Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38584394

ABSTRACT

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Subject(s)
Catheter Ablation , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Arrhythmias, Cardiac/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Electric Countershock/adverse effects , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Treatment Outcome
2.
J Cardiovasc Electrophysiol ; 34(12): 2443-2451, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37767727

ABSTRACT

INTRODUCTION: Regardless of the catheter ablation (CA) for atrial fibrillation (AF) strategy, the role of early recurrences during the blanking period (BP) is still unclear. Our aim was to evaluate atrial tachyarrhythmias (ATAs) recurrences during the BP after CA with the laser-balloon (LB) technique. METHODS: Consecutive patients undergoing LBCA were enrolled. Primary outcome of the study was the overall crude ATA recurrence rate during the BP. ATA recurrences after the BP and in-hospital readmissions during the BP were deemed secondary outcomes. RESULTS: Two hundred and twenty-four patients underwent CA with the LB. Median age was 63.0 (55.5-69.5) years and 74.1% were males. 28.6% were persistent AF patients, and 34.8% of patients were followed up with a loop recorder. 15.6% of patients experienced at least an ATA recurrence during the BP. Male sex, chronic heart failure, persistent AF, and recurrences during the BP were found to be associated with long-term ATA recurrences. Recurrences during the BP remained associated with the outcome of interest at multivariate analysis (hazard ratio [HR] = 12.393, 95% confidence interval [95% CI] = 3.699-41.865, p < .001). An association over time was found between early and late recurrences, with 73.7%, 45.5%, and 10.8% of patients presenting with recurrences at 1-, 2-, and 3-month follow-up being free from recurrences after the BP, respectively. 8.0% of patients were readmitted during the BP: 4.5% for AF electrical cardioversion, and 1.8% for CA of other atrial arrhythmias; no redo CA was performed. CONCLUSION: After adjusting for confounders, ATA recurrences during the BP represent the most significant predictor of ATA recurrences after the BP, regardless of AF pattern.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Male , Middle Aged , Female , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Treatment Outcome , Time Factors , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence , Pulmonary Veins/surgery , Lasers
3.
Heart Rhythm ; 20(10): 1429-1435, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37481220

ABSTRACT

BACKGROUND: The impact of sex in clinical and procedural outcomes in leadless pacemaker (LPM) patients has not yet been investigated. OBJECTIVE: The purpose of this study was to investigate sex-related differences in patients undergoing LPM implantation. METHODS: Consecutive patients enrolled in the i-LEAPER registry were analyzed. Comparisons between sexes were performed within the overall cohort using an adjusted analysis with 1:1 propensity matching for age and comorbidities. The primary outcome was the comparison of major complication rates. Sex-related differences regarding electrical performance and all-cause mortality during follow-up were deemed secondary outcomes. RESULTS: In the overall population (n = 1179 patients; median age 80 years), 64.3% were men. After propensity matching, 738 patients with no significant baseline differences among groups were identified. During median follow-up of 25 [interquartile range 24-39] months, female sex was not associated with LPM-related major complications (hazard ratio [HR] 2.03; 95% confidence interval [CI] 0.70-5.84; P = .190) or all-cause mortality (HR 0.98; 95% CI 0.40-2.42; P = .960). LPM electrical performance results were comparable between groups, except for a higher pacing impedance in women at implant and during follow-up (24 months: 670 [550-800] Ω vs 616 [530-770] Ω; P = .014) that remained within normal limits. CONCLUSION: In a real-world setting, we found differences in sex-related referral patterns for LPM implantation with an underrepresentation of women, although major complication rate and LPM performance were comparable between sexes. Female patients showed higher impedance values, which had no impact on overall device performance. Electrical parameters remained within normal limits in both groups during the entire follow-up.

