of Fr/Fn were 1.08/1.25 for fast growing tumors, and 1.00/1.06 for slow growing tumors. Using the biological parameters for the HeLa/C4-I cells, the averaged value of Fr was 1.07/1.11 (rounded to 1.1), and the averaged value of Fn was 1.75/1.18. Fr of 1.1 has been applied to gynecological cancer implants with expected acute reactions and outcomes as expected based on extensive experience with permanent implants. The calculation also gave the average Cs-131 dose of 126 Gy converted from the I-125 dose of 144 Gy for prostate implants. CONCLUSIONS: Inclusion of an allowance for resensitization led to significant dose corrections for Cs-131 permanent implants, and should be applied to prescription dose calculation. The adjustment of the Cs-131 prescription doses with resensitization correction for gynecological permanent implants was consistent with clinical experience and observations. However, the Cs-131 prescription doses converted from other implant doses can be further adjusted based on new experimental results, clinical observations, and clinical outcomes.


Subject(s)
Brachytherapy/methods , Drug Prescriptions , Prostheses and Implants , Radiation Dosage , Radiation Tolerance/radiation effects , Cesium Radioisotopes/therapeutic use , Humans , Relative Biological Effectiveness
10.
J Appl Clin Med Phys ; 14(5): 104-14, 2013 Sep 06.
Article in English | MEDLINE | ID: mdl-24036863

ABSTRACT

The feasibility of delivering craniospinal irradiation (CSI) with TomoDirect is investigated. A method is proposed to generate TomoDirect plans using standard three-dimensional (3D) beam arrangements on Tomotherapy with junctioning of these fields to minimize hot or cold spots at the cranial/spinal junction. These plans are evaluated and compared to a helical Tomotherapy and a three-dimensional conformal therapy (3D CRT) plan delivered on a conventional linear accelerator (linac) for CSI. The comparison shows that a TomoDirect plan with an overlap between the cranial and spinal fields might be preferable over Tomotherapy plans because of decreased low dose to large volumes of normal tissues outside of the planning target volume (PTV). Although the TomoDirect plans were not dosimetrically superior to a 3D CRT linac plan, the patient can be easily treated in the supine position, which is often more comfortable and efficient from an anesthesia standpoint. TomoDirect plans also have only one setup position which obviates the need for matching of fields and feathering of junctions, two issues encountered with conventional 3D CRT plans. TomoDirect plans can be delivered with comparable treatment times to conventional 3D plans and in shorter times than a Tomotherapy plan. In this paper, a method is proposed for creating TomoDirect craniospinal plans, and the dosimetric consequences for choosing different planning parameters are discussed.


Subject(s)
Craniospinal Irradiation , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Computer Simulation , Feasibility Studies , Humans , Particle Accelerators , Radiotherapy Dosage , Retrospective Studies
11.
Med Phys ; 40(9): 091714, 2013 Sep.
Article in English | MEDLINE | ID: mdl-24007147

ABSTRACT

PURPOSE: To assess the hypothesis that the volume of whole brain that receives a certain dose level is primarily dependent on the treated volume rather than on the number, shape, or location of the lesions. This would help a physician validate the suitability of GammaKnife(®) based stereotactic radiosurgery (GKSR) prior to treatment. METHODS: Simulation studies were performed to establish the hypothesis for both oblong and spherical shaped lesions of various numbers and sizes. Forty patients who underwent GKSR [mean age of 54 years (range 7-80), mean number of lesions of 2.5 (range 1-6), and mean lesion volume of 4.4 cm(3) (range 0.02-22.2 cm(3))] were also studied retrospectively. Following recommendations of QUANTEC, the volume of brain irradiated by the 12 Gy (VB12) isodose line was measured and a power-law based relation is proposed here for estimating VB12 from the known tumor volume and the prescription dose. RESULTS: In the simulation study on oblong, spherical, and multiple lesions, the volume of brain irradiated by 50%, 10%, and 1% of maximum dose was found to have linear, linear, and exponentially increasing dependence on the volume of the treated region, respectively. In the retrospective study on 40 GKSR patients, a similar relationship was found to predict the brain dose with a Spearman correlation coefficient >0.9. In both the studies, the volume of brain irradiated by a certain dose level does not have a statistically significant relationship (p ≥ 0.05) with the number, shape, or position of the lesions. The measured VB12 agrees with calculation to within 1.7%. CONCLUSIONS: The results from the simulation and the retrospective clinical studies indicate that the volume of whole brain that receives a certain percentage of the maximum dose is primarily dependent on the treated volume and less on the number, shape, and location of the lesions.


