1.
J Vasc Access ; 7(2): 60-5, 2006.
Article in English | MEDLINE | ID: mdl-16868898

ABSTRACT

The ideal dialysis access ensures adequate blood flow for dialysis, has a long life, and is associated with a low complication rate. Although no current type of access fulfills all these criteria, the native arteriovenous fistula (AVF) is close to doing so. Unfortunately, various kinds of vascular access (VA) are becoming more and more necessary to enable hemodialysis (HD). The central venous catheter (CVC), which is associated with higher morbidity and mortality, could be the only viable option to maintain permanent VA. We report an unusual complication in a patient, a 74-year-old female, who had been undergoing HD via a CVC for 14 yrs. A polyurethane CVC with a double lumen was inserted into the right internal jugular vein because an AVF was not feasible, and a polytetrafluoroethylene (PTFE) prosthesis was obstructed. In 2003, the CVC was removed due to stenosis and occlusion of the superior vena cava. A new CVC, also made of polyurethane and with a double lumen, was inserted into the left femoral vein. In January 2005, the patient reported a small rupture of about 3-4 mm located under the cuff of the CVC. For this reason, the left femoral vein had to be used, replacing the Optiflow one with a 40-cm long Tesio CVC, and the second catheter was inserted into the right femoral artery by conventional surgery. After 10 months, the patient returned once more, after the CVC in the left femoral vein had been removed because of malfunction and that the at-tempts to cannulate the same vein again had failed. Currently, two 70-cm long Tesio catheters implanted in the right femoral vein (whose tips almost reach the diaphragm) are used for dialysis sessions. The number of CVC implants has progressively increased amongst HD patients who are elderly, diabetic or who have been on long-term HD. The patient described in this case report is currently using a 70-cm long double Tesio catheter (single Tesio CVC in SPI silicon) placed in the right femoral vein. She has resumed therapy with dicumarol anticoagulants, maintaining INR within the 2.5-3.5 range. In conclusion, both the increase in the use of venous catheters for HD and in the survival of dialysis patients contribute towards the observation of rare complications associated with CVC use.


Subject(s)
Catheterization, Central Venous/adverse effects , Catheters, Indwelling , Polycystic Kidney Diseases/therapy , Renal Dialysis , Thrombosis/etiology , Aged , Equipment Failure , Female , Femoral Vein , Humans , Jugular Veins , Renal Dialysis/methods , Time Factors
2.
Radiol Med ; 99(3): 169-73, 2000 Mar.
Article in Italian | MEDLINE | ID: mdl-10879165

ABSTRACT

INTRODUCTION: Liver is the most common site of extraintestinal amebiasis and hepatic abscesses are the most frequent symptom, occurring in 3-9% of patients with amebic infection. Several studies have shown that drug treatment is more efficacious when combined with percutaneous drainage of the abscess, yielding quicker recovery and a positive body response. We report our US and CT findings in 16 patients with amebic abscesses, 12 of whom lived in a temperate peripheral area north-east of Naples. All patients had a clinical-diagnostic condition that we called "suburban amebiasis". Finally we report our personal experience with the US-guided therapeutic drainage of amebic abscesses with repeated cavity washings, which is important for positive parasitology. MATERIAL AND METHODS: We retrospectively reviewed the findings of 16 patients (11 men and 5 women; age range 36-78 years; mean 52) with amebic abscesses of liver examined with US and CT. US with a 3.5 MHz transducer was the technique of choice in all patients. 94% of liver abscesses and some extraintestinal complications were easily shown with this technique. CT angiography was then performed to detail and clarify US findings. Abscesses over 4 cm in diameter were submitted to US-guided percutaneous treatment which permitted abscess drainage, the collection of material for parasitology and repeated cavity washings. RESULTS: US showed multiple liver abscesses in 12 patients, which were multiseptate and formed by multiple hypo-/hyperechoic microabscesses in 4 of them. Four non-European patients had a single abscess, which is typical of tropical endemic forms. CT showed the amebic abscesses as hypodense roundish masses with clear-cut outline most often localized in the right lobe in the 12 multiple cases. After percutaneous drainage 13/16 patients (81%) reported less pain in the right hypochondrium and had a lower temperature; their hospitalization was also shorter. DISCUSSION AND CONCLUSIONS: Combined US and CT assessment facilitated the diagnosis of amebiasis and its differentiation from pyogenic abscess and hepatoma. The combination of US-guided drainage and drug treatment provides better results than either treatment alone and quicker improvement of patient conditions, with fewer extraintestinal complications. Percutaneous drainage should be used in abscesses bigger than 4-5 cm, those with questionable clinical-laboratory findings and finally those failing to respond to drug treatment alone. Positive parasitology of abscess content is related to repeated cavity washings after percutaneous drainage, likely because peripheral layers are much richer in amebae.


Subject(s)
Liver Abscess, Amebic/diagnosis , Suburban Population , Tomography, X-Ray Computed , Adult , Aged , Contrast Media , Drainage/methods , Female , Humans , Italy , Liver/diagnostic imaging , Liver Abscess, Amebic/therapy , Male , Middle Aged , Retrospective Studies , Therapeutic Irrigation/methods , Tomography, X-Ray Computed/methods , Ultrasonography, Interventional/methods