4.
Heart Rhythm ; 20(3): 395-404, 2023 03.
Article in English | MEDLINE | ID: mdl-36496135

ABSTRACT

BACKGROUND: Limited data on the real-world safety and efficacy of leadless pacemakers (LPMs) post-transvenous lead extraction (TLE) are available. OBJECTIVE: The purpose of this study was to assess the long-term safety and effectiveness of LPMs following TLE in comparison with LPMs de novo implantation. METHODS: Consecutive patients who underwent LPM implantation in 12 European centers joining the International LEAdless PacemakEr Registry were enrolled. The primary end point was the comparison of LPM-related complication rate at implantation and during follow-up (FU) between groups. Differences in electrical performance were deemed secondary outcomes. RESULTS: Of the 1179 patients enrolled, 15.6% underwent a previous TLE. During a median FU of 33 (interquartile range 24-47) months, LPM-related major complications and all-cause mortality did not differ between groups (TLE group: 1.6% and 5.4% vs de novo group: 2.2% and 7.8%; P = .785 and P = .288, respectively). Pacing threshold (PT) was higher in the TLE group at implantation and during FU, with very high PT (>2 V@0.24 ms) patients being more represented than in the de novo implantation group (5.4% vs 1.6 %; P = .004). When the LPM was deployed at a different right ventricular (RV) location than the one where the previous transvenous RV lead was extracted, a lower proportion of high PT (>1-2 V@0.24 ms) patients at implantation, 1-month FU, and 12-month FU (5.9% vs 18.2%, P = .012; 3.4% vs 12.9%, P = .026; and 4.3% vs 14.5%, P = .037, respectively) was found. CONCLUSION: LPMs showed a satisfactory safety and efficacy profile after TLE. Better electrical parameters were obtained when LPMs were implanted at a different RV location than the one where the previous transvenous RV lead was extracted.


Subject(s)
Pacemaker, Artificial , Humans , Treatment Outcome , Pacemaker, Artificial/adverse effects , Cardiac Pacing, Artificial/adverse effects , Registries , Equipment Design
5.
Int J Cardiol ; 371: 197-203, 2023 Jan 15.
Article in English | MEDLINE | ID: mdl-36115442

ABSTRACT

BACKGROUND: Age-related differences on leadless pacemaker (LP) are poorly described. Aim of this study was to compare clinical indications, periprocedural and mid-term device-associated outcomes in a large real-world cohort of LP patients, stratified by age at implantation. METHODS: Two cohorts of younger and older patients (≤50 and > 50 years old) were retrieved from the iLEAPER registry. The primary outcome was to compare the underlying indication why a LP was preferred over a transvenous PM across the two cohorts. Rates of peri-procedural and mid-term follow-up major complications as well as LP electrical performance were deemed secondary outcomes. RESULTS: 1154 patients were enrolled, with younger patients representing 6.2% of the entire cohort. Infective and vascular concerns were the most frequent characteristics that led to a LP implantation in the older cohort (45.8% vs 67.7%, p < 0.001; 4.2% vs 16.4%, p = 0.006), while patient preference was the leading cause to choose a LP in the younger (47.2% vs 5.6%, p < 0.001). Median overall procedural (52 [40-70] vs 50 [40-65] mins) and fluoroscopy time were similar in both groups. 4.3% of patients experienced periprocedural complications, without differences among groups. Threshold values were higher in the younger, both at discharge and at last follow-up (0.63 [0.5-0.9] vs 0.5 [0.38-0-7] V, p = 0.004). CONCLUSION: When considering LP indications, patient preference was more common in younger, while infective and vascular concerns were more frequent in the older cohort. Rates of device-related complications did not differ significantly. Younger patients tended to have a slightly higher pacing threshold at mid-term follow-up.


