Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Article in English, Spanish | MEDLINE | ID: mdl-38521441

ABSTRACT

INTRODUCTION AND OBJECTIVES: Most of the complications associated with acute and symptomatic bradyarrhythmia (ASB) occur in the time from diagnosis to permanent pacemaker implantation (PPI). We aimed to evaluate the outcomes of an urgent 24/7 PPI service (PPI-24/7) for patients with ASB. METHODS: A total of 664 patients undergoing first-time PPI for ASB were prospectively assessed during 2 periods of identical length (18 months): 341 patients who underwent the procedure during working hours only (PPI-WH), and 323 patients who underwent the procedure after the implementation of the PPI-24/7 service. The primary safety endpoint was established as the cumulative 180-day incidence of complications related to the index arrhythmia and device implant. The primary efficacy endpoint was determined as the average number of hospital stays per patient. RESULTS: The PPI-24/7 period was associated with a significant shortening of the time from diagnosis to implantation (median [interquartile range]): 3hours [2-6] vs 16 [5-21]). The cumulative incidence of patients with complications at 180 days was lower in the PPI-24/7 period: 9% vs 17% (adjusted odds ratio, 0.5; P=.002), due to a significant reduction in preimplant complications: 2.5% vs 12% (P <.001). The average number of hospital stays was reduced by 2 per patient in the PPI-24/7 period (nonparametric P <.001). PPI-24/7 implants performed outside working hours (n=178) were safe, with a 180-day cumulative incidence in procedure-related complications of 3.9%. CONCLUSIONS: Among patients with ASB, PPI-24/7 was associated with a significant reduction in patient morbidity and efficient hospital resource use.

2.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37669318

ABSTRACT

AIMS: Same-day discharge (SDD) is feasible after pulmonary vein isolation (PVI). We aim to compare prospectively cryoballoon (CRYO) vs. radiofrequency (RF) ablation in a systematic SDD programme. METHODS AND RESULTS: We prospectively analysed the 617 scheduled PVI performed consecutively at our institution (n = 377 CRYO, n = 240 RF) from 1 April 2019 to 31 December 2022 within a systematic programme of SDD. The feasibility of SDD, the 10-day incidence of urgent/unplanned medical care after discharge (UUC-10), and the cost per procedure due to hospital resource use were studied. The 100 procedures performed during the previous year, in which patients were systematically hospitalized, were used as a control group. Same-day discharge was achieved in 585/617 (95%) procedures, with a significant trend towards a higher monthly SDD rate from 2019 to 2022 (P = 0.03). The frequency of SDD was similar in CRYO (356/377; 94%) vs. RF (229/240; 95%). After SDD, the UUC-10 was 66/585 (11.3%), being similar for CRYO (41/356; 11.5%) and RF (25/229; 10.9%); P = 0.8 (log-rank test). Of these, 10 patients were re-hospitalized, with an identical rate in CRYO-treated (6/356; 1.7%) and RF-treated (4/229; 1.7%) patients and owing to similar causes (4 haematomas, 4 pericarditis, and 2 symptomatic sinus node dysfunction). Same-day discharge was associated with an average savings per procedure of 63% (P < 0.001), but no differences were found between the CRYO and RF (P = 0.8). CONCLUSION: In a systematic SDD programme, feasibility (95%, increasing over time), safety (11% UUC-10, 1.7% re-hospitalizations), and savings (63% per procedure) were similar for CRYO and RF ablation procedures.


