Results 1 - 20 de 25
Filter
2.
Sci Rep ; 14(1): 293, 2024 01 02.
Article in English | MEDLINE | ID: mdl-38168766

ABSTRACT

A study was conducted with 115 subjects who regularly drove at night to validate a refraction protocol for detecting refractive visual changes from daytime to nighttime conditions. Objective and subjective refractions were performed in both photopic and mesopic conditions, with a dark adaptation period before the mesopic subjective refraction. The results showed that in mesopic conditions, visual acuity decreased by 0.2 logMAR units on average (p < 0.01), and there was a myopic refractive shift of - 0.36 ± 0.20 D (p < 0.01). Most subjects (92.2%) exhibited a myopic refractive shift of at least 0.12 D. Compensation of refractive shift improved mesopic visual acuity by 0.06 logMAR on average (p < 0.01) and higher refractive shifts showed higher improvement. Night Rx was preferred by 82.1% of subjects with myopic refractive shift. Gender and age did not significantly affect the refractive shift, although myopes showed a higher shift compared to emmetropes (p < 0.01). The refractive shift remained stable over time when the time slot of the day did not change (p < 0.01). Night Rx protocol proved to be a robust and accurate method for identifying drivers with refractive changes when transitioning from photopic to mesopic conditions. The high prevalence and inter-individual variability of Rx shift highlight the need of customized refraction.


Subject(s)
Myopia , Humans , Myopia/diagnosis , Visual Acuity , Refraction, Ocular , Vision Tests , Emmetropia
3.
J Refract Surg ; 37(2): 91-97, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33577694

ABSTRACT

PURPOSE: To evaluate the visual, refractive, topographic, and aberrometric outcomes after intracorneal ring segments (ICRS) implantation in adolescent patients with keratoconus. METHODS: A retrospective longitudinal study was undertaken with a total of 61 eyes from 47 patients with keratoconus, aged between 13 and 18 years, implanted with a Ferrara-type ICRS. Topography (flattest keratometry, steepest keratometry, and asphericity), uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive error (sphere and cylinder), and aberrometric measurements (spherical aberration and vertical coma) were evaluated before surgery and at 1 month, 6 months, 1 year, and 2 years after surgery. RESULTS: UDVA exhibited a statistically significant increase at all times from 1 month to 2 years postoperatively (P < .001), whereas CDVA showed a statistically significant improvement at 1 month, 6 months, and 2 years (P < .002), but dropped in significance at 1 year postoperatively (P = .097). The refractive error analysis showed no variation in statistical significance in the sphere (P = .712) after 2 years. The cylinder presented a statistically significant decrease in diopters at all times from preoperatively to 2 years postoperatively (P < .007). Steepest keratometry manifested a statistically significant decrease in steepness at all times after surgery (P < .001), whereas flattest keratometry lost significance at 1 year (P = .298) and 2 years (P = .053) postoperatively. There was no statistically significant change in the spherical aberration at any of the measured times. The vertical coma was only significantly different at 2 years postoperatively (P = .001). CONCLUSIONS: ICRS implantation is a safe and effective treatment for improving visual and corneal morphological parameters as shown at 2 years of follow-up in adolescent patients with keratoconus. It is a good option to flatten and regularize the cornea and to temporarily improve the quality of life of young patients and delay the need for keratoplasty. [J Refract Surg. 2021;37(2):91-97.].


Subject(s)
Keratoconus , Adolescent , Corneal Stroma/surgery , Corneal Topography , Follow-Up Studies , Humans , Keratoconus/surgery , Longitudinal Studies , Prostheses and Implants , Prosthesis Implantation , Quality of Life , Refraction, Ocular , Retrospective Studies
4.
Cont Lens Anterior Eye ; 43(2): 130-136, 2020 04.
Article in English | MEDLINE | ID: mdl-31812508

ABSTRACT

PURPOSE: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape. METHODS: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 ± 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power +2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity were analysed, among others. RESULTS: The LDI was generally higher with multifocal lenses, varying from 3.7 ± 0.3 % of the single vision lens to 6.1 ± 3.3 % of the multifocal centre-distance design and the 5-mm pupil. Larger pupils gave higher LDI values, changing from 4.5 ± 2.0 % (3 mm) to 6.1 ± 3.3 % (5 mm) with the centre-distance design. The elliptical pupil produced the largest discrepancy in the distortion size between the vertical and horizontal directions. The centre-distance and centre-near designs behaved similarly in terms of light distortion. CONCLUSIONS: The multifocal contact lenses of the study increased light distortion effects under low light conditions, especially with larger pupils. The shape of the distortion pattern is associated with the shape of the pupil. It seems that not all, but a big percentage of light distortion would be produced by the presence of the out-of-focus images given by a multifocal lens.