Subject(s)
Pacemaker, Artificial , Humans , Middle Aged , Treatment Outcome , Equipment Design , Pacemaker, Artificial/adverse effects , Time Factors , Cardiac Pacing, Artificial/adverse effects
6.
G Ital Cardiol (Rome) ; 23(2): 120-127, 2022 Feb.
Article in Italian | MEDLINE | ID: mdl-35343516

ABSTRACT

BACKGROUND: Transvenous pacing is nowadays the cornerstone of interventional management of bradyarrhythmias. It is still associated, however, with significant complications, mostly related to indwelling transvenous leads or device pocket. In order to reduce these complications, leadless pacemakers have been recently introduced into clinical practice, but no guidelines are yet available to indicate who are those patients that might benefit the most and whether leadless pacing should be preferred in the old or young population. This survey aims to describe the use of leadless pacemaker devices in a real-world setting. METHODS: Eleven arrhythmia centers in the Lombardy region (out of a total of 17 participating centers) responded to the proposed questionnaire regarding patient characteristics and indications to leadless pacing. RESULTS: Out of a total of 411 patients undergoing leadless pacing during 4.2 ± 0.98 years, the median age was 77 years, with 0.18% of patients having less than 18 years, 29.9% 18-65 years, 34.3% 65-80 years and 35.6% >80 years. The most common indication was slow atrial fibrillation (49% of patients), followed by atrioventricular block and sinoatrial dysfunction. Two centers reported in-hospital complications. CONCLUSIONS: Leadless pacemakers proved to be a safe pacing strategy actually destined mostly to elderly patients.


Subject(s)
Atrial Fibrillation , Atrioventricular Block , Pacemaker, Artificial , Aged , Atrioventricular Block/therapy , Equipment Design , Humans , Surveys and Questionnaires
7.
Hellenic J Cardiol ; 65: 1-7, 2022.
Article in English | MEDLINE | ID: mdl-35331905

ABSTRACT

OBJECTIVE: Cryoballoon (CB) and laser-balloon (LB) catheter ablation (CA) has been demonstrated to achieve durable and effective pulmonary vein isolation (PVI). Only one head-to-head comparison with an intermittent rhythm monitor strategy is currently available. The aim of this study was to compare acute and long-term outcomes of CB and LB atrial fibrillation ablation procedures, by using a continuous rhythm monitoring strategy. METHODS: This was a prospective two-arm nonrandomized propensity-matched observational trial that compared the outcomes of atrial fibrillation (AF) ablation using LB and CB techniques. To evaluate AF recurrences, an implantable cardiac monitor (ICM) was implanted before hospital discharge to detect atrial tachyarrhythmia (ATA) recurrences. RESULTS: A total of 110 propensity-matched patients undergoing AF ablation with an LB (n = 55) or with a CB system (n = 55) were enrolled (paroxysmal AF 57.3%). Procedural time (LB: 87 [73-104] vs. CB 90 [70-130] min; p = 0.264) and fluoroscopy time did not differ. No differences in ATA recurrences were observed at 12 months (LB-30.9% vs. CB-29.1% and LB-45.5% vs. CB-38.2%; log-rank 0.539). As for AF burden, the 12-month median was 0 [0-1] vs. 0 [0-3]% (p = 0.127) in the LB and CB groups, respectively. When considering only PeAF patients, the median 12-month ATA burden was 26 [18.5-40.5] vs. 29 [26-35]% (p = 0.919) for the LB and CB patients, respectively. CONCLUSION: In a propensity-matched cohort undergoing AF ablation, arrhythmia outcomes assessed by continuous rhythm monitoring did not differ between LB and CB, with an overall low ATA burden. The only predictor of recurrences was persistent AF. There was no difference in procedure or fluoroscopy time.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/methods , Cryosurgery/methods , Humans , Lasers , Prospective Studies , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
8.
Medicina (Kaunas) ; 59(1)2022 Dec 28.
Article in English | MEDLINE | ID: mdl-36676690