Subject(s)
Ablation Techniques , Pulmonary Veins , Radiofrequency Ablation , Humans , Patient Discharge , Pulmonary Veins/surgery , Hospitalization
5.
Am J Cardiol ; 136: 87-93, 2020 12 01.
Article in English | MEDLINE | ID: mdl-32946863

ABSTRACT

Although radiofrequency catheter ablation (RFCA) is indicated in electrical storm (ES) refractory to antiarrhythmic drugs, its most appropriate timing has not been determined. Our objective is to analyse the impact of the timing of RFCA on 30-day mortality in patients with ES and previous scar-related systolic dysfunction. In this multi-centre study, we analysed 104 patients (age: 72 ± 10, left ventricular ejection fraction: 30 ± 6%) attended consecutively due to an ES caused by monomorphic ventricular tachycardia. Sixty-four subjects were treated with RFCA (mean time from admission = 83 ± 67 hours) and 40 were not. Upon admission 25 (24%) individuals had severe heart failure. Mortality rate at 30 days was 24 (23%) patients. RFCA was associated with a reduction of 30-day mortality (hazard ratio = 0.2; p = 0.008). After showing a positive correlation between the time of the RFCA (hours) and survival at 30 days (C-statistic = 0.77; p <0.001), we found that only subjects ablated >48 hours after admission had lower mortality at 30 days than those treated conservatively: 38% (no RFCA) versus 30% (RFCA ≤48 hours) versus 7% (RFCA >48 hours) (adjusted hazard ratio for RFCA >48 hours vs others = 0.2; p = 0.007). Among the patients ablated, those who were non-inducible had lower 30-day mortality: 8% versus 29% (p = 0.03). Extracorporeal membrane oxygenation was associated with a higher rate of non-inducibility in RFCA >48 hours (100% vs 76%; p = 0.03), but not in RFCA ≤48 hours (60% vs 60%; p = 1). In conclusion, among high-risk patients with ES, RFCA performed >48 hours after admission is associated with a reduction in 30-day mortality. In such subjects, the probability of successful RFCA increases when performed under extracorporeal membrane oxygenation support.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular/surgery , Aged , Aged, 80 and over , Catheter Ablation/methods , Cicatrix/complications , Female , Humans , Male , Middle Aged , Prognosis , Retrospective Studies , Survival Rate , Tachycardia, Ventricular/complications , Tachycardia, Ventricular/mortality , Time Factors , Ventricular Dysfunction, Left/complications , Ventricular Dysfunction, Left/etiology
6.
Rev. esp. cardiol. (Ed. impr.) ; 72(12): 1020-1030, dic. 2019. tab
Article in Spanish | IBECS | ID: ibc-190766

ABSTRACT

Introducción y objetivos: Se describen los resultados en España de la segunda encuesta de la Sociedad Europea de Cardiología sobre terapia de resincronización cardiaca (CRT-Survey II) y se comparan con los de los demás países participantes. Métodos: Pacientes a los que se implantó un dispositivo de terapia de resincronización cardiaca entre octubre de 2015 y diciembre de 2016 en 36 centros participantes. Se recogieron datos sobre las características basales de los pacientes y del implante, y un seguimiento a corto plazo hasta el alta hospitalaria. Resultados: La tasa de éxito del implante fue del 95,9%. La mediana [intervalo intercuartílico] de implantes anuales/centro en España fue significativamente menor que en los demás países participantes: 30 [21-50] frente a 55 [33-100] implantes/año (p=0,00003). En los centros españoles hubo una menor proporción de pacientes de edad ≥ 75 años (el 27,9 frente al 32,4%; p=0,0071), una mayor proporción de pacientes en clase funcional II de la New York Heart Association (el 46,9 frente al 36,9%; p <0,00001) y un mayor porcentaje de pacientes con criterios electrocardiográficos de bloqueo de rama izquierda (el 82,9 frente al 74,6%; p <0,00001). La media de la estancia hospitalaria fue menor en los centros españoles (5,8+/-8,5 frente a 6,4+/-11,6; p <0,00001) y una mayor proporción de pacientes recibieron un cable de ventrículo izquierdo cuadripolar (el 74 frente al 56%; p <0,00001) y fueron seguidos a distancia (el 55,8 frente al 27,7%; p <0,00001). Conclusiones: La encuesta CRT-Survey II muestra que en España hay una menor proporción de pacientes de 75 o más años que reciben un dispositivo de terapia de resincronización cardiaca, una mayor proporción de pacientes en clase funcional II de la New York Heart Association, con bloqueo completo de la rama izquierda del haz de His y con seguimiento a distancia, con estancias hospitalarias significativamente menores