Subject(s)
Contact Lenses, Hydrophilic , Pupil/physiology , Refraction, Ocular/physiology , Refractive Errors/therapy , Visual Acuity , Adult , Equipment Design , Female , Healthy Volunteers , Humans , Male , Middle Aged , Refractive Errors/physiopathology
5.
Arq. bras. oftalmol ; 82(3): 207-213, May-June 2019. tab, graf
Article in English | LILACS | ID: biblio-1001311

ABSTRACT

ABSTRACT Purpose: To measure changes in the anterior ciliary muscle during accommodation at the nasal, superior, temporal, and inferior sectors by means of an anterior chamber optical coherence tomographer, and correlate them with vergence changes. Methods: Twenty-four subjects with healthy, phakic eyes, whose mean age was 27.1 ± 8.9 years, underwent measurement with an anterior chamber optical coherence tomographer. The anterior ciliary muscle was measured at the nasal, temporal, superior, and inferior sectors for 0, -1, -2, and -3 D of vergence. A linear model was used to assess the correlation of each eye parameter with the accommodative demand. Results: The anterior ciliary muscle area significantly increased with accommodation for each sector, with a maximum increase of about 30% for the nasal-temporal sectors and about 25% for the inferior-temporal sectors. The linear model showed a tendency toward a positive relationship between change in the ciliary muscle area of each sector and vergence. Conclusion: The anterior ciliary muscle area tends to increase with accommodation, although the increase has been shown to be symmetric between the pair sectors superior-nasal and inferior-temporal. These results may help to increase understanding of accommodation biometry and biomechanics.


RESUMO Objetivo: Medir as alterações do músculo ciliar anterior durante a acomodação nos setores nasal, superior, temporal e inferior, através de um tomógrafo de coerência óptica de câmara anterior, e correlacioná-las com alterações de vergência. Métodos: Vinte e quatro indivíduos com olhos saudáveis e fácicos, com idade média de 27,1 ± 8,9 anos, foram submetidos à medida com um tomógrafo de coerência óptica de câmara anterior. O músculo ciliar anterior foi medido nos setores nasal, temporal, superior e inferior para 0, -1, -2 e -3D de vergência. Um modelo linear foi utilizado para avaliar a correlação de cada parâmetro do olho com a demanda acomodativa. Resultados: A área do músculo ciliar anterior aumentou significativamente com a acomodação em cada setor, com um aumento máximo foi de cerca de 30% para os setores naso-temporais, e cerca de 25% para os inferiores-temporais. O modelo linear mostrou uma tendência para uma relação positiva entre a alteração da área do músculo ciliar de cada setor e a vergência. Conclusão: A área do músculo ciliar anterior tende a aumentar com a acomodação, embora o aumento tenha se mostrado simétrico entre os setores superior-nasal e inferior-temporal. Estes resultados podem ajudar a aumentar a compreensão da biometria e biomecânica da acomodação.


Subject(s)
Humans , Male , Female , Adult , Young Adult , Ciliary Body/physiology , Ciliary Body/diagnostic imaging , Tomography, Optical Coherence/methods , Accommodation, Ocular/physiology , Reference Values , Biomechanical Phenomena , Linear Models , Analysis of Variance , Biometry/methods , Statistics, Nonparametric
6.
J. optom. (Internet) ; 12(1): 14-21, ene.-mar. 2019. ilus, graf, tab
Article in English | IBECS | ID: ibc-178508

ABSTRACT

Purpose: To compare changes in the ciliary muscle area at different sectors between pre-presbyopic and presbyopic eyes during accommodation by means of an anterior segment optical coherence tomographer (OCT). Methods: The anterior ciliary muscle area was measured in 20 healthy and phakic pre-presbyopic eyes, whose mean age was 23.3 ± 4.4 years, and in 20 healthy and phakic presbyopic eyes, whose mean age was 46.5 ± 5.2 years. The relative change in the cross-sectional area of the ciliary muscle was measured at the nasal, inferior, and temporal sectors between 0 and - 3 D of vergence, in -1 D step. A linear model was used to assess the correlation of each eye parameter with the accommodative demand. Results: Each population group showed a significant increase in the anterior ciliary muscle area for each sector. The maximum increase in the ciliary muscle area within the pre-presbyopic group was about 30%, and for the presbyopic one was about 25%. At the same time, it was obtained that the larger the vergence, the larger the variability. Furthermore, the linear model showed a positive tendency between the change in the ciliary muscle area of each sector and the vergence for both population groups, which coefficient of determination was in all cases greater than 0.93. Conclusion: The anterior ciliary muscle area tends to increase with accommodation. The presbyopic nasal, inferior, and temporal ciliary muscle seem to have the same contractile capability as the young presbyopic ciliary muscle. These results might help to increase the evidences in the knowledge regarding the modern understanding of accommodation biometry and biomechanics