ABSTRACT

Background. Data on leadless pacemaker (LPM) implantation in an emergency setting are currently lacking. Objective. We aimed to investigate the feasibility of LPM implantation for emergency bradyarrhythmia, in patients referred for urgent PM implantation, in a large, multicenter, real-world cohort of LPM recipients. Methods. Two cohorts of LPM patients, stratified according to the LPM implantation scenario (patients admitted from the emergency department (ED+) vs. elective patients (ED−)) were retrieved from the iLEAPER registry. The primary outcome of the study was a comparison of the peri-procedural complications between the groups. The rates of peri-procedural characteristics (overall procedural and fluoroscopic duration) were deemed secondary outcomes. Results. A total of 1154 patients were enrolled in this project, with patients implanted due to an urgent bradyarrhythmia (ED+) representing 6.2% of the entire cohort. Slow atrial fibrillation and complete + advanced atrioventricular blocks were more frequent in the ED+ cohort (76.3% for ED+ vs. 49.7% for ED−, p = 0.025; 37.5% vs. 27.3%, p = 0.027, respectively). The overall procedural times were longer in the ED+ cohort (60 (45−80) mins vs. 50 (40−65) mins, p < 0.001), showing higher rates of temporary pacing (94.4% for ED+ vs. 28.9% for ED−, p < 0.001). Emergency LPM implantation was not correlated with an increase in the rate of major complications compared to the control group (6.9% ED+ vs. 4.2% ED−, p = 0.244). Conclusion. LPM implantation is a feasible procedure for the treatment of severe bradyarrhythmia in an urgent setting. Urgent LPM implantation was not correlated with an increase in the rate of major complications compared to the control group, but it was associated with longer procedural times.


Subject(s)
Atrial Fibrillation , Pacemaker, Artificial , Humans , Bradycardia/therapy , Atrial Fibrillation/therapy , Treatment Outcome
9.
Europace ; 23(9): 1380-1390, 2021 09 08.
Article in English | MEDLINE | ID: mdl-33837418

ABSTRACT

AIMS: Balloon-based technologies have been developed to simplify catheter ablation of atrial fibrillation (AF), to improve the clinical outcome of the procedure and to achieve durable pulmonary vein isolation (PVI). The objective of this study is to evaluate the safety and efficacy of second-generation laser balloon (LB2) ablation in the treatment of AF using a continuous cardiac rhythm monitoring strategy. Atrial tachyarrhythmias (ATas) recurrences were assessed with implantable cardiac monitors (ICMs) or devices. METHODS AND RESULTS: All patients underwent LB2 ablation procedure. The primary endpoint was the first recurrence of any, >5.5 and >24 h duration ATas after the blanking period (90 days). In-hospital visits were performed at 3, 6, and 12 months. Seventy-three patients (68% male, mean age 59.8 ± 11.3) were included in the study. The average procedure, fluoroscopy, and laser ablation times were 81.5 ± 30.1, 21.5 ± 12.4, and 33.8 ± 9.7, respectively. All PVs were isolated using the LB2 with no need of touch-up using focal catheters. No major complications occurred during or after the procedures. The one-year freedom from recurrences was 66.9% (95% CI: 57.0-76.7%), 81.0% (69.5-88.5%), and 86.8% (76.1-92.9%) considering any, 5.5-h and 24-h cut-off duration, respectively. At 3, 6, and 12 months, any ATas was recorded in 22%, 32%, and 25% of patients, with a ≥5% arrhythmic burden documented in 4%, 5%, and 3%, respectively. Few patients reported AF-related symptoms (7%, 8%, and 5%). CONCLUSION: LB2 ablation is a safe and effective procedure, showing a high freedom from recurrences and low arrhythmic burden as documented by a continuous rhythm monitoring strategy.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Laser Therapy , Pulmonary Veins , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Female , Humans , Male , Middle Aged , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
10.
J Cardiovasc Electrophysiol ; 32(4): 933-940, 2021 04.
Article in English | MEDLINE | ID: mdl-33694210

