Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Ann Cardiol Angeiol (Paris) ; 69(2): 86-92, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32241522

ABSTRACT

BACKGROUND: Hybrid ablation for the treatment of atrial fibrillation is a single combined procedure consisting in a minimally thoracoscopic surgical ablation followed by a catheter ablation. This promising technique is recommended in persistent atrial fibrillation according to the current guidelines but is not routinely performed in France, mainly due to the absence of reimbursement by the French National Health Insurance. AIMS: The aim of this prospective and single-centre study was to analyse, for the first time in France, the feasibility, efficacy and complication rates of hybrid ablation in patients with persistent atrial fibrillation. METHODS: Hybrid ablation was performed in 15 consecutive patients (13 men, mean age 61±6 years) with persistent (7 patients) or long standing persistent (8 patients) atrial fibrillation. RESULTS: Hybrid ablation was completed in 14/15 patients. Eleven patients returned in sinus rhythm during the procedure. Two patients (13%) had major per-procedural complications and 2 had minor complications. During an average follow-up of 25±6 months, 6 patients (40%) underwent a redo catheter ablation because of atrial tachycardia, mainly peri-mitral atrial flutter. At 1 year follow up, 14/15 patients were in sinus rhythm, including 11 free of antiarrhythmic drugs.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Thoracoscopy , Aged , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/drug therapy , Catheter Ablation/adverse effects , Catheter Ablation/statistics & numerical data , Combined Modality Therapy/adverse effects , Combined Modality Therapy/methods , Feasibility Studies , Female , France , Humans , Male , Middle Aged , Postoperative Complications , Prospective Studies , Reoperation , Thoracoscopy/adverse effects , Thoracoscopy/statistics & numerical data
2.
Ann Nucl Med ; 31(3): 218-226, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28197975

ABSTRACT

BACKGROUND: Cardiac resynchronization therapy (CRT) reduces morbidity and mortality in chronic systolic heart failure. About 20% of implanted patients are considered as "non-responders". This study aimed to evaluate gated myocardial perfusion single-photon emission computed tomography (GMPS) phase parameters as compared to echocardiography in the assessment of predictors for response to CRT before and after CRT activation. METHODS: Forty-two patients were prospectively included during 15 months. A single injection of 99mTc-tetrofosmin was used to acquire GMPS phase pre- and post-CRT activation. Indicators of positive CRT response were improvement of functional status and 15% reduction in left ventricular end-systolic volume at 3 months. RESULTS: Phase parameters at baseline were similar in the two groups with no influence of perfusion data. Phase parameters after CRT activation were significantly improved in the responders' group (Δ Bandwidth -19° ± 24° vs. 13° ± 31°, p = 0.001; Δ SD -20° ± 30° vs. 26° ± 46°, p = 0.001; Δ Entropy -11 ± 12 vs. 2 ± 6%, p = 0.001). Feasibility and reproducibility were higher for GMPS. CONCLUSION: Acute phase modifications after CRT activation may predict response to CRT immediately after implantation, but not at baseline, even when adjusted to perfusion data.


Subject(s)
Cardiac Resynchronization Therapy/methods , Echocardiography , Myocardial Perfusion Imaging , Tomography, Emission-Computed, Single-Photon , Aged , Female , Heart Failure/diagnostic imaging , Heart Ventricles/diagnostic imaging , Humans , Male , Middle Aged , Observer Variation , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity , Software , Systole/drug effects , Technetium/chemistry , Treatment Outcome
3.
J Electrocardiol ; 49(4): 522-9, 2016.
Article in English | MEDLINE | ID: mdl-27199031

ABSTRACT

INTRODUCTION: The incidence of pacemaker-mediated tachycardia (PMT) varies as a function of patient characteristics, device programming and algorithm specificities. We investigated the efficacy of the Boston Scientific algorithm by reviewing PMT episodes in a large device population. METHODS: In this multicenter study, we included 328 patients implanted with a Boston Scientific device: 157 non-dependent patients with RYTHMIQ™ activated (RYTHMIQ group), 76 patients with permanent AV-conduction disorder (AV-block group) and 95 Cardiac Resynchronization Therapy patients (CRT group). For each patient, we reviewed the last 10 remote monitoring-transmitted EGMs diagnosed as PMT. RESULTS: We analyzed 784 PMT episodes across 118 patients. In the RYTHMIQ group, the diagnosis of PMT was correct in most episodes (80%) of which 69% was directly related to the prolongation of the AV-delay associated with the RYTHMIQ algorithm. The usual triggers for PMT were also observed (PVC 16%, PAC 9%). The remainder of the episodes (20%) in RYTHMIQ patients and most episodes of AV-block (66%) and CRT patients (74%) were incorrectly diagnosed as PMT during sinus tachycardia at the maximal tracking rate. The inappropriate intervention of the algorithm during exercise causes non-conducted P-waves, loss of CRT (sustained in six patients) and may have been pro-arrhythmogenic in one patient (induction of ventricular tachycardia). CONCLUSION: Algorithms to minimize ventricular pacing can occasionally have unintended consequences such as PMT. The PMT algorithm in Boston Scientific devices is associated with a high rate of incorrect PMT diagnosis during exercise resulting in inappropriate therapy with non-conducted P-waves, loss of CRT and limited risk of pro-arrhythmic events.