Objetivo: Comparar los cambios en el área del músculo ciliar en diferentes sectores entre ojos con pre-presbicia y presbicia durante la acomodación, por medio de un tomógrafo de coherencia óptica (OCT) de segmento anterior. Métodos: Se midió el área del músculo ciliar en 24 ojos sanos fáquicos y con pre-presbicia, con edad media de 23,3 ± 4,4 años, y en 20 ojos sanos fáquicos y con presbicia, con edad media de 46,5 ± 5,2 años. El cambio relativo en el área transeccional del músculo ciliar se midió en los sectores nasal, inferior y temporal entre 0 y -3 D de vergencia, en pasos de -1D. Se utilizó un modelo lineal para valorar la correlación de cada parámetro del ojo con la demanda acomodativa. Resultados: Cada grupo de población reflejó un incremento significativo en el área del músculo ciliar para cada sector. El incremento máximo en el área del músculo ciliar en el grupo de pre-presbicia fue de alrededor del 30%, y para el grupo de presbicia de cerca del 25%. También se observó que cuanto mayor era la vergencia, mayor era la variabilidad. Además, el modelo lineal reflejó una tendencia positiva entre el cambio en el área del músculo ciliar de cada sector y la vergencia para ambos grupos de población, cuyo coeficiente de determinación fue en todos los casos superior a 0,93. Conclusión: El área anterior del músculo ciliar tiende a incrementarse con la acomodación. El músculo ciliar en los sectores nasal, inferior y temporal en la presbicia parece tener la misma capacidad contráctil que el músculo ciliar pre-presbicia. Estos resultados podrían ayudar a incrementar las evidencias en el conocimiento relativo a la comprensión moderna de la biometría de acomodación y la biomecánica


Subject(s)
Humans , Male , Female , Adolescent , Young Adult , Adult , Middle Aged , Accommodation, Ocular/physiology , Aging/physiology , Ciliary Body/anatomy & histology , Presbyopia/physiopathology , Analysis of Variance , Ciliary Body/physiology , Refraction, Ocular/physiology , Tomography, Optical Coherence
7.
Arq Bras Oftalmol ; 82(3): 207-213, 2019.
Article in English | MEDLINE | ID: mdl-30810617

ABSTRACT

PURPOSE: To measure changes in the anterior ciliary muscle during accommodation at the nasal, superior, temporal, and inferior sectors by means of an anterior chamber optical coherence tomographer, and correlate them with vergence changes. METHODS: Twenty-four subjects with healthy, phakic eyes, whose mean age was 27.1 ± 8.9 years, underwent measurement with an anterior chamber optical coherence tomographer. The anterior ciliary muscle was measured at the nasal, temporal, superior, and inferior sectors for 0, -1, -2, and -3 D of vergence. A linear model was used to assess the correlation of each eye parameter with the accommodative demand. RESULTS: The anterior ciliary muscle area significantly increased with accommodation for each sector, with a maximum increase of about 30% for the nasal-temporal sectors and about 25% for the inferior-temporal sectors. The linear model showed a tendency toward a positive relationship between change in the ciliary muscle area of each sector and vergence. CONCLUSION: The anterior ciliary muscle area tends to increase with accommodation, although the increase has been shown to be symmetric between the pair sectors superior-nasal and inferior-temporal. These results may help to increase understanding of accommodation biometry and biomechanics.


