Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Teach ; : e13770, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38686890

ABSTRACT

BACKGROUND: Three-dimensional (3-D) printing offers an innovative option to produce clinical simulators because of its low production costs and widespread availability. We aimed to develop a low-cost, 3-D printed knot-tying simulator that overcomes the barriers students face in self-directed skills development. APPROACH: Medical students completing a procedural residency preparation course (PRPC) completed a pre-survey with Likert scales and multiple choice questions to assess their perceptions of and barriers to self-directed knot-tying practice. Subsequently, a 3-D printed knot-tying simulator, which contains a progression of knot-tying challenges and a designated video curriculum, was designed. After utilising the simulator in a 1-hour, faculty-guided knot-tying session, PRPC students assessed the educational utility and usability of the simulator via a post-survey. EVALUATION: The primary barriers students faced in engaging in self-directed knot-tying practice included limited accessibility to simulators and insufficient knowledge of knot-tying techniques. Many students (91.3%, n = 21) agreed that practicing with the simulator improved their knot-tying motor skills and was easy to use (100%, n = 23). Twenty-two (95.7%) students agreed that they would continue to use the simulator beyond the knot-tying session and PRPC. IMPLICATIONS: We demonstrate the educational utility and usability of a novel 3-D printed knot-tying simulator for medical education. Enabling students to engage in self-directed technical skills development is critical in developing surgical skills that can translate to clinical environments. Our simulator highlights the benefits of 3-D printers as an innovative, inexpensive option to improve the availability and accessibility to medical education tools.

2.
ATS Sch ; 5(1): 142-153, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38633515

ABSTRACT

Background: Although hands-on simulation plays a valuable role in procedural training, there are limited tools available to teach pediatric flexible bronchoscopy (PFB). Fellowship programs rely on patient encounters, with inherent risk, or high-cost virtual reality simulators that may not be widely available and create education inequalities. Objective: Our objective was to study the educational value and transferability of a novel, low-cost, three-dimensional-printed pediatric airway model (3D-AM) for PFB training. Our central hypothesis was that the 3D-AM would have high educational value and would be easily transferrable to learners at different teaching hospitals. Methods: The 3D-AM was designed to teach technical bronchoscopy skills, airway anatomy, airway pathology, and bronchoalveolar lavage (BAL). The curriculum was offered to incoming fellows in pediatric pulmonology, pediatric surgery, and pediatric critical care across three different teaching institutions. After course completion, each participant assessed the simulation model(s) with a 5-point Likert scale across six domains: physical attributes, realism of experience, ability to perform tasks, value, relevance, and global impression. The expert instructors assessed the learners' competency using a modified version of the Bronchoscopy Skills and Tasks Assessment Tool. Results: A total of 14 incoming fellows participated in the course. The mean scores for the 3D-AM across all six domains and across the three institutions was between 4 and 5, suggesting that learners generally had a favorable impression and a similar experience across different institutions. All learners "agreed" or "strongly agreed" that the course was a valuable use of their time, helped teach technical skills and airway anatomy, and would be useful for extra training during fellowship. Most of the learners correctly identified anatomy, bronchomalacia, and performed a BAL. Wall trauma was observed in 36% of learners. Conclusion: The utility, low cost, and transferability of this model may create opportunities for PFB training across different institutions despite resource limitations in the United States and abroad.

3.
J Orthop Res ; 42(4): 806-810, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37804218

ABSTRACT

Disuse osteopenia is a well-recognized consequence of prolonged physical inactivity, but its rate after orthopaedic injuries necessitating non-weight-bearing is not well studied. The purpose of this study was to estimate the rate of disuse osteopenia at the lumbar spine and proximal femur in patients with lower extremity trauma admitted to the hospital. We performed a retrospective chart review of patients with lower extremity trauma with a period of strict non-weight-bearing between completion of two computed tomography (CT) scans. The radiodensity of the proximal femur or lumbar vertebrae was measured from the earliest and latest available CT scans within the non-weight-bearing timeframe. The change in estimated bone mineral density (eBMD) was calculated as a proxy for disuse osteopenia. A total of 189,111 patients were screened, with 17 patients in the proximal femur group and 15 patients in the lumbar spine group meeting inclusion and exclusion criteria. The average rate of change in eBMD of the proximal femur was a decrease of 7.54 HU/day, 95% confidence interval (CI) [3.65, 11.43]. The average rate of change in eBMD of the lumbar spine was an increase of 1.45 HU/day, 95% CI [-3.15, 6.06]. In admitted, non-weight-bearing orthopaedic trauma patients, our novel study suggests that the proximal femur experiences disuse osteopenia during periods of non-weight-bearing, although this finding was not observed at the lumbar spine. The clinical significance of this data underscores the important consideration of disuse osteopenia by all physicians when caring for patients that may require non-weight-bearing restrictions.


