1.
Biomed Opt Express ; 13(11): 5628-5642, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-36733737

ABSTRACT

Quantifying solid tumor margins with fluorescence-guided surgery approaches is a challenge, particularly when using near infrared (NIR) wavelengths due to increased penetration depths. An NIR dual wavelength excitation fluorescence (DWEF) approach was developed that capitalizes on the wavelength-dependent attenuation of light in tissue to determine fluorophore depth. A portable dual wavelength excitation fluorescence imaging system was built and tested in parallel with an NIR tumor-targeting fluorophore in tissue mimicking phantoms, chicken tissue, and in vivo mouse models of breast cancer. The system showed high accuracy in all experiments. The low cost and simplicity of this approach make it ideal for clinical use.

2.
Sci Rep ; 10(1): 12549, 2020 07 28.
Article in English | MEDLINE | ID: mdl-32724184

ABSTRACT

Evolution from static to dynamic label-free thermal imaging has improved bulk tissue characterization, but fails to capture subtle thermal properties in heterogeneous systems. Here, we report a label-free, high speed, and high-resolution platform technology, focal dynamic thermal imaging (FDTI), for delineating material patterns and tissue heterogeneity. Stimulation of focal regions of thermally responsive systems with a narrow beam, low power, and low cost 405 nm laser perturbs the thermal equilibrium. Capturing the dynamic response of 3D printed phantoms, ex vivo biological tissue, and in vivo mouse and rat models of cancer with a thermal camera reveals material heterogeneity and delineates diseased from healthy tissue. The intuitive and non-contact FDTI method allows for rapid interrogation of suspicious lesions and longitudinal changes in tissue heterogeneity with high-resolution and large field of view. Portable FDTI holds promise as a clinical tool for capturing subtle differences in heterogeneity between malignant, benign, and inflamed tissue.


Subject(s)
Diagnostic Imaging/methods , Neoplasms/diagnostic imaging , Phantoms, Imaging , Animals , Diagnostic Imaging/instrumentation , Female , Humans , Mice , Mice, Inbred BALB C , Neoplasms/diagnosis , Rats , Rats, Sprague-Dawley
3.
J Nucl Med ; 61(8): 1113-1122, 2020 08.
Article in English | MEDLINE | ID: mdl-32303598

ABSTRACT

Gone are the days when medical imaging was used primarily to visualize anatomic structures. The emergence of molecular imaging (MI), championed by radiolabeled 18F-FDG PET, has expanded the information content derived from imaging to include pathophysiologic and molecular processes. Cancer imaging, in particular, has leveraged advances in MI agents and technology to improve the accuracy of tumor detection, interrogate tumor heterogeneity, monitor treatment response, focus surgical resection, and enable image-guided biopsy. Surgeons are actively latching on to the incredible opportunities provided by medical imaging for preoperative planning, intraoperative guidance, and postoperative monitoring. From label-free techniques to enabling cancer-selective imaging agents, image-guided surgery provides surgical oncologists and interventional radiologists both macroscopic and microscopic views of cancer in the operating room. This review highlights the current state of MI and sensing approaches available for surgical guidance. Salient features of nuclear, optical, and multimodal approaches will be discussed, including their strengths, limitations, and clinical applications. To address the increasing complexity and diversity of methods available today, this review provides a framework to identify a contrast mechanism, suitable modality, and device. Emerging low-cost, portable, and user-friendly imaging systems make the case for adopting some of these technologies as the global standard of care in surgical practice.


Subject(s)
Molecular Imaging/methods , Neoplasms/diagnostic imaging , Neoplasms/surgery , Surgery, Computer-Assisted , Humans
4.
Ann Surg Oncol ; 24(7): 1897-1903, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28213790

ABSTRACT

BACKGROUND: The inability to visualize the patient and surgical site directly, limits the use of current near infrared fluorescence-guided surgery systems for real-time sentinel lymph node biopsy and tumor margin assessment. METHODS: We evaluated an optical see-through goggle augmented imaging and navigation system (GAINS) for near-infrared, fluorescence-guided surgery. Tumor-bearing mice injected with a near infrared cancer-targeting agent underwent fluorescence-guided, tumor resection. Female Yorkshire pigs received hind leg intradermal indocyanine green injection and underwent fluorescence-guided, popliteal lymph node resection. Four breast cancer patients received 99mTc-sulfur colloid and indocyanine green retroareolarly before undergoing sentinel lymph node biopsy using radioactive tracking and fluorescence imaging. Three other breast cancer patients received indocyanine green retroareolarly before undergoing standard-of-care partial mastectomy, followed by fluorescence imaging of resected tumor and tumor cavity for margin assessment. RESULTS: Using near-infrared fluorescence from the dyes, the optical see-through GAINS accurately identified all mouse tumors, pig lymphatics, and four pig popliteal lymph nodes with high signal-to-background ratio. In 4 human breast cancer patients, 11 sentinel lymph nodes were identified with a detection sensitivity of 86.67 ± 0.27% for radioactive tracking and 100% for GAINS. Tumor margin status was accurately predicted by GAINS in all three patients, including clear margins in patients 1 and 2 and positive margins in patient 3 as confirmed by paraffin-embedded section histopathology. CONCLUSIONS: The optical see-through GAINS prototype enhances near infrared fluorescence-guided surgery for sentinel lymph node biopsy and tumor margin assessment in breast cancer patients without disrupting the surgical workflow in the operating room.