Subject(s)
Accommodation, Ocular/physiology , Ciliary Body/diagnostic imaging , Ciliary Body/physiology , Tomography, Optical Coherence/methods , Adult , Analysis of Variance , Biomechanical Phenomena , Biometry/methods , Female , Humans , Linear Models , Male , Reference Values , Statistics, Nonparametric , Young Adult
8.
Int Ophthalmol ; 39(2): 303-310, 2019 Feb.
Article in English | MEDLINE | ID: mdl-29260498

ABSTRACT

PURPOSE: To evaluate ocular biometric changes with different accommodative stimuli using a new swept-source optical biometer. METHODS: Only the right eye was analyzed. Each subject was measured six times with the IOLMaster 700 swept-source optical biometer (Carl Zeiss Meditec, Jena, Germany) with the subject looking at the stimulus shown by the instrument and with the subject looking at a target placed outside the instrument at 0D of vergence. Axial length (AL), anterior chamber depth (ACD), central corneal thickness (CCT), lens thickness (LT), white-to-white (WTW), and keratometry readings (K1 and K2) were evaluated in both cases. To assess if the changes found may affect the intraocular (IOL) power calculation for surgical applications, we have applied some formulae, using the software provided by the optical biometer manufacturer, to the ocular parameters found in both situations for three different types of IOLs. RESULTS: No statistically significant differences were found for AL, CCT, WTW, K1 and K2 between the subject looking at the stimulus of the biometer and looking at the outside target at 0D of vergence (p > 0.05). However, the measurement of ACD revealed a statistically significant reduction of 20 microns (p = 0.03) and, on the contrary, LT increased significantly 30 microns (p = 0.02). ACD and LT changes were highly correlated (R2 = 0.91). As for the IOL power calculation, in all cases, the mean change was lower than 0.25 D both for IOL power selection and residual refraction. CONCLUSIONS: Although ACD and LT change significantly with different accommodative stimuli measured by swept-source optical biometry, these changes are not clinically relevant.


Subject(s)
Accommodation, Ocular/physiology , Axial Length, Eye/physiopathology , Biometry/methods , Cataract/physiopathology , Lens, Crystalline/physiopathology , Tomography, Optical Coherence/methods , Adult , Anterior Chamber/diagnostic imaging , Anterior Chamber/physiopathology , Cataract/diagnosis , Female , Humans , Lens, Crystalline/diagnostic imaging , Male , Photic Stimulation , Reproducibility of Results
9.
J Optom ; 12(1): 14-21, 2019.
Article in English | MEDLINE | ID: mdl-29627301

ABSTRACT

PURPOSE: To compare changes in the ciliary muscle area at different sectors between pre-presbyopic and presbyopic eyes during accommodation by means of an anterior segment optical coherence tomographer (OCT). METHODS: The anterior ciliary muscle area was measured in 20 healthy and phakic pre-presbyopic eyes, whose mean age was 23.3±4.4 years, and in 20 healthy and phakic presbyopic eyes, whose mean age was 46.5±5.2 years. The relative change in the cross-sectional area of the ciliary muscle was measured at the nasal, inferior, and temporal sectors between 0 and -3 D of vergence, in -1 D step. A linear model was used to assess the correlation of each eye parameter with the accommodative demand. RESULTS: Each population group showed a significant increase in the anterior ciliary muscle area for each sector. The maximum increase in the ciliary muscle area within the pre-presbyopic group was about 30%, and for the presbyopic one was about 25%. At the same time, it was obtained that the larger the vergence, the larger the variability. Furthermore, the linear model showed a positive tendency between the change in the ciliary muscle area of each sector and the vergence for both population groups, which coefficient of determination was in all cases greater than 0.93. CONCLUSION: The anterior ciliary muscle area tends to increase with accommodation. The presbyopic nasal, inferior, and temporal ciliary muscle seem to have the same contractile capability as the young presbyopic ciliary muscle. These results might help to increase the evidences in the knowledge regarding the modern understanding of accommodation biometry and biomechanics.


Subject(s)
Accommodation, Ocular/physiology , Aging/physiology , Ciliary Body/anatomy & histology , Presbyopia/physiopathology , Adolescent , Adult , Analysis of Variance , Ciliary Body/physiology , Female , Humans , Male , Middle Aged , Refraction, Ocular/physiology , Tomography, Optical Coherence , Young Adult
10.
Clin Exp Optom ; 101(2): 188-192, 2018 03.
Article in English | MEDLINE | ID: mdl-29023989

ABSTRACT

BACKGROUND: To evaluate the impact on the ocular surface of a daily disposable hydrogel contact lens with high water content compared with two silicone hydrogel daily disposable lenses of lower water content. METHODS: The hydrogel lens assessed was made from nesofilcon A and the silicone hydrogel lenses were made of delefilcon A and stenfilcon A. Contact lens thickness was measured to assess material stability during daily wear, and ocular surface parameters such as tear film osmolarity, tear meniscus area and central corneal thickness were also assessed. Optical quality was analysed for all cases by means of wavefront aberrometry. RESULTS: The nesofilcon A was shown to be the thinnest lens (p < 0.001), while no differences in lens thickness were found between the two silicone hydrogel lenses (p = 0.495). No significant differences were found in tear film osmolarity, tear meniscus area, central corneal thickness or corneal aberrations, either as a function of the lens measured or time of use (p > 0.05). CONCLUSION: In spite of having the thinnest lens and the highest water content, the hydrogel does not significantly impact on tear film and corneal swelling after one day of use in first-time wearers.