Subject(s)
Algorithms , Diagnosis, Computer-Assisted/instrumentation , Electrocardiography/instrumentation , Pacemaker, Artificial/statistics & numerical data , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/prevention & control , Therapy, Computer-Assisted/instrumentation , Adult , Aged , Aged, 80 and over , Diagnosis, Computer-Assisted/statistics & numerical data , Electrocardiography/statistics & numerical data , Equipment Design , Equipment Failure Analysis , Female , France/epidemiology , Humans , Incidence , Male , Middle Aged , Retrospective Studies , Risk Factors , Therapy, Computer-Assisted/statistics & numerical data , Young Adult
4.
Heart Rhythm ; 10(7): 1012-8, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23499630

ABSTRACT

BACKGROUND: Despite isolated reports of Brugada syndrome (BrS) in the inferior or lateral leads, the prevalence and prognostic value of ST elevation in the peripheral electrocardiographic (ECG) leads in patients with BrS remain poorly known. OBJECTIVE: To study the prevalence, characteristics, and prognostic value of type 1 ST elevation and ST depression in the peripheral ECG leads in a large cohort of patients with BrS. METHODS: ECGs from 323 patients with BrS (age 47 ± 13 years; 257 men) with spontaneous (n = 141) or drug-induced (n = 182) type 1 ECG were retrospectively reviewed. Two hundred twenty-five (70%) patients were asymptomatic, 72 (22%) patients presented with unexplained syncope, and 26 (8%) patients presented with sudden death (12 patients) or appropriated implantable cardioverter-defibrillator therapies (14 patients) at diagnosis or over a mean follow-up of 48 ± 34 months. RESULTS: Thirty (9%) patients presented with type 1 ST elevation in at least 1 peripheral lead (22 patients in the aVR leads, 2 in the inferior leads, 5 in both aVR and inferior leads, and 1 in the aVR and VL leads). Patients with type 1 ST elevation in the peripheral leads more often had mutations in the SCN5A gene, were more often inducible, had slower heart rate, and higher J-wave amplitude in the right precordial leads. Twenty-seven percent (8 of 30) of the patients with type 1 ST elevation in the peripheral leads experimented sudden death/appropriate implantable cardioverter-defibrillator therapy, whereas it occurred in only 6% (18 of 293) of other patients (P < .0001). In multivariate analysis, type 1 ECG in the peripheral leads was independently associated with malignant arrhythmic events (odds ratio 4.58; 95% confidence interval 1.7-12.32; P = .0025). CONCLUSIONS: Type 1 ST elevation in the peripheral ECG leads can be seen in 10% of the patients with BrS and is an independent predictor for a malignant arrhythmic event.


Subject(s)
Brugada Syndrome/physiopathology , Death, Sudden, Cardiac/epidemiology , Electrocardiography/instrumentation , Electrodes , Adolescent , Adult , Aged , Aged, 80 and over , Brugada Syndrome/mortality , Female , Follow-Up Studies , France/epidemiology , Humans , Male , Middle Aged , Prevalence , Retrospective Studies , Survival Rate/trends , Young Adult
5.
Minerva Cardioangiol ; 58(4): 449-83, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20938412

ABSTRACT

Primary electrical diseases or channelopathies are inherited genetic alterations of the cell ionic and electrical behavior leading to various cardiac arrhythmias carrying the risk of sudden death. A descriptive review of the successively described channelopathies is made in this article, with emphasis on the clinical manifestations, the genetic background and the currently accepted therapeutic options.


Subject(s)
Channelopathies/diagnosis , Channelopathies/therapy , Channelopathies/epidemiology , Channelopathies/genetics , Death, Sudden, Cardiac , Electrophysiology , Humans , Long QT Syndrome/diagnosis , Long QT Syndrome/genetics , Long QT Syndrome/therapy , Risk Assessment , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/genetics , Tachycardia, Ventricular/therapy , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/physiopathology , Ventricular Fibrillation/therapy
6.
Rev Mal Respir ; 25(1): 73-7, 2008 Jan.
Article in French | MEDLINE | ID: mdl-18288055

ABSTRACT

INTRODUCTION: Pulmonary vein stenosis is a rare condition with a high mortality. With the advent of radiofrequency ablation for atrial fibrillation a new cause of pulmonary vein stenosis has emerged. OBSERVATIONS: We report two cases of severe pulmonary vein stenosis. In the first case the diagnosis was obtained rapidly and balloon angioplasty with stent implantation was performed in the two left pulmonary veins. Recurrent occlusion occurred within the stents, extensive pulmonary infiltrates resembling pulmonary venous infarction developed and the patient died. In the second case the diagnosis was missed initially because the clinical picture suggested thrombo-embolic disease or infection. Balloon angioplasty with stent implantation was performed later. Restenosis occurred after 18 months. These two cases illustrate the frequency with which percutaneously inserted venous prostheses thombose. CONCLUSIONS: Clinicians should be familiar with the possibility of the development of pulmonary vein stenosis after radiofrequency ablation for atrial fibrillation. Pulmonary vein stenosis remains a difficult condition to manage. The pulmonary infarction should probably be considered as an urgent indication for surgical resection or even transplantation.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Pulmonary Veins , Adult , Angioplasty, Balloon , Constriction, Pathologic/etiology , Constriction, Pathologic/therapy , Female , Humans , Recurrence , Stents
SELECTION OF CITATIONS
SEARCH DETAIL
...