Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Opt Express ; 11(9): 5122-5131, 2020 Sep 01.
Article in English | MEDLINE | ID: mdl-33014603

ABSTRACT

Objective: To investigate the DRS of ovine joint tissue to determine the optimal optical wavelengths for tissue differentiation and relate these wavelengths to the biomolecular composition of tissues. In this study, we combine machine learning with DRS for tissue classification and then look further at the weighting matrix of the classifier to further understand the key differentiating features. Methods: Supervised machine learning was used to analyse DRS data. After normalising the data, dimension reduction was achieved through multiclass Fisher's linear discriminant analysis (Multiclass FLDA) and classified with linear discriminant analysis (LDA). The classifier was first run with all the tissue types and the wavelength range 190 nm - 1081 nm. We analysed the weighting matrix of the classifier and then ran the classifier again, the first time using the ten highest weighted wavelengths and the second using only the single highest. Our method was applied to a dataset containing ovine joint tissue including cartilage, cortical and subchondral bone, fat, ligament, meniscus, and muscle. Results: It achieved a classification accuracy of 100% using the wavelength 190 nm - 1081 nm (2048 attributes) with an accuracy of 90% being present for 10 attributes with the exception of those with comparable compositions such as ligament and meniscus. An accuracy greater than 70% was achieved using a single wavelength, with the same exceptions. Conclusion: Multiclass FLDA combined with LDA is a viable technique for tissue identification from DRS data. The majority of differentiating features existed within the wavelength ranges 370-470 and 800-1010 nm. Focusing on key spectral regions means that a spectrometer with a narrower range can potentially be used, with less computational power needed for subsequent analysis.

2.
Biomed Opt Express ; 10(8): 3889-3898, 2019 Aug 01.
Article in English | MEDLINE | ID: mdl-31452982

ABSTRACT

Objective: To assess if incorporation of DRS sensing into real-time robotic surgery systems has merit. DRS as a technology is relatively simple, cost-effective and provides a non-contact approach to tissue differentiation. Methods: Supervised machine learning analysis of diffuse reflectance spectra was performed to classify human joint tissue that was collected from surgical procedures. Results: We have used supervised machine learning in the classification of a DRS human joint tissue data set and achieved classification accuracy in excess of 99%. Sensitivity for the various classes were; cartilage 99.7%, subchondral 99.2%, meniscus 100% and cancellous 100%. Full wavelength range is required for maximum classification accuracy. The wavelength resolution must be larger than 8nm. A SNR better than 10:1 was required to achieve a classification accuracy greater than 50%. The 800-900nm wavelength range gave the greatest accuracy amongst those investigated Conclusion: DRS is a viable method for differentiating human joint tissue and has the potential to be incorporated into robotic orthopaedic surgery.

SELECTION OF CITATIONS
SEARCH DETAIL
...