Subject(s)
Conjunctiva/physiology , Contact Lenses, Hydrophilic , Cornea/physiology , Hydrogel, Polyethylene Glycol Dimethacrylate , Myopia/therapy , Prosthesis Design , Tears/chemistry , Adult , Disposable Equipment , Equipment Design , Female , Humans , Hydrogel, Polyethylene Glycol Dimethacrylate/chemistry , Male , Osmolar Concentration , Surface Properties , Young Adult
11.
Int Ophthalmol ; 38(6): 2451-2462, 2018 Dec.
Article in English | MEDLINE | ID: mdl-29075940

ABSTRACT

PURPOSE: The aim of this pilot study was to evaluate a new semiautomatic procedure to assess in vivo changes in the crystalline lens and ciliary muscle during accommodation. METHODS: A total of 14 subjects were divided into two groups, young (aged between 20 and 25 years) and adult (aged between 35 and 40 years), and measured with an anterior segment optical coherence tomography. A semiautomatic procedure was implemented to measure the central lens thickness (CLT), anterior lens radius (ALR) and the ciliary muscle area (CMA) for the unaccommodated eye and for a vergence of - 3.00 D. RESULTS: The CLT increase for each population group was smaller than 5%, and the dispersion of each group was similar between them. Contrariwise, the reduction in the ALR was about 30% for both groups, although the young one showed the largest variability. The CMA increase was smaller than 30% for both groups, and the dispersion was similar between them. For each metric, differences between both groups were not statistically significant. CONCLUSIONS: The semiautomatic procedure seems to be useful for the in vivo analysis of the accommodative system. Additionally, the results obtained showed that changes in the CLT were much smaller compared to those obtained for the ALR or CMA.


Subject(s)
Accommodation, Ocular/physiology , Ciliary Body/anatomy & histology , Diagnosis, Computer-Assisted/methods , Lens, Crystalline/anatomy & histology , Oculomotor Muscles/anatomy & histology , Tomography, Optical Coherence/methods , Adult , Female , Humans , Male , Pilot Projects , Refraction, Ocular/physiology , Young Adult
12.
Clin Exp Optom ; 101(1): 57-63, 2018 Jan.
Article in English | MEDLINE | ID: mdl-28718954

ABSTRACT

BACKGROUND: The power profile of multifocal contact lenses has been demonstrated to report important information that could be used during the fitting process. The aim of this work is to describe the power profile of a recent set of gas permeable multifocal contact lenses as a function of the pupil radius. METHODS: The measured multifocal contact lenses have a centre-distance design, and are available with five distance-vision diameters (XS, S, M, L and XL) and two different additions: Type A (up to +2.00 D) and Type B (up to +2.50 D). The optical device NIMO TR1504 (Lambda-X, Nivelles, Belgium) was used to obtain the power profile measurements. The optical lens power distribution as a function of the aperture radius was described in terms of radial computed colour maps, radial averaged power profiles, addition, and lens portion used for near vision. RESULTS: The amount of total addition achieved depends on the diameter of the distance-vision area. That is, the bigger the distance vision area, the bigger the radius of the lens in order to get the same level of addition. In other words, the XS lens provides higher addition values compared to the XL lens design for a given aperture. CONCLUSIONS: The XS and S designs seem to be aimed to favour near vision, whereas the L and XL designs seem to favour distance vision. For this reason, patients who demand good distance vision might benefit from the L or XL designs, and those with high demand on near-vision tasks might benefit from the XS or S designs. The M design could be the best option for those patients who have the same needs for distance and near vision.