Introduction and objectives: We describe the results for Spain of the Second European Cardiac Resynchronization Therapy Survey (CRT-Survey II) and compare them with those of the other participating countries. Methods: We included patients undergoing CRT device implantation between October 2015 and December 2016 in 36 participating Spanish centers. We registered the patients' baseline characteristics, implant procedure data, and short-term follow-up information until hospital discharge. Results: Implant success was achieved in 95.9%. The median [interquartile range] annual implantation rate by center was significantly lower in Spain than in the other participating countries: 30 implants/y [21-50] vs 55 implants/y [33-100]; P=.00003. In Spanish centers, there was a lower proportion of patients ≥ 75 years (27.9% vs 32.4%; P=.0071), a higher proportion in NYHA class II (46.9% vs 36.9%, P <.00001), and a higher percentage with electrocardiographic criteria of left bundle branch block (82.9% vs 74.6%; P <.00001). The mean length of hospital stay was significantly lower in Spanish centers (5.8+/-8.5 days vs 6.4+/-11.6; P <.00001). Spanish patients were more likely to receive a quadripolar LV lead (74% vs 56%, P <.00001) and to be followed up by remote monitoring (55.8% vs 27.7%; P <.00001). Conclusions: The CRT-Survey II shows that, compared with other participating countries, fewer patients in Spain aged ≥ 75 years received a CRT device, while more patients were in New York Heart Association functional class II and had left bundle branch block. In addition, the length of hospital stay was shorter, and there was greater use of quadripolar LV leads and remote CRT monitoring


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Cardiac Resynchronization Therapy/methods , Heart Failure/therapy , Arrhythmias, Cardiac/therapy , Health Care Surveys/statistics & numerical data , Arrhythmias, Cardiac/epidemiology , Heart Failure/epidemiology , Electrocardiography/methods , Spain/epidemiology , Europe/epidemiology , Retrospective Studies
7.
Rev Esp Cardiol (Engl Ed) ; 72(12): 1020-1030, 2019 Dec.
Article in English, Spanish | MEDLINE | ID: mdl-30935899

ABSTRACT

INTRODUCTION AND OBJECTIVES: We describe the results for Spain of the Second European Cardiac Resynchronization Therapy Survey (CRT-Survey II) and compare them with those of the other participating countries. METHODS: We included patients undergoing CRT device implantation between October 2015 and December 2016 in 36 participating Spanish centers. We registered the patients' baseline characteristics, implant procedure data, and short-term follow-up information until hospital discharge. RESULTS: Implant success was achieved in 95.9%. The median [interquartile range] annual implantation rate by center was significantly lower in Spain than in the other participating countries: 30 implants/y [21-50] vs 55 implants/y [33-100]; P=.00003. In Spanish centers, there was a lower proportion of patients ≥ 75 years (27.9% vs 32.4%; P=.0071), a higher proportion in New York Heart Association functional class II (46.9% vs 36.9%; P <.00001), and a higher percentage with electrocardiographic criteria of left bundle branch block (82.9% vs 74.6%; P <.00001). The mean length of hospital stay was significantly lower in Spanish centers (5.8±8.5 days vs 6.4±11.6; P <.00001). Spanish patients were more likely to receive a quadripolar LV lead (74% vs 56%; P <.00001) and to be followed up by remote monitoring (55.8% vs 27.7%; P <.00001). CONCLUSIONS: The CRT-Survey II shows that, compared with other participating countries, fewer patients in Spain aged ≥ 75 years received a CRT device, while more patients were in New York Heart Association functional class II and had left bundle branch block. In addition, the length of hospital stay was shorter, and there was greater use of quadripolar LV leads and remote CRT monitoring.