Subject(s)
Brain Neoplasms/pathology , Brain Neoplasms/radiotherapy , Brain/radiation effects , Gamma Rays/therapeutic use , Radiation Dosage , Radiosurgery/methods , Tumor Burden , Brain/pathology , Humans
12.
Med Phys ; 40(6): 061703, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23718582

ABSTRACT

PURPOSE: Image guidance has become a standard of care for many treatment scenarios in radiation therapy. This is most typically accomplished by use of kV x-ray devices mounted onto the linear accelerator (Linac) gantry that yield planar, fluoroscopic, and cone-beam computed tomography (CBCT) images. Image acquisition parameters are chosen via preset techniques that rely on broad categorizations in patient anatomy and imaging goal. However, the optimal imaging technique results in detectability of the features of interest while exposing the patient to minimum dose. Herein, the authors present an investigation into the feasibility of developing an image planning system (IPS) for radiotherapy. METHODS: In this first phase, the authors focused on developing an algorithm to predict tissue contrast produced by a common radiotherapy planar imaging chain. Input parameters include a CT dataset and simulated planar imaging technique settings that include kV and mAs. Energy-specific attenuation through each voxel of the CT dataset was calculated in the algorithm to derive a net transmitted intensity. The response of the flat panel detector was integrated into the image simulation algorithm. Verification was conducted by comparing simulated and measured images using four phantoms. Comparisons were made in both high and low contrast settings, as well as changes in the geometric appearance due to image saturation. RESULTS: The authors studied a lung nodule test object to assess the planning system's ability to predict object contrast and detectability. Verification demonstrated that the slope of the pixel intensities is similar, the presence of the nodule is evident, and image saturation at high mAs values is evident in both images. The appearance of the lung nodule is a function of the image detector saturation. The authors assessed the dimensions of the lung nodule in measured and simulated images. Good quantitative agreement affirmed the algorithm's predictive capabilities. The invariance of contrast with kVp and mAs prior to saturation was predicted, as well as the gradual loss of object detectability as saturation was approached. Small changes in soft tissue density were studied using a mammography step wedge phantom. Data were acquired at beam qualities of 80 and 120 kVp and over exposure values ranging from 0.04 to 500 mAs. The data showed good agreement in terms of the absolute value of pixel intensities predicted, as well as small variations across the step wedge pattern. The saturation pixel intensity was consistent between the two beam qualities studied. Boney tissue contrast was assessed using two abdominal phantoms. Measured and calculated values agree in terms of predicting the mAs value at which detector saturation, and subsequent loss of contrast occurs. The lack of variation in contrast over mAs values lower than 10 suggests that there is wide latitude for minimizing patient dose. CONCLUSIONS: The authors developed and tested an algorithm that can be used to assist in kV imaging technique selection during localization for radiotherapy. Phantom testing demonstrated the algorithm's predictive accuracy for both low and high contrast imaging scenarios. Detector saturation with subsequent loss of imaging detail, both in terms of object size and contrast were accurately predicted by the algorithm.


Subject(s)
Radiation Injuries/prevention & control , Radiation Protection/methods , Radiographic Image Enhancement/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Radiotherapy, Image-Guided/methods , Tomography, X-Ray Computed/methods , Feasibility Studies , Humans , Radiation Injuries/etiology , Radiotherapy Dosage , Radiotherapy, Image-Guided/adverse effects , Reproducibility of Results , Sensitivity and Specificity
14.
Med Phys ; 38(2): 857-71, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21452723

ABSTRACT

Task Group 154 (TG154) of the American Association of Physicists in Medicine (AAPM) was created to produce a guidance document for clinical medical physicists describing recommended quality assurance (QA) procedures for ultrasound (U.S.)-guided external beam radiotherapy localization. This report describes the relevant literature, state of the art, and briefly summarizes U.S. imaging physics. Simulation, treatment planning and treatment delivery considerations are presented in order to improve consistency and accuracy. User training is emphasized in the report and recommendations regarding peer review are included. A set of thorough, yet practical, QA procedures, frequencies, and tolerances are recommended. These encompass recommendations to ensure both spatial accuracy and image quality.