ABSTRACT

BACKGROUND: The success rate after cryoballoon ablation (CB-A) performed for paroxysmal atrial fibrillation (PAF) might be overestimated by traditional noninvasive monitoring techniques. The purpose of this study was to evaluate the mid-term outcome of CB-A in patients with PAF implanted with an implantable loop recorder (ILR) after the procedure. METHODS: Between January 2017 and March 2019, all patients who underwent CB-A for PAF and who were subsequently implanted with an ILR were retrospectively included. All devices were equipped with remote monitoring. All ILR-documented atrial tachycardia (AT) or AF episodes ≥ 6 min were considered as recurrence; both true and false episodes were collected. A 3-month post-procedural blanking period (BP) was applied. RESULTS: A total of 102 patients (77 men, mean age 60.6 ± 9.6 years) who underwent pulmonary vein isolation (PVI) by CB-A were included; mean time from first diagnosis of AF to PVI was 51.5 ± 46.9 months. Mean follow-up was 29.3 ± 8.1 months; at 12-month follow-up, the success rate was 65.7%, while at 2-year follow-up, freedom from AT/AF recurrences was achieved in 59.3% of the patients. In the follow-up, a total of 4987 ECG strips were analyzed; true-positive episodes were confirmed in 2026 cases (40.6%), whereas 2961 episodes (59.4%) were considered false-positive. CONCLUSION: In patients with PAF implanted with an ILR, CB-A results in freedom from any AT/AF recurrence in 65.7% of patients at 12-month follow-up and in 59.3% of patients when evaluated at 2-year. Careful adjudication of all ILR-documented AF episodes is required to avoid misdiagnosis.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Cryosurgery/adverse effects , Electrocardiography , Humans , Male , Middle Aged , Pulmonary Veins/surgery , Recurrence , Retrospective Studies , Treatment Outcome
11.
J Cardiovasc Pharmacol Ther ; 25(3): 219-225, 2020 05.
Article in English | MEDLINE | ID: mdl-31868001

ABSTRACT

AIM: To evaluate outcomes related to antiplatelet therapy in patients with ST-elevation myocardial infarction (STEMI) admitted to the San Gerardo Hospital in Monza, an extracorporeal membrane oxygenation (ECMO) reference center in the Monza-Brianza area. METHODS: This retrospective study enrolled patients with STEMI hospitalized between 2013 and 2017. RESULTS: This study included 653 patients (mean age: 67.5 years, 71% male). Across the study period, ticagrelor use showed consistent increases, from 22% of patients during 2013 to 85% in 2017. Cardiac arrest prehospitalization occurred in 100 patients (15.3%), either at home (n = 85, 13.0%) or during transfer (n = 15, 2.3%); 46 patients underwent ECMO for refractory cardiac arrest. Rates of 90-day survival (hazard ratio [HR]: 2.4, 95% confidence interval [CI]: 1.3-4.4, P = .004) and ST resolution (odds ratio [OR]: 2.5, 95% CI: 1.6-4.1, P = .000) were higher with ticagrelor than with other antiplatelet agents. When analyzed by each agent, patients on ticagrelor had longer survival (HR: 0.4, 95% CI: 0.2-0.8, P = .008) than patients on clopidogrel and more frequent ST resolution than those on clopidogrel or prasugrel (OR: 0.4, 95% CI: 0.2-0.7, P = .002 and OR: 0.4, 95% CI: 0.2-0.7, P = .006). There was no difference in mortality between ticagrelor and prasugrel. CONCLUSIONS: Changes in the treatment of high-risk patients with STEMI over time are in line with changes in treatment guidelines. In these patients, ticagrelor is associated with significantly improved 90-day mortality compared with clopidogrel.