Subject(s)
Arrhythmias, Cardiac/therapy , Cardiac Resynchronization Therapy/statistics & numerical data , Surveys and Questionnaires , Aged , Arrhythmias, Cardiac/epidemiology , Electrocardiography , Europe/epidemiology , Female , Humans , Male , Middle Aged , Morbidity/trends , Retrospective Studies , Spain/epidemiology
8.
J Interv Card Electrophysiol ; 52(1): 69-76, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29557531

ABSTRACT

INTRODUCTION: Among implantable cardioverter-defibrillator (ICD) patients, a substantial proportion of syncopes are due to fast ventricular tachycardias (FVTs). In the experimental models of ventricular tachycardias, the arterial vasoconstriction plays an important role in recovering the arterial pressure. Since beta-blockers increase vascular resistance, we hypothesized that beta-blockers could reduce the occurrence of syncope due to FVTs. Our objective was to determine the relationship between the beta-blocker therapy and the incidence of syncope in FVT (cycle length [CL] 250-320 ms) occurring in ICD patients. Slow VTs were excluded because of the lack of symptoms and VF episodes because of the small number. METHODS AND RESULTS: In this multicenter study, 226 patients (LVEF 31 ± 10%) with single-chamber ICDs were followed. FVT programming was standardized, including antitachycardia pacing (ATP) as initial therapy. Symptoms were correlated with ICD-stored episode data of FVTs. The beta-blocker therapy was determined at each FVT presentation. We analyzed 289 FVTs (CL 291 ± 21 ms; 77% under beta-blockers; median of the duration:8 s) occurring consecutively in 52 ICD patients. The frequency of FVT-related syncope was 22 (7.6%). Beta-blockers were associated with a lower heart rate preceding FVT (85 ± 22 vs. 94 ± 23 bpm; p = 0.009), a higher ATP effectiveness (86 vs. 57%; p < 0.001), a lower duration of episodes (8 [2] vs. 10 [14] s; p < 0.001), and a lower incidence of FVT-related syncope (4.5 vs. 18%; p < 0.001). By logistic regression, a FVT > 8 s (OR = 21; p = 0.003) and the beta-blocker therapy (OR = 0.3; p = 0.012) were found as independent predictors of syncope. CONCLUSION: Among ICD patients with left ventricular dysfunction, beta-blockers are associated with a lower incidence of FVT-related syncope.


Subject(s)
Adrenergic beta-Antagonists/therapeutic use , Defibrillators, Implantable/statistics & numerical data , Syncope/prevention & control , Tachycardia, Ventricular/therapy , Ventricular Dysfunction, Left/drug therapy , Aged , Cohort Studies , Dose-Response Relationship, Drug , Electrocardiography/methods , Female , Humans , Logistic Models , Male , Middle Aged , Prognosis , ROC Curve , Retrospective Studies , Risk Assessment , Severity of Illness Index , Survival Rate , Syncope/drug therapy , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/mortality , Treatment Outcome , Ventricular Dysfunction, Left/diagnostic imaging
9.
J Cardiovasc Electrophysiol ; 24(12): 1375-82, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24015729

ABSTRACT

INTRODUCTION: Fast ventricular tachycardias (FVT) are less likely to be terminated by antitachycardia pacing (ATP). No information is available regarding the ability of far-field electrogram (Ff-EG) morphology (Ff-EGm) in predicting the result of the subsequent ATP. Our objective is to determine the relationship between Ff-EGm and ATP efficacy. METHODS AND RESULTS: In this multicenter study we analyzed 289 FVT (cycle length [CL]: 250-320 milliseconds) occurring consecutively in 52 ICD patients with Medtronic devices (LVEF: 37 ± 6; pacing site: right ventricular apex). FVT programming was standardized, including a single ATP burst as initial therapy. The configuration of Ff-EG was HVA versus HVB. FVTs were classified in QFVT or non-QFVT according to the presence or absence of a negative initial deflection in the Ff-EG. The mean CL was 291 ± 24 milliseconds. We observed 4 Ff-EGm: QS (n = 14, 5%), QR (n = 158, 55%), R (n = 93, 32%), and RS (n = 24, 8%). The ATP effectiveness was 80% (86% in QS, 85% in QR, 74% in R, 62% in RS). The frequency of successful ATP was higher in QFVT: 86 versus 71% (P = 0.002). By logistic regression analysis, a QFVT pattern (OR = 2.3; P = 0.015) remained as an independent predictor of effective ATP. ATP was safer in QFVTs, the frequencies of shock (14% vs 29%; P = 0.002), acceleration (5.1 vs 12.3%; P = 0.02), and syncope (4.6 vs 12.3%; P = 0.01) being lower. CONCLUSIONS: Since ATP is less effective in non-QFVTs, they are less well tolerated. Therefore, the substrate of non-QFVTs may need a specific treatment.