Subject(s)
Physics , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Radiotherapy/standards , Research Report , Societies, Scientific , Humans , Imaging, Three-Dimensional , Lasers , Male , Patient Positioning , Phantoms, Imaging , Physics/education , Quality Control , Tomography, X-Ray Computed , Ultrasonography , United States
15.
Med Phys ; 37(11): 5568-78, 2010 Nov.
Article in English | MEDLINE | ID: mdl-21158268

ABSTRACT

PURPOSE: Improvements in delivery techniques for total body irradiation (TBI) using Tomotherapy and intensity modulated radiation therapy have been proven feasible. Despite the promise of improved dose conformality, the application of these "sequential" techniques has been hampered by concerns over dose heterogeneity to circulating blood. The present study was conducted to provide quantitative evidence regarding the potential clinical impact of this heterogeneity. METHODS: Blood perfusion was modeled analytically as possessing linear, sinusoidal motion in the craniocaudal dimension. The average perfusion period for human circulation was estimated to be approximately 78 s. Sequential treatment delivery was modeled as a Gaussian-shaped dose cloud with a 10 cm length that traversed a 183 cm patient length at a uniform speed. Total dose to circulating blood voxels was calculated via numerical integration and normalized to 2 Gy per fraction. Dose statistics and equivalent uniform dose (EUD) were calculated for relevant treatment times, radiobiological parameters, blood perfusion rates, and fractionation schemes. The model was then refined to account for random dispersion superimposed onto the underlying periodic blood flow. Finally, a fully stochastic model was developed using binomial and trinomial probability distributions. These models allowed for the analysis of nonlinear sequential treatment modalities and treatment designs that incorporate deliberate organ sparing. RESULTS: The dose received by individual blood voxels exhibited asymmetric behavior that depended on the coherence among the blood velocity, circulation phase, and the spatiotemporal characteristics of the irradiation beam. Heterogeneity increased with the perfusion period and decreased with the treatment time. Notwithstanding, heterogeneity was less than +/- 10% for perfusion periods less than 150 s. The EUD was compromised for radiosensitive cells, long perfusion periods, and short treatment times. However, the EUD was unaffected (within 10%) for perfusion periods of less than 150 s or treatment times of 20 min or greater. Treatment over six fractions improved the EUD per fraction such that all parametric combinations resulted in unaffected EUD. The stochastic models confirmed these results. CONCLUSIONS: Dose heterogeneity in circulating blood cells is clinically acceptable for typical treatment times, perfusion rates, and cell types. Development of conformal, sequential TBI treatment techniques should not be withheld based on concerns over circulating blood dose heterogeneity.


Subject(s)
Blood/radiation effects , Neoplasms/radiotherapy , Radiometry/methods , Radiotherapy, Intensity-Modulated/methods , Whole-Body Irradiation/methods , Algorithms , Dose Fractionation, Radiation , Dose-Response Relationship, Radiation , Humans , Models, Statistical , Neoplasms/blood , Normal Distribution , Perfusion , Stochastic Processes , Time Factors
16.
Radiother Oncol ; 82(2): 174-8, 2007 Feb.
Article in English | MEDLINE | ID: mdl-17275112

ABSTRACT

PURPOSES: To determine if there are clinically significant differences between the dosimetry of sinus tumors delivered by non-coplanar LINAC-based IMRT techniques and Helical Tomotherapy (HT). HT is capable of delivering highly conformal and uniform target dosimetry. However, HT lacks non-coplanar capability, which is commonly used for linear accelerator-based IMRT for nasal cavity and paranasal sinus tumors. METHODS AND MATERIALS: We selected 10 patients with representative early and advanced nasal cavity and paranasal sinus malignancies treated with a preoperative dose of 50 Gy/25 fractions without coverage of the cervical lymphatics for dosimetric comparison. Each plan was independently optimized using either Corvus inverse treatment planning system, commissioned for a Varian 2300 CD linear accelerator with 1cm multileaf collimator (MLC) leaves, or the HT inverse treatment planning system. A non-coplanar seven field technique was used in all Corvus plans with five mid-sagittal fields and two anterior oblique fields as described by Claus et al. [F. Claus, W. De Gersem, C. De Wagter, et al., An implementation strategy for IMRT of ethmoid sinus cancer and bilateral sparing of the optic pathways, Int J Radiat Oncol Biol Phys 51 (2001) 318-331], whereas only coplanar beamlets were used in HT planning. Dose plans were compared using DVHs, the minimum PTV dose to 1cm3 of the PTV, a uniformity index of planned treatment volume (PTV), and a comprehensive quality index (CQI) based on the maximum dose to optical structures, parotids and the brainstem which were deemed as the most critical adjacent structures. RESULTS: Both planning systems showed comparable PTV dose coverage, but HT had significantly higher uniformity (p<0.01) inside the PTV. The CQI for all organs at risk were equivalent except ipsilateral lenses and eyes, which received statistically lower dose from HT plans (p<0.01). CONCLUSIONS: Overall HT provided equivalent or slightly better normal structure avoidance with a more uniform PTV dose for nasal cavity and paranasal sinus cancer treatment than non-coplanar LINAC-based IMRT. The disadvantage of coplanar geometry in HT is apparently counterbalanced by the larger number of fields.