Subject(s)
Contact Lenses , Presbyopia/therapy , Refraction, Ocular/physiology , Equipment Design , Humans , Optical Phenomena , Presbyopia/physiopathology , Visual Acuity
13.
Arq Bras Oftalmol ; 80(6): 364-368, 2017.
Article in English | MEDLINE | ID: mdl-29267571

ABSTRACT

PURPOSE: To assess changes in anatomic structures in the anterior eye segment in terms of axial lengths with accommodation via optical coherence tomography. METHODS: In this observational study, 25 eyes of 25 healthy adults were examined using the Visante® omni optical coherence tomography system. Central corneal thickness, anterior chamber depth, central lens thickness, and anterior segment length were assessed. The evaluated parameters were obtained with accommodation using different stimulus vergences, namely 0.0, -1.0, -2.0, and -3.0 D. Variation of these parameters was compared among different levels of accommodation. RESULTS: Central corneal thickness was not altered at any stimulus vergence during accommodation (p>0.05). Conversely, anterior chamber depth was significantly reduced (p<0.05), whereas central lens thickness was significantly increased (p<0.05). Anterior segment length also increased with accommodation (p<0.05), indicating backward movement of the posterior pole. CONCLUSIONS: There are significant variations in anterior segment lengths that occur with accommodation. Studying these changes will provide useful information regarding the accommodation mechanism that can improve our understanding of this process and facilitate clinical decision-making by practitioners.


Subject(s)
Accommodation, Ocular/physiology , Anterior Eye Segment/anatomy & histology , Anterior Eye Segment/diagnostic imaging , Tomography, Optical Coherence , Adult , Female , Humans , Male , Middle Aged , Young Adult
14.
Arq. bras. oftalmol ; 80(6): 364-368, Nov.-Dec. 2017. tab, graf
Article in English | LILACS | ID: biblio-888165

ABSTRACT

ABSTRACT Purpose: To assess changes in anatomic structures in the anterior eye segment in terms of axial lengths with accommodation via optical coherence tomography. Methods: In this observational study, 25 eyes of 25 healthy adults were examined using the Visante® omni optical coherence tomography system. Central corneal thickness, anterior chamber depth, central lens thickness, and anterior segment length were assessed. The evaluated parameters were obtained with accommodation using different stimulus vergences, namely 0.0, -1.0, -2.0, and -3.0 D. Variation of these parameters was compared among different levels of accommodation. Results: Central corneal thickness was not altered at any stimulus vergence during accommodation (p>0.05). Conversely, anterior chamber depth was significantly reduced (p<0.05), whereas central lens thickness was significantly increased (p<0.05). Anterior segment length also increased with accommodation (p<0.05), indicating backward movement of the posterior pole. Conclusions: There are significant variations in anterior segment lengths that occur with accommodation. Studying these changes will provide useful information regarding the accommodation mechanism that can improve our understanding of this process and facilitate clinical decision-making by practitioners.


RESUMO Objetivo: Avaliar as mudanças das estruturas anatômicas no segmento anterior do olho em termos de comprimentos axiais com acomodação por meio da tomografia de coerência óptica. Métodos: Neste estudo observacional, foram incluídos 25 olhos de vinte e cinco adultos saudáveis e medidos com o sistema Visante® omni tomografia de coerência óptica. A espessura corneana central, a profundidade da câmara anterior, a espessura central da lente e o comprimento do segmento anterior foram avaliados. Os parâmetros avaliados foram obtidos com acomodação usando diferentes vergências de estímulo: 0,0, -1,0, -2,0 e -3,0 D. A variação desses parâmetros foi comparada para os diferentes níveis de acomodação. Resultados: A espessura corneana central não foi alterada em nenhum estímulo durante a acomodação (p>0,05). A ACD mostrou uma redução significativa (p<0,05), enquanto a espessura central da lente foi significativamente aumentada (p<0,05). O comprimento do segmento anterior também aumentou com acomodação (p<0,05) indicando um movimento do polo posterior para trás. Conclusões: Há variações significativas nos comprimentos do segmento anterior que ocorrem com acomodação. Estudar essas mudanças fornece informações úteis sobre o mecanismo de acomodação para os profissionais, a fim de obter uma melhor compreensão desse processo e ajudá-los a tomar suas decisões clínicas.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Young Adult , Tomography, Optical Coherence , Accommodation, Ocular/physiology , Anterior Eye Segment/anatomy & histology , Anterior Eye Segment/diagnostic imaging
15.
Int J Ophthalmol ; 10(10): 1614-1616, 2017.
Article in English | MEDLINE | ID: mdl-29062784

ABSTRACT

The changes in the iridocorneal angle structure during accommodation are assessed by means of anterior segment optical coherence tomography. Thirteen right eyes were included in the study. The device used for the measurement was the Visante®omni system. The stimuli were set up at different vergences (0.0 D, -1.5 D, and -3.0 D). The angle opening distance 500 and 750, the trabecular iris space area 500 and 750, and the scleral spur angle parameters were assessed at the nasal and temporal regions. The results in the iridotrabecular angle comparing the three accommodative states of the eye did not yield any statistically significant difference at nasal or temporal angle sections. In light of our results and in the conditions of our study, the structures of the iridocorneal angle are not significantly changed with accommodation.