Subject(s)
Cardiac Pacing, Artificial/methods , Electrophysiologic Techniques, Cardiac , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/therapy , Equipment Design , Female , Humans , Male , Pacemaker, Artificial , Predictive Value of Tests , Spain , Tachycardia, Ventricular/physiopathology , Time Factors , Treatment Outcome
10.
Cardiology ; 113(3): 172-9, 2009.
Article in English | MEDLINE | ID: mdl-19136825

ABSTRACT

OBJECTIVES: To determine, in patients with ST-segment elevation myocardial infarction (STEMI) treated with primary percutaneous coronary intervention (PPCI), the mechanisms and clinical implications of the acute changes in QT dispersion (QTd). METHODS: In this prospective study we included 216 patients admitted with a STEMI of <12 h of evolution. All were treated with PPCI. QTd was measured prior to PPCI and within 1 h after. RESULTS: The ratio of QTd reduction after PPCI (QTd-R) - defined as [(QTd before PPCI - QTd after PPCI)/QTd before PPCI] x100 - was significantly correlated with the percentage of ST-segment elevation resolution (ST-R; p < 0.001). To determine the significance of the different values of QTd-R, we further subdivided our population into 3 groups according to the tertiles of QTd-R (<10, 11-49, > or =50%). Patients with longer QTd-R had higher percentages of ST-R: 32 +/- 43 for QTd-R <10% vs. 60 +/- 21 for 11-49% vs. 71 +/- 12 for > or =50% (p < 0.05). By logistic regression, patients with QTd-R > or =50% had a reduction of 75% in the adjusted frequency of death or severe heart failure during hospitalization (95% CI 13-73%, p = 0.03). CONCLUSION: QTd-R after PPCI occurs early, is closely related to the restoration of reperfusion at the microvascular level and provides additional prognostic information.


Subject(s)
Angioplasty, Balloon, Coronary , Electrocardiography/methods , Electrocardiography/standards , Myocardial Infarction/diagnosis , Myocardial Infarction/therapy , Aged , Female , Heart Failure/mortality , Humans , Logistic Models , Male , Middle Aged , Multivariate Analysis , Myocardial Infarction/mortality , Predictive Value of Tests , Prognosis , Prospective Studies , ROC Curve , Reproducibility of Results , Risk Factors , Sensitivity and Specificity
11.
Indian Pacing Electrophysiol J ; 8(3): 158-71, 2008 Aug 01.
Article in English | MEDLINE | ID: mdl-18679524

ABSTRACT

BACKGROUND: In atrioventricular nodal re-entrant tachycardias (AVNRT), the achievement of Junctional Rhythms (JR) during Radiofrequency Ablation (RF) is a sensitive but non-specific marker of success. Our aim is to analyze prospectively the predictors of non-inducibility of AVNRT, focusing on the characteristics of the JR. METHODS: We included 75 patients with reproducibly inducible AVNRT. Ablation was performed following an electro-anatomical approach. After each application, the induction protocol was repeated. RESULTS: A total of 341 applications were performed. Although the achievement of >/=1 JR was necessary to obtain the non-inducibility, and the cumulative number of junctional beats (CJB) was higher in effective applications, no CJB cut-off was associated with a success rate higher than 75%. After the observation of a significant correlation between the sinus cycle length (CL) pre-RF and the CL of the JR (JR-CL) (c=0.52; p<0.001), the sinus CL pre-RF/JR-CL ratio (CL-ratio) adequately differentiated the successful vs. unsuccessful applications: 1.41+/-0.23 vs. 1.17+/-0.2 (p<0.001). In a multivariate analysis, a CBJ 11 (p<0.001) and a CL-ratio 1.25 (p<0.001) were found to be the only independent predictors of success. The combination of >/= 11 of CJB with a CL ratio >/= 1.25 achieved non-inducibility in 97% of our patients. CONCLUSION: 1) The specificity of the occurrence of JR as a marker of the successful ablation of AVNRT is increased by the CL-ratio. 2) The achievement of >/= 11 of CJB with a CL ratio >/= 1.25 predicts non-inducibility in almost all patients.