Subject(s)
Nose Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Tomography, Spiral Computed , Humans , Radiometry
17.
Phys Med Biol ; 52(2): 365-73, 2007 Jan 21.
Article in English | MEDLINE | ID: mdl-17202620

ABSTRACT

Treatment planning based on probability distribution function (PDF) of patient geometries has been shown a potential off-line strategy to incorporate organ motion, but the application of such approach highly depends upon the reproducibility of the PDF. In this paper, we investigated the dependences of the PDF reproducibility on the imaging acquisition parameters, specifically the scan time and the frame rate. Three healthy subjects underwent a continuous 5 min magnetic resonance (MR) scan in the sagittal plane with a frame rate of approximately 10 f s-1, and the experiments were repeated with an interval of 2 to 3 weeks. A total of nine pulmonary vessels from different lung regions (upper, middle and lower) were tracked and the dependences of their displacement PDF reproducibility were evaluated as a function of scan time and frame rate. As results, the PDF reproducibility error decreased with prolonged scans and appeared to approach equilibrium state in subjects 2 and 3 within the 5 min scan. The PDF accuracy increased in the power function with the increase of frame rate; however, the PDF reproducibility showed less sensitivity to frame rate presumably due to the randomness of breathing which dominates the effects. As the key component of the PDF-based treatment planning, the reproducibility of the PDF affects the dosimetric accuracy substantially. This study provides a reference for acquiring MR-based PDF of structures in the lung.


Subject(s)
Lung/pathology , Magnetic Resonance Imaging/methods , Movement , Artifacts , Humans , Image Processing, Computer-Assisted , Models, Statistical , Probability , Radiometry , Reproducibility of Results , Respiration , Respiratory Physiological Phenomena , Time Factors , Whole Body Imaging
18.
Phys Med Biol ; 52(1): 243-55, 2007 Jan 07.
Article in English | MEDLINE | ID: mdl-17183139

ABSTRACT

Helical tomotherapy (HT) can potentially be used for lung cancer treatment including stereotactic radiosurgery because of its advanced image guidance and its ability to deliver highly conformal dose distributions. However, previous theoretical and simulation studies reported that the effect of respiratory motion on statically planned tomotherapy treatments may cause substantial differences between the calculated and actual delivered radiation isodose distribution, particularly when the treatment is hypofractionated. In order to determine the dosimetric effects of motion upon actual HT treatment delivery, phantom film dosimetry measurements were performed under static and moving conditions using a clinical HT treatment unit. The motion phantom system was constructed using a programmable motor, a base, a moving platform and a life size lung heterogeneity phantom with wood inserts representing lung tissue with a 3.0 cm diameter spherical tumour density equivalent insert. In order to determine the effects of different motion and tomotherapy delivery parameters, treatment plans were created using jaw sizes of 1.04 cm and 2.47 cm, with incremental gantry rotation periods between the minimum allowed (10 s) and the maximum allowed (60 s). The couch speed varied from 0.009 cm s(-1) to 0.049 cm s(-1), and delivered to a phantom under static and dynamic conditions with peak-to-peak motion amplitudes of 1.2 cm and 2 cm and periods of 3 and 5 s to simulate human respiratory motion of lung tumours. A cylindrical clinical target volume (CTV) was contoured to tightly enclose the tumour insert. 2.0 Gy was prescribed to 95% of the CTV. Two-dimensional dose was measured by a Kodak EDR2 film. Dynamic phantom doses were then quantitatively compared to static phantom doses in terms of axial dose profiles, cumulative dose volume histograms (DVH), percentage of CTV receiving the prescription dose and the minimum dose received by 95% of the CTV. The larger motion amplitude resulted in more under-dosing at the ends of the CTV in the axis of motion, and this effect was greater for the smaller jaw size plans. Due to the size of the penumbra, the 2.47 cm jaw plans provide adequate coverage for smaller amplitudes of motion, +/-0.6 cm in our experiment, without adding any additional margin in the axis of motion to the treatment volume. The periodic heterogeneous patterns described by previous studies were not observed from the single fraction of the phantom measurement. Besides the jaw sizes, CTV dose coverage is not significantly dependent on machine and phantom motion periods. The lack of adverse synchronization patterns from both results validate that HT is a safe technique for treating moving target and hypofractionation.