16.
Cont Lens Anterior Eye ; 40(5): 346-350, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28522252

ABSTRACT

PURPOSE: To present a methodology for evaluating the optical quality of rotationally symmetrical contact lenses (CLs) from a single power profile. METHODS: Simulated rotationally symmetrical power profiles corresponding to different CLs designs (monofocal, two-zone center-near bifocal, and four-zone center-distance bifocal) were used to calculate the wavefront error profile by means of numerical integration. Then, each lens wavefront error profile was spun around the center to obtain the lens wavefront error surface. From the surface, monochromatic optical transfer functions (OTF), simulated images and the visual Strehl ratio based on the OTF (VSOTF) were obtained for different distances and pupil sizes (3 and 5.5mm) after performing a through-focus. RESULTS: VSOTF variations, taking into account both vergence and pupil size, were presented for the three CLs designs. The monofocal design showed excellent optical quality only for far vision, whereas the bifocal designs exhibited good optical quality for far and near vision. Modulation transfer function (MTF) from each lens design, pupil size, and work distance agreed with the previous results. CONCLUSIONS: The methodology presented here allows for a rapid and thorough assessment of the optical quality of rotationally symmetrical CLs by means of optical quality metrics, with a special interest in simultaneous image contact lenses. This methodology may be useful for choosing the most suitable lens for each subject's visual demands.


Subject(s)
Contact Lenses , Optics and Photonics , Equipment Design , Humans , Models, Theoretical , Presbyopia/physiopathology , Presbyopia/therapy , Pupil/physiology , Refraction, Ocular/physiology
17.
Graefes Arch Clin Exp Ophthalmol ; 255(7): 1385-1394, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28424868

ABSTRACT

PURPOSE: The purpose of the study was to assess non-invasively the changes in the anterior chamber eye, crystalline lens morphology, and ciliary muscle during accommodation by means of an anterior chamber optical coherence tomographer (OCT), and correlate them with vergence. METHODS: Twenty-five eyes of twenty-five healthy subjects, whose mean age was 29.9±7.1 years, were included and measured with an anterior chamber OCT. The central corneal thickness (CCT), anterior chamber depth (ACD), anterior crystalline lens radius of curvature (ALRC), crystalline lens thickness (CLT), and ciliary muscle area (CMA) were measured for each participant at 0, -1, -2, and -3 D of target vergence. A linear model was used to assess the correlation of each eye parameter with the vergence demand. RESULTS: The mean CCT showed no change for all the accommodative stimuli. The mean ACD and ALRC decreased with the vergence, about 4.5 and 30 % at -3 D, respectively. On the contrary, the CLT and CMA showed an opposite tendency, where the mean CLT was increased by 4.0 % and the mean CMA was done by 26% at -3 D. Statistical significant differences (p < 0.001) were obtained among all vergences for each eye metric, except for the CCT (p = 0.76). CONCLUSION: The ACD and ALRC decreased about 2 and 10 % per dioptre of accommodation, respectively; whereas the CLT and CMA increased about 2 and 9 %, respectively. These results add knowledge regarding the understanding of accommodation and give new perspectives for biomechanics and biometry.


Subject(s)
Accommodation, Ocular/physiology , Anterior Chamber/anatomy & histology , Ciliary Body/anatomy & histology , Lens, Crystalline/anatomy & histology , Muscle, Smooth/anatomy & histology , Refraction, Ocular , Tomography, Optical Coherence/methods , Adult , Ciliary Body/physiology , Female , Healthy Volunteers , Humans , Lens, Crystalline/physiology , Male , Young Adult
18.
Optom Vis Sci ; 93(12): 1552-1559, 2016 12.
Article in English | MEDLINE | ID: mdl-27776082