Subject(s)
Bone Diseases, Metabolic , Humans , Retrospective Studies , Bone Diseases, Metabolic/diagnostic imaging , Bone Density , Femur/diagnostic imaging , Tomography, X-Ray Computed/methods , Lumbar Vertebrae/diagnostic imaging , Absorptiometry, Photon
4.
Surg Open Sci ; 16: 221-225, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38035223

ABSTRACT

Introduction: Clinical simulators are an important resource for medical students seeking to improve their fundamental surgical skills. Three-dimensional (3-D) printing offers an innovative method to create simulators due to its low production costs and reliable printing fidelity. We aimed to validate a 3-D printed knot-tying simulator named Nodo-Tie. Methods: We designed a 3-D printed knot-tying simulator integrated with a series of knot-tying challenges and a designated video curriculum made accessible via a quick-response (QR) code. The Nodo-Tie, which costs less than $1 to print and assemble, was distributed to second-year medical students starting their surgical clerkship. Participants were asked to complete a survey gauging the simulator's usability and educational utility. The time between simulator distribution and survey completion was eight weeks. Results: Students perceived the Nodo-Tie as easy-to-use (4.6 ± 0.8) and agreed it increased both their motor skills (4.5 ± 0.9) and confidence (4.5 ± 0.8) for tying surgical knots in the clinical setting. Many students agreed the Nodo-Tie provided a stable, durable surface for knot-tying practice (83.7%, n = 41) and that they would continue to use it beyond their participation in the study period (91.7%, n = 44). Discussion: Medical students found this interactive, 3-D printed knot-tying simulator to be an effective tool to use for self-directed development of their knot-tying skills. Given the Nodo-Tie's low cost, students were able to keep the Nodo-Tie for use beyond the study period. This increases the opportunity for students to engage in the longitudinal practice necessary to master knot-tying as they progress through their medical education. Key messages: Clinical simulators provide proactive learners with reliable, stress-free environments to engage in self-directed surgical skills development. The Nodo-Tie, a 3-D printed simulator, serves as a cost-effective, interactive tool for medical students to develop their knot-tying abilities beyond the clinical setting.

5.
Ann Otol Rhinol Laryngol ; 132(6): 607-613, 2023 Jun.
Article in English | MEDLINE | ID: mdl-35723201

ABSTRACT

IMPORTANCE: Prominotia has functional and esthetic impact for the child and family and proficiency in otoplasty requires experiential rehearsal. OBJECTIVES: To design and validate an anatomically accurate, 3D printed prominotia simulator for rehearsal of otoplasties. METHODS: A 3D prominotia model was designed from a computed tomographic (CT) scan and edited in 3-matic software. Negative molds were 3D printed and filled with silicone. Expert surgeons performed an otoplasty procedure on these simulators and provided Likert-based feedback. RESULTS: Six expert surgeons with a mean of 14.3 years of practice evaluated physical qualities, realism, performance, and value of the simulator. The simulator was rated on a scale of 1 (no value) to 5 (great value) and scored 3.83 as a training tool, 3.83 as a competency evaluation tool, and 4 as a rehearsal tool. CONCLUSIONS: Expert validation rated the otoplasty simulator highly in physical qualities, realism, performance, and value. With minor modifications, this model demonstrates valuable educational potential.


Subject(s)
Plastic Surgery Procedures , Simulation Training , Child , Humans , Printing, Three-Dimensional , Software , Tomography, X-Ray Computed
6.
Int J Pediatr Otorhinolaryngol ; 162: 111273, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36030629

ABSTRACT

OBJECTIVE: Our objective was to create and evaluate a novel virtual platform dissection course to complement pediatric otolaryngology fellowship training in the setting of the COVID-19 pandemic. METHODS: A four-station, four-simulator virtual course was delivered to pediatric otolaryngology fellows virtually using teleconferencing software. The four stations consisted of microtia ear carving, airway graft carving, cleft lip repair, and cleft palate repair. Fellows were asked to complete pre- and post-course surveys to evaluate their procedural confidence, expertise, and attitudes towards the course structure. RESULTS: Statistical analysis of pre-course survey data showed fellows agreed that simulators should play an important part in surgical training (4.59 (0.62)); would like more options for training with simulators (4.31 (0.88)); and would like the option of saving their simulators for later reference (4.41 (0.85)). Fellows found the surgical simulators used in the course to be valuable as potential training tools (3.96 (0.96)), as competency or evaluation tools (3.91 (0.98)), and as rehearsal tools (4.06 (0.93)). Analysis showed a statistically significant improvement in overall surgical confidence in performing all four procedures. CONCLUSION: This virtual surgical dissection course demonstrates 3D printed surgical simulators can be utilized to teach fellows advanced surgical techniques in a low-risk, virtual environment. Virtual platforms are a viable, highly-rated option for surgical training in the setting of restricted in-person meetings and as a mechanism to increase access for fellows by reducing costs and travel requirements during unrestricted periods.


Subject(s)
COVID-19 , Otolaryngology , Child , Clinical Competence , Fellowships and Scholarships , Humans , Otolaryngology/education , Pandemics , Printing, Three-Dimensional
SELECTION OF CITATIONS
SEARCH DETAIL
...