Subject(s)
Clopidogrel/therapeutic use , Extracorporeal Membrane Oxygenation , Platelet Aggregation Inhibitors/therapeutic use , ST Elevation Myocardial Infarction/therapy , Ticagrelor/therapeutic use , Aged , Aged, 80 and over , Clopidogrel/adverse effects , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/mortality , Female , Humans , Italy , Male , Middle Aged , Platelet Aggregation Inhibitors/adverse effects , Retrospective Studies , Risk Assessment , Risk Factors , ST Elevation Myocardial Infarction/diagnosis , ST Elevation Myocardial Infarction/mortality , ST Elevation Myocardial Infarction/physiopathology , Ticagrelor/adverse effects , Time Factors , Treatment Outcome
12.
Pacing Clin Electrophysiol ; 42(11): 1489-1492, 2019 11.
Article in English | MEDLINE | ID: mdl-31222756

ABSTRACT

We describe the world's first fully leadless cardiac resynchronization therapy pacing implant with transseptal approach, in a patient with pacemaker dependency, atrial fibrillation, ischemic hypokinetic cardiomyopathy, and a history of pocket infections. After lead extraction, we implanted a MicraTranscathether Pacing System® (Medtronic, Minneapolis, MN, USA) as the sole right ventricular pacemaker, and the WISECRT system (EBR Systems, Sunnyvale, CA, USA) to provide biventricular pacing. We performed the WISECRT implant procedure using the transseptal approach given the presence of a prosthetic aortic mechanical valve, achieving satisfactory periprocedural results.


Subject(s)
Cardiac Resynchronization Therapy Devices , Cardiac Resynchronization Therapy , Pacemaker, Artificial , Aged, 80 and over , Humans , Male , Prosthesis Design , Prosthesis Implantation/methods , Veins
13.
J Hypertens ; 25(4): 793-7, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17351371

ABSTRACT

OBJECTIVE: Systemic sclerosis (SSc) is characterized by an altered nitric oxide (NO): endothelin I ratio and by endothelial dysfunction. AIMS: To verify the effects of prostaglandin E1 (PGE1) alpha-cyclodestrin treatment on endothelial function, quantified as flow-mediated dilation (FMD) of the radial artery. METHODS: In 16 women with SSc (age 57 +/- 2.7 years, means +/- SE) in whom a diagnosis of SSc had been made several years earlier (7.1 +/- 1.2 years), FMD was evaluated by an echotracking technique on the radial artery, using trinitroglycerin vasodilation as a non-endothelial measure of the vessel's ability to increase its diameter maximally. FMD was evaluated after 4 months washout period and after 4 months cyclic infusion of PGE1 alpha-cyclodestrin. Expired NO was measured at the same time. RESULTS: PGE1 alpha-cyclodestrin cyclic infusions did not modify systolic and diastolic blood pressure, heart rate or trinitroglycerin radial artery vasodilation. On the other hand, it induced a marked and significant increase in FMD of the radial artery, which was also accompanied by an increase in blood flow and expired NO. CONCLUSIONS: Endothelial dysfunction and reduced FMD associated with SSc are improved by cyclic treatment with PGE1 alpha-cyclodestrin. This effect occurs together with a concomitant increase in expired NO, suggesting its direct positive influence on endothelial function. It may also partly explain the clinical beneficial effect of the drug in SSc.


Subject(s)
Alprostadil/analogs & derivatives , Endothelium, Vascular/drug effects , Endothelium, Vascular/physiopathology , Radial Artery/drug effects , Scleroderma, Systemic/drug therapy , Scleroderma, Systemic/physiopathology , alpha-Cyclodextrins/therapeutic use , Alprostadil/therapeutic use , Analysis of Variance , Blood Flow Velocity/drug effects , Blood Pressure/drug effects , Endothelium, Vascular/metabolism , Exhalation , Female , Heart Rate/drug effects , Humans , Infusions, Intravenous , Middle Aged , Nitric Oxide/analysis , Radial Artery/physiopathology , Regional Blood Flow/drug effects , Scleroderma, Systemic/metabolism , Treatment Outcome , Vasodilation/drug effects , Vasodilator Agents/therapeutic use
SELECTION OF CITATIONS
SEARCH DETAIL
...