Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Publication year range
1.
Rev Med Inst Mex Seguro Soc ; 55(1): 104-109, 2017.
Article in Spanish | MEDLINE | ID: mdl-28092255

ABSTRACT

One of the main scopes for institutions dedicated to preparing professionals in health is to increase their bioethics profile. To achieve this scope, these institutions have included lessons in bioethics into their study plans. Another way to increase the profile of the students, as the authors of this article propose, is creating bioethics seeds through a bioethics interest diagnostic on the students' preferences in their first year of the Justo Sierra University using a particular clinical case. The results found indicated that students show more interest in learning the physiopathology, diagnostics, and therapy of the pathologies than bioethics. The authors concluded that in order to increase this profile, the students are encouraged to discuss and reflect on bioethical situations that help them to construct their own opinion and decisions.


Incrementar el perfil bioético es uno de los objetivos principales que persiguen todas las instituciones dedicadas a la formación de profesionistas de salud. Para lograr esto se han creado varias estrategias de aprendizaje, como es el insertar la materia de Bioética en los currículos. Una estrategia más que se propone en este artículo es crear semilleros de bioética a través de un diagnóstico del interés hacia esta materia que muestran los estudiantes de primer año de la Escuela de Medicina de la Universidad Justo Sierra, utilizando como instrumento de medición la revisión de un caso clínico. Los resultados que se encontraron fue que los estudiantes presentan mayor interés en aprender la fisiopatología, diagnóstico y terapéutica de las patologías, reflejando un bajo interés por la bioética. En conclusión, para incrementar el perfil bioético de estudiantes en los ciclos básicos de sus estudios, es necesario fomentar la discusión y la reflexión de situaciones bioéticas que les permitan construirse una postura y toma de decisiones.


Subject(s)
Bioethics/education , Education, Medical, Undergraduate/methods , Education, Medical, Undergraduate/ethics , Humans , Mexico , Models, Educational , Students, Medical/psychology
2.
J Vis Exp ; (108): e52272, 2016 Feb 01.
Article in English | MEDLINE | ID: mdl-26863081

ABSTRACT

A simple Positron Emission Tomography (PET) prototype has been constructed to fully characterize its basic working principles. The PET prototype was created by coupling plastic scintillator crystals to photomultipliers or PMT's which are placed at opposing positions to detect two gamma rays emitted from a radioactive source, of which is placed in the geometric center of the PET set-up. The prototype consists of four detectors placed geometrically in a 20 cm diameter circle, and a radioactive source in the center. By moving the radioactive source centimeters from the center the system one is able to detect the displacement by measuring the time of flight difference between any two PMT's and, with this information, the system can calculate the virtual position in a graphical interface. In this way, the prototype reproduces the main principles of a PET system. It is capable to determine the real position of the source with intervals of 4 cm in 2 lines of detection taking less than 2 min.


Subject(s)
Image Processing, Computer-Assisted/methods , Positron-Emission Tomography/instrumentation , Equipment Design
3.
Nucleus (La Habana) ; (45): 36-32, ene.-jun. 2009. ilus, graf
Article in English | LILACS | ID: lil-738920

ABSTRACT

RESUMEN El daño radiacional en términos de desplazamientos atómicos en un típico detector de CZT empleado en aplicaciones de imagenología médica fue estudiado utilizando el método estadístico de Monte Carlo. Se tuvieron en cuenta todas las características estructurales y geométricas del detector, así como las diferentes energías de los fotones usualmente empleados en la aplicación. Considerando la aproximación clásica de Mott-McKinley-Feshbach se calcularon las secciones eficaces de desplazamiento, así como el número de desplazamientos por átomo para cada especie atómica presente en el material y para cada energía considerada de los fotones. Estos resultados se analizan y comparan entre sí y finalmente se establece la comparación entre el daño radiacional que tiene lugar en el detector de CZT con el que se manifiesta en un detector similar, pero fabricado con otros materiales semiconductores.


ABSTRACT Radiation damage in terms of atomic displacements in a typical CZT detector used in medical imaging applications was studied using the Monte Carlo statistical method. All detector structural and geometric features as well as different energies of the photons usually used in the application were taken into account. Considering the Mott-McKinley-Feshbach classical approach, effective cross sections of the displacements were calculated, including the number of displacements per atom for each atomic species present in the material and each photon energy considered. These results are analyzed and compared. Finally, the radiation damage on CZT detector is compared to that calculated in a similar detector manufactured with other semiconducting materials.

SELECTION OF CITATIONS
SEARCH DETAIL
...