Subject(s)
Breast Neoplasms/surgery , Eye Protective Devices , Fluorescence , Lymph Nodes/surgery , Surgery, Computer-Assisted/methods , Surgical Oncology , Adult , Aged , Animals , Breast Neoplasms/pathology , Female , Humans , Indocyanine Green , Lymph Node Excision , Lymph Nodes/pathology , Mice , Mice, Inbred BALB C , Mice, Nude , Middle Aged , Prognosis , Sentinel Lymph Node Biopsy , Swine
5.
Sci Rep ; 5: 12117, 2015 Jul 16.
Article in English | MEDLINE | ID: mdl-26179014

ABSTRACT

The inability to identify microscopic tumors and assess surgical margins in real-time during oncologic surgery leads to incomplete tumor removal, increases the chances of tumor recurrence, and necessitates costly repeat surgery. To overcome these challenges, we have developed a wearable goggle augmented imaging and navigation system (GAINS) that can provide accurate intraoperative visualization of tumors and sentinel lymph nodes in real-time without disrupting normal surgical workflow. GAINS projects both near-infrared fluorescence from tumors and the natural color images of tissue onto a head-mounted display without latency. Aided by tumor-targeted contrast agents, the system detected tumors in subcutaneous and metastatic mouse models with high accuracy (sensitivity = 100%, specificity = 98% ± 5% standard deviation). Human pilot studies in breast cancer and melanoma patients using a near-infrared dye show that the GAINS detected sentinel lymph nodes with 100% sensitivity. Clinical use of the GAINS to guide tumor resection and sentinel lymph node mapping promises to improve surgical outcomes, reduce rates of repeat surgery, and improve the accuracy of cancer staging.


Subject(s)
Neoplasms, Experimental/pathology , Neoplasms, Experimental/surgery , Sentinel Lymph Node Biopsy , Vision, Binocular , Animals , Fluorescence , Indocyanine Green , Mice , Mice, Nude
6.
J Biomed Opt ; 20(1): 016018, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25607724

ABSTRACT

Near infrared (NIR) fluorescence imaging has shown great potential for various clinical procedures, including intraoperative image guidance. However, existing NIR fluorescence imaging systems either have a large footprint or are handheld, which limits their usage in intraoperative applications. We present a compact NIR fluorescence imaging system (NFIS) with an image overlay solution based on threshold detection, which can be easily integrated with a goggle display system for intraoperative guidance. The proposed NFIS achieves compactness, light weight, hands-free operation, high-precision superimposition, and a real-time frame rate. In addition, the miniature and ultra-lightweight light-emitting diode tracking pod is easy to incorporate with NIR fluorescence imaging. Based on experimental evaluation, the proposed NFIS solution has a lower detection limit of 25 nM of indocyanine green at 27 fps and realizes a highly precise image overlay of NIR and visible images of mice in vivo. The overlay error is limited within a 2-mm scale at a 65-cm working distance, which is highly reliable for clinical study and surgical use.


Subject(s)
Image Processing, Computer-Assisted/instrumentation , Optical Imaging/methods , Spectroscopy, Near-Infrared/instrumentation , Surgery, Computer-Assisted/instrumentation , Algorithms , Animals , Equipment Design , Eyeglasses , Indocyanine Green , Mice, Inbred BALB C , Semiconductors
7.
Adv Cancer Res ; 124: 171-211, 2014.
Article in English | MEDLINE | ID: mdl-25287689

ABSTRACT

Medical imaging plays a critical role in cancer diagnosis and planning. Many of these patients rely on surgical intervention for curative outcomes. This requires a careful identification of the primary and microscopic tumors, and the complete removal of cancer. Although there have been efforts to adapt traditional-imaging modalities for intraoperative image guidance, they suffer from several constraints such as large hardware footprint, high-operation cost, and disruption of the surgical workflow. Because of the ease of image acquisition, relatively low-cost devices and intuitive operation, optical imaging methods have received tremendous interests for use in real-time image-guided surgery. To improve imaging depth under low interference by tissue autofluorescence, many of these applications utilize light in the near-infrared (NIR) wavelengths, which is invisible to human eyes. With the availability of a wide selection of tumor-avid contrast agents, advancements in imaging sensors, electronic and optical designs, surgeons are able to combine different attributes of NIR optical imaging techniques to improve treatment outcomes. The emergence of diverse commercial and experimental image guidance systems, which are in various stages of clinical translation, attests to the potential high impact of intraoperative optical imaging methods to improve speed of oncologic surgery with high accuracy and minimal margin positivity.


Subject(s)
Fluorescence , Neoplasms/surgery , Surgery, Computer-Assisted/methods , Animals , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...