12.
J Electrocardiol ; 40(2): 180-7, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17254595

ABSTRACT

BACKGROUND AND PURPOSE: Myocardial ischemia prolongs the QTc interval. Very little data exists about its prognostic implications in the non-ST-elevation acute coronary syndromes (NST-ACS). METHODS: This is and observational and prospective study in which we evaluated the prognostic implications of the QTc obtained at admission (AQTc) in the short- and long-term of the NST-ACS. The median of the follow-up was 17 months. RESULTS: AQTc correlated adequately with the incidence of adverse events in the short- and long-term (P < .001), with the best cut-off point in 450 milliseconds. Patients with AQTc > or =450 presented higher frequency of in-hospital death: 8.8% vs 1.2%; P = .001, and MACE (death, recurrent ischemia, or urgent coronary revascularization): 72% vs 25%; P < .001. In a Cox regression analysis, we found 3 independent predictors of cardiovascular death after discharge: AQTc > or =450 (14.7% vs 2.1%; P < .0001), age >65 years and left ventricular ejection fraction <40%. Coronary revascularization reduced the risk of posthospitalary cardiovascular death in AQTc > or =450 milliseconds (5% vs 24%; P < .0001) but had no significant effect in AQTc<450 milliseconds. CONCLUSION: These findings provide a new evidence supporting the prognostic value of the AQTc in predicting unfavorable events in the short- and long-term of the NST-ACS.


Subject(s)
Coronary Artery Disease/diagnosis , Coronary Artery Disease/epidemiology , Electrocardiography/methods , Long QT Syndrome/diagnosis , Long QT Syndrome/epidemiology , Myocardial Ischemia/diagnosis , Myocardial Ischemia/epidemiology , Aged , Diagnosis, Computer-Assisted/methods , Diagnosis, Computer-Assisted/statistics & numerical data , Electrocardiography/statistics & numerical data , Female , Humans , Male , Prognosis , Reproducibility of Results , Risk Assessment/methods , Risk Factors , Sensitivity and Specificity , Spain/epidemiology
13.
Rev. esp. cardiol. (Ed. impr.) ; 54(11): 1328-1331, nov. 2001.
Article in Es | IBECS | ID: ibc-2316

ABSTRACT

La hemocromatosis está caracterizada por un excesivo depósito de hierro en una variedad de tejidos. La afección cardíaca sucede en un tercio de los pacientes con hemocromatosis y se produce como consecuencia de una acumulación de ferritina en el músculo cardíaco que induce por un lado una alteración en la función ventricular sistólica y diastólica y por otro un sustrato arritmogénico. Las manifestaciones clínicas pueden estar indistintamente relacionadas con taquiarritmias auriculares, ventriculares, bloqueos aurículoventriculares y/o con insuficiencia cardíaca congestiva, siendo más frecuentes las primeras. Presentamos el caso de una paciente con hemocromatosis secundaria a transfusiones repetidas por anemia sideroblástica con afección cardíaca y cuyas primeras manifestaciones cardíacas fueron taquiarritmias auriculares recurrentes y taquicardia ventricular sostenida sincopal, por lo que se implantó un desfibrilador automático (AU)


Subject(s)
Adult , Female , Humans , Tachycardia, Ventricular , Electrocardiography , Hemochromatosis , Hemochromatosis , Cardiomyopathy, Dilated
SELECTION OF CITATIONS
SEARCH DETAIL
...