Subject(s)
Motion , Phantoms, Imaging , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Respiration , Equipment Design/methods , Humans , Radiotherapy Dosage , Radiotherapy, Computer-Assisted/methods , Radiotherapy, Conformal/instrumentation , Radiotherapy, Conformal/standards , Research Design
19.
Med Phys ; 33(9): 3321-6, 2006 Sep.
Article in English | MEDLINE | ID: mdl-17022227

ABSTRACT

Lung tumor motion trajectories measured by four-dimensional CT or dynamic MRI can be converted to a probability density function (PDF), which describes the probability of the tumor at a certain position, for PDF based treatment planning. Using this method in simulated sequential tomotherapy, we study the dose reduction of normal tissues and more important, the effect of PDF reproducibility on the accuracy of dosimetry. For these purposes, realistic PDFs were obtained from two dynamic MRI scans of a healthy volunteer within a 2 week interval. The first PDF was accumulated from a 300 s scan and the second PDF was calculated from variable scan times from 5 s (one breathing cycle) to 300 s. Optimized beam fluences based on the second PDF were delivered to the hypothetical gross target volume (GTV) of a lung phantom that moved following the first PDF The reproducibility between two PDFs varied from low (78%) to high (94.8%) when the second scan time increased from 5 s to 300 s. When a highly reproducible PDF was used in optimization, the dose coverage of GTV was maintained; phantom lung receiving 10%-20% prescription dose was reduced by 40%-50% and the mean phantom lung dose was reduced by 9.6%. However, optimization based on PDF with low reproducibility resulted in a 50% underdosed GTV. The dosimetric error increased nearly exponentially as the PDF error increased. Therefore, although the dose of the tumor surrounding tissue can be theoretically reduced by PDF based treatment planning, the reliability and applicability of this method highly depend on if a reproducible PDF exists and is measurable. By correlating the dosimetric error and PDF error together, a useful guideline for PDF data acquisition and patient qualification for PDF based planning can be derived.


Subject(s)
Lung Neoplasms/diagnosis , Lung Neoplasms/radiotherapy , Magnetic Resonance Imaging , Models, Biological , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Respiratory Mechanics , Artifacts , Humans , Lung Neoplasms/physiopathology , Models, Statistical , Movement , Phantoms, Imaging , Radiotherapy Dosage , Relative Biological Effectiveness , Reproducibility of Results , Sensitivity and Specificity , Statistical Distributions
20.
Int J Radiat Oncol Biol Phys ; 65(3): 917-23, 2006 Jul 01.
Article in English | MEDLINE | ID: mdl-16751074

ABSTRACT

PURPOSE: To date, most intensity-modulated radiation therapy (IMRT) delivery has occurred using linear accelerators (linacs), although helical tomotherapy has become commercially available. To quantify the dosimetric difference, we compared linac-based and helical tomotherapy-based treatment plans for IMRT of the oropharynx. METHODS AND MATERIALS: We compared the dosimetry findings of 10 patients who had oropharyngeal carcinoma. Five patients each had cancers in the base of the tongue and tonsil. Each plan was independently optimized using either the CORVUS planning system (Nomos Corporation, Sewickly, PA), commissioned for a Varian 2300 CD linear accelerator (Varian Medical Systems, Palo Alto, CA) with 1-cm multileaf collimator leaves, or helical tomotherapy. The resulting treatment plans were evaluated by comparing the dose-volume histograms, equivalent uniform dose (EUD), dose uniformity, and normal tissue complication probabilities. RESULTS: Helical tomotherapy plans showed improvement of critical structure avoidance and target dose uniformity for all patients. The average equivalent uniform dose reduction for organs at risk (OARs) surrounding the base of tongue and the tonsil were 17.4% and 27.14% respectively. An 80% reduction in normal tissue complication probabilities for the parotid glands was observed in the tomotherapy plans relative to the linac-based plans. The standard deviation of the planning target volume dose was reduced by 71%. In our clinic, we use the combined dose-volume histograms for each class of plans as a reference goal for helical tomotherapy treatment planning optimization. CONCLUSIONS: Helical tomotherapy provides improved dose homogeneity and normal structure dose compared with linac-based IMRT in the treatment of oropharyngeal carcinoma resulting in a reduced risk for complications from focal hotspots within the planning target volume and for the adjacent parotid glands.


Subject(s)
Carcinoma, Squamous Cell/radiotherapy , Oropharyngeal Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Humans , Particle Accelerators , Radiation Injuries/prevention & control , Tomography, Spiral Computed/methods , Tonsillar Neoplasms/radiotherapy