1.
Talanta ; 63(5): 1183-91, 2004 Aug 08.
Article in English | MEDLINE | ID: mdl-18969547

ABSTRACT

A new approach has been developed and tested for the urgent analysis of dioxins in samples of air-dust filters originating from catastrophe emissions. The procedure consists of a fast extraction of the sample with microwave solvent extraction (MASE) and acetone as solvent followed by a fast cleanup of the extract with normal phase coupled column liquid chromatography (LC/LC). The multi-dimensional LC/LC system employs a 50 mm x4.6 mm i.d. column packed with 3mum silica and a 150 mm x4.6 mm i.d. column packed with 5mum PYE as the first and second analytical column, respectively. Iso-hexane is used on both columns to perform cleanup and dichloromethane to perform efficient back-flush elution of the compounds from the second column. The obtained polarity-based separation in the first dimension and molecular-structure based separation in the second dimension provides a fast and powerful cleanup. Validation was done by analysing samples of homemade RIVM air-dust with aged residues (n=8, spiking level about 15pgmg(-1) per compound) of dioxins/furans and samples of reference Urban Dust SRM 1649a (n=4) with both the new approach and the existing conventional procedure and were instrumentally analyzed with capillary gas chromatography and high resolution mass spectrometric detection (GC/HRMS). In comparison to the existing conventional procedure, the new approach reduces sample processing from several days to several hours per sample. As regards the aged-residue air-dust samples, the new method shows a good accuracy, precision and high selectivity providing a performance in good agreement with the existing procedure. In SRM air-dust, the concentration of a few compounds obtained by the new method was below (10-50%) the certified value.

2.
J Chromatogr A ; 975(1): 165-73, 2002 Oct 25.
Article in English | MEDLINE | ID: mdl-12458757

ABSTRACT

Two less laborious extraction methods, viz. (i) a simplified liquid extraction using light petroleum or (ii) microwave-assisted solvent extraction (MASE), for the analysis of polycyclic aromatic hydrocarbons (PAHs) in samples of the compost worm Eisenia andrei, were compared with a reference method. After extraction and concentration, analytical methodology consisted of a cleanup of (part) of the extract with high-performance gel permeation chromatography (HPGPC) and instrumental analysis of 15 PAHs with reversed-phase liquid chromatography with fluorescence detection (RPLC-FLD). Comparison of the methods was done by analysing samples with incurred residues (n=15, each method) originating from an experiment in which worms were exposed to a soil contaminated with PAHs. Simultaneously, the performance of the total lipid determination of each method was established. Evaluation of the data by means of principal component analysis (PCA) and analysis of variance (ANOVA) revealed that the performance of the light petroleum method for both the extraction of PAHs (concentration range 1-30 ng/g) and lipid content corresponds very well with the reference method. Compared to the reference method, the MASE method yielded somewhat lower concentrations for the less volatile PAHs, e.g., dibenzo[ah]anthracene and benzo[ghi]perylene and provided a significant higher amount of co-extracted material.


Subject(s)
Oligochaeta/chemistry , Polycyclic Aromatic Hydrocarbons/analysis , Animals , Chromatography, Gel , Polycyclic Aromatic Hydrocarbons/isolation & purification
3.
J Chromatogr A ; 926(1): 113-25, 2001 Aug 10.
Article in English | MEDLINE | ID: mdl-11554405

ABSTRACT

This study investigated the effects of matrix interferences on the analytical performance of a triple quadrupole mass spectrometric (MS-MS) detector coupled to various reversed-phase liquid chromatographic (LC) modes for the on-line determination of various types of acidic herbicides in water using external calibration for quantification of the analytes tested at a level of 0.4 microg/l. The LC modes included (i) a single-column configuration (LC), (ii) precolumn switching (PC-LC) and (iii) coupled-column LC (LC-LC). As regards detection, electrospray (ESI) and atmospheric pressure chemical ionization (APCI) in both positive (PI) and negative (NI) ionization modes were examined. Salinity and dissolved organic carbon (DOC) were selected as interferences to study matrix effects in this type of analysis. Therefore, Milli-Q and tap water samples both fortified with 12 mg/l DOC and spiked with sulfometuron-methyl, bentazone, bromoxynil, 2-methyl-4-chlorophenoxyacetic acid, and 2-methyl-4-chlorophenoxypropionic acid at a level of about 0.4 microg/l were analyzed with the various LC-MS approaches. Direct sample injection was performed with volumes of 0.25 ml or 2.0 ml on a column of 2.1 mm I.D. or 4.6 mm I.D. for the ESI and APCI modes, respectively. The recovery data were used to compare and evaluate the analytical performance of the various LC approaches. As regards matrix effects, the salinity provided a dramatic decrease in response for early eluting analytes (k value of about 1) when using the LC mode. Both PC-LC and LC-LC efficiently eliminated this problem. The high DOC content hardly effected the responses of analytes in the ESI mode, while in most cases the responses increased when using APCI-MS-MS detection. Of all the tested configurations, LC-LC-ESI-MS-MS with the column combination Discovery C18/ABZ+ was the most favorable as regards elimination of matrix effects and provided reliable quantification of all compounds using external calibration at the tested low level. The major observed effects were verified with statistical evaluation of the data employing backwards ordinary least-square regression. All tested column-switching modes hyphenated to ESI- or APCI-MS-MS allowed the on-line multi-residue analysis of acidic pesticides in the reference water down to a level of 0.1 microg/l in less than 10 min, emphasizing the feasibility of such an approach in this field of analysis.


Subject(s)
Chromatography, Liquid/methods , Hydrogen-Ion Concentration , Mass Spectrometry/methods , Pesticides/analysis , Water Pollutants, Chemical/analysis , Calibration , Reference Standards