ABSTRACT
OBJECTIVES: We aimed to translate and linguistically and cross-culturally validate Sheffield Profile for Assessment and Referral for Care (SPARC) in Spanish for Colombia (SPARC-Sp). METHODS: The linguistic validation of SPARC followed a standard methodology. We conducted focus groups to assess the comprehensibility and feasibility. The acceptability was assessed using a survey study with potential users. RESULTS: The comprehensibility assessment showed that additional adjustments to those made during the translation-back-translation process were required to apply SPARC-Sp in rural and low-schooled populations. It also identified the need for alternative administration mechanisms for illiterate people. The acceptability survey showed that potential users found SPARC-Sp as not only acceptable but also highly desirable. However, they desired to expand the number of items in all domains. SIGNIFICANCE OF RESULTS: Beyond the semantic and conceptual validity attained through the back-translation process, actual cultural validity could be acquired thanks to the comprehensibility tests. Although extending the instrument is something potential users would like to do, it would make it less feasible to utilize the SPARC-Sp in clinical settings. Nonetheless, the instrument might benefit from the inclusion of a domain that evaluates challenges encountered when accessing the health-care system. For communities lacking literacy, alternate administration methods must also be considered.
ABSTRACT
The complexity of aerodynamic particulate matter's (PM) matrices poses a challenge for the extraction and quantification of metals, especially for analytes with low concentration. Aiming to solve this issue, a precise and accurate protocol with the ultrasound extraction combined with microwave radiation digestion (USMW), was applied to PM samples with excellent compensations in sample throughput, digestion efficiency, and energy consumption. After the digestion and extraction procedures, the inorganic analytes, including rare earth elements, were determined by ICP OES. Two types of particulate matter sampled from two stations, Gobernacion (GOB10 and GOB2.5) and Milan (MIL10), corresponding to PM2.5 and PM10, were digested with a combination between HF, HNO3, and H3BO3. The absolute limits of detection ranged from 0.42 pg m-³ for V, to 3459 pg m-³ for As. The accuracy of the experimental study was assessed using two certified reference materials (CRMs), Coal Fly Ash (NIST1633b) and Fly Ash (BCR176). The method presented good accuracy, with recoveries ranging from 90 to 115%, except for Al (120%) and Fe (123%). Considering the replicates for the determination of analyte elements, the repeatability was below 10% for the relative standard deviation (RSD). A cloud point extraction (CPE) procedure, with parameters optimized for the determination of Pd and Pt, was successfully applied in digested PM samples with detection limits of 1.43 and 2.05 pg m-³ for Pd and Pt in MIL10 sample, respectively, and 76.6 pg m-³ for Pd and 110 pg m-³ for Pt, in samples GOB10 and GOB2.5, respectively.
ABSTRACT
The aim of this study was to evaluate different conditioning protocols and sonic/ultrasonic application of an infiltrant resin (IR) in artificial white spot lesions (AWSL). the V/L surfaces of 48 molars were induced to an AWSL and divided in 6 groups, according to the conditioning protocols and application technique: 15% hydrochloric acid (HA) + manual application of the IR; HA + 37% phosphoric acid (PA) + manual application of the IR; HA + ultrasonic application (U) of the IR; HA + sonic application (S) of the IR; PA+HA+S; and PA+HA+U. For the Penetration Depth (PD), the crowns were etched with HA for 120s. The IR Icon® (DMG) was applied according to the manufacturer`s instructions. The crowns were dye penetrated (0.1% red fluorophore rhodamine B isothiocyanate for 12h) and bleached with 30% hydrogen peroxide for 12 h. The discs were immersed in a 50% ethanol solution, containing 100 µM of sodium fluorescein. The PD (in µm) was measured using confocal laser scanning microscopy (20x). The bond strength (BS) was performed by michoshear test (0.5 mm/min). Data were submitted to 2-way ANOVA and Tukey (α=0.05). For BS, the interaction was not significant (p>0.05). For PD, the main factors were significant (application - p<0.001; conditioning technique - p=0.003). The ultrasonic application showed the highest PD values. PA+HA presented higher results than HA. The sonic/ultrasonic applications and the use of phosphoric acid prior to hydrochloric acid improved PD of the infiltrant resin. Conditioning protocols or application techniques did not influence BS values.