ABSTRACT

PURPOSE: To analyze the effect of decentration on the optical quality of two diffractive-refractive intraocular lenses, a bifocal and a trifocal, when displaced laterally (horizontal direction) from the center. METHODS: The AT LISA 809M IOL (+3.75 D add) with two main foci and the AT LISA tri 839MP intraocular lens with three main foci (Carl Zeiss Meditec AG, Jena, Germany) were analyzed. The optical quality of the intraocular lenses was measured with the PMTF (power and modulation transfer function [MTF] measurement for refractive and diffractive intraocular lenses) optical bench (Lambda-X, Nivelles, Belgium). The optical quality of the lenses was evaluated by the MTF at different object vergences, the average modulation in the range of frequencies from 0 to 100 cycles/mm, and the through-focus MTF curves. All measures were recorded when the intraocular lenses were centered and decentered for 3.0- and 4.5-mm apertures. The Strehl ratio and the percentage of energy allocated at each focus at the centered position were also obtained. RESULTS: Our results showed a lower optical quality with increasing decentration. The MTFs for the diffractive-refractive intraocular lenses decreased when the intraocular lenses were decentered. Also, the relative percentages of light energy allocated at each object vergence, for both intraocular lenses, agreed well with theoretical specifications and were consistent with the overall design of each lens. CONCLUSIONS: The optical quality of these diffractive-refractive multifocal intraocular lenses was slightly reduced when the induced decentration was less than 0.4 mm. For a decentration of 0.4 mm, the maximum difference in average modulation values was about 18% compared to the centered position.


Subject(s)
Lenses, Intraocular , Optics and Photonics/methods , Refraction, Ocular/physiology , Vision, Ocular , Humans , Prosthesis Design , Vision Tests
19.
J Cataract Refract Surg ; 42(1): 138-47, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26948789

ABSTRACT

PURPOSE: To evaluate the optical quality of 3 multifocal intraocular lenses (IOLs): the Mini Well Ready progressive multifocal aspheric IOL, the AT LISA trifocal diffractive IOL, and the Finevision full diffractive trifocal IOL. SETTING: University of Valencia, Valencia, Spain. DESIGN: Experimental study. METHODS: An instrument designed for measuring real-time modulation transfer function (MTF) and IOL power was used to measure the optical quality of each IOL for 3.0 mm and 4.5 mm apertures. This instrument measures both sagittal and tangential MTFs. The optical quality of each IOL was evaluated with the MTF, through-focus MTF, defocus tolerance, Strehl ratio MTF, and relative percentage of light in each focus. These metrics were evaluated at best focus for each IOL. RESULTS: Through-focus graphs corresponding to trifocal IOLs showed 3 mean peaks. Nevertheless, the progressive multifocal aspheric IOL showed 2 main areas, 1 corresponding to distance vision focus and the other including both intermediate and near vision foci. CONCLUSIONS: The results obtained in the present study suggest that the progressive multifocal aspheric IOL might be considered for cataract surgery. FINANCIAL DISCLOSURE: None of the authors has a financial or proprietary interest in any method or material mentioned.


Subject(s)
Lenses, Intraocular , Optics and Photonics , Cataract Extraction , Humans , Lens Implantation, Intraocular , Models, Theoretical , Optical Phenomena , Prosthesis Design , Refraction, Ocular/physiology
20.
Arq Bras Oftalmol ; 77(4): 233-7, 2014 Aug.
Article in English | MEDLINE | ID: mdl-25410175

ABSTRACT

PURPOSE: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. METHODS: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera) and the Pentacam HR (single Scheimpflug camera) systems. RESULTS: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured with the Galilei G4 and the Pentacam HR, respectively. The mean white-to-white distance measured was 11.84 ± 0.31 mm and 11.90 ± 0.43 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Mean pupil diameters were measured as 3.22 ± 0.58 mm and 3.22 ± 0.52 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Finally, the mean anterior chamber angle was 34.30 ± 2.86 degrees when it was measured with the Galilei G4, and 39.26 ± 2.85 degrees when measured with the Pentacam HR. A comparative analysis revealed that the Galilei G4 yielded a significantly lower (P<0.05) measurement for the anterior chamber depth, anterior chamber angle, and pupil diameter, than the Pentacam HR system. Comparable values (P>0.05) for both devices were obtained for the white-to-white distance measurements. CONCLUSION: The Galilei G4 and Pentacam HR Scheimpflug systems cannot be used interchangeably because they produce significant measurement differences.


Subject(s)
Anterior Chamber/anatomy & histology , Imaging, Three-Dimensional/instrumentation , Interferometry/instrumentation , Iris/anatomy & histology , Adult , Diagnostic Techniques, Ophthalmological , Humans , Photography/instrumentation , Pupil , Young Adult