Subject(s)
Color , Composite Resins/chemistry , Dental Enamel , Esthetics, Dental , Rhodamines/chemistry , Ultrasonic Waves , Humans , Microscopy, ConfocalABSTRACT
Abstract The aim of this study was to evaluate different conditioning protocols and sonic/ultrasonic application of an infiltrant resin (IR) in artificial white spot lesions (AWSL). the V/L surfaces of 48 molars were induced to an AWSL and divided in 6 groups, according to the conditioning protocols and application technique: 15% hydrochloric acid (HA) + manual application of the IR; HA + 37% phosphoric acid (PA) + manual application of the IR; HA + ultrasonic application (U) of the IR; HA + sonic application (S) of the IR; PA+HA+S; and PA+HA+U. For the Penetration Depth (PD), the crowns were etched with HA for 120s. The IR Icon® (DMG) was applied according to the manufacturer`s instructions. The crowns were dye penetrated (0.1% red fluorophore rhodamine B isothiocyanate for 12h) and bleached with 30% hydrogen peroxide for 12 h. The discs were immersed in a 50% ethanol solution, containing 100 µM of sodium fluorescein. The PD (in µm) was measured using confocal laser scanning microscopy (20x). The bond strength (BS) was performed by michoshear test (0.5 mm/min). Data were submitted to 2-way ANOVA and Tukey (α=0.05). For BS, the interaction was not significant (p>0.05). For PD, the main factors were significant (application - p<0.001; conditioning technique - p=0.003). The ultrasonic application showed the highest PD values. PA+HA presented higher results than HA. The sonic/ultrasonic applications and the use of phosphoric acid prior to hydrochloric acid improved PD of the infiltrant resin. Conditioning protocols or application techniques did not influence BS values.
Resumo: O objetivo deste estudo foi avaliar diferentes protocolos de condicionamento e a aplicação sônica/ultrassônica de uma resina infiltrante (RI) em lesões de mancha branca produzidas artificialmente (LMBA). As superfícies vestibulares/linguais de 48 molares foram induzidas à formação de LMBA e divididas em 6 grupos, de acordo com os protocolos de condicionamento e técnica de aplicação da resina infiltrante: ácido hidroclorídrico 15% (AH) + aplicação manual da RI; AH + ácido fosfórico 37% (AF) + aplicação manual da RI; AH + aplicação ultrassônica da RI (U); AH + aplicação sônica da RI (S); AF + AH + S; e AF + AH + U. para o grau de penetração (GP), condicionou-se as coroas com AH por 120 s. A RI Icon® (DMG) foi aplicada de acordo com as instruções do fabricante. As coroas foram coradas (rodamina B 0,1% por 12 h) e clareadas com peróxido de hidrogênio 30% por 12 h. os discos foram imersos em solução de etanol 50%, contendo 100 µM de fluoresceína sódica. O GP (em µm) foi mensurado por meio de microscopia confocal a laser (20´). A resistência de união (RU) foi calculada pelo teste de microcisalhamento (0,5 mm/min). Os dados foram submetidos ao teste ANOVA 2 fatores e Tukey (α=0,05). Para RU, a interação não foi significante (p>0,05). Para GP, os fatores principais foram significantes (técnica de aplicação - p<0,001; protocolos de condicionamento - p=0,003). A aplicação U mostrou os maiores valores de GP. AF+AH demonstrou resultados superiores ao grupo AH. As aplicações sônica/ultrassônica e o uso do ácido fosfórico antes do ácido hidroclorídrico aumentaram o GP da resina infiltrante. Os protocolos de condicionamento ou as técnicas de aplicação não influenciaram